Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Circ Cardiovasc Imaging ; 17(6): e016635, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38889213

RESUMEN

BACKGROUND: Despite recent guideline recommendations, quantitative perfusion (QP) estimates of myocardial blood flow from cardiac magnetic resonance (CMR) have only been sparsely validated. Furthermore, the additional diagnostic value of utilizing QP in addition to the traditional visual expert interpretation of stress-perfusion CMR remains unknown. The aim was to investigate the correlation between myocardial blood flow measurements estimated by CMR, positron emission tomography, and invasive coronary thermodilution. The second aim is to investigate the diagnostic performance of CMR-QP to identify obstructive coronary artery disease (CAD). METHODS: Prospectively enrolled symptomatic patients with >50% diameter stenosis on computed tomography angiography underwent dual-bolus CMR and positron emission tomography with rest and adenosine-stress myocardial blood flow measurements. Subsequently, an invasive coronary angiography (ICA) with fractional flow reserve and thermodilution-based coronary flow reserve was performed. Obstructive CAD was defined as both anatomically severe (>70% diameter stenosis on quantitative coronary angiography) or hemodynamically obstructive (ICA with fractional flow reserve ≤0.80). RESULTS: About 359 patients completed all investigations. Myocardial blood flow and reserve measurements correlated weakly between estimates from CMR-QP, positron emission tomography, and ICA-coronary flow reserve (r<0.40 for all comparisons). In the diagnosis of anatomically severe CAD, the interpretation of CMR-QP by an expert reader improved the sensitivity in comparison to visual analysis alone (82% versus 88% [P=0.03]) without compromising specificity (77% versus 74% [P=0.28]). In the diagnosis of hemodynamically obstructive CAD, the accuracy was only moderate for a visual expert read and remained unchanged when additional CMR-QP measurements were interpreted. CONCLUSIONS: CMR-QP correlates weakly to myocardial blood flow measurements by other modalities but improves diagnosis of anatomically severe CAD. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03481712.


Asunto(s)
Angiografía Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Tomografía de Emisión de Positrones , Termodilución , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Velocidad del Flujo Sanguíneo , Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Circulación Coronaria/fisiología , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico/fisiología , Imagen de Perfusión Miocárdica/métodos , Tomografía de Emisión de Positrones/métodos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
2.
Eur Heart J Cardiovasc Imaging ; 25(7): 958-967, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38376457

RESUMEN

AIMS: Myocardial perfusion imaging (MPI) using [15O]H2O positron emission tomography (PET) is used to guide the selection of patients with angina for invasive angiography and possible revascularization. Our study evaluated (i) whether atrial fibrillation (AF) reduces global hyperaemic myocardial blood flow (MBF) and (ii) whether [15O]H2O PET MPI effectively guides revascularization procedures for patients with ongoing AF. METHODS AND RESULTS: We prospectively recruited 346 patients with angina and persistent or paroxysmal AF referred for baseline/hyperaemic [15O]H2O PET MPI. The primary outcome was revascularization within 3 months of MPI. In the analyses, patients were divided into four groups based on whether they had ongoing AF or sinus rhythm (SR) and whether they had previously documented coronary artery disease (CAD) or not. Thus, four groups were compared: SR-noCAD, AF-noCAD, SR-CAD, and AF-CAD. Hyperaemic MBF was affected by both ongoing AF and prior CAD [MBF (mL/min/g): 2.82 (SR-noCAD) vs. 2.12 (AF-noCAD) vs. 2.22 (SR-CAD) vs. 1.80 (AF-CAD), two-way analysis of variance P < 0.0001]. In multiple linear regression, ongoing AF was independently associated with reduced hyperaemic MBF. Every 0.1 mL/min/g decrease in hyperaemic MBF was associated with a 23% increase in odds of early revascularization. Receiver operating characteristic (ROC) analysis of vessel-specific hyperaemic MBF to predict early revascularization yielded the following areas under the ROC curve: SR-noCAD: 0.95 (P < 0.0001); AF-noCAD: 0.79 (P < 0.0001); SR-CAD: 0.78 (P < 0.0001); and AF-CAD: 0.88 (P < 0.0001). CONCLUSION: Ongoing AF is associated with 19-25% reduced global hyperaemic MBF as measured by [15O]H2O MPI PET. Regardless, vessel-specific hyperaemic MBF still predicts early revascularization in patients with AF.


Asunto(s)
Fibrilación Atrial , Imagen de Perfusión Miocárdica , Revascularización Miocárdica , Radioisótopos de Oxígeno , Tomografía de Emisión de Positrones , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Femenino , Masculino , Imagen de Perfusión Miocárdica/métodos , Estudios Prospectivos , Tomografía de Emisión de Positrones/métodos , Persona de Mediana Edad , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Angina de Pecho/diagnóstico por imagen , Estudios de Cohortes , Angiografía Coronaria/métodos , Curva ROC , Índice de Severidad de la Enfermedad , Medición de Riesgo
3.
Circ Cardiovasc Imaging ; 17(1): e016138, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38227687

RESUMEN

BACKGROUND: Guidelines propose the inclusion of quantitative measurements from 82Rubidium positron emission tomography (RbPET) to discriminate obstructive coronary artery disease (CAD). However, the effect on diagnostic accuracy is unknown. The aim was to investigate the optimal RbPET reading algorithm for improved identification of obstructive CAD. METHODS: Prospectively enrolled patients (N=400) underwent RbPET and invasive coronary angiography with fractional flow reserve and quantitative coronary angiography. Quantitative measurements (myocardial blood flow (MBF), MBF reserve, transient ischemic dilatation) by RbPET were step-wisely added to a qualitative assessment by the summed stress score based on their diagnostic accuracy of obstructive CAD by invasive coronary angiography-fractional flow reserve. Prespecified cutoffs were summed stress score ≥4, hyperemic MBF 2.00 mL/g per min, and MBF reserve 1.80, respectively. Hemodynamically obstructive CAD was defined as >90% diameter stenosis or invasive coronary angiography-fractional flow reserve ≤0.80, and sensitivity analyses included a clinically relevant reference of anatomically severe CAD (>70% diameter stenosis by invasive coronary angiography-quantitative coronary angiography). RESULTS: Hemodynamically obstructive CAD was present in 170/400 (42.5%) patients. Stand-alone summed stress score showed a sensitivity and specificity of 57% and 93%, respectively, while hyperemic MBF showed similar sensitivity (61%, P=0.57) but lower specificity (85%, P=0.008). With increased discrimination by receiver-operating characteristic curves (0.78 versus 0.85; P<0.001), combining summed stress score, MBF and MBF reserve showed the highest sensitivity of 77% but lower specificity of 74% (P<0.001 for both comparisons). Against anatomically severe CAD, all measures independently yielded high discrimination ≥0.90 with increased sensitivity and lower specificity by additional quantification. CONCLUSIONS: The inclusion of quantitative measurements to a RbPET read increases in the identification of obstructive CAD. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03481712.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Humanos , Rubidio , Constricción Patológica , Enfermedad de la Arteria Coronaria/diagnóstico , Angiografía Coronaria/métodos , Tomografía de Emisión de Positrones/métodos , Circulación Coronaria , Perfusión , Imagen de Perfusión Miocárdica/métodos , Valor Predictivo de las Pruebas
4.
Open Heart ; 10(2)2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37487656

RESUMEN

INTRODUCTION: Current guideline recommend functional imaging for myocardial ischaemia if coronary CT angiography (CTA) has shown coronary artery disease (CAD) of uncertain functional significance. However, diagnostic accuracy of selective myocardial perfusion imaging after coronary CTA is currently unclear. The Danish study of Non-Invasive testing in Coronary Artery Disease 3 trial is designed to evaluate head to head the diagnostic accuracy of myocardial perfusion imaging with positron emission tomography (PET) using the tracers 82Rubidium (82Rb-PET) compared with oxygen-15 labelled water PET (15O-water-PET) in patients with symptoms of obstructive CAD and a coronary CT scan with suspected obstructive CAD. METHODS AND ANALYSIS: This prospective, multicentre, cross-sectional study will include approximately 1000 symptomatic patients without previous CAD. Patients are included after referral to coronary CTA. All patients undergo a structured interview and blood is sampled for genetic and proteomic analysis and a coronary CTA. Patients with possible obstructive CAD at coronary CTA are examined with both 82Rb-PET, 15O-water-PET and invasive coronary angiography with three-vessel fractional flow reserve and thermodilution measurements of coronary flow reserve. After enrolment, patients are followed with Seattle Angina Questionnaires and follow-up PET scans in patients with an initially abnormal PET scan and for cardiovascular events in 10 years. ETHICS AND DISSEMINATION: Ethical approval was obtained from Danish regional committee on health research ethics. Written informed consent will be provided by all study participants. Results of this study will be disseminated via articles in international peer-reviewed journal. TRIAL REGISTRATION NUMBER: NCT04707859.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estudios Transversales , Dinamarca , Estudios Prospectivos , Proteómica , Agua , Estudios Multicéntricos como Asunto
5.
Eur Heart J Cardiovasc Imaging ; 25(1): 39-47, 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-37282714

RESUMEN

AIMS: Clinical likelihood (CL) models are designed based on a reference of coronary stenosis in patients with suspected obstructive coronary artery disease. However, a reference standard for myocardial perfusion defects (MPDs) could be more appropriate. We aimed to investigate the ability of the 2019 European Society of Cardiology pre-test probability (ESC-PTP), the risk-factor-weighted (RF-CL) model, and coronary artery calcium score-weighted (CACS-CL) model to diagnose MPDs. METHODS AND RESULTS: Symptomatic stable de novo chest pain patients (n = 3374) underwent coronary computed tomography angiography and subsequent myocardial perfusion imaging by single-photon emission computed tomography, positron emission tomography, or cardiac magnetic resonance. For all modalities, MPD was defined as coronary computed tomography angiography with suspected stenosis and stress-perfusion abnormality in ≥2 segments. The ESC-PTP was calculated based on age, sex, and symptom typicality, and the RF-CL and CACS-CL additionally included a number of risk factors and CACS. In total, 219/3374 (6.5%) patients had an MPD. Both the RF-CL and the CACS-CL classified substantially more patients to low CL (<5%) of obstructive coronary artery disease compared with the ESC-PTP (32.5 and 54.1 vs. 12.0%, P < 0.001) with preserved low prevalences of MPD (<2% for all models). Compared with the ESC-PTP [area under the receiver-operating characteristic curve (AUC) 0.74 (0.71-0.78)], the discrimination of having an MPD was higher for the CACS-CL model [AUC 0.88 (0.86-0.91), P < 0.001], while it was similar for the RF-CL model [AUC 0.73 (0.70-0.76), P = 0.32]. CONCLUSION: Compared with basic CL models, the RF-CL and CACS-CL models improve down classification of patients to a very low-risk group with a low prevalence of MPD.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Imagen de Perfusión Miocárdica , Humanos , Enfermedad de la Arteria Coronaria/epidemiología , Funciones de Verosimilitud , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico , Tomografía Computarizada de Emisión de Fotón Único/métodos , Angiografía por Tomografía Computarizada , Valor Predictivo de las Pruebas , Imagen de Perfusión Miocárdica/métodos
6.
JACC Cardiovasc Imaging ; 16(10): 1321-1331, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37052562

RESUMEN

BACKGROUND: Fractional flow reserve (FFR) derived from invasive coronary angiography (QFR) is promising for evaluation of intermediate coronary artery stenosis. OBJECTIVES: The authors aimed to compare the diagnostic performance of QFR and the guideline-recommended invasive FFR using 82Rubidium positron emission tomography (82Rb-PET) myocardial perfusion imaging as reference standard. METHODS: This is a prospective, observational study of symptomatic patients with suspected obstructive coronary artery disease on coronary computed tomography angiography (≥50% diameter stenosis in ≥1 vessel). All patients were referred to 82Rb-PET and invasive coronary angiography with FFR and QFR assessment of all intermediate (30%-90% diameter stenosis) stenoses. Main analyses included a comparison of the ability of QFR and FFR to identify reduced myocardial blood flow (<2 mL/g/min) during vasodilation and/or relative perfusion abnormalities (summed stress score ≥4 in ≥2 adjacent segments). RESULTS: A total of 250 patients (320 vessels) with indication for invasive physiological assessment were included. The continuous relationship of 82Rb-PET stress myocardial blood flow per 0.10 increase in FFR was +0.14 mL/g/min (95% CI: 0.07-0.21 mL/g/min) and +0.08 mL/g/min (95% CI: 0.02-0.14 mL/g/min) per 0.10 QFR increase. Using 82Rb-PET as reference, QFR and FFR had similar diagnostic performance on both a per-patient level (accuracy: 73%; 95% CI: 67%-79%; vs accuracy: 71%; 95% CI: 64%-78%) and per-vessel level (accuracy: 70%; 95% CI: 64%-75%; vs accuracy: 68%; 95% CI: 62%-73%). The per-vessel feasibility was 84% (95% CI: 80%-88%) for QFR and 88% (95% CI: 85%-92%) for FFR by intention-to-diagnose analysis. CONCLUSIONS: With 82Rb-PET as reference modality, the wire-free QFR solution showed similar diagnostic accuracy as invasive FFR in evaluation of intermediate coronary stenosis. (DAN-NICAD - Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease; NCT02264717).


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Reserva del Flujo Fraccional Miocárdico/fisiología , Constricción Patológica , Termodilución , Vasos Coronarios/diagnóstico por imagen , Valor Predictivo de las Pruebas , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/terapia , Angiografía Coronaria/métodos , Tomografía de Emisión de Positrones , Índice de Severidad de la Enfermedad
7.
Heart ; 109(16): 1223-1230, 2023 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-36878672

RESUMEN

OBJECTIVE: Validation studies of the 2019 European Society of Cardiology pretest probability model (ESC-PTP) for coronary artery disease (CAD) report that 35%-40% of patients have low pretest probability (ESC-PTP 5% to <15%). Acoustic detection of coronary stenoses could potentially improve clinical likelihood stratification. Aims were to (1) investigate the diagnostic performance of an acoustic-based CAD score and (2) study the reclassification potential of a dual likelihood strategy by the ESC-PTP and a CAD score. METHODS: Consecutive patients (n=1683) with stable angina symptoms referred for coronary CT angiography (CTA) underwent heart sound analyses by an acoustic CAD-score device. All patients with ≥50% luminal stenosis in any coronary segment at coronary CTA were referred to investigation with invasive coronary angiography (ICA) with fractional flow reserve (FFR).A predefined CAD-score cut-off ≤20 was used to rule out obstructive CAD. RESULTS: In total, 439 patients (26%) had ≥50% luminal stenosis on coronary CTA. The subsequent ICA with FFR showed obstructive CAD in 199 patients (11.8%). Using the ≤20 CAD-score cut-off for obstructive CAD rule-out, sensitivity was 85.4% (95% CI 79.7 to 90.0), specificity 40.4% (95% CI 37.9 to 42.9), positive predictive value 16.1% (95% CI 13.9 to 18.5) and negative predictive value 95.4% (95% CI 93.4 to 96.9) in all patients. Applying the cut-off in ESC-PTP 5% to <15% patients, 316 patients (48%) were down-classified to very-low likelihood. The obstructive CAD prevalence was 3.5% in this group. CONCLUSION: In a large contemporary cohort of patients with low CAD likelihood, the additional use of an acoustic rule-out device showed a clear potential to downgrade likelihood and could supplement current strategies for likelihood assessment to avoid unnecessary testing. TRIAL REGISTRATION NUMBER: NCT03481712.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Acústica , Angiografía por Tomografía Computarizada , Constricción Patológica , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Valor Predictivo de las Pruebas , Probabilidad
8.
JACC Cardiovasc Imaging ; 16(5): 642-655, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36881421

RESUMEN

BACKGROUND: Guidelines recommend verification of myocardial ischemia by selective second-line myocardial perfusion imaging (MPI) following a coronary computed tomography angiography (CTA) with suspected obstructive coronary artery disease (CAD). Head-to-head data on the diagnostic performance of different MPI modalities in this setting are sparse. OBJECTIVES: The authors sought to compare, head-to-head, the diagnostic performance of selective MPI by 3.0-T cardiac magnetic resonance (CMR) and 82rubidium positron emission tomography (RbPET) in patients with suspected obstructive stenosis at coronary CTA using invasive coronary angiography (ICA) with fractional flow reserve (FFR) as reference. METHODS: Consecutive patients (n = 1,732, mean age: 59.1 ± 9.5 years, 57.2% men) referred for coronary CTA with symptoms suggestive of obstructive CAD were included. Patients with suspected stenosis were referred for both CMR and RbPET and subsequently ICA. Obstructive CAD was defined as FFR ≤0.80 or >90% diameter stenosis by visual assessment. RESULTS: In total, 445 patients had suspected stenosis on coronary CTA. Of these, 372 patients completed both CMR, RbPET and subsequent ICA with FFR. Hemodynamically obstructive CAD was identified in 164 of 372 (44.1%) patients. Sensitivities for CMR and RbPET were 59% (95% CI: 51%-67%) and 64% (95% CI: 56%-71%); P = 0.21, respectively, and specificities 84% (95% CI: 78%-89%) and 89% (95% CI: 84%-93%]); P = 0.08, respectively. Overall accuracy was higher for RbPET compared with CMR (73% vs 78%; P = 0.03). CONCLUSIONS: In patients with suspected obstructive stenosis at coronary CTA, CMR, and RbPET show similar and moderate sensitivities but high specificities compared with ICA with FFR. This patient group represents a diagnostic challenge with frequent mismatch between advanced MPI tests and invasive measurements. (Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease 2 [Dan-NICAD 2]; NCT03481712).


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Angiografía Coronaria/métodos , Constricción Patológica , Valor Predictivo de las Pruebas , Tomografía de Emisión de Positrones/métodos , Angiografía por Tomografía Computarizada/métodos , Espectroscopía de Resonancia Magnética , Estenosis Coronaria/diagnóstico por imagen
9.
EuroIntervention ; 17(7): 576-583, 2021 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-33196446

RESUMEN

BACKGROUND: CT-QFR is a novel coronary computed tomography angiography (CTA)-based method for on-site evaluation of patients with suspected obstructive coronary artery disease (CAD). AIMS: We aimed to compare the diagnostic performance of CT-QFR with myocardial perfusion scintigraphy (MPS) and cardiovascular magnetic resonance (CMR) as second-line tests in patients with suspected obstructive CAD after coronary CTA. METHODS: A paired analysis of CT-QFR and MPS or CMR, with an invasive FFR-based classification as reference standard was carried out. Symptomatic patients with >50% diameter stenosis on coronary CTA were randomised to MPS or CMR and referred for invasive coronary angiography. RESULTS: The rate of coronary CTA not feasible for CT-QFR analysis was 17%. Paired patient-level data were available for 118 patients in the MPS group and 113 in the CMR group. Patient-level diagnostic accuracy was better for CT-QFR than for both MPS (82.2% [95% CI: 75.2-89.2] vs 70.3% [95% CI: 62.0-78.7], p=0.029) and CMR (77.0% [95% CI: 69.1-84.9] vs 65.5% [95% CI: 56.6-74.4], p=0.047). Following a positive coronary CTA and with the intention to diagnose, CT-QFR, CMR and MPS were equally suitable as rule-in and rule-out modalities. CONCLUSIONS: The diagnostic performance of CT-QFR as a second-line test was at least similar to MPS and CMR for the evaluation of obstructive CAD in symptomatic patients presenting with ≥50% diameter stenosis on coronary CTA.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Humanos , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas
10.
Am Heart J ; 215: 114-128, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31323454

RESUMEN

BACKGROUND: Coronary computed tomography angiography (CTA) is the preferred primary diagnostic modality when examining patients with low to intermediate pre-test probability of coronary artery disease (CAD). Only 20-30% of these have potentially obstructive CAD. Because of the relatively poor positive predictive value of coronary CTA, unnecessary invasive coronary angiographies (ICAs) are conducted with the costs and risks associated with the procedure. Hence, an optimized diagnostic CAD algorithm may reduce the numbers of ICAs not followed by revascularization. The Dan-NICAD 2 study has 3 equivalent main aims: (1) To examine the diagnostic precision of a sound-based diagnostic algorithm, The CADScor®System (Acarix A/S, Denmark), in patients with a low to intermediate pre-test risk of CAD referred to a primary examination by coronary CTA. We hypothesize that the CADScor®System provides better stratification prior to coronary CTA than clinical risk stratification scores alone. (2) To compare the diagnostic accuracy of 3T cardiac magnetic resonance imaging (3T CMRI), 82rubidium positron emission tomography (82Rb-PET), and CT-derived fractional flow reserve (FFRCT) in patients where obstructive CAD cannot be ruled out by coronary CTA using ICA fractional flow reserve (FFR) as reference standard. (3) To compare the diagnostic performance of quantitative flow ratio (QFR) and ICA-FFR in patients with low to intermediate pre-test probability of CAD using 82Rb-PET as reference standard. METHODS: Dan-NICAD 2 is a prospective, multicenter, cross-sectional study including approximately 2,000 patients with low to intermediate pre-test probability of CAD and without previous history of CAD. Patients are referred to coronary CTA because of symptoms suggestive of CAD, as evaluated by a cardiologist. Patient interviews, sound recordings, and blood samples are obtained in connection with the coronary CTA. If coronary CTA does not rule out obstructive CAD, patients will be examined by 3T CMRI 82Rb-PET, FFRCT, ICA, and FFR. Reference standard is ICA-FFR. Obstructive CAD is defined as an FFR ≤0.80 or as high-grade stenosis (>90% diameter stenosis) by visual assessment. Diagnostic performance will be evaluated as sensitivity, specificity, predictive values, likelihood ratios, calibration, and discrimination. Enrolment started January 2018 and is expected to be completed by June 2020. Patients are followed for 10 years after inclusion. DISCUSSION: The results of the Dan-NICAD 2 study are expected to contribute to the improvement of diagnostic strategies for patients suspected of CAD in 3 different steps: risk stratification prior to coronary CTA, diagnostic strategy after coronary CTA, and invasive wireless QFR analysis as an alternative to ICA-FFR.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Reserva del Flujo Fraccional Miocárdico/fisiología , Imagen por Resonancia Cinemagnética/métodos , Tomografía Computarizada Multidetector/métodos , Tomografía de Emisión de Positrones/métodos , Adulto , Enfermedad de la Arteria Coronaria/fisiopatología , Estudios Transversales , Dinamarca , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados
11.
Eur J Nucl Med Mol Imaging ; 46(1): 184-193, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30066157

RESUMEN

PURPOSE: To estimate the diagnostic accuracy of conventional 18F-FDG PET/CT of cranial arteries in the diagnosis of giant cell arteritis (GCA). METHODS: The study was a retrospective case-control study. The reference diagnosis was fulfillment of the 1990 ACR criteria for GCA. All patients had new-onset GCA. Conventional 18F-FDG PET/CT was performed before glucocorticoid treatment. Controls were age- and sex-matched patients with a previous history of malignant melanoma (MM) undergoing surveillance PET/CT >6 months after MM resection. PET images were evenly cropped to include only head and neck and were assessed in random order by four nuclear medicine physicians blinded to reference diagnosis. Temporal (TA), maxillary (MA) and vertebral (VA) arteries were visually rated for 18F-FDG uptake. Interreader agreement was evaluated by Fleiss kappa. RESULTS: A total of 44 patients and 44 controls were identified. In both groups, the mean age was 69 years (p = 0.45) and 25/44 were women. 35/41 GCA patients were temporal artery biopsy positive (TAB). Considering only FDG uptake in TA and/or MA, diagnostic sensitivity and specificity was 64 and 100%. Including VA, sensitivity increased to 82% and specificity remained 100%. Interreader agreement was 91% and Fleiss kappa 0.82 for the PET diagnosis based on the cranial arteries. CONCLUSION: Conventional 18F-FDG PET/CT is an accurate and reliable tool to diagnose cranial arteritis in glucocorticoid-naïve GCA patients. The high diagnostic specificity suggests that TAB can be omitted in patients with 18F-FDG uptake in cranial arteries. 18F-FDG PET/CT performed in patients with suspected vasculitis should always include the head and neck.


Asunto(s)
Arteritis de Células Gigantes/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas , Anciano , Estudios de Casos y Controles , Femenino , Fluorodesoxiglucosa F18 , Arteritis de Células Gigantes/patología , Humanos , Inflamación , Masculino , Variaciones Dependientes del Observador , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos , Sensibilidad y Especificidad
12.
Acta Oncol ; 57(8): 1063-1069, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29447047

RESUMEN

AIM: To compare 18F-sodium fluoride positron emission tomography/computed tomography (NaF PET/CT) and 99mTc-labelled diphosphonate bone scan (BS) for the monitoring of bone metastases in patients with prostate cancer undergoing anti-cancer treatment. MATERIAL AND METHODS: Data from 64 patients with prostate cancer were included. The patients received androgen-deprivation therapy (ADT), next-generation hormonal therapy (NGH) or chemotherapy. The patients had a baseline scan and 1-3 subsequent scans during six months of treatment. Images were evaluated by experienced nuclear medicine physicians and classified for progressive disease (PD) or non-PD according to the Prostate Cancer Working Group 2 (PCWG-2) criteria. The patients were also classified as having PD/non-PD according to the clinical and prostate-specific antigen (PSA) responses. RESULTS: There was no difference between NaF PET/CT and BS in the detection of PD and non-PD during treatment (McNemar's test, p = .18). The agreement between BS and NaF PET/CT for PD/non-PD was moderate (Cohen's kappa 0.53, 95% confidence interval 0.26-0.79). Crude agreement between BS and NaF PET/CT for the assessment of PD/non-PD was 86% (89% for ADT, n = 28; 88% for NGH, n = 16, and 80% for chemotherapy, n = 20). In most discordant cases, BS found PD when NaF PET/CT did not, or BS detected PD on an earlier scan than NaF PET/CT. Biochemical progression (27%) occurred more frequently than progression on functional imaging (BS, 22% and NaF PET/CT, 14%). Clinical progression was rare (11%), and almost exclusively seen in patients receiving chemotherapy. CONCLUSION: There was no difference between NaF PET/CT and BS in the detection of PD and non-PD; however, BS seemingly detects PD by the PCWG-2 criteria earlier than NaF-PET, which might be explained by the fact that NaF-PET is more sensitive at the baseline scan.


Asunto(s)
Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/secundario , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata/patología , Cintigrafía/métodos , Anciano , Anciano de 80 o más Años , Radioisótopos de Flúor , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Neoplasias de la Próstata/tratamiento farmacológico , Radiofármacos , Fluoruro de Sodio , Resultado del Tratamiento
13.
Trials ; 17(1): 262, 2016 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-27225018

RESUMEN

BACKGROUND: Coronary computed tomography angiography (CCTA) is an established method for ruling out coronary artery disease (CAD). Most patients referred for CCTA do not have CAD and only approximately 20-30 % of patients are subsequently referred to further testing by invasive coronary angiography (ICA) or non-invasive perfusion evaluation due to suspected obstructive CAD. In cases with severe calcifications, a discrepancy between CCTA and ICA often occurs, leading to the well-described, low-diagnostic specificity of CCTA. As ICA is cost consuming and involves a risk of complications, an optimized algorithm would be valuable and could decrease the number of ICAs that do not lead to revascularization. The primary objective of the Dan-NICAD study is to determine the diagnostic accuracy of cardiac magnetic resonance imaging (CMRI) and myocardial perfusion scintigraphy (MPS) as secondary tests after a primary CCTA where CAD could not be ruled out. The secondary objective includes an evaluation of the diagnostic precision of an acoustic technology that analyses the sound of coronary blood flow. It may potentially provide better stratification prior to CCTA than clinical risk stratification scores alone. METHODS/DESIGN: Dan-NICAD is a multi-centre, randomised, cross-sectional trial, which will include approximately 2,000 patients without known CAD, who were referred to CCTA due to a history of symptoms suggestive of CAD and a low-risk to intermediate-risk profile, as evaluated by a cardiologist. Patient interview, sound recordings, and blood samples are obtained in connection with the CCTA. All patients with suspected obstructive CAD by CCTA are randomised to either stress CMRI or stress MPS, followed by ICA with fractional flow reserve (FFR) measurements. Obstructive CAD is defined as an FFR below 0.80 or as high-grade stenosis (>90 % diameter stenosis) by visual assessment. Diagnostic performance is evaluated as sensitivity, specificity, predictive values, likelihood ratios, and C statistics. Enrolment commenced in September 2014 and is expected to be complete in May 2016. DISCUSSION: Dan-NICAD is designed to assess whether a secondary perfusion examination after CCTA could safely reduce the number of ICAs where revascularization is not required. The results are expected to add knowledge about the optimal algorithm for diagnosing CAD. TRIAL REGISTRATION: Clinicaltrials.gov identifier, NCT02264717 . Registered on 26 September 2014.


Asunto(s)
Protocolos Clínicos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Estudios Transversales , Reserva del Flujo Fraccional Miocárdico , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética
14.
Acta Cardiol ; 69(1): 15-22, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24640517

RESUMEN

OBJECTIVE: 2D strain analysis based on speckle tracking (EchoPAC, GE) allows semi-automatic quantification of myocardial deformation. Microbubble contrast (MBC) alters the speckle pattern, but the impact of MBC on speckle tracking has not been thoroughly studied. We investigated whether 2D strain analysis performed on contrast-enhanced recordings obtained with a normal mechanical index (MI) was possible, and evaluated if and how strain measurements and speckle tracking were affected by MBC. METHODS AND RESULTS: Twenty-nine patients with normal echocardiograms were consecutively included and divided into two groups dependent on image quality (19 with high (HIQ) and 10 with low image quality (LIQ)). Before, during, three and seven minutes after MBC infusion (SonoVue, Bracco), the three standard apical loops were recorded (MI = 1.0) and analysed twice on two different days. Mean and regional (basal, mid-ventricular and apical) leftventricular peak systolic strain were calculated at each time point. No significant changes over time were detected in mean or regional strain. Reproducibility worsened during and three minutes after MBC infusion and was generally poorer in the LIQ group. Tracking was impaired during MBC for the HIQ group, but improved throughout the examination for the LIQ group. CONCLUSIONS: First, it was possible to quantify 2D strain from recordings obtained during or shortly after MBC infusion. Secondly, 2D strain measures were unaffected by the presence of MBC, and, thirdly, the reproducibility and the performance of the tracking algorithm were impaired when high intensities of MBC were present in the circulation.


Asunto(s)
Angina Estable , Ecocardiografía/métodos , Microburbujas , Anciano , Algoritmos , Angina Estable/diagnóstico , Angina Estable/fisiopatología , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Miocardio/patología , Reproducibilidad de los Resultados , Volumen Sistólico , Factores de Tiempo , Función Ventricular Izquierda
15.
EJNMMI Res ; 3(1): 15, 2013 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-23497537

RESUMEN

BACKGROUND: Phosphatidylserine (PS) is a phospholipid normally located in the inner leaflet of the cell membrane. PS is translocated from the inner to the outer leaflet of the plasma membrane during the early stages of apoptosis and in necrosis. In cell and animal studies, reversible PS externalisation to the outer membrane leaflet has been observed in viable cells. Hence, PS markers have been proposed as markers of both reversibly and irreversibly damaged cells. The purpose of this experimental study in pigs was to investigate the kinetics of the newly introduced PS marker technetium-99m-labelled lactadherin (99mTc-lactadherin) in comparison with the well-known PS tracer 99mTc-annexin V with special reference to the renal handling of the tracers. The effective dose for humans was estimated from the biodistribution in 24 mice. METHODS: Nine anaesthetised pigs randomly allocated into two treatment groups were administered a single injection of either 99mTc-lactadherin or 99mTc-annexin V. Renal perfusion was assessed by simultaneous injection of 51Cr-EDTA. Throughout the examinations, planar, dynamic scintigraphy of the trunk was performed, urine was collected and arterial and renal vein blood was sampled. The effective dose was estimated using the adult male phantom from the RADAR website. RESULTS: 99mTc-lactadherin was cleared four times faster from plasma than 99mTc-annexin V, 57 ± 13 ml/min (mean ± SD) versus 14 ± 2 ml/min. 99mTc-lactadherin had a predominant uptake in the liver, whereas 99mTc-annexin V was primarily taken up by the kidneys. The estimated effective human dose after single injection of 99mTc-lactadherin and 99mTc-annexin V was 5.8 and 11 µSv/MBq, respectively. CONCLUSIONS: The high hepatic uptake of 99mTc-lactadherin compromises the use of 99mTc-lactadherin for imaging PS externalisation in the liver. Due to scatter from the liver, the use of in vivo visualisation of PS externalisation in the lower thorax and upper abdomen by 99mTc-lactadherin is challenged, but not precluded. In contrast to 99mTc-annexin, 99mTc-lactadherin has a low renal uptake and may be the preferred tracer for imaging PS externalisation in the kidneys. The effective dose after injection of 99mTc-lactadherin and 99mTc-annexin was low. Recommendations regarding the clinical use of 99mTc-lactadherin must await tracer kinetic studies in patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...