Pract Lab Med ; 18: e00141, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31720353

RESUMEN

BACKGROUND: Decreased galactocerebrosidase (GALC) enzyme activity is causative for Krabbe disease, a lysosomal storage disorder with devastating neurodegenerative consequences. Quantitative fluorimetric assays for GALC activity in isolated blood and skin cells have been described; however, no such assay has been described using dried blood spot (DBS) specimens. METHODS: GALC enzyme activity was measured quantitatively using fluorescence from a novel glycosidic substrate: carboxy derived from 6-hexadecanoylamino-4-methylumbelliferone. GALC activity was demonstrated on newborn DBS specimens, known Krabbe disease patient specimens, proficiency testing and quality control samples. RESULTS: We present data on characterization of the novel substrate and assay, including pH optimization and enzyme kinetics using a fluorimetric profile. Single and multi-day precision analyses revealed tight analytical measurements with %CV ranging from 5.2% to 14.1%. GALC enzyme activity was linear over the range of 0.31 - 12.04 µmol/l/h with a limit of detection of 0.066 µmol/l/h. Our results with this assay show a clear discrimination between GALC activities in samples from Krabbe disease patients versus presumed normal newborn samples. CONCLUSIONS: A fluorimetric assay for GALC enzyme activity measurement on dried blood spot specimens is feasible. Improvements to the assay including novel substrate design, increased substrate concentration and removal of sodium chloride maximize the specificity of the assay and minimize interference from ß-galactosidase.

2.
Clin Biochem ; 46(18): 1889-91, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24036022

RESUMEN

OBJECTIVE: Newborn screening for biotinidase deficiency can be performed using a fluorometric enzyme assay on dried blood spot specimens. As a pre-requisite to the consolidation of different enzymatic assays onto a single platform, we describe here a novel analytical method for detecting biotinidase deficiency using the same digital microfluidic cartridge that has already been demonstrated to screen for five lysosomal storage diseases (Pompe, Fabry, Gaucher, Hurler and Hunter) in a multiplex format. METHODS: A novel assay to quantify biotinidase concentration in dried blood spots (DBS) was developed and optimized on the digital microfluidic platform using proficiency testing samples from the Centers for Disease Control and Prevention. The enzymatic assay uses 4-methylumbelliferyl biotin as the fluorogenic substrate. Biotinidase deficiency assays were performed on normal (n=200) and deficient (n=7) newborn DBS specimens. RESULTS: Enzymatic activity analysis of biotinidase deficiency revealed distinct separation between normal and affected DBS specimens using digital microfluidics and these results matched the expected activity. CONCLUSIONS: This study has demonstrated performance of biotinidase deficiency assays by measurement of 4-methylumbelliferyl product on a digital microfluidic platform. Due to the inherent ease in multiplexing on such a platform, consolidation of other fluorometric assays onto a single cartridge may be realized.


Asunto(s)
Deficiencia de Biotinidasa/sangre , Pruebas de Enzimas/métodos , Microfluídica/métodos , Tamizaje Neonatal/métodos , Biotina/análogos & derivados , Biotina/metabolismo , Deficiencia de Biotinidasa/diagnóstico , Pruebas con Sangre Seca , Pruebas de Enzimas/instrumentación , Fluorometría , Humanos , Recién Nacido , Umbeliferonas/metabolismo
3.
Clin Chim Acta ; 424: 12-8, 2013 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-23660237

RESUMEN

PURPOSE: New therapies for lysosomal storage diseases (LSDs) have generated interest in screening newborns for these conditions. We present performance validation data on a digital microfluidic platform that performs multiplex enzymatic assays for Pompe, Fabry, Hunter, Gaucher, and Hurler diseases. METHODS: We developed an investigational disposable digital microfluidic cartridge that uses a single dried blood spot (DBS) punch for performing a 5-plex fluorometric enzymatic assay on up to 44 DBS samples. Precision and linearity of the assays were determined by analyzing quality control DBS samples; clinical performance was determined by analyzing 600 presumed normal and known affected samples (12 for Pompe, 7 for Fabry and 10 each for Hunter, Gaucher and Hurler). RESULTS: Overall coefficient of variation (CV) values between cartridges, days, instruments, and operators ranged from 2 to 21%; linearity correlation coefficients were ≥0.98 for all assays. The multiplex enzymatic assay performed from a single DBS punch was able to discriminate presumed normal from known affected samples for 5 LSDs. CONCLUSIONS: Digital microfluidic technology shows potential for rapid, high-throughput screening for 5 LSDs in a newborn screening laboratory environment. Sample preparation to enzymatic activity on each cartridge is less than 3h.


Asunto(s)
Ensayos Analíticos de Alto Rendimiento/métodos , Enfermedades por Almacenamiento Lisosomal/diagnóstico , Microfluídica/métodos , Tamizaje Neonatal , alfa-Glucosidasas/sangre , Pruebas con Sangre Seca , Pruebas de Enzimas , Ensayos Analíticos de Alto Rendimiento/instrumentación , Ensayos Analíticos de Alto Rendimiento/normas , Humanos , Recién Nacido , Enfermedades por Almacenamiento Lisosomal/sangre , Enfermedades por Almacenamiento Lisosomal/clasificación , Microfluídica/instrumentación , Microfluídica/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , alfa-Glucosidasas/deficiencia
4.
Mol Genet Metab ; 109(2): 218-20, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23578771

RESUMEN

OBJECTIVE: Easy tool for newborn screening of Gaucher and Hurler diseases. METHODS: Method comparison between fluorometric enzymatic activity assay on a digital microfluidic platform and micro-titer plate bench assay was performed on normal (n = 100), Gaucher (n = 10) and Hurler (n = 7) dried blood spot samples. RESULTS: Enzymatic activity analysis of glucocerebrosidase (Gaucher) and α-l-iduronidase (Hurler) revealed similar discrimination between normal and affected samples on both platforms. CONCLUSIONS: Digital microfluidics is suitable for Gaucher and Hurler newborn screening.


Asunto(s)
Pruebas con Sangre Seca/métodos , Enfermedad de Gaucher/diagnóstico , Mucopolisacaridosis I/diagnóstico , Pruebas de Enzimas , Enfermedad de Gaucher/sangre , Glucosilceramidasa/sangre , Humanos , Iduronidasa/sangre , Recién Nacido , Microfluídica , Mucopolisacaridosis I/sangre , Tamizaje Neonatal
5.
Mol Genet Metab ; 105(3): 519-21, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22227323

RESUMEN

Mucopolysaccharidosis type II (MPS II) or Hunter syndrome is a lysosomal storage disease caused by deficiency of iduronate-2-sulfatase (IDS). A convenient single-step fluorometric microplate enzyme assay has been developed and validated for clinical diagnosis of MPS II using dried blood spots (DBS). The assay compared well with a recently reported digital microfluidic method, from which it was adapted. Results show that this DBS assay is robust and reproducible using both technologies.


Asunto(s)
Pruebas con Sangre Seca , Pruebas de Enzimas/métodos , Iduronato Sulfatasa/sangre , Mucopolisacaridosis II/diagnóstico , Fluorometría/métodos , Humanos , Iduronato Sulfatasa/genética , Técnicas Analíticas Microfluídicas , Mucopolisacaridosis II/sangre , Mucopolisacaridosis II/enzimología
6.
Anal Chem ; 83(22): 8439-47, 2011 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-21932784

RESUMEN

The feasibility of implementing pyrosequencing chemistry within droplets using electrowetting-based digital microfluidics is reported. An array of electrodes patterned on a printed-circuit board was used to control the formation, transportation, merging, mixing, and splitting of submicroliter-sized droplets contained within an oil-filled chamber. A three-enzyme pyrosequencing protocol was implemented in which individual droplets contained enzymes, deoxyribonucleotide triphosphates (dNTPs), and DNA templates. The DNA templates were anchored to magnetic beads which enabled them to be thoroughly washed between nucleotide additions. Reagents and protocols were optimized to maximize signal over background, linearity of response, cycle efficiency, and wash efficiency. As an initial demonstration of feasibility, a portion of a 229 bp Candida parapsilosis template was sequenced using both a de novo protocol and a resequencing protocol. The resequencing protocol generated over 60 bp of sequence with 100% sequence accuracy based on raw pyrogram levels. Excellent linearity was observed for all of the homopolymers (two, three, or four nucleotides) contained in the C. parapsilosis sequence. With improvements in microfluidic design it is expected that longer reads, higher throughput, and improved process integration (i.e., "sample-to-sequence" capability) could eventually be achieved using this low-cost platform.


Asunto(s)
ADN de Hongos/análisis , ADN de Hongos/genética , Técnicas Analíticas Microfluídicas/métodos , Análisis de Secuencia de ADN/métodos , Secuencia de Bases , Candida/genética , Desoxirribonucleótidos/análisis , Desoxirribonucleótidos/genética , Desoxirribonucleótidos/metabolismo , Electrodos , Enzimas/química , Enzimas/metabolismo , Técnicas Analíticas Microfluídicas/instrumentación , Análisis de Secuencia de ADN/instrumentación , Moldes Genéticos
7.
Clin Chem ; 57(10): 1444-51, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21859904

RESUMEN

BACKGROUND: Newborn screening for lysosomal storage diseases (LSDs) has been gaining considerable interest owing to the availability of enzyme replacement therapies. We present a digital microfluidic platform to perform rapid, multiplexed enzymatic analysis of acid α-glucosidase (GAA) and acid α-galactosidase to screen for Pompe and Fabry disorders. The results were compared with those obtained using standard fluorometric methods. METHODS: We performed bench-based, fluorometric enzymatic analysis on 60 deidentified newborn dried blood spots (DBSs), plus 10 Pompe-affected and 11 Fabry-affected samples, at Duke Biochemical Genetics Laboratory using a 3-mm punch for each assay and an incubation time of 20 h. We used a digital microfluidic platform to automate fluorometric enzymatic assays at Advanced Liquid Logic Inc. using extract from a single punch for both assays, with an incubation time of 6 h. Assays were also performed with an incubation time of 1 h. RESULTS: Assay results were generally comparable, although mean enzymatic activity for GAA using microfluidics was approximately 3 times higher than that obtained using bench-based methods, which could be attributed to higher substrate concentration. Clear separation was observed between the normal and affected samples at both 6- and 1-h incubation times using digital microfluidics. CONCLUSIONS: A digital microfluidic platform compared favorably with a clinical reference laboratory to perform enzymatic analysis in DBSs for Pompe and Fabry disorders. This platform presents a new technology for a newborn screening laboratory to screen LSDs by fully automating all the liquid-handling operations in an inexpensive system, providing rapid results.


Asunto(s)
Pruebas Enzimáticas Clínicas/instrumentación , Enfermedad de Fabry/diagnóstico , Enfermedad del Almacenamiento de Glucógeno Tipo II/diagnóstico , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , alfa-Galactosidasa/sangre , alfa-Glucosidasas/sangre , Fluorometría , Humanos , Recién Nacido , Tamizaje Neonatal
9.
Expert Rev Mol Diagn ; 11(4): 393-407, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21545257

RESUMEN

Digital microfluidics based on electrowetting is a type of microfluidic platform in which liquids are processed as individual unit-sized droplets that are dispensed from a source, merged together, split apart or transported between locations on demand. These devices are implemented using arrays of surface electrodes to control the shape and position of droplets through the electrowetting effect. A major thrust of digital microfluidics research has been the development of integrated lab-on-a-chip devices to perform clinical in vitro diagnostic assays. A variety of preparatory and analytical processes have been implemented and feasibility has been demonstrated for test types ranging from clinical chemistries to immunoassays, nucleic acid tests and cell-based assays. In this article, the current state and future potential of digital microfluidics for clinical diagnostic testing is reviewed and evaluated.


Asunto(s)
Técnicas de Laboratorio Clínico , Electrohumectación , Técnicas Analíticas Microfluídicas , Humanos , Manejo de Especímenes/métodos
10.
Semin Perinatol ; 34(2): 163-9, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20207266

RESUMEN

Expansion of newborn screening for inherited metabolic disorders using tandem mass spectrometry has generated interest in screening for other treatable conditions, including lysosomal storage diseases. Limitations to expansion include labor and equipment costs. We describe a cost-effective new platform that reduces the time to result reporting and can perform multiplexing assays requiring different platforms. Immunoassays and enzyme activity assays currently used in newborn screening have been translated to a disposable microchip programmed to dispense, transport, mix, wash, and incubate individual microdroplets from specimens, including dried blood spot extracts, and reagents all under software control. The specimen and reagents consumed are approximately 1% of those required by equivalent bench assays. In addition to immunologic and enzymatic assays, DNA amplification, amplicon detection, and sequencing have been demonstrated using the same microchips and control equipment. Recently, the multiplexing of 4 different enzyme activities has also been demonstrated with negligible cross-contamination. We review assays relevant to newborn screening.


Asunto(s)
Técnicas Analíticas Microfluídicas , Tamizaje Neonatal/métodos , Pruebas de Enzimas/métodos , Humanos , Inmunoensayo/métodos , Recién Nacido , Técnicas de Amplificación de Ácido Nucleico/métodos
11.
Diagn Microbiol Infect Dis ; 67(1): 22-9, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20227222

RESUMEN

Rapid, accurate diagnosis of community-acquired pneumonia (CAP) due to Mycoplasma pneumoniae is compromised by low sensitivity of culture and serology. Polymerase chain reaction (PCR) has emerged as a sensitive method to detect M. pneumoniae DNA in clinical specimens. However, conventional real-time PCR is not cost-effective for routine or outpatient implementation. Here, we evaluate a novel microfluidic real-time PCR platform (Advanced Liquid Logic, Research Triangle Park, NC) that is rapid, portable, and fully automated. We enrolled patients with CAP and extracted DNA from nasopharyngeal wash (NPW) specimens using a biotinylated capture probe and streptavidin-coupled magnetic beads. Each extract was tested for M. pneumoniae-specific DNA by real-time PCR on both conventional and microfluidic platforms using Taqman probe and primers. Three of 59 (5.0%) NPWs were positive, and agreement between the methods was 98%. The microfluidic platform was equally sensitive but 3 times faster and offers an inexpensive and convenient diagnostic test for microbial DNA.


Asunto(s)
Técnicas Bacteriológicas/métodos , Microfluídica/métodos , Técnicas de Diagnóstico Molecular/métodos , Mycoplasma pneumoniae/aislamiento & purificación , Neumonía por Mycoplasma/diagnóstico , Reacción en Cadena de la Polimerasa/métodos , Automatización , Infecciones Comunitarias Adquiridas/microbiología , Humanos , Mycoplasma pneumoniae/genética , Nasofaringe/microbiología , Neumonía por Mycoplasma/microbiología , Sistemas de Atención de Punto , Sensibilidad y Especificidad , Factores de Tiempo
12.
Anal Chem ; 82(6): 2310-6, 2010 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-20151681

RESUMEN

This paper details the development of a digital microfluidic platform for multiplexed real-time polymerase chain reactions (PCR). Liquid samples in discrete droplet format are programmably manipulated upon an electrode array by the use of electrowetting. Rapid PCR thermocycling is performed in a closed-loop flow-through format where for each cycle the reaction droplets are cyclically transported between different temperature zones within an oil-filled cartridge. The cartridge is fabricated using low-cost printed-circuit-board technology and is intended to be a single-use disposable device. The PCR system exhibited remarkable amplification efficiency of 94.7%. To test its potential application in infectious diseases, this novel PCR system reliably detected diagnostic DNA levels of methicillin-resistant Staphylococcus aureus (MRSA), Mycoplasma pneumoniae , and Candida albicans . Amplification of genomic DNA samples was consistently repeatable across multiple PCR loops both within and between cartridges. In addition, simultaneous real-time PCR amplification of both multiple different samples and multiple different targets on a single cartridge was demonstrated. A novel method of PCR speed optimization using variable cycle times has also been proposed and proven feasible. The versatile system includes magnetic bead handling capability, which was applied to the analysis of simulated clinical samples that were prepared from whole blood using a magnetic bead capture protocol. Other salient features of this versatile digital microfluidic PCR system are also discussed, including the configurability and scalability of microfluidic operations, instrument portability, and substrate-level integration with other pre- and post-PCR processes.


Asunto(s)
ADN Bacteriano/análisis , ADN de Hongos/análisis , Staphylococcus aureus Resistente a Meticilina/genética , Microfluídica/instrumentación , Reacción en Cadena de la Polimerasa/instrumentación , Candida albicans/genética , ADN Bacteriano/genética , ADN de Hongos/genética , Diseño de Equipo , Mycoplasma pneumoniae/genética
13.
Lab Chip ; 8(12): 2091-104, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19023472

RESUMEN

Point of care testing is playing an increasingly important role in improving the clinical outcome in health care management. The salient features of a point of care device are rapid results, integrated sample preparation and processing, small sample volumes, portability, multifunctionality and low cost. In this paper, we demonstrate some of these salient features utilizing an electrowetting-based Digital Microfluidic platform. We demonstrate the performance of magnetic bead-based immunoassays (cardiac troponin I) on a digital microfluidic cartridge in less than 8 minutes using whole blood samples. Using the same microfluidic cartridge, a 40-cycle real-time polymerase chain reaction was performed within 12 minutes by shuttling a droplet between two thermal zones. We further demonstrate, on the same cartridge, the capability to perform sample preparation for bacterial infectious disease pathogen, methicillin-resistant Staphylococcus aureus and for human genomic DNA using magnetic beads. In addition to rapid results and integrated sample preparation, electrowetting-based digital microfluidic instruments are highly portable because fluid pumping is performed electronically. All the digital microfluidic chips presented here were fabricated on printed circuit boards utilizing mass production techniques that keep the cost of the chip low. Due to the modularity and scalability afforded by digital microfluidics, multifunctional testing capability, such as combinations within and between immunoassays, DNA amplification, and enzymatic assays, can be brought to the point of care at a relatively low cost because a single chip can be configured in software for different assays required along the path of care.


Asunto(s)
Microfluídica/métodos , Sistemas de Atención de Punto , Análisis Químico de la Sangre , ADN/química , Humanos , Inmunoensayo , Luminiscencia , Microfluídica/instrumentación , Factores de Tiempo
14.
Lab Chip ; 8(12): 2188-96, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19023486

RESUMEN

A digital microfluidic platform for performing heterogeneous sandwich immunoassays based on efficient handling of magnetic beads is presented in this paper. This approach is based on manipulation of discrete droplets of samples and reagents using electrowetting without the need for channels where the droplets are free to move laterally. Droplet-based manipulation of magnetic beads therefore does not suffer from clogging of channels. Immunoassays on a digital microfluidic platform require the following basic operations: bead attraction, bead washing, bead retention, and bead resuspension. Several parameters such as magnetic field strength, pull force, position, and buffer composition were studied for effective bead operations. Dilution-based washing of magnetic beads was demonstrated by immobilizing the magnetic beads using a permanent magnet and splitting the excess supernatant using electrowetting. Almost 100% bead retention was achieved after 7776-fold dilution-based washing of the supernatant. Efficient resuspension of magnetic beads was achieved by transporting a droplet with magnetic beads across five electrodes on the platform and exploiting the flow patterns within the droplet to resuspend the beads. All the magnetic-bead droplet operations were integrated together to generate standard curves for sandwich heterogeneous immunoassays on human insulin and interleukin-6 (IL-6) with a total time to result of 7 min for each assay.


Asunto(s)
Inmunoensayo , Magnetismo , Microfluídica/instrumentación , Microfluídica/métodos , Humanos , Inmunoensayo/métodos , Insulina/química , Interleucina-6/química , Magnetismo/instrumentación
15.
J Biol Chem ; 281(16): 10856-64, 2006 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-16492667

RESUMEN

Parathyroid hormone (PTH) regulates calcium homeostasis via the type I PTH/PTH-related peptide (PTH/PTHrP) receptor (PTH1R). The purpose of the present study was to identify the contributions of distinct signaling mechanisms to PTH-stimulated activation of the mitogen-activated protein kinases (MAPK) ERK1/2. In Human embryonic kidney 293 (HEK293) cells transiently transfected with hPTH1R, PTH stimulated a robust increase in ERK activity. The time course of ERK1/2 activation was biphasic with an early peak at 10 min and a later sustained ERK1/2 activation persisting for greater than 60 min. Pretreatment of HEK293 cells with the PKA inhibitor H89 or the PKC inhibitor GF109203X, individually or in combination reduced the early component of PTH-stimulated ERK activity. However, these inhibitors of second messenger dependent kinases had little effect on the later phase of PTH-stimulated ERK1/2 phosphorylation. This later phase of ERK1/2 activation at 30-60 min was blocked by depletion of cellular beta-arrestin 2 and beta-arrestin 1 by small interfering RNA. Furthermore, stimulation of hPTH1R with PTH analogues, [Trp1]PTHrp-(1-36) and [d-Trp12,Tyr34]PTH-(7-34), selectively activated G(s)/PKA-mediated ERK1/2 activation or G protein-independent/beta-arrestin-dependent ERK1/2 activation, respectively. It is concluded that PTH stimulates ERK1/2 through several distinct signal transduction pathways: an early G protein-dependent pathway meditated by PKA and PKC and a late pathway independent of G proteins mediated through beta-arrestins. These findings imply the existence of distinct active conformations of the hPTH1R responsible for the two pathways, which can be stimulated by unique ligands. Such ligands may have distinct and valuable therapeutic properties.


Asunto(s)
Arrestinas/fisiología , Proteínas de Unión al GTP/fisiología , Proteína Quinasa 1 Activada por Mitógenos/metabolismo , Proteína Quinasa 3 Activada por Mitógenos/metabolismo , Receptor de Hormona Paratiroídea Tipo 1/metabolismo , Arrestinas/metabolismo , Línea Celular , Células Cultivadas , Medio de Cultivo Libre de Suero/farmacología , AMP Cíclico/metabolismo , Proteínas Quinasas Dependientes de AMP Cíclico/metabolismo , ADN/metabolismo , ADN Complementario/metabolismo , Proteínas de Unión al GTP/metabolismo , Humanos , Immunoblotting , Inmunoprecipitación , Indoles/farmacología , Isoquinolinas/farmacología , Ligandos , Sistema de Señalización de MAP Quinasas , Maleimidas/farmacología , Mutación , Fosforilación , Proteínas Quinasas/metabolismo , ARN Interferente Pequeño/metabolismo , Receptor de Hormona Paratiroídea Tipo 1/genética , Transducción de Señal , Sulfonamidas/farmacología , Factores de Tiempo , Transfección , beta-Arrestina 1 , Arrestina beta 2 , beta-Arrestinas