Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
ASAIO J ; 68(9): 1182-1190, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-34967787

RESUMEN

Data are limited regarding body mass index (BMI) in pediatric patients supported by ventricular assist devices (VAD) and associated clinical outcomes and complications. We performed a retrospective single-center cohort study including patients aged ≤21 years on durable continuous-flow VAD support for ≥30 days from 2009 to 2020. Patients were classified based on BMI percentile at implant using the US Centers for Disease Control and Prevention criteria: underweight (<5th percentile), healthy weight (5th-<85th percentile, reference group), overweight (85th-<95th percentile), and obese (≥95th percentile). Primary outcomes were hospital mortality and length of stay (LOS) after implant. Secondary outcomes included infectious complications and pump thrombosis. Seventy-two patients (58 HeartWare, 13 HeartMateII, 1 HeartMate3) were included. At implant, the study cohort comprised 13% underweight, 53% healthy weight, 18% overweight, and 17% obese. BMI increased across all categories during support, with 29% gaining BMI categories. No patients with obesity reduced their BMI category. At explant, the study cohort comprised 1% underweight, 54% healthy weight, 22% overweight, and 22% obese. There was no significant difference in hospital mortality, postoperative LOS, or pump thrombosis. Patients who were overweight had more frequent non-VAD infections. Patients with obesity required longer duration on VAD support and were less likely to be transplanted. We concluded that pediatric patients on VAD support who are overweight or have obesity do not improve their BMI and instead have significant increase. Larger studies are needed to assess the impact of abnormal BMI on VAD complications in pediatric patients.


Asunto(s)
Corazón Auxiliar , Sobrepeso , Índice de Masa Corporal , Niño , Estudios de Cohortes , Corazón Auxiliar/efectos adversos , Humanos , Obesidad/complicaciones , Sobrepeso/complicaciones , Estudios Retrospectivos , Delgadez/complicaciones
2.
Children (Basel) ; 8(6)2021 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-34199474

RESUMEN

Heart failure is a life-changing diagnosis for a child and their family. Pediatric patients with heart failure experience significant morbidity and frequent hospitalizations, and many require advanced therapies such as mechanical circulatory support and/or heart transplantation. Pediatric palliative care is an integral resource for the care of patients with heart failure along its continuum. This includes support during the grief of a new diagnosis in a child critically ill with decompensated heart failure, discussion of goals of care and the complexities of mechanical circulatory support, the pensive wait for heart transplantation, and symptom management and psychosocial support throughout the journey. In this article, we discuss the scope of pediatric palliative care in the realm of pediatric heart failure, ventricular assist device (VAD) support, and heart transplantation. We review the limited, albeit growing, literature in this field, with an added focus on difficult conversation and decision support surrounding re-transplantation, HF in young adults with congenital heart disease, the possibility of destination therapy VAD, and the grimmest decision of VAD de-activation.

3.
ASAIO J ; 67(9): 1036-1043, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-33470634

RESUMEN

The Jarvik 2015 Ventricular Assist Device (VAD) (Jarvik Inc, New York, NY) is the first and currently only continuous-flow VAD specifically designed for small children, and it is being evaluated in the so-called Pump for Kids, Infants, and Neonates (PumpKIN) trial. Due to the strict inclusion criteria of the trial, there have been a group of patients who failed to meet the criteria and therefore received the Jarvik 2015 VAD under the designation of "compassionate use." This is the same phenomenon seen previously during the Berlin Heart EXCOR trial. While we await the results of the PumpKIN trial, which will report the device performance in a strictly selected population, the compassionate use cases represent actual "real world" experiences. We describe herein our experience of two compassionate use cases. In particular, this report has a special emphasis on the power consumption and hemolysis and inflammatory lab profile of the Jarvik 2015 VAD as hemocompatibility was the primary focus of the developmental and the preclinical phases.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Niño , Ensayos Clínicos como Asunto , Insuficiencia Cardíaca/cirugía , Hemólisis , Humanos , Lactante , Recién Nacido
5.
Ann Thorac Surg ; 107(3): 829-836, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30296425

RESUMEN

BACKGROUND: We reviewed our single institutional experience with pediatric ventricular assist device (VAD) support over the last 2 decades, with an aim to improve our current management and gain an insight into the future direction. METHODS: A retrospective review was conducted on all patients that had undergone VAD support between 1996 and 2017. Outcomes were analyzed based on the type of VADs, whether temporary or durable devices. Primary end points were positive outcomes, including bridge-to-transplantation, bridge-to-recovery, alive on device, and bridge-to-bridge to another VAD, or negative outcomes, including death during VAD support or in-hospital death after bridge-to-recovery. The Pediatric Interagency Registry for Mechanical Circulatory Support definition was used to classify adverse events. RESULTS: Overall, 201 VADs were implanted in 159 patients, with 82 (41%) and 119 (59%) being temporary and durable support, respectively. There has been a trend toward an increasing annual implant volume both with temporary and durable VADs. Positive outcomes were achieved in 80% (66 of 82) of those with temporary support, with bridge-to-recovery (53% [35 of 66]) and bridge-to-bridge to another VAD (38% [25 of 66]) being the predominant outcomes. Of those on durable support, 84% (100 of 119) achieved positive outcomes, with bridge-to-transplant (66% [78 of 119]) being the leading destination. The most notable change during the study period was the introduction of implantable continuous-flow VADs, resulting in outpatient management becoming a routine practice. No patients were discharged on VAD support before 2004, but 85% were discharged on VADs with discharge capability after 2013. CONCLUSIONS: The present study has demonstrated the evolutional changes of pediatric VAD support and their effect on clinical outcomes over the last 2 decades.


Asunto(s)
Cardiopatías Congénitas/cirugía , Ventrículos Cardíacos/cirugía , Corazón Auxiliar , Hospitales Pediátricos , Sistema de Registros , Adolescente , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
6.
ASAIO J ; 65(7): 725-730, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30161035

RESUMEN

Despite increasing continuous-flow ventricular assist device (CF-VAD) use in children, minimal data exist regarding the functional recovery and rehabilitation potential after device placement. We hypothesized that after CF-VAD implantation, children would demonstrate a time-limited improvement in 6 minute walk distance (6MWD) and brain-type natriuretic peptide (BNP). A retrospective cohort study of 27 patients was conducted, those <18 years of age at a tertiary-care center during the study period. Seventy-four percent were male; median age was 12.7 years. Six minute walk distance and BNP were evaluated within 365 days of implantation. Associations were examined before and after 90 days postimplantation because a plateau in both values was seen after 90 days. Data included 92 6MWD and 341 BNP values. In the first 90 days, 6MWD increased by 12 percent predicted (%P) per 30 days (P < 0.01); with no significant change thereafter, increasing 0.6 %P per 30 days (P = 0.482). In the first 90 days, BNP decreased by 59% per 30 days (P < 0.01); with no significant change thereafter, increasing 1.2% per 30 days (P = 0.561). Six minute walk distance and BNP improved after CF-VAD implantation, with a significant improvement only in the first 90 days. Routine use of 6MWD and BNP can help in assessment of functional recovery in children after CF-VAD placement.


Asunto(s)
Corazón Auxiliar , Péptido Natriurético Encefálico/sangre , Caminata , Adolescente , Niño , Femenino , Humanos , Masculino , Estudios Retrospectivos , Factores de Tiempo
9.
Tex Heart Inst J ; 44(1): 66-69, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28265217

RESUMEN

We describe the case of a teenage girl with anthracycline-induced cardiomyopathy who received a HeartWare ventricular assist device and underwent successful device explantation after cardiac recovery. During device support, the patient's cardiac function returned to normal. Twelve months after implantation, we explanted the device via repeat median sternotomy. To close the hole in the left ventricular apex and preserve the sewing ring in case future device support is needed, we used a German-manufactured titanium plug, developed specifically for this purpose. To our knowledge, this is the first use of this plug in the United States. The patient recovered uneventfully and was discharged from the hospital on postoperative day 11. Left ventricular biopsy specimens at explantation revealed the resolution of previous degenerative sarcomeric changes. Our patient did well clinically; however, recurrent late anthracycline cardiotoxicity might subsequently cause her cardiac function to deteriorate. In this event, our use of the titanium plug to preserve the left ventricular sewing ring would enable easier device replacement than would other explantation options.


Asunto(s)
Antraciclinas/efectos adversos , Antibióticos Antineoplásicos/efectos adversos , Cardiomiopatías/terapia , Remoción de Dispositivos , Corazón Auxiliar , Implantación de Prótesis/instrumentación , Dispositivos de Fijación Quirúrgicos , Titanio , Técnicas de Cierre de Heridas/instrumentación , Adolescente , Cardiomiopatías/inducido químicamente , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Cardiotoxicidad , Femenino , Humanos , Diseño de Prótesis , Recuperación de la Función , Volumen Sistólico , Resultado del Tratamiento , Estados Unidos , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA