Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Fluoresc ; 24(1): 85-91, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23900846

RESUMEN

A highly sensitive and simple spectrofluorimetric method was developed for the determination of cyproheptadine hydrochloride (CYP) in its pharmaceutical formulations. The proposed method is based on the investigation of the fluorescence spectral behaviour of CYP in a sodium dodecyl sulphate (SDS) micellar system. In aqueous solution, the fluorescence intensity of CYP was greatly enhanced (150 %) in the presence of SDS. The fluorescence intensity was measured at 410 nm after excitation at 280 nm. The fluorescence-concentration plot was rectilinear over the range 0.2-2.0 µg/mL, with lower detection limit of 0.06 µg/mL. The proposed method was successfully applied to the assay of commercial tablets as well as content uniformity testing. The application of the proposed method was extended to test the in-vitro drug release of CYP tablets, according to USP guidelines. The results were statistically compared with those obtained by official USP method and were found to be in good agreement.


Asunto(s)
Ciproheptadina/análisis , Micelas , Espectrometría de Fluorescencia , Comprimidos/química
2.
J Fluoresc ; 23(5): 1077-87, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23722995

RESUMEN

A highly sensitive, simple and rapid spectrofluorimetric method was developed for the determination of Terbinafine HCl (TRH) and linezolid (LNZ) in their pharmaceutical formulations. The proposed method is based on measuring the native fluorescence of the studied drugs in water at 336 nm after excitation at 275 nm for TRH and 375 nm after excitation at 254 nm for LNZ. The fluorescence-concentration plots were rectilinear over the range of 0.02-0.15 µg/mL for TRH and 0.5-5.0 µg/mL for LNZ. With lower detection limits of 3.0 and 110.0 ng/mL and a lower quantification limit of 9.0 and 320.0 ng/mL for TRH and LNZ, respectively. The method was successfully applied to the analysis of TRH in its commercial tablets, cream, gel and spray formulations and the results were in good agreement with those obtained with the official method. In addition the method was also applied to the analysis of LNZ in its capsule and I.V solution and the results were in good agreement with those obtained with the comparison method. The effect of sensitizers was studied. The method was extended to the determination of the studied drugs in spiked human plasma and the results were satisfactory.


Asunto(s)
Acetamidas/sangre , Naftalenos/sangre , Oxazolidinonas/sangre , Humanos , Linezolid , Estructura Molecular , Espectrometría de Fluorescencia , Terbinafina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA