Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Knee Surg ; 37(9): 664-673, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38442904

RESUMEN

The internet has introduced many resources frequently accessed by patients prior to orthopaedic visits. Recently, Chat Generative Pre-Trained Transformer, an artificial intelligence-based chat application, has become publicly and freely available. The interface uses deep learning technology to mimic human interaction and provide convincing answers to questions posed by users. With its rapidly expanding usership, it is reasonable to assume that patients will soon use this technology for preoperative education. Therefore, we sought to determine the accuracy of answers to frequently asked questions (FAQs) pertaining to total knee arthroplasty (TKA).Ten FAQs were posed to the chatbot during a single online interaction with no follow-up questions or repetition. All 10 FAQs were analyzed for accuracy using an evidence-based approach. Answers were then rated as "excellent response not requiring clarification," "satisfactory requiring minimal clarification," satisfactory requiring moderate clarification," or "unsatisfactory requiring substantial clarification."Of the 10 answers given by the chatbot, none received an "unsatisfactory" rating with the majority either requiring minimal (5) or moderate (4) clarification. While many answers required nuanced clarification, overall, answers tended to be unbiased and evidence-based, even when presented with controversial subjects.The chatbot does an excellent job of providing basic, evidence-based answers to patient FAQs prior to TKA. These data were presented in a manner that will be easily comprehendible by most patients and may serve as a useful clinical adjunct in the future.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Humanos , Educación del Paciente como Asunto , Internet , Encuestas y Cuestionarios
2.
J Bone Joint Surg Am ; 105(19): 1519-1526, 2023 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-37459402

RESUMEN

BACKGROUND: The contemporary patient has access to numerous resources on common orthopaedic procedures before ever presenting for a clinical evaluation. Recently, artificial intelligence (AI)-driven chatbots have become mainstream, allowing patients to engage with interfaces that supply convincing, human-like responses to prompts. ChatGPT (OpenAI), a recently developed AI-based chat technology, is one such application that has garnered rapid growth in popularity. Given the likelihood that patients may soon call on this technology for preoperative education, we sought to determine whether ChatGPT could appropriately answer frequently asked questions regarding total hip arthroplasty (THA). METHODS: Ten frequently asked questions regarding total hip arthroplasty were posed to the chatbot during a conversation thread, with no follow-up questions or repetition. Each response was analyzed for accuracy with use of an evidence-based approach. Responses were rated as "excellent response not requiring clarification," "satisfactory requiring minimal clarification," "satisfactory requiring moderate clarification," or "unsatisfactory requiring substantial clarification." RESULTS: Of the responses given by the chatbot, only 1 received an "unsatisfactory" rating; 2 did not require any correction, and the majority required either minimal (4 of 10) or moderate (3 of 10) clarification. Although several responses required nuanced clarification, the chatbot's responses were generally unbiased and evidence-based, even for controversial topics. CONCLUSIONS: The chatbot effectively provided evidence-based responses to questions commonly asked by patients prior to THA. The chatbot presented information in a way that most patients would be able to understand. This resource may serve as a valuable clinical tool for patient education and understanding prior to orthopaedic consultation in the future.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procedimientos Ortopédicos , Ortopedia , Humanos , Inteligencia Artificial , Comunicación
3.
Arthroplast Today ; 19: 101076, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36624747

RESUMEN

Background: Dexamethasone has the potential to cause a transient increase in blood glucose levels. Recent evidence has suggested the potential for a linearly increased risk of periprosthetic joint infection beginning at blood glucose levels of ≥115 mg/dL and an optimal cutoff of 137 mg/dL. We designed the following study to determine (1) what percentage of our patients had postoperative day 1 (POD1) glucose levels above 137 mg/dL and (2) if the administration of dexamethasone further increased this risk. Methods: All primary total knee arthroplasties performed from 1998 to 2021 at our institution were identified and retrospectively reviewed. Patient demographics, dexamethasone administration, and perioperative glucose levels were recorded. Outcomes included POD1 glucose levels, infection rate, and all-cause reoperations and revisions. Results: The average POD1 glucose level for the entire cohort (n = 5353) was 138.7 mg/dL. The percentage of patients with a glucose level of 137 mg/dL or higher was significantly greater in patients that received dexamethasone (55.2% vs 37.7%; P < .0001). Significantly higher glucose levels were seen with dexamethasone administration in both diabetic (187.7 vs 173.4 mg/dL; P < .0001) and nondiabetic patients (137.7 vs 128.0 mg/dL; P < .0001). Dexamethasone use was associated with a nonstatistically significant increase in infection rates (1.7% vs 1.0%; P = .177). Conclusions: Administration of dexamethasone is associated with a statistically significant increase in POD1 glucose levels, regardless of diabetic status. Dexamethasone use should continue to be closely monitored given the potential risks of elevated postoperative glucose levels and the potential for periprosthetic infection.

4.
Knee ; 40: 305-312, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36592499

RESUMEN

BACKGROUND: Aseptic tibial loosening following primary total knee replacement is one of the leading causes of long-term failure. Cement mantle thickness has been implicated as a source of aseptic tibial loosening. Therefore, the following study was designed to determine (1) what is the cement mantle thickness in patients that develop aseptic tibial loosening, and (2) is there a difference in cement mantle thickness based on the interface of failure? METHOD: This retrospective cohort included 216 patients revised for aseptic tibial loosening. Patient demographics, operative data, and clinical outcomes were recorded. A preoperative radiographic assessment was performed to determine the interface of failure and the thickness of the cement mantle using the Knee Society Radiographic Evaluation System zones. RESULTS: The average patient age was 65 years and body mass index was 33.7 kg/m2. 203 patients demonstrated radiographic failure at the implant-cement interface and 13 patients demonstrated failure at the cement-bone interface. The average cement mantle thickness of each radiographic zone for the entire cohort on the AP and lateral views was 4.4 and 4.5 mm, respectively. The average cement mantle thickness of patients that developed failure at the implant-cement interface was significantly greater than patients that failed at the cement-bone interface in each radiographic zone (p < 0.001). CONCLUSIONS: Patients that develop implant loosening at the cement-bone interface were noted to have a significantly decreased cement mantle compared to patients that failed at the implant-cement interface. Methods for decreasing tibial implant loosening should likely focus on improving the fixation at the implant-cement interface.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios Retrospectivos , Falla de Prótesis , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Tibia/diagnóstico por imagen , Tibia/cirugía , Cementos para Huesos
5.
J Arthroplasty ; 34(1): 27-35, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30268443

RESUMEN

BACKGROUND: Following tissue injury, the acute phase response (APR) functions to survive and then repair injured tissue. An exuberant APR, which can be evoked by total knee arthroplasty (TKA), results in a hyper-inflammatory state, leading to pain, nausea, venous thromboembolism, or potentially life-threatening complications. Here, we observed the effects of peri-operative dexamethasone on the APR following TKA by trending C-reactive protein (CRP, mg/L) and fibrinogen (mg/dL). We hypothesize that the anti-inflammatory effects of dexamethasone can attenuate the APR after TKA and will be associated with decreased post-operative pain and nausea. METHODS: A retrospective case-control study was performed on 188 unilateral TKA procedures. The patients were divided into a group receiving dexamethasone (10 mg intra-operatively and on post-operative day [POD] 1) and a group receiving no corticosteroids. Post-operative CRP, fibrinogen, morphine equivalents, and anti-emetic doses were recorded. RESULTS: Compared to the non-steroid group, patients receiving dexamethasone yielded a significantly decreased CRP on POD0 (5.5 vs 8.3), POD1 (11.8 vs 22.0), and POD2 (85.5 vs 148.9). A significant decrease in fibrinogen in patients receiving dexamethasone was seen on POD2 (460.0 vs 530.2). There was an increase in fibrinogen within the dexamethasone cohort at the 2-week visit (535.4 vs 488.9). Post-operative morphine equivalents administered were significantly decreased in patients receiving dexamethasone, but no difference in anti-emetic use was appreciated. CONCLUSION: These data support the hypothesis that the APR following TKA can be attenuated pharmacologically by corticosteroids. Further studies are needed to determine whether the attenuation of the APR with the use of corticosteroids prevents complications following TKA.


Asunto(s)
Reacción de Fase Aguda , Corticoesteroides/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Periodo Perioperatorio , Adulto , Anciano , Antiinflamatorios/uso terapéutico , Antieméticos/uso terapéutico , Proteína C-Reactiva/análisis , Estudios de Casos y Controles , Dexametasona , Femenino , Fibrinógeno/análisis , Humanos , Masculino , Persona de Mediana Edad , Morfina/uso terapéutico , Náusea/prevención & control , Dolor Postoperatorio , Periodo Posoperatorio , Estudios Retrospectivos
6.
J Arthroplasty ; 32(1): 309-314, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27554779

RESUMEN

BACKGROUND: During surgery, trauma to musculoskeletal tissue induces a systemic reaction known as the acute phase response (APR). When excessive or prolonged, the APR has been implicated as an underlying cause of surgical complications. The purpose of this study was to determine the typical APR following total joint arthroplasty in a healthy population defined by the Charlson Comorbidity Index (CCI). METHODS: This retrospective study identified 180 healthy patients (CCI < 2) who underwent total joint arthroplasty by a single surgeon for primary osteoarthritis from 2013 to 2015. Serial measurements of C-reactive protein (CRP) and fibrinogen were obtained preoperative, perioperative, and at 2 and 6 weeks postoperative. RESULTS: Postoperative CRP peaked during the inpatient period and returned to baseline by 2 weeks. Fibrinogen peaked after CRP and returned to baseline by 6 weeks. Elevated preoperative CRP correlated with a more robust postoperative APR for both total hip arthroplasty and total knee arthroplasty, suggesting that a patient's preoperative inflammatory state correlates with the magnitude of the postoperative APR. CONCLUSION: Measurement of preoperative acute phase reactants may provide an objective means to predict a patient's risk of postoperative dysregulation of the APR and complications.


Asunto(s)
Reacción de Fase Aguda/diagnóstico , Reacción de Fase Aguda/fisiopatología , Artroplastia de Reemplazo de Rodilla/efectos adversos , Osteoartritis de la Cadera/cirugía , Reacción de Fase Aguda/etiología , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Proteína C-Reactiva/análisis , Femenino , Fibrinógeno/análisis , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/fisiopatología , Periodo Posoperatorio , Estudios Retrospectivos
7.
J Arthroplasty ; 31(10): 2269-72, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27062350

RESUMEN

BACKGROUND: Serum d-dimer is a common screening test for symptomatic deep venous thrombosis (DVT) after total joint arthroplasty. This study characterized the longitudinal resolution of d-dimer measurements after total hip and knee arthroplasty (THA/TKA) over a 6-week period. The authors hypothesized that serum d-dimer would not return to baseline or be below the institutional threshold for a positive test at 6 weeks after uncomplicated total joint arthroplasty, suggesting that quantitative d-dimer has limited clinical utility for postoperative DVT screening. METHODS: An institutional review board-approved retrospective cohort study was conducted with consecutive patients between January 2013 and June 2015. A total of 177 adult patients aged 40-88 years who underwent a primary hip or knee arthroplasty with a Charlson Comorbidity Index <3 were included in the study. Serum d-dimer was measured at preoperative, perioperative, and postoperative 2- and 6-week time points. RESULTS: d-dimer measurements peaked 2 weeks postoperatively for both TKA and THA. At the 6-week time point, the peak serum d-dimer measurement resolved by 54.3% and 76.6% for TKA and THA, respectively. At 6 weeks after operation, 92% of THA patient and 100% of TKA patients had serum d-dimer measurements higher than the institutional threshold (0.40 µg/mL) for a "positive" quantitative test. No symptomatic DVTs were reported for the THA and TKA cohorts during the study period. CONCLUSION: The results suggest that serum d-dimer is an ineffective screening test for the diagnosis of symptomatic DVT in the acute postoperative period. The authors propose that extravascular fibrinolysis, a process essential for wound healing, has a crucial role in the prolonged elevation of serum d-dimer in the postoperative period.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Productos de Degradación de Fibrina-Fibrinógeno/metabolismo , Complicaciones Posoperatorias/sangre , Trombosis de la Vena/sangre , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Periodo Posoperatorio , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Trombosis de la Vena/etiología
8.
Eur Spine J ; 25(8): 2408-15, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27106489

RESUMEN

PURPOSE: To investigate the relationship between lumbar facet fluid and dynamic instability in degenerative spondylolisthesis (DS), as well as the relationship between facet fluid and patient-reported outcomes following a posterior lumbar fusion. METHODS: We analyzed consecutive patients with degenerative spondylolisthesis undergoing single level posterior lumbar fusion from December 2010 to January 2013 at a single academic institution. We investigated the relationship between fluid in the facet joint as measured on axial MRI and the presence of dynamic instability. We investigated the impact of facet fluid, Modic changes, and dynamic instability on patient-reported outcomes. RESULTS: There was a significant association between the amount of facet joint fluid and the presence of dynamic instability (p = 0.03); as facet fluid increases, the probability of dynamic instability also increases. For every 1 mm of facet fluid, there was a 41.6 % increase (95 % CI 1.8-97) in the odds of dynamic instability. A facet fluid amount less than 0.5 mm gave a 90 % probability that there was no dynamic instability. The presence of facet fluid and dynamic instability were associated with achieving minimal clinical important difference (MCID) in low back pain following lumbar fusion (p = 0.04 and 0.05, respectively). CONCLUSION: Facet joint fluid is associated with the presence of dynamic instability in DS. The presence of facet fluid and dynamic instability may predict increased likelihood of achieving MCID for improvement in back pain following posterior lumbar fusion.


Asunto(s)
Vértebras Lumbares/cirugía , Sistema de Registros , Fusión Vertebral , Espondilolistesis/cirugía , Articulación Cigapofisaria/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Dolor de la Región Lumbar/etiología , Vértebras Lumbares/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Diferencia Mínima Clínicamente Importante , Pronóstico , Estudios Retrospectivos , Espondilolistesis/complicaciones , Espondilolistesis/diagnóstico por imagen
9.
J Arthroplasty ; 30(3): 507-11, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25542833

RESUMEN

Hyaluronic acid (HA) injections are used to treat osteoarthritis of the hip but their efficacy has not been clearly established. The purpose of this meta-analysis was to determine the effect of HA injections on hip pain. There were twenty-three studies that met our criteria and the mean decrease in visual analog scores (VAS) was -1.97 (95% CL, 2.83 to -1.12, P<0.0001). However, the clinical relevance of this change is difficult to determine since the decrease in VAS was only -0.27 in the six randomized trials in the study and the duration of follow-up in most studies was less than six months. Multicenter randomized trials are needed to determine the true efficacy of HA injections in decreasing pain associated with hip osteoarthritis.


Asunto(s)
Articulación de la Cadera , Ácido Hialurónico/administración & dosificación , Osteoartritis de la Cadera/tratamiento farmacológico , Viscosuplementos/administración & dosificación , Humanos , Inyecciones Intraarticulares , Resultado del Tratamiento
10.
Clin Orthop Relat Res ; 470(2): 525-34, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21879405

RESUMEN

BACKGROUND: Although surgeons use many procedures to preserve the femoral head in patients with hip osteonecrosis, there is no consensus regarding the best procedure. QUESTIONS/PURPOSES: We raised the following questions: (1) Is one surgical treatment preferred based on published data? (2) What are the rates of radiographic progression or conversion to THA after treatment of pre- and postcollapse hips? (3) Does lesion size in the femoral head influence progression? And (4) does the extent of involvement of the weightbearing surface of the femoral head influence outcome? METHODS: We searched MEDLINE and Scopus for articles published between 1998 and 2010. We included only articles assessing an operative intervention for hip osteonecrosis and having a level of evidence of I to IV. We included 54 of the 488 reviewed manuscripts. RESULTS: No procedure was superior to others. In pre- and postcollapse hips, 264 of 864 hips (31%) and 419 of 850 hips (49%), respectively, exhibited radiographic disease progression. There were lower failure rates when the lesion involved less than 15% of the femoral head or had a necrotic angle of less than 200° (14%-25%) and when the osteonecrotic lesion involved only the medial 1/3 of the weightbearing surface (4.6%). CONCLUSIONS: The best treatment of precollapse lesions is difficult to determine due to the limitations of the available literature. However, the data suggest operative intervention prevents collapse of small lesions of the femoral head or when there is a limited amount of the weightbearing surface involved. Patients with head collapse have a high progression rate after a femoral head-saving procedure.


Asunto(s)
Necrosis de la Cabeza Femoral/cirugía , Articulación de la Cadera/cirugía , Procedimientos Ortopédicos , Artroplastia de Reemplazo de Cadera , Progresión de la Enfermedad , Medicina Basada en la Evidencia , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Necrosis de la Cabeza Femoral/fisiopatología , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Humanos , Radiografía , Reoperación , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento , Soporte de Peso
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...