Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Comput Methods Programs Biomed ; 254: 108298, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38936154

RESUMEN

BACKGROUND: Synchronous acquisition of haemodynamic signals is crucial for their multimodal analysis, such as dynamic cerebral autoregulation (DCA) analysis of arterial blood pressure (ABP) and transcranial Doppler (TCD)-derived cerebral blood velocity (CBv). Several technical problems can, however, lead to (varying) time-shifts between the different signals. These can be difficult to recognise and can strongly influence the multimodal analysis results. METHODS: We have developed a multistep, cross-correlation-based time-shift detection and synchronisation algorithm for multimodal pulsatile haemodynamic signals. We have developed the algorithm using ABP and CBv measurements from a dataset that contained combinations of several time-shifts. We validated the algorithm on an external dataset with time-shifts. We additionally quantitatively validated the algorithm's performance on a dataset with artificially added time-shifts, consisting of sample clock differences ranging from -0.2 to 0.2 s/min and sudden time-shifts between -4 and 4 s. The influence of superimposed noise and variation in waveform morphology on the time-shift estimation was quantified, and their influence on DCA-indices was determined. RESULTS: The instantaneous median absolute error (MedAE) between the artificially added time-shifts and the estimated time-shifts was 12 ms (median, IQR 12-12, range 11-14 ms) for drifts between -0.1 and 0.1 s/min and sudden time-shifts between -4 and 4 s. For drifts above 0.1 s/min, MedAE was higher (median 753, IQR 19 - 766, range 13 - 772 ms). When a certainty threshold was included (peak cross-correlation > 0.9), MedAE for all drifts-shift combinations decreased to 12 ms, with smaller variability (IQR 12 - 13, range 8 - 22 ms, p < 0.001). The time-shift estimation is robust to noise, as the MedAE was similar for superimposed white noise with variance equal to the signal variance. After time-shift correction, DCA-indices were similar to the original, non-time-shifted signals. Phase shift differed by 0.17° (median, IQR 0.13-0.2°, range 0.0038-1.1°) and 0.54° (median, IQR 0.23-1.7°, range 0.0088-5.6°) for the very low frequency and low frequency ranges, respectively. DISCUSSION: This algorithm allows visually interpretable detection and accurate correction of time-shifts between pulsatile haemodynamic signals (ABP and CBv).

2.
J Clin Med ; 12(8)2023 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-37109113

RESUMEN

Near-infrared spectroscopy (NIRS) is a non-invasive technique for measuring regional tissue haemoglobin (Hb) concentrations and oxygen saturation (rSO2). It may be used to monitor cerebral perfusion and oxygenation in patients at risk of cerebral ischemia or hypoxia, for example, during cardiothoracic or carotid surgery. However, extracerebral tissue (mainly scalp and skull tissue) influences NIRS measurements, and the extent of this influence is not clear. Thus, before more widespread use of NIRS as an intraoperative monitoring modality is warranted, this issue needs to be better understood. We therefore conducted a systematic review of published in vivo studies of the influence of extracerebral tissue on NIRS measurements in the adult population. Studies that used reference techniques for the perfusion of the intra- and extracerebral tissues or that selectively altered the intra- or extracerebral perfusion were included. Thirty-four articles met the inclusion criteria and were of sufficient quality. In 14 articles, Hb concentrations were compared directly with measurements from reference techniques, using correlation coefficients. When the intracerebral perfusion was altered, the correlations between Hb concentrations and intracerebral reference technique measurements ranged between |r| = 0.45-0.88. When the extracerebral perfusion was altered, correlations between Hb concentrations and extracerebral reference technique measurements ranged between |r| = 0.22-0.93. In studies without selective perfusion modification, correlations of Hb with intra- and extracerebral reference technique measurements were generally lower (|r| < 0.52). Five articles studied rSO2. There were varying correlations of rSO2 with both intra- and extracerebral reference technique measurements (intracerebral: |r| = 0.18-0.77, extracerebral: |r| = 0.13-0.81). Regarding study quality, details on the domains, participant selection and flow and timing were often unclear. We conclude that extracerebral tissue indeed influences NIRS measurements, although the evidence (i.e., correlation) for this influence varies considerably across the assessed studies. These results are strongly affected by the study protocols and analysis techniques used. Studies employing multiple protocols and reference techniques for both intra- and extracerebral tissues are therefore needed. To quantitatively compare NIRS with intra- and extracerebral reference techniques, we recommend applying a complete regression analysis. The current uncertainty regarding the influence of extracerebral tissue remains a hurdle in the clinical implementation of NIRS for intraoperative monitoring. The protocol was pre-registered in PROSPERO (CRD42020199053).

3.
Eur Stroke J ; 7(4): 384-392, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36478755

RESUMEN

Introduction: The aim of endovascular treatment (EVT) for acute ischaemic stroke is to relieve the cerebral tissue hypoxia in the area supplied by the occluded artery. Near-infrared spectroscopy (NIRS) monitoring is developed to assess regional cerebral tissue oxygen haemoglobin saturation (rSO2). We aimed to investigate whether NIRS can detect inter- and intra-hemispheric rSO2 differences during EVT. Patients and methods: In this prospective, observational study, patients undergoing EVT for a proximal intracranial occlusion of the anterior circulation between May 2019 and November 2020, were included. A four-wavelength NIRS monitor (O3® Regional Oximeter (Masimo, Irvine, CA)) was used to measure rSO2 during EVT with sensors placed over the temporal lobes in 20 patients and over the frontal lobes in 13 patients. The Wilcoxon signed-rank test was used to test for inter-hemispheric rSO2 differences after groin puncture and after recanalisation, and intra-hemispheric rSO2 changes before and after recanalisation. Results: In the temporal cohort, no inter-hemispheric rSO2 differences were observed after groin puncture (median [IQR] rSO2 affected hemisphere, 70% [67-73] and unaffected hemisphere, 70% [66-72]; p = 0.79) and after recanalisation. There were no intra-hemispheric rSO2 changes over time. In the frontal cohort, no inter- and intra-hemispheric rSO2 differences or changes were found. Discussion and conclusion: A NIRS monitor could not detect inter- and intra-hemispheric rSO2 differences or changes during EVT, irrespective of the sensor position. It is likely that even with temporal sensor application, a significant proportion of the received NIRS signal was influenced by oxygenation of surrounding tissues.

4.
Cells ; 11(14)2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-35883697

RESUMEN

Impairments in cerebral autoregulation (CA) are related to poor clinical outcome. Near infrared spectroscopy (NIRS) is a non-invasive technique applied to estimate CA. Our general purpose was to study the clinical feasibility of a previously published 'NIRS-only' CA methodology in a critically ill intensive care unit (ICU) population and determine its relationship with clinical outcome. Bilateral NIRS measurements were performed for 1-2 h. Data segments of ten-minutes were used to calculate transfer function analyses (TFA) CA estimates between high frequency oxyhemoglobin (oxyHb) and deoxyhemoglobin (deoxyHb) signals. The phase shift was corrected for serial time shifts. Criteria were defined to select TFA phase plot segments (segments) with 'high-pass filter' characteristics. In 54 patients, 490 out of 729 segments were automatically selected (67%). In 34 primary neurology patients the median (q1-q3) low frequency (LF) phase shift was higher in 19 survivors compared to 15 non-survivors (13° (6.3-35) versus 0.83° (-2.8-13), p = 0.0167). CA estimation using the NIRS-only methodology seems feasible in an ICU population using segment selection for more robust and consistent CA estimations. The 'NIRS-only' methodology needs further validation, but has the advantage of being non-invasive without the need for arterial blood pressure monitoring.


Asunto(s)
Circulación Cerebrovascular , Espectroscopía Infrarroja Corta , Enfermedad Crítica , Estudios Transversales , Homeostasis/fisiología , Humanos , Estudios Prospectivos , Espectroscopía Infrarroja Corta/métodos
5.
Front Neurol ; 12: 695705, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34566840

RESUMEN

Cerebral perfusion may be altered in sepsis patients. However, there are conflicting findings on cerebral autoregulation (CA) in healthy participants undergoing the experimental endotoxemia protocol, a proxy for systemic inflammation in sepsis. In the current study, a newly developed near-infrared spectroscopy (NIRS)-based CA index is investigated in an endotoxemia study population, together with an index of focal cerebral oxygenation. Methods: Continuous-wave NIRS data were obtained from 11 healthy participants receiving a continuous infusion of bacterial endotoxin for 3 h (ClinicalTrials.gov NCT02922673) under extensive physiological monitoring. Oxygenated-deoxygenated hemoglobin phase differences in the (very)low frequency (VLF/LF) bands and the Tissue Saturation Index (TSI) were calculated at baseline, during systemic inflammation, and at the end of the experiment 7 h after the initiation of endotoxin administration. Results: The median (inter-quartile range) LF phase difference was 16.2° (3.0-52.6°) at baseline and decreased to 3.9° (2.0-8.8°) at systemic inflammation (p = 0.03). The LF phase difference increased from systemic inflammation to 27.6° (12.7-67.5°) at the end of the experiment (p = 0.005). No significant changes in VLF phase difference were observed. The TSI (mean ± SD) increased from 63.7 ± 3.4% at baseline to 66.5 ± 2.8% during systemic inflammation (p = 0.03) and remained higher at the end of the experiment (67.1 ± 4.2%, p = 0.04). Further analysis did not reveal a major influence of changes in several covariates such as blood pressure, heart rate, PaCO2, and temperature, although some degree of interaction could not be excluded. Discussion: A reversible decrease in NIRS-derived cerebral autoregulation phase difference was seen after endotoxin infusion, with a small, sustained increase in TSI. These findings suggest that endotoxin administration in healthy participants reversibly impairs CA, accompanied by sustained microvascular vasodilation.

6.
Front Neurosci ; 12: 350, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29910705

RESUMEN

In this paper various types of electrodes for stimulation and recording activity of peripheral nerves for the control of neuroprosthetic limbs are reviewed. First, an overview of interface devices for (feedback-) controlled movement of a prosthetic device is given, after which the focus is on peripheral nervous system (PNS) electrodes. Important electrode properties, i.e., longevity and spatial resolution, are defined based upon the usability for neuroprostheses. The cuff electrode, longitudinal intrafascicular electrodes (LIFE), transverse intrafascicular multichannel electrode (TIME), Utah slanted electrode array (USEA), and the regenerative electrode are discussed and assessed on their longevity and spatial resolution. The cuff electrode seems to be a promising electrode for the control of neuroprostheses in the near future, because it shows the best longevity and good spatial resolution and it has been used on human subjects in multiple studies. The other electrodes may be promising in the future, but further research on their longevity and spatial resolution is needed. A more quantitatively uniform study protocol used for all electrodes would allow for a proper comparison of recording and stimulation performance. For example, the discussed electrodes could be compared in a large in vivo study, using one uniform comparison protocol.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...