Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cell Rep ; 43(2): 113671, 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38280195

RESUMEN

Outside of the laboratory, animals behave in spaces where they can transition between open areas and coverage as they interact with others. Replicating these conditions in the laboratory can be difficult to control and record. This has led to a dominance of relatively simple, static behavioral paradigms that reduce the ethological relevance of behaviors and may alter the engagement of cognitive processes such as planning and decision-making. Therefore, we developed a method for controllable, repeatable interactions with others in a reconfigurable space. Mice navigate a large honeycomb lattice of adjustable obstacles as they interact with an autonomous robot coupled to their actions. We illustrate the system using the robot as a pseudo-predator, delivering airpuffs to the mice. The combination of obstacles and a mobile threat elicits a diverse set of behaviors, such as increased path diversity, peeking, and baiting, providing a method to explore ethologically relevant behaviors in the laboratory.


Asunto(s)
Robótica , Navegación Espacial , Ratones , Animales , Robótica/métodos , Roedores
2.
Aging Clin Exp Res ; 30(10): 1233-1239, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29464504

RESUMEN

OBJECTIVE: A previous multidisciplinary pilot study based on computer simulations for the geriatric population showed that a dose of 0.5 mg/kg/h of propofol could sedate patients older than 65 for pacemaker implantation. The present study validates that the pacemaker implantation can be done in the elderly using 0.5-1 mg/kg/h of propofol with hemodynamic stability. METHODS: 66 patients from 65 to 88 years old scheduled for pacemaker implantation were randomly assigned one of three doses of propofol. The first group received 2 mg/kg/h of propofol (P2) that is within normal range of the sedation dose. The second group received 1 mg/kg/h (P1) dose and the third group received the dose of 0.5 mg/kg/h (P0.5) according to the simulation-predicted dose for geriatric populations. RESULTS: All patients kept MAP between 76 and 85 mmHg, with no hypotension episodes in any of the groups; therefore, they were all hemodynamically stable during the procedure. BIS was between 80 and 65 during the pacemaker implantation for the three groups, BIS of group P2 was significantly lower than the other groups. BIS in groups P1 and P0.5 was within the appropriated range for moderate sedation. Brice was positive for auditory recalls only when there was arousing noise in the operating room. CONCLUSIONS: Moderate sedation, adequate for pacemaker implantation, can be achieved infusing 0.5-1 mg/kg/h of propofol in elderly patients when the patient has proper analgesia management at the device implantation site. The second important condition is to avoid unnecessary and alerting auditory and mechanical stimuli in the operating room, so that the patient will remain calm.


Asunto(s)
Sedación Consciente , Hipnóticos y Sedantes/administración & dosificación , Marcapaso Artificial , Propofol/administración & dosificación , Implantación de Prótesis , Factores de Edad , Anciano , Anciano de 80 o más Años , Relación Dosis-Respuesta a Droga , Femenino , Humanos , Hipnóticos y Sedantes/efectos adversos , Masculino , Propofol/efectos adversos
3.
Comput Methods Programs Biomed ; 132: 21-7, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27282224

RESUMEN

The geriatric population shows significant physiological changes due to aging and the multiple co-morbidities that they often present. Conventionally the propofol sedation dose for patients older than 65 years is 80% of the adult dose. We performed an in silico trial for elderly population and the results showed that the necessary simulated dose of propofol was lower than the conventional dose; therefore, a clinical trial was implemented to test three different propofol doses, two of them lower than the conventional dose, during a pacemaker implantation. The clinical trial showed that there was no clinical difference between the effects of the doses. A BIS monitor was used to measure the level of sedation, which proved to be adequate and well maintained by all patients. All the patients maintained an acceptable level of sedation, measured by a BIS monitor. Since propofol has some dose-dependent secondary effects, the use of lower doses, especially the ones designed for this age group, helps to avoid them.


Asunto(s)
Propofol/administración & dosificación , Anciano , Simulación por Computador , Relación Dosis-Respuesta a Droga , Humanos , Hipnóticos y Sedantes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA