Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
PLoS One ; 16(5): e0251880, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34019573

RESUMEN

OBJECTIVE: To develop and assess a novel guidance technique and instrumentation system for minimally invasive short-stemmed total shoulder arthroplasty that will help to reduce the complications associated with traditional open replacement such as poor muscle healing and neurovascular injury. We have answered key questions about the developed system including (1) can novel patient-specific guides be accurately registered and used within a minimally invasive environment?; (2) can accuracy similar to traditional techniques be achieved? METHODS: A novel intra-articular patient-specific guide was developed for use with a new minimally invasive posterior surgical approach that guides bone preparation without requiring muscle resection or joint dislocation. Additionally, a novel set of instruments were developed to enable bone preparation within the minimally invasive environment. The full procedure was evaluated in six cadaveric shoulders, using digitizations to assess accuracy of each step. RESULTS: Patient-specific guide registration accuracy in 3D translation was 2.2±1.2mm (RMSE±1 SD; p = 0.007) for the humeral component and 2.7±0.7mm (p<0.001) for the scapula component. Final implantation accuracy was 2.9±3.0mm (p = 0.066) in translation and 5.7-6.8±2.2-4.0° (0.001

Asunto(s)
Artritis/cirugía , Artroplastía de Reemplazo de Hombro/métodos , Cuerpos Extraños , Húmero/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Escápula/cirugía , Articulación del Hombro/cirugía , Anciano , Artritis/diagnóstico por imagen , Artritis/patología , Artroplastía de Reemplazo de Hombro/instrumentación , Cadáver , Humanos , Húmero/diagnóstico por imagen , Húmero/patología , Imagenología Tridimensional , Medicina de Precisión , Rango del Movimiento Articular/fisiología , Escápula/diagnóstico por imagen , Escápula/patología , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/patología , Tomografía Computarizada por Rayos X
2.
Dis Model Mech ; 14(3)2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33563616

RESUMEN

Collagen assembly during development is essential for successful matrix mineralisation, which determines bone quality and mechanocompetence. However, the biochemical and structural perturbations that drive pathological skeletal collagen configuration remain unclear. Deletion of vascular endothelial growth factor (VEGF; also known as VEGFA) in bone-forming osteoblasts (OBs) induces sex-specific alterations in extracellular matrix (ECM) conformation and mineralisation coupled to vascular changes, which are augmented in males. Whether this phenotypic dimorphism arises as a result of the divergent control of ECM composition and its subsequent arrangement is unknown and is the focus of this study. Herein, we used murine osteocalcin-specific Vegf knockout (OcnVEGFKO) and performed ex vivo multiscale analysis at the tibiofibular junction of both sexes. Label-free and non-destructive polarisation-resolved second-harmonic generation (p-SHG) microscopy revealed a reduction in collagen fibre number in males following the loss of VEGF, complemented by observable defects in matrix organisation by backscattered electron scanning electron microscopy. This was accompanied by localised divergence in collagen orientation, determined by p-SHG anisotropy measurements, as a result of OcnVEGFKO. Raman spectroscopy confirmed that the effect on collagen was linked to molecular dimorphic VEGF effects on collagen-specific proline and hydroxyproline, and collagen intra-strand stability, in addition to matrix carbonation and mineralisation. Vegf deletion in male and female murine OB cultures in vitro further highlighted divergence in genes regulating local ECM structure, including Adamts2, Spp1, Mmp9 and Lama1. Our results demonstrate the utility of macromolecular imaging and spectroscopic modalities for the detection of collagen arrangement and ECM composition in pathological bone. Linking the sex-specific genetic regulators to matrix signatures could be important for treatment of dimorphic bone disorders that clinically manifest in pathological nano- and macro-level disorganisation. This article has an associated First Person interview with the first author of the paper.


Asunto(s)
Matriz Extracelular , Factor A de Crecimiento Endotelial Vascular , Animales , Huesos/metabolismo , Colágeno/metabolismo , Matriz Extracelular/metabolismo , Femenino , Humanos , Masculino , Ratones , Osteoblastos , Factor A de Crecimiento Endotelial Vascular/metabolismo
3.
J Shoulder Elbow Surg ; 29(10): 1967-1973, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32499200

RESUMEN

BACKGROUND: The critical shoulder angle (CSA) has been shown to be correlated with shoulder disease states. The biomechanical hypothesis to explain this correlation is that the CSA changes the shear and compressive forces on the shoulder. The objective of this study is to test this hypothesis by use of a validated computational shoulder model. Specifically, this study assesses the impact on glenohumeral biomechanics of modifying the CSA. METHODS: An inverse dynamics 3-dimensional musculoskeletal model of the shoulder was used to quantify muscle forces and glenohumeral joint forces. The CSA was changed by altering the attachment point of the middle deltoid into a normal CSA (33°), a reduced CSA of 28°, and an increased CSA of 38°. Subject-specific kinematics of slow and fast speed abduction in the scapular plane and slow and fast forward flexion measured by a 3-dimensional motion capture system were used to quantify joint reaction shear and compressive forces. RESULTS: Increasing the CSA results in increased superior-inferior forces (shearing forces; integrated over the range of motion; P < .05). Reducing CSA results in increased lateromedial (compressive) forces for both the maximum and integrated sum of the forces over the whole motion (P < .01). DISCUSSION/CONCLUSION: Changes in the CSA modify glenohumeral joint biomechanics with increasing CSA producing higher shear forces that could contribute to rotator cuff overuse, whereas reducing the CSA results in higher compressive forces that contribute to joint wear.


Asunto(s)
Fenómenos Biomecánicos , Articulación del Hombro/fisiopatología , Adulto , Simulación por Computador , Humanos , Cinética , Masculino , Modelos Anatómicos , Movimiento , Rango del Movimiento Articular , Estrés Mecánico , Adulto Joven
4.
Matrix Biol Plus ; 5: 100018, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33543015

RESUMEN

Mineralization of bone is achieved by the sequential maturation of the immature amorphous calcium phase to mature hydroxyapatite (HA) and is central in the process of bone development and repair. To study normal and dysregulated mineralization in vitro, substrates are often coated with poly-l-lysine (PLL) which facilitates cell attachment. This study has used Raman spectroscopy to investigate the effect of PLL coating on osteoblast (OB) matrix composition during differentiation, with a focus on collagen specific proline and hydroxyproline and precursors of HA. Deconvolution analysis of murine derived long bone OB Raman spectra revealed collagen species were 4.01-fold higher in OBs grown on PLL. Further, an increase of 1.91-fold in immature mineral species (amorphous calcium phosphate) was coupled with a 9.32-fold reduction in mature mineral species (carbonated apatite) on PLL versus controls. These unique low mineral signatures identified in OBs were linked with reduced alkaline phosphatase enzymatic activity, reduced Alizarin Red staining and altered osteogenic gene expression. The promotion of immature mineral species and restriction of mature mineral species of OB grown on PLL were linked to increased cell viability and pro-angiogenic vascular endothelial growth factor (VEGF) production. These results demonstrate the utility of Raman spectroscopy to link distinct matrix signatures with OB maturation and VEGF release. Importantly, Raman spectroscopy could provide a label-free approach to clinically assess the angiogenic potential of bone during fracture repair or degenerative bone loss.

5.
Shoulder Elbow ; 11(1 Suppl): 19-25, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31019558

RESUMEN

BACKGROUND: Detachment of the central tendon of the supraspinatus from its insertion is considered to be crucial to functional deficit. The aim of the present study was to assess the function of the supraspinatus in terms of abduction moments by introducing different tear configurations to assess the functional effect of the central tendon insertion. METHODS: Ten fresh frozen shoulders from five cadavers were prepared for testing. A testing protocol was established to measure the abduction moment of the supraspinatus under physiological loading tailored to the anthropometrics of each specimen. Four conditions were tested: intact supraspinatus; complete detachment of portion of the supraspinatus tendon anterior to the main central tendon; detachment of the main central tendon; and detachment of the region of the supraspinatus posterior to the main central tendon. RESULTS: There was a significant and large reduction in abduction moment when the central tendon was sectioned (p < 0.05). A smaller reduction in abduction moment was found when the regions anterior and posterior to the main central tendon were sectioned (p < 0.05). CONCLUSIONS: The central tendon is vital in the role of functional arm abduction through force transmission through the intact rotator cuff. Reinsertion of the central tendon in the correct anatomical location is desirable to optimize functional outcome of surgery.

6.
J Shoulder Elbow Surg ; 26(9): 1653-1661, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28495573

RESUMEN

BACKGROUND: Short-stem humeral replacements achieve fixation by anchoring to the metaphyseal trabecular bone. Fixing the implant in high-density bone can provide strong fixation and reduce the risk of loosening. However, there is a lack of data mapping the bone density distribution in the proximal humerus. The aim of the study was to investigate the bone density in proximal humerus. METHODS: Eight computed tomography scans of healthy cadaveric humeri were used to map bone density distribution in the humeral head. The proximal humeral head was divided into 12 slices parallel to the humeral anatomic neck. Each slice was then divided into 4 concentric circles. The slices below the anatomic neck, where short-stem implants have their fixation features, were further divided into radial sectors. The average bone density for each of these regions was calculated, and regions of interest were compared using a repeated-measures analysis of variance with significance set at P < .05. RESULTS: Average apparent bone density was found to decrease from proximal to distal regions, with the majority of higher bone density proximal to the anatomic neck of the humerus (P < .05). Below the anatomic neck, bone density increases from central to peripheral regions, where cortical bone eventually occupies the space (P < .05). In distal slices below the anatomic neck, a higher bone density distribution in the medial calcar region was also observed. CONCLUSION: This study indicates that it is advantageous with respect to implant fixation to preserve some bone above the anatomic neck and epiphyseal plate and to use the denser bone at the periphery.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cabeza Humeral/diagnóstico por imagen , Diseño de Prótesis , Prótesis de Hombro , Anciano , Densidad Ósea , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
7.
J Shoulder Elbow Surg ; 26(3): 512-520, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27745804

RESUMEN

BACKGROUND: The deltopectoral approach for total shoulder arthroplasty can result in subscapularis dysfunction. In addition, glenoid wear is more prevalent posteriorly, a region difficult to access with this approach. We propose a posterior approach for access in total shoulder arthroplasty that uses the internervous interval between the infraspinatus and teres minor. This study compares this internervous posterior approach with other rotator cuff-sparing techniques, namely, the subscapularis-splitting and rotator interval approaches. METHODS: The 3 approaches were performed on 12 fresh frozen cadavers. The degree of circumferential access to the glenohumeral joint, the force exerted on the rotator cuff, the proximity of neurovascular structures, and the depth of the incisions were measured, and digital photographs of the approaches in different arm positions were analyzed. RESULTS: The posterior approach permits direct linear access to 60% of the humeral and 59% of the glenoid joint circumference compared with 39% and 42% for the subscapularis-splitting approach and 37% and 28% for the rotator interval approach. The mean force of retraction on the rotator cuff was 2.76 (standard deviation [SD], 1.10) N with the posterior approach, 2.72 (SD, 1.22) N with the rotator interval, and 4.75 (SD, 2.56) N with the subscapularis-splitting approach. From the digital photographs and depth measurements, the estimated volumetric access available for instrumentation during surgery was comparable for the 3 approaches. CONCLUSION: The internervous posterior approach provides greater access to the shoulder joint while minimizing damage to the rotator cuff.


Asunto(s)
Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Anciano , Anciano de 80 o más Años , Cadáver , Estudios de Factibilidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Fotograbar , Manguito de los Rotadores
9.
J Bone Joint Surg Am ; 96(13): e112, 2014 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-24990986

RESUMEN

BACKGROUND: Surgical training is undergoing major changes with reduced resident work hours and an increasing focus on patient safety and surgical aptitude. The aim of this study was to create a valid, reliable method for an assessment of arthroscopic skills that is independent of time and place and is designed for both real and simulated settings. The validity of the scale was tested using a virtual reality shoulder arthroscopy simulator. METHODS: The study consisted of two parts. In the first part, an Imperial Global Arthroscopy Rating Scale for assessing technical performance was developed using a Delphi method. Application of this scale required installing a dual-camera system to synchronously record the simulator screen and body movements of trainees to allow an assessment that is independent of time and place. The scale includes aspects such as efficient portal positioning, angles of instrument insertion, proficiency in handling the arthroscope and adequately manipulating the camera, and triangulation skills. In the second part of the study, a validation study was conducted. Two experienced arthroscopic surgeons, blinded to the identities and experience of the participants, each assessed forty-nine subjects performing three different tests using the Imperial Global Arthroscopy Rating Scale. Results were analyzed using two-way analysis of variance with measures of absolute agreement. The intraclass correlation coefficient was calculated for each test to assess inter-rater reliability. RESULTS: The scale demonstrated high internal consistency (Cronbach alpha, 0.918). The intraclass correlation coefficient demonstrated high agreement between the assessors: 0.91 (p < 0.001). Construct validity was evaluated using Kruskal-Wallis one-way analysis of variance (chi-square test, 29.826; p < 0.001), demonstrating that the Imperial Global Arthroscopy Rating Scale distinguishes significantly between subjects with different levels of experience utilizing a virtual reality simulator. CONCLUSIONS: The Imperial Global Arthroscopy Rating Scale has a high internal consistency and excellent inter-rater reliability and offers an approach for assessing technical performance in basic arthroscopy on a virtual reality simulator. CLINICAL RELEVANCE: The Imperial Global Arthroscopy Rating Scale provides detailed information on surgical skills. Although it requires further validation in the operating room, this scale, which is independent of time and place, offers a robust and reliable method for assessing arthroscopic technical skills.


Asunto(s)
Artroscopía/educación , Competencia Clínica , Evaluación Educacional/métodos , Articulación del Hombro/cirugía , Técnica Delphi , Humanos , Desempeño Psicomotor , Reproducibilidad de los Resultados , Grabación en Video
10.
Proc Inst Mech Eng H ; 226(6): 461-8, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22783762

RESUMEN

Analysis of the function of glenohumeral ligaments (GHLs) during physical joint manipulations is hindered by an inability to adequately image these tissues during the movements. This restricts functional biomechanics studies only to the manoeuvres that may be replicated cadaverically. There is, however, a clinical imperative to be able to investigate complex manoeuvres that exacerbate symptoms but cannot be easily conducted physically in the laboratory. The aim of this study was to develop and validate an algorithm for a computer simulation model that allows the quantification of glenohumeral ligament lengths during function. Datasets of the humerus and scapula pair were segmented to provide individual surface meshes of the bones and insertion points of each glenohumeral ligament on both bones. An algorithm was developed in which the glenohumeral ligament attachment-to-attachment length was divided into two straight lines, plus an arc overlaying the spherical wrapping portions. The model was validated by simulating two classical cadaveric studies from the literature and comparing results. Predictions from the model were qualitatively similar to the results of the two cadaveric studies by a factor of 91.7% and 81.8%, respectively. Algorithm application will allow investigation of functional loading of the glenohumeral ligaments during simulated complex motions. This could then be used to provide diagnostic understanding and thus, inform surgical reconstruction.


Asunto(s)
Algoritmos , Simulación por Computador , Ligamentos Articulares/fisiología , Modelos Anatómicos , Articulación del Hombro/fisiología , Fenómenos Biomecánicos , Cadáver , Humanos , Húmero/fisiología , Escápula/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA