Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Am Surg ; 90(6): 1195-1201, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38205662

RESUMEN

BACKGROUND: Previous studies evaluating whether recent cholecystectomy is associated with a pancreas cancer diagnosis are limited. We aimed to examine if cholecystectomy was performed more frequently in the year prior to cancer diagnosis than would be expected in a similar non-cancer population. METHODS: SEER-Medicare linked files were used to identify patients with pancreatic adenocarcinoma. Cancer diagnoses were considered to be "timely" if within 2 months of cholecystectomy or "delayed" if 2-12 months after cholecystectomy. Clinical factors and survival outcomes were compared using chi-square and Kaplan-Meier analyses. RESULTS: Rate of cholecystectomy in the year prior to diagnosis of cancer was 1.9% for the cancer group, compared to .4% in the non-cancer group (OR = 4.7, 95% CI 4.4-5.1). Differences in the cancer vs non-cancer cohorts at the time of cholecystectomy included a higher age (74 vs 70, P < .0001), more males (49.9% vs 41.7%, P < .0001), and more frequent open technique (21.0% vs 9.4%, P < .0001). Acute pancreatitis was nearly twice as common in the cancer cohort (19.1%) vs the non-cancer cohort (10.7%), P < .0001. There were no differences between patients who had a timely diagnosis after cholecystectomy compared to a delayed diagnosis with regard to age, gender, comorbidity index, race, or rural/urban designation. The rates of localized disease and subsequent resection were also similar between the delayed and timely groups. Overall unadjusted survival was no different between timely and delayed diagnoses, P = .96. DISCUSSION: Elderly patients diagnosed with pancreatic adenocarcinoma are more likely to have had a recent cholecystectomy compared to those without.


Asunto(s)
Adenocarcinoma , Colecistectomía , Neoplasias Pancreáticas , Programa de VERF , Humanos , Neoplasias Pancreáticas/cirugía , Neoplasias Pancreáticas/mortalidad , Neoplasias Pancreáticas/diagnóstico , Anciano , Masculino , Femenino , Anciano de 80 o más Años , Adenocarcinoma/cirugía , Adenocarcinoma/mortalidad , Adenocarcinoma/diagnóstico , Estados Unidos/epidemiología , Estudios Retrospectivos , Factores de Tiempo , Estimación de Kaplan-Meier , Medicare
2.
Dev Cogn Neurosci ; 60: 101203, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36791555

RESUMEN

The hippocampus, critical for learning and memory, undergoes substantial changes early in life. Investigating the developmental trajectory of hippocampal structure and function requires an accurate method for segmenting this region from anatomical MRI scans. Although manual segmentation is regarded as the "gold standard" approach, it is laborious and subjective. This has fueled the pursuit of automated segmentation methods in adults. However, little is known about the reliability of these automated protocols in infants, particularly when anatomical scan quality is degraded by head motion or the use of shorter and quieter infant-friendly sequences. During a task-based fMRI protocol, we collected quiet T1-weighted anatomical scans from 42 sessions with awake infants aged 4-23 months. Two expert tracers first segmented the hippocampus in both hemispheres manually. The resulting inter-rater reliability (IRR) was only moderate, reflecting the difficulty of infant segmentation. We then used four protocols to predict these manual segmentations: average adult template, average infant template, FreeSurfer software, and Automated Segmentation of Hippocampal Subfields (ASHS) software. ASHS generated the most reliable hippocampal segmentations in infants, exceeding the manual IRR of experts. Automated methods thus provide robust hippocampal segmentations of noisy T1-weighted infant scans, opening new possibilities for interrogating early hippocampal development.


Asunto(s)
Hipocampo , Procesamiento de Imagen Asistido por Computador , Adulto , Humanos , Lactante , Reproducibilidad de los Resultados , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos
3.
Nat Commun ; 11(1): 4523, 2020 09 09.
Artículo en Inglés | MEDLINE | ID: mdl-32908125

RESUMEN

Thousands of functional magnetic resonance imaging (fMRI) studies have provided important insight into the human brain. However, only a handful of these studies tested infants while they were awake, because of the significant and unique methodological challenges involved. We report our efforts to address these challenges, with the goal of creating methods for awake infant fMRI that can reveal the inner workings of the developing, preverbal mind. We use these methods to collect and analyze two fMRI datasets obtained from infants during cognitive tasks, released publicly with this paper. In these datasets, we explore and evaluate data quantity and quality, task-evoked activity, and preprocessing decisions. We disseminate these methods by sharing two software packages that integrate infant-friendly cognitive tasks and eye-gaze monitoring with fMRI acquisition and analysis. These resources make fMRI a feasible and accessible technique for cognitive neuroscience in awake and behaving human infants.


Asunto(s)
Mapeo Encefálico/métodos , Encéfalo/diagnóstico por imagen , Desarrollo Infantil/fisiología , Imagen por Resonancia Magnética/métodos , Vigilia/fisiología , Técnicas de Observación Conductual , Encéfalo/crecimiento & desarrollo , Preescolar , Cognición/fisiología , Estudios de Cohortes , Estudios de Factibilidad , Femenino , Humanos , Lactante , Masculino
4.
Phys Rev Lett ; 115(24): 247401, 2015 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-26705653

RESUMEN

We measure the Hall conductivity of a two-dimensional electron gas formed at a GaAs/AlGaAs heterojunction in the terahertz regime close to the cyclotron resonance frequency using highly sensitive Faraday rotation measurements. The sample is electrically gated, allowing the electron density to be changed continuously by more than a factor of 3. We observe clear plateaulike and steplike features in the Faraday rotation angle vs electron density and magnetic field (Landau-level filling factor) even at fields or frequencies very close to cyclotron resonance absorption. These features are the high frequency manifestation of quantum Hall plateaus-a signature of topologically protected edge states. We observe both odd and even filling factor plateaus and explore the temperature dependence of these plateaus. Although dynamical scaling theory begins to break down in the frequency region of our measurements, we find good agreement with theory.

5.
Rev Sci Instrum ; 83(12): 123108, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23277973

RESUMEN

Investigation of magnetic materials using the first-order magneto-optical Kerr effects (MOKEs) is well established and is frequently used. On the other hand, the utilization of the second-order (or quadratic) magneto-optical (MO) effects for the material research is rather rare. This is due to the small magnitude of quadratic MO signals and the fact that the signals are even in magnetization (i.e., they do not change a sign when the magnetization orientation is reversed), which makes it difficult to separate second-order MO signals from various experimental artifacts. In 2005 a giant quadratic MO effect-magnetic linear dichroism (MLD)-was observed in the ferromagnetic semiconductor (Ga,Mn)As. This discovery not only provided a new experimental tool for the investigation of in-plane magnetization dynamics in (Ga,Mn)As using light at normal incidence, but it also motivated the development of experimental techniques for the measurement of second-order MO effects in general. In this paper we compare four different experimental techniques that can be used to measure MLD and to separate it from experimental artifacts. We show that the most reliable results are obtained when we monitor the polarization of reflected light while the magnetization of the sample is rotated by applying an external magnetic field. Using this technique we measure the MLD spectra of (Ga,Mn)As in a broad spectral range from 0.1 eV to 2.7 eV and we observe that MLD has a magnitude comparable to the polar MOKE signals in this material.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...