Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 186
1.
CJC Open ; 6(3): 560-568, 2024 Mar.
Article En | MEDLINE | ID: mdl-38559338

Background: Endocardial catheter ablation for ventricular tachycardia (VT) may fail because of the inability to deliver transmural lesions. Ultra-low-temperature cryoablation (ULTC) uses near-critical nitrogen and can generate temperatures as low as -196 °C. We report a series of 18 patients who underwent ULTC at the McGill University Health Centre (MUHC), representing the largest single-centre experience to date. Methods: Eighteen patients with monomorphic drug-refractory VT underwent VT ablation with ULTC at our institution as part of the first-in-human CryoCure-VT trial (NCT04893317). After voltage map, the mapping catheter was replaced with the ULTC catheter, and lesions were applied over a fixed duration of time (60-180 seconds), followed by a 60-second thaw and another application at the original duration (freeze-thaw-freeze). Duration of ablation time was selected depending on the wall thickness of the left ventricle monitored with intracardiac echo to achieve tissue depths of 4.5 to 7.5 mm. Results: Baseline left ventricular ejection fraction was 32%, mean age 71 years, 94% were male. A total of 32 sustained VTs were induced in 16 of 18 patients. A total of 177 cryoablation lesions were delivered (9.8 lesions per patient). Of the 16 patients with inducible VT, 15 (94%) were rendered noninducible postablation, and 1 was inducible only for a nonclinical VT. Complications included 1 pericardial effusion that required drainage. From 18 patients, 16 (89%) were discharged within the first 24 hours postablation. Conclusions: ULTC is feasible and permits acute control of monomorphic VT during VT ablation procedures in drug-refractory patients.


Contexte: L'ablation endocardique par cathéter pour traiter la tachycardie ventriculaire (TV) peut être un échec, en raison de l'incapacité à créer des lésions transmurales. La cryoablation à ultra-basse température (ULTC, pour ultra-low-temperature cryoablation) réalisée au moyen d'azote près de son point critique liquide-vapeur peut produire des températures aussi basses que ­196 °C. Nous faisons état d'une série de 18 patients ayant subi une ULTC au Centre universitaire de santé McGill (CUSM), ce qui représente la plus importante expérience menée dans un seul établissement jusqu'à ce jour. Méthodologie: Au total, 18 patients atteints de TV monomorphe pharmacorésistante ont subi une ablation de la TV par ULTC à notre établissement, dans le cadre du premier essai mené chez l'humain sur la guérison par cryothérapie de la TV (NCT04893317). Après l'obtention de la carte électrophysiologique, le cathéter de cartographie a été remplacé par le cathéter d'ULTC, qui a permis de créer des lésions par l'application de froid pendant une durée fixe (de 60 à 180 secondes), suivie d'une période de dégel de 60 secondes, puis d'une autre application de froid pendant la même durée que la première application (cycle gel-dégel-gel). La durée de l'ablation a été déterminée en fonction de l'épaisseur de la paroi du ventricule gauche surveillée par échocardiographie endocavitaire afin d'obtenir des profondeurs tissulaires de 4,5 à 7,5 mm. Résultats: La fraction d'éjection du ventricule gauche initiale était de 32 %, l'âge moyen des sujets était de 71 ans et 94 % d'entre eux étaient de sexe masculin. Au total, 32 TV soutenues ont été induites chez 16 patients sur 18. Dans l'ensemble, 177 lésions de cryoablation ont été créées (soit 9,8 lésions par patient). Après l'ablation, nous avons été incapables d'induire une TV chez 15 (94 %) des 16 patients chez qui nous en avions induit avant l'intervention et, chez le patient restant, nous avons pu induire une TV non clinique seulement. Les complications comprenaient un cas d'épanchement péricardique ayant nécessité un drainage. Au total, 16 (89 %) des 18 patients ont reçu leur congé de l'hôpital dans les 24 heures suivant l'ablation. Conclusions: L'ULTC est réalisable et permet une maîtrise rigoureuse de la TV monomorphe lors des interventions d'ablation de la TV chez les patients dont la TV est pharmacorésistante.

2.
Europace ; 26(4)2024 Mar 30.
Article En | MEDLINE | ID: mdl-38582974

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Cardiomyopathies , Catheter Ablation , Cryosurgery , Tachycardia, Ventricular , Aged , Humans , Middle Aged , Cardiomyopathies/complications , Cardiomyopathies/diagnosis , Cardiomyopathies/surgery , Catheter Ablation/adverse effects , Cicatrix/complications , Cryosurgery/adverse effects , Prospective Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery , Temperature , Treatment Outcome
4.
Medicina (Kaunas) ; 60(4)2024 Mar 26.
Article En | MEDLINE | ID: mdl-38674182

Atrial fibrillation (AF) is an important independent risk factor for stroke. Current guidelines handle AF as a binary entity with risk driven by the presence of clinical risk factors, which guides the decision to treat with an oral anticoagulant. Recent studies in the literature suggest a dose-response relationship between AF burden and stroke risk, in both clinical AF and subclinical atrial fibrillation (SCAF), which differs from current guidance to disregard burden and utilize clinical risk scores alone. Within clinical classification and at the same risk levels in various scores, the risk of stroke increases with AF burden. This opens the possibility of incorporating burden into risk profiles, which has already shown promise. Long-term rhythm monitoring is needed to elucidate SCAF in patients with stroke. Recent data from randomized trials are controversial regarding whether there is an independent risk from AF episodes with a duration of less than 24 h, including the duration of SCAF greater than six minutes but less than 24 h.


Atrial Fibrillation , Stroke , Atrial Fibrillation/complications , Humans , Stroke/prevention & control , Stroke/etiology , Risk Factors , Anticoagulants/therapeutic use , Risk Assessment/methods
6.
Int J Cardiol Heart Vasc ; 51: 101360, 2024 Apr.
Article En | MEDLINE | ID: mdl-38379634

Background: Cardioneuroablation (CNA) is an ablation technique that targets epicardial ganglionic plexi to reduce syncope burden and avoid pacemaker implantation in patients with cardioinhibitory vasovagal syncope (VVS). This study aims to demonstrate feasibility and safety of CNA in high-risk refractory VVS patients using continuous monitoring with an implantable loop recorder (ILR). Methods: Data was collected prospectively for patients undergoing CNA. Patients were required to have recurrent syncope with documented asystole, refractory to conservative measures. Ganglionic plexi (GPs) were identified by fragmented signals and high frequency stimulation (HFS). Ablation was performed until loss of positive response to HFS, Wenckebach cycle shortening was achieved, or an increase in sinus rate of > 20 bpm. Follow-up was performed through remote and clinic follow-up of their ILRs. Results: Between December 2020 and July 2023 six patients (mean age 29 ± 3, 67 % female)underwent CNA. The baseline heart rate and Wenckebach cycle length was 63.2 ± 15 bpm and 582 ms before and 91 ± 5 bpm and 358 ms after ablation respectively. During a median follow-up of 13.4 months, 3/5 patients had no further syncopal episodes, 1 had a recurrence, underwent repeat CNA with no further episodes at 1 year, and 1 had 5 syncopal events, which was a dramatic reduction from nearly daily episodes pre-CNA. There were no procedure related complications. Conclusions: A dramatic reduction in documented pauses and syncope burden was noted post CNA. Appropriate patient selection with rigorous objective follow-up in an experienced center is necessary. Larger studies are required to confirm these findings.

7.
J Cardiovasc Electrophysiol ; 35(1): 136-145, 2024 Jan.
Article En | MEDLINE | ID: mdl-37990448

INTRODUCTION: Pulmonary vein isolations (PVI) are being performed using a high-power, short-duration (HPSD) strategy. The purpose of this study was to compare the clinical efficacy and safety outcomes of an HPSD versus low-power, long-duration (LPLD) approach to PVI in patients with paroxysmal atrial fibrillation (AF). METHODS: Patients were grouped according to a HPSD (≥40 W) or LPLD (≤35 W) strategy. The primary endpoint was the 1-year recurrence of any atrial arrhythmia lasting ≥30 s, detected using three 14-day ambulatory continuous ECG monitoring. Procedural and safety endpoints were also evaluated. The primary analysis were regression models incorporating propensity scores yielding adjusted relative risk (RRa ) and mean difference (MDa ) estimates. RESULTS: Of the 398 patients included in the AWARE Trial, 173 (43%) underwent HPSD and 225 (57%) LPLD ablation. The distribution of power was 50 W in 75%, 45 W in 20%, and 40 W in 5% in the HPSD group, and 35 W with 25 W on the posterior wall in the LPLD group. The primary outcome was not statistically significant at 30.1% versus 22.2% in HPSD and LPLD groups with RRa 0.77 (95% confidence interval [CI]) 0.55-1.10; p = .165). The secondary outcome of repeat catheter ablation was not statistically significant at 6.9% and 9.8% (RRa 1.59 [95% CI 0.77-3.30]; p = .208) respectively, nor was the incidence of any ECG documented AF during the blanking period: 1.7% versus 8.0% (RRa 3.95 [95% CI 1.00-15.61; p = .049) in the HPSD versus LPLD group respectively. The total procedure time was significantly shorter in the HPSD group (MDa 97.5 min [95% CI 84.8-110.4)]; p < .0001) with no difference in adjudicated serious adverse events. CONCLUSIONS: An HPSD strategy was associated with significantly shorter procedural times with similar efficacy in terms of clinical arrhythmia recurrence. Importantly, there was no signal for increased harm with a HPSD strategy.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Treatment Outcome , Recurrence
8.
Lancet ; 402(10408): 1147-1157, 2023 09 30.
Article En | MEDLINE | ID: mdl-37634520

BACKGROUND: Continuous automatic optimisation of cardiac resynchronisation therapy (CRT), stimulating only the left ventricle to fuse with intrinsic right bundle conduction (synchronised left ventricular stimulation), might offer better outcomes than conventional CRT in patients with heart failure, left bundle branch block, and normal atrioventricular conduction. This study aimed to compare clinical outcomes of adaptive CRT versus conventional CRT in patients with heart failure with intact atrioventricular conduction and left bundle branch block. METHODS: This global, prospective, randomised controlled trial was done in 227 hospitals in 27 countries across Asia, Australia, Europe, and North America. Eligible patients were aged 18 years or older with class 2-4 heart failure, an ejection fraction of 35% or less, left bundle branch block with QRS duration of 140 ms or more (male patients) or 130 ms or more (female patients), and a baseline PR interval 200 ms or less. Patients were randomly assigned (1:1) via block permutation to adaptive CRT (an algorithm providing synchronised left ventricular stimulation) or conventional biventricular CRT using a device programmer. All patients received device programming but were masked until procedures were completed. Site staff were not masked to group assignment. The primary outcome was a composite of all-cause death or intervention for heart failure decompensation and was assessed in the intention-to-treat population. Safety events were collected and reported in the intention-to-treat population. This study is registered with ClinicalTrials.gov, NCT02205359, and is closed to accrual. FINDINGS: Between Aug 5, 2014, and Jan 31, 2019, of 3797 patients enrolled, 3617 (95·3%) were randomly assigned (1810 to adaptive CRT and 1807 to conventional CRT). The futility boundary was crossed at the third interim analysis on June 23, 2022, when the decision was made to stop the trial early. 1568 (43·4%) of 3617 patients were female and 2049 (56·6%) were male. Median follow-up was 59·0 months (IQR 45-72). A primary outcome event occurred in 430 of 1810 patients (Kaplan-Meier occurrence rate 23·5% [95% CI 21·3-25·5] at 60 months) in the adaptive CRT group and in 470 of 1807 patients (25·7% [23·5-27·8] at 60 months) in the conventional CRT group (hazard ratio 0·89, 95% CI 0·78-1·01; p=0·077). System-related adverse events were reported in 452 (25·0%) of 1810 patients in the adaptive CRT group and 440 (24·3%) of 1807 patients in the conventional CRT group. INTERPRETATION: Compared with conventional CRT, adaptive CRT did not significantly reduce the incidence of all-cause death or intervention for heart failure decompensation in the included population of patients with heart failure, left bundle branch block, and intact AV conduction. Death and heart failure decompensation rates were low with both CRT therapies, suggesting a greater response to CRT occurred in this population than in patients in previous trials. FUNDING: Medtronic.


Cardiac Resynchronization Therapy , Heart Failure , Humans , Male , Female , Bundle-Branch Block/etiology , Bundle-Branch Block/therapy , Prospective Studies , Treatment Outcome , Cardiac Resynchronization Therapy/adverse effects , Cardiac Resynchronization Therapy/methods , Stroke Volume , Electrocardiography
9.
JACC Clin Electrophysiol ; 9(6): 808-821, 2023 06.
Article En | MEDLINE | ID: mdl-37380314

BACKGROUND: Catheter ablation improves ventricular tachycardia (VT) event-free (time to event) survival in patients with antiarrhythmic drug (AAD)-refractory VT and previous myocardial infarction (MI). The effects of ablation on recurrent VT and implantable cardioverter-defibrillator (ICD) therapy (burden) have yet to be investigated. OBJECTIVES: This study sought to compare the VT and ICD therapy burden following treatment with either ablation or escalated AAD therapy among patients with VT and previous MI in the VANISH (Ventricular tachycardia AblatioN versus escalated antiarrhythmic drug therapy in ISchemic Heart disease) trial. METHODS: The VANISH trial randomized patients with previous MI and VT despite initial AAD therapy to either escalated AAD treatment or catheter ablation. VT burden was defined as the total number of VT events treated with ≥1 appropriate ICD therapy. Appropriate ICD therapy burden was defined as the total number of appropriate shocks or antitachycardia pacing therapies (ATPs) delivered. The Anderson-Gill recurrent event model was used to compare burden between the treatment arms. RESULTS: Of the 259 enrolled patients (median age, 69.8 years; 7.0% women), 132 patients were randomized to ablation and 129 patients were randomized to escalated AAD therapy. Over 23.4 months of follow-up, ablation-treated patients had a 40% lower shock-treated VT event burden and a 39% lower appropriate shock burden compared with patients who received escalated AAD therapy (P <0.05 for all). A reduction in VT burden, ATP-treated VT event burden, and appropriate ATP burden among ablation patients was only demonstrated in the stratum of patients with amiodarone-refractory VT (P <0.05 for all). CONCLUSIONS: Among patients with AAD-refractory VT and a previous MI, catheter ablation reduced shock-treated VT event burden and appropriate shock burden compared with escalated AAD therapy. There was also lower VT burden, ATP-treated VT event burden, and appropriate ATP burden among ablation-treated patients; however, the effect was limited to patients with amiodarone-refractory VT.


Amiodarone , Catheter Ablation , Defibrillators, Implantable , Myocardial Infarction , Tachycardia, Ventricular , Humans , Female , Aged , Male , Anti-Arrhythmia Agents/therapeutic use , Tachycardia, Ventricular/drug therapy , Tachycardia, Ventricular/surgery , Adenosine Triphosphate
10.
JAMA Cardiol ; 8(5): 484-491, 2023 05 01.
Article En | MEDLINE | ID: mdl-37017943

Importance: Cardiac implantable electronic device (CIED) infection is a potentially devastating complication with an estimated 12-month mortality of 15% to 30%. The association of the extent (localized or systemic) and timing of infection with all-cause mortality has not been established. Objective: To evaluate the association of the extent and timing of CIED infection with all-cause mortality. Design, Setting, and Participants: This prospective observational cohort study was conducted between December 1, 2012, and September 30, 2016, in 28 centers across Canada and the Netherlands. The study included 19 559 patients undergoing CIED procedures, 177 of whom developed an infection. Data were analyzed from April 5, 2021, to January 14, 2023. Exposures: Prospectively identified CIED infections. Main Outcomes and Measures: Time-dependent analysis of the timing (early [≤3 months] or delayed [3-12 months]) and extent (localized or systemic) of infection was performed to determine the risk of all-cause mortality associated with CIED infections. Results: Of 19 559 patients undergoing CIED procedures, 177 developed a CIED infection. The mean (SD) age was 68.7 (12.7) years, and 132 patients were male (74.6%). The cumulative incidence of infection was 0.6%, 0.7%, and 0.9% within 3, 6, and 12 months, respectively. Infection rates were highest in the first 3 months (0.21% per month), reducing significantly thereafter. Compared with patients who did not develop CIED infection, those with early localized infections were not at higher risk for all-cause mortality (no deaths at 30 days [0 of 74 patients]: adjusted hazard ratio [aHR], 0.64 [95% CI, 0.20-1.98]; P = .43). However, patients with early systemic and delayed localized infections had an approximately 3-fold increase in mortality (8.9% 30-day mortality [4 of 45 patients]: aHR, 2.88 [95% CI, 1.48-5.61]; P = .002; 8.8% 30-day mortality [3 of 34 patients]: aHR, 3.57 [95% CI, 1.33-9.57]; P = .01), increasing to a 9.3-fold risk of death for those with delayed systemic infections (21.7% 30-day mortality [5 of 23 patients]: aHR, 9.30 [95% CI, 3.82-22.65]; P < .001). Conclusions and Relevance: Findings suggest that CIED infections are most common within 3 months after the procedure. Early systemic infections and delayed localized infections are associated with increased mortality, with the highest risk for patients with delayed systemic infections. Early detection and treatment of CIED infections may be important in reducing mortality associated with this complication.


Defibrillators, Implantable , Heart Diseases , Humans , Male , Aged , Female , Defibrillators, Implantable/adverse effects , Prospective Studies , Heart Diseases/etiology , Canada , Netherlands
11.
JAMA Cardiol ; 8(5): 475-483, 2023 05 01.
Article En | MEDLINE | ID: mdl-36947030

Importance: Recurrent atrial fibrillation (AF) commonly occurs after catheter ablation and is associated with patient morbidity and health care costs. Objective: To evaluate the superiority of an augmented double wide-area circumferential ablation (WACA) compared with a standard single WACA in preventing recurrent atrial arrhythmias (AA) (atrial tachycardia, atrial flutter, or atrial fibrillation [AF]) in patients with paroxysmal AF. Design, Setting, and Participants: This was a pragmatic, multicenter, prospective, randomized, open, blinded end point superiority clinical trial conducted at 10 university-affiliated centers in Canada. The trial enrolled patients 18 years and older with symptomatic paroxysmal AF from March 2015 to May 2017. Analysis took place between January and April 2022. Analyses were intention to treat. Interventions: Patients were randomized (1:1) to receive radiofrequency catheter ablation for pulmonary vein isolation with either a standard single WACA or an augmented double WACA. Main Outcomes and Measures: The primary outcome was AA recurrence between 91 and 365 days postablation. Patients underwent 42 days of ambulatory electrocardiography monitoring after ablation. Secondary outcomes included need for repeated catheter ablation and procedural and safety variables. Results: Of 398 patients, 195 were randomized to the single WACA (control) arm (mean [SD] age, 60.6 [9.3] years; 65 [33.3%] female) and 203 to the double WACA (experimental) arm (mean [SD] age, 61.5 [9.3] years; 66 [32.5%] female). Overall, 52 patients (26.7%) in the single WACA arm and 50 patients (24.6%) in the double WACA arm had recurrent AA at 1 year (relative risk, 0.92; 95% CI, 0.66-1.29; P = .64). Twenty patients (10.3%) in the single WACA arm and 15 patients (7.4%) in the double WACA arm underwent repeated catheter ablation (relative risk, 0.72; 95% CI, 0.38-1.36). Adjudicated serious adverse events occurred in 13 patients (6.7%) in the single WACA arm and 14 patients (6.9%) in the double WACA arm. Conclusions and Relevance: In this randomized clinical trial of patients with paroxysmal AF, additional ablation by performing a double ablation lesion set did not result in improved freedom from recurrent AA compared with a standard single ablation set. Trial Registration: ClinicalTrials.gov Identifier: NCT02150902.


Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Pulmonary Veins , Humans , Female , Middle Aged , Male , Atrial Fibrillation/drug therapy , Prospective Studies , Pulmonary Veins/surgery , Electrocardiography, Ambulatory , Catheter Ablation/adverse effects
12.
Cureus ; 15(1): e33222, 2023 Jan.
Article En | MEDLINE | ID: mdl-36741597

The use of novel oral anticoagulants (NOAC) in patients with moderate to severe mitral stenosis (MS) and atrial fibrillation (AF) is not recommended. We aimed to evaluate the efficacy and safety of NOAC usage compared to vitamin K antagonist (VKA) in patients with moderate to severe MS and AF. We conducted a systematic review to identify articles that compared warfarin to NOAC in patients with moderate to severe MS and AF. Only four studies (two observational studies and two trials) met our search criteria and reported a total of 7529 patients with MS and AF with MS and AF, 4138 of them treated with NOAC. In both observational studies, the severity of MS was not determined, and there was heterogeneity in MS etiology. Nevertheless, both studies showed a positive signal toward the efficacy and safety of NOAC compared to VKA in this population. A randomized pilot trial (n=40) was done on patients with moderate to severe MS, and it showed further acceptable efficacy and safety for rivaroxaban use. However, a larger randomized controlled trial (n=4531) disclosed that VKA (warfarin) led to a significantly lower rate of a composite of cardiovascular events or mortality than rivaroxaban, without a higher rate of major bleeding but not fatal bleeding. Our systematic review provides exploratory information on NOAC safety and effectiveness in patients with MS; it also discourages using NOACs for patients with moderate to severe MS and supports the current treatment guidelines. However, more dedicated clinical trials evaluating the use of NOACs in moderate to severe MS are underway. They will categorically establish the safety profile and clinical effectiveness of NOAC in this high-risk population.

13.
N Engl J Med ; 388(2): 105-116, 2023 01 12.
Article En | MEDLINE | ID: mdl-36342178

BACKGROUND: Atrial fibrillation is a chronic, progressive disorder, and persistent forms of atrial fibrillation are associated with increased risks of thromboembolism and heart failure. Catheter ablation as initial therapy may modify the pathogenic mechanism of atrial fibrillation and alter progression to persistent atrial fibrillation. METHODS: We report the 3-year follow-up of patients with paroxysmal, untreated atrial fibrillation who were enrolled in a trial in which they had been randomly assigned to undergo initial rhythm-control therapy with cryoballoon ablation or to receive antiarrhythmic drug therapy. All the patients had implantable loop recorders placed at the time of trial entry, and evaluation was conducted by means of downloaded daily recordings and in-person visits every 6 months. Data regarding the first episode of persistent atrial fibrillation (lasting ≥7 days or lasting 48 hours to 7 days but requiring cardioversion for termination), recurrent atrial tachyarrhythmia (defined as atrial fibrillation, flutter, or tachycardia lasting ≥30 seconds), the burden of atrial fibrillation (percentage of time in atrial fibrillation), quality-of-life metrics, health care utilization, and safety were collected. RESULTS: A total of 303 patients were enrolled, with 154 patients assigned to undergo initial rhythm-control therapy with cryoballoon ablation and 149 assigned to receive antiarrhythmic drug therapy. Over 36 months of follow-up, 3 patients (1.9%) in the ablation group had an episode of persistent atrial fibrillation, as compared with 11 patients (7.4%) in the antiarrhythmic drug group (hazard ratio, 0.25; 95% confidence interval [CI], 0.09 to 0.70). Recurrent atrial tachyarrhythmia occurred in 87 patients in the ablation group (56.5%) and in 115 in the antiarrhythmic drug group (77.2%) (hazard ratio, 0.51; 95% CI, 0.38 to 0.67). The median percentage of time in atrial fibrillation was 0.00% (interquartile range, 0.00 to 0.12) in the ablation group and 0.24% (interquartile range, 0.01 to 0.94) in the antiarrhythmic drug group. At 3 years, 8 patients (5.2%) in the ablation group and 25 (16.8%) in the antiarrhythmic drug group had been hospitalized (relative risk, 0.31; 95% CI, 0.14 to 0.66). Serious adverse events occurred in 7 patients (4.5%) in the ablation group and in 15 (10.1%) in the antiarrhythmic drug group. CONCLUSIONS: Initial treatment of paroxysmal atrial fibrillation with catheter cryoballoon ablation was associated with a lower incidence of persistent atrial fibrillation or recurrent atrial tachyarrhythmia over 3 years of follow-up than initial use of antiarrhythmic drugs. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Anti-Arrhythmia Agents , Atrial Fibrillation , Catheter Ablation , Cryosurgery , Humans , Anti-Arrhythmia Agents/adverse effects , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/drug therapy , Atrial Fibrillation/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cryosurgery/adverse effects , Cryosurgery/methods , Recurrence , Tachycardia/etiology , Treatment Outcome , Disease Progression , Follow-Up Studies
14.
Am Heart J ; 254: 133-140, 2022 Dec.
Article En | MEDLINE | ID: mdl-36030965

BACKGROUND: Atrial low voltage area (LVA) catheter ablation has emerged as a promising strategy for ablation of persistent atrial fibrillation (AF). It is unclear if catheter ablation of atrial LVA increases treatment success rates in patients with persistent AF. OBJECTIVE: The primary aim of this trial is to assess the potential benefit of adjunctive catheter ablation of atrial LVA in addition to pulmonary vein isolation (PVI) in patients with persistent AF, when compared to PVI alone. The secondary aims are to evaluate safety outcomes, the quality of life and the healthcare resource utilization. METHODS/DESIGN: A multicenter, prospective, parallel-group, 2-arm, single-blinded randomized controlled trial is under way (NCT03347227). Patients who are candidates for catheter ablation for persistent AF will be randomly assigned (1:1) to either PVI alone or PVI + atrial LVA ablation. The primary outcome is 18-month documented event rate of atrial arrhythmia (AF, atrial tachycardia or atrial flutter) post catheter ablation. Secondary outcomes include procedure-related complications, freedom from atrial arrhythmia at 12 months, AF burden, need for emergency department visits/hospitalization, need for repeat ablation for atrial arrhythmia, quality of life at 12 and 18 months, ablation time, and procedure duration. DISCUSSION: Characterization of Arrhythmia Mechanism to Ablate Atrial Fibrillation (COAST-AF) is a multicenter randomized trial evaluating ablation strategies for catheter ablation. We hypothesize that catheter ablation of atrial LVA in addition to PVI will result in higher procedural success rates when compared to PVI alone in patients with persistent AF.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Prospective Studies , Quality of Life , Pulmonary Veins/surgery , Catheter Ablation/methods , Treatment Outcome , Recurrence
15.
CJC Open ; 4(7): 617-624, 2022 Jul.
Article En | MEDLINE | ID: mdl-35865020

Background: The Syncope: Pacing or Recording in the Later Years (SPRITELY) trial reported that a strategy of empiric permanent pacing in patients with syncope and bifascicular block reduces major adverse events more effectively than acting on the results of an implantable cardiac monitor (ICM). Our objective was to determine the cost-effectiveness of using the ICM, compared with a pacemaker (PM), in the management of older adults (age > 50 years) with bifascicular block and syncope enrolled in the SPRITELY trial. Methods: SPRITELY was a pragmatic, open-label randomized controlled trial with a median follow-up of 33 months. The primary outcome of this analysis is the cost per additional quality-adjusted life-year (QALY). Resource utilization and utility data were collected prospectively, and outcomes at 2 years were compared between the 2 arms. A decision analytic model simulated a 3-year time horizon. Results: The mean cost incurred by participants randomized to the PM arm was $9918, compared to $15,416 (both in Canadian dollars) for participants randomized to the ICM arm. The ICM strategy resulted in 0.167 QALYs fewer than the PM strategy. Cost and QALY outcomes are sensitive to the proportion of participants randomized to the ICM arm who subsequently required PM insertion. In 40,000 iterations of probabilistic sensitivity analysis, the PM strategy resulted in cost-savings in 99.7% of iterations, compared with the ICM strategy. Conclusions: The PM strategy was dominant-that is, less costly and estimated to result in a greater number of QALYs. For patients with unexplained syncope, bifascicular block, and age > 50 years, a PM is more likely to be cost-effective than an ICM.


Contexte: L'essai SPRITELY ( S yncope: P acing or R ecording i n t h e L ater Y ears) a été mené auprès de patients ayant subi une syncope et un bloc bifasciculaire. Elle a montré qu'une méthode de stimulation électrique permanente et empirique du cœur permet de réduire les événements indésirables majeurs plus efficacement qu'une méthode reposant sur les résultats d'un moniteur cardiaque implantable. Notre objectif était de déterminer le rapport coût-efficacité de l'utilisation du moniteur cardiaque implantable par rapport à un stimulateur cardiaque dans la prise en charge de personnes âgées de plus de 50 ans présentant un bloc bifasciculaire et une syncope, inscrits à l'essai SPRITELY. Méthodologie: SPRITELY était un essai contrôlé ouvert et pragmatique à répartition aléatoire, dont le suivi médian était de 33 mois. Le paramètre d'évaluation principal de cette analyse était le coût supplémentaire par année de vie ajustée en fonction de la qualité (AVAQ). Les données sur l'utilisation des ressources et l'utilité ont été recueillies de manière prospective, et les résultats à deux ans ont été comparés entre les deux groupes. Un modèle décisionnel analytique a été utilisé pour simuler un horizon temporel de trois ans. Résultats: Le coût moyen pour les participants répartis aléatoirement dans le groupe utilisant un stimulateur cardiaque était de 9 918 $ CAN comparativement à 15 416 $ CAN pour ceux utilisant un moniteur cardiaque implantable. La stratégie du moniteur cardiaque implantable s'est traduite par une réduction de 0,167 du nombre d'AVAQ par rapport à la stratégie reposant sur le stimulateur cardiaque. Les résultats relatifs aux coûts et aux AVAQ sont sensibles à la proportion de participants répartis aléatoirement dans le groupe du moniteur cardiaque implantable qui ont par la suite dû recevoir un stimulateur cardiaque. Sur 40 000 itérations de l'analyse de sensibilité probabiliste, la stratégie du stimulateur cardiaque a occasionné des économies dans 99,7 % des itérations comparativement à la stratégie du moniteur cardiaque implantable. Conclusions: La stratégie du stimulateur cardiaque était dominante, autrement dit moins coûteuse et, selon les estimations, entraînerait un plus grand nombre d'AVAQ. Pour les patients de plus de 50 ans présentant une syncope idiopathique et un bloc bifasciculaire, un stimulateur cardiaque est plus susceptible d'être moins coûteux qu'un moniteur cardiaque implantable.

16.
J Interv Card Electrophysiol ; 65(2): 481-489, 2022 Nov.
Article En | MEDLINE | ID: mdl-35739438

BACKGROUND: Transseptal puncture to achieve left atrial access is necessary for many cardiac procedures, including atrial fibrillation ablation. More recently, there has been an increasing need for left atrial access using large caliber sheaths, which increases risk of perforation associated with the initial advancement into the left atrium. We compared the effectiveness of a radiofrequency needle-based transseptal system versus conventional needle for transseptal access. METHODS: This prospective controlled trial randomized 161 patients with symptomatic paroxysmal atrial fibrillation undergoing cryoballoon pulmonary vein isolation to transseptal access with a commercially available transseptal system (radiofrequency needle plus stiff pigtail wire; RF + Pigtail group) versus conventional transseptal access (standard group). The primary outcome was time required for left atrial access. Secondary outcomes included failure of the assigned transseptal system, radiation exposure, and complications. RESULTS: The median transseptal puncture time was significantly shorter using the radiofrequency needle plus stiff pigtail wire transseptal system compared with conventional transseptal (840 ± 323 vs. 956 ± 407 s, P = 0.0489). Compared to conventional transseptal puncture, fewer transseptal attempts were required (1.0 ± 0.5 RF applications vs. 1.3 ± 0.8 mechanical punctures, P = 0.0123) and the fluoroscopy time was significantly shorter (72.0 [IQR 48.0, 129.0] vs. 93.0 [IQR 60.0, 171.0] s, P = 0.0490) with the radiofrequency needle plus stiff pigtail wire transseptal system. Failure to achieve transseptal LA access with the assigned system was rarely observed (1.3% vs. 5.7%, P = 0.2192). There were no procedural complications observed with either system. CONCLUSIONS: The use of a radiofrequency needle plus stiff pigtail wire resulted in shorter time to left atrial access and reduced fluoroscopy time compared to left atrial access using conventional transseptal equipment. TRIAL REGISTRATION: ClinicalTrials.gov identifier NCT03199703.


Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Catheter Ablation/methods , Prospective Studies , Punctures , Treatment Outcome
17.
Circulation ; 145(23): 1693-1704, 2022 06 07.
Article En | MEDLINE | ID: mdl-35313733

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) frequently coexist and can be challenging to treat. Pharmacologically based rhythm control of AF has not proven to be superior to rate control. Ablation-based rhythm control was compared with rate control to evaluate if clinical outcomes in patients with HF and AF could be improved. METHODS: This was a multicenter, open-label trial with blinded outcome evaluation using a central adjudication committee. Patients with high-burden paroxysmal (>4 episodes in 6 months) or persistent (duration <3 years) AF, New York Heart Association class II to III HF, and elevated NT-proBNP (N-terminal pro brain natriuretic peptide) were randomly assigned to ablation-based rhythm control or rate control. The primary outcome was a composite of all-cause mortality and all HF events, with a minimum follow-up of 2 years. Secondary outcomes included left ventricular ejection fraction, 6-minute walk test, and NT-proBNP. Quality of life was measured using the Minnesota Living With Heart Failure Questionnaire and the AF Effect on Quality of Life. The primary analysis was time-to-event using Cox proportional hazards modeling. The trial was stopped early because of a determination of apparent futility by the Data Safety Monitoring Committee. RESULTS: From December 1, 2011, to January 20, 2018, 411 patients were randomly assigned to ablation-based rhythm control (n=214) or rate control (n=197). The primary outcome occurred in 50 (23.4%) patients in the ablation-based rhythm-control group and 64 (32.5%) patients in the rate-control group (hazard ratio, 0.71 [95% CI, 0.49-1.03]; P=0.066). Left ventricular ejection fraction increased in the ablation-based group (10.1±1.2% versus 3.8±1.2%, P=0.017), 6-minute walk distance improved (44.9±9.1 m versus 27.5±9.7 m, P=0.025), and NT-proBNP demonstrated a decrease (mean change -77.1% versus -39.2%, P<0.0001). Minnesota Living With Heart Failure Questionnaire demonstrated greater improvement in the ablation-based rhythm-control group (least-squares mean difference of -5.4 [95% CI, -10.5 to -0.3]; P=0.0036), as did the AF Effect on Quality of Life score (least-squares mean difference of 6.2 [95% CI, 1.7-10.7]; P=0.0005). Serious adverse events were observed in 50% of patients in both treatment groups. CONCLUSIONS: In patients with high-burden AF and HF, there was no statistical difference in all-cause mortality or HF events with ablation-based rhythm control versus rate control; however, there was a nonsignificant trend for improved outcomes with ablation-based rhythm control over rate control. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01420393.


Atrial Fibrillation , Catheter Ablation , Heart Failure , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Failure/complications , Heart Failure/diagnosis , Heart Failure/surgery , Humans , Quality of Life , Stroke Volume , Treatment Outcome , Ventricular Function, Left
18.
JACC Clin Electrophysiol ; 8(2): 239-248, 2022 02.
Article En | MEDLINE | ID: mdl-35210082

OBJECTIVES: In this study, the authors tested whether a strategy of empiric permanent pacing reduces major composite events more effectively than acting on the results of an implantable cardiac monitor (ICM). BACKGROUND: Syncope may be caused by intermittent complete heart block in patients with bifascicular heart block, but competing diagnoses coexist. Whether empiric permanent pacing or acting on investigative results provides best care is unknown. METHODS: This was a multinational, randomized, pragmatic clinical trial of patients ≥50 years of age with bifascicular block, preserved left ventricular function, and ≥1 syncope in the preceding year. The primary composite outcome measure comprised cardiovascular death, syncope, bradycardia resulting in pacemaker insertion, and device complications. RESULTS: There were 57 and 58 subjects randomized to receive a pacemaker or ICM. A total of 41 patients had left bundle branch block and 74 had right bundle branch block and a left fascicular block. Patients were followed for a median 33 months. There were fewer composite primary outcomes in patients randomized to pacemaker compared with ICM, respectively (20 [35%] vs 44 [76%]; chi square P < 0.0001), with lower actuarial probabilities of a primary outcome (0.45 and 1.00; P < 0.001). Syncope was as likely in the groups randomized to receive a pacemaker or ICM (29% vs 26%, chi-square P = 0.95). CONCLUSIONS: Empiric permanent pacing compared with ICM reduced major adverse events but not syncope in older patients with bifascicular block and recent syncope. There remains a substantial likelihood of syncope recurrence in patients who receive a permanent pacemaker likely caused by vasodepressor syncope. (Syncope: Pacing or Recording in the Later Years [SPRITELY]; NCT01423994).


Bundle-Branch Block , Pacemaker, Artificial , Aged , Arrhythmias, Cardiac/complications , Bundle-Branch Block/diagnosis , Bundle-Branch Block/therapy , Cardiac Pacing, Artificial/methods , Humans , Syncope/diagnosis , Syncope/etiology , Syncope/therapy
19.
Am Heart J ; 248: 1-12, 2022 06.
Article En | MEDLINE | ID: mdl-35219715

BACKGROUND: Recurrence of atrial fibrillation (AF) after a pulmonary vein isolation procedure is often due to electrical reconnection of the pulmonary veins. Repeat ablation procedures may improve freedom from AF but are associated with increased risks and health care costs. A novel ablation strategy in which patients receive "augmented" ablation lesions has the potential to reduce the risk of AF recurrence. OBJECTIVE: The Augmented Wide Area Circumferential Catheter Ablation for Reduction of Atrial Fibrillation Recurrence (AWARE) Trial was designed to evaluate whether an augmented wide-area circumferential antral (WACA) ablation strategy will result in fewer atrial arrhythmia recurrences in patients with symptomatic paroxysmal AF, compared with a conventional WACA strategy. METHODS/DESIGN: The AWARE trial was a multicenter, prospective, randomized, open, blinded endpoint trial that has completed recruitment (ClinicalTrials.gov NCT02150902). Patients were randomly assigned (1:1) to either the control arm (single WACAlesion set) or the interventional arm (augmented- double WACA lesion set performed after the initial WACA). The primary outcome was atrial tachyarrhythmia (AA; atrial tachycardia [AT], atrial flutter [AFl] or AF) recurrence between days 91 and 365 post catheter ablation. Patient follow-up included 14-day continuous ambulatory ECG monitoring at 3, 6, and 12 months after catheter ablation. Three questionnaires were administered during the trial- the EuroQuol-5D (EQ-5D) quality of life scale, the Canadian Cardiovascular Society Severity of Atrial Fibrillation scale, and a patient satisfaction scale. DISCUSSION: The AWARE trial was designed to evaluate whether a novel approach to catheter ablation reduced the risk of AA recurrence in patients with symptomatic paroxysmal AF.


Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Canada , Catheter Ablation/methods , Humans , Prospective Studies , Pulmonary Veins/surgery , Quality of Life , Recurrence , Treatment Outcome
20.
Europace ; 24(7): 1112-1118, 2022 07 21.
Article En | MEDLINE | ID: mdl-35030257

AIMS: Catheter ablation is superior to escalated antiarrhythmic drugs among patients with ventricular tachycardia (VT) and prior myocardial infarction (MI). However, it is uncertain whether clinical VT characteristics, should influence choice of therapy. The purpose of this study was to evaluate whether presentation with electrical storm and the clinical VT cycle length predicted response to ablation vs. escalated antiarrhythmic therapy. METHODS AND RESULTS: All patients enrolled in the Ventricular Tachycardia Ablation vs. Escalated Antiarrhythmic Drug Therapy in Ischaemic Heart Disease (VANISH) trial were included. The association between VT cycle length and presentation with electrical storm and the primary outcome of death, subsequent VT storm or appropriate ICD shock was evaluated. Among the study population of 259 patients, escalated antiarrhythmic drug therapy had worse outcomes for those presenting with a VT cycle length >400 ms [<150 b.p.m., 89/259, hazard ratio (HR) 1.7 (1.02-3.13)]. This effect was more pronounced among those taking amiodarone at baseline [HR of 2.22 (1.19-4.16)]. Presentation with VT storm (32/259) did not affect the primary outcome between groups. However, those presenting with VT storm on amiodarone had a trend towards worse outcomes with escalated antiarrhythmic therapy [HR 4.31 (0.55-33.93)]. CONCLUSION: The VT cycle length can influence response to either ablation or escalated drug therapy in patients with VT and prior MI. Those with slow VT had improved outcomes with ablation. Patients presenting with electrical storm demonstrated similar outcomes to the overall trial population, with a trend to benefit of catheter ablation, particularly in those on amiodarone.


Amiodarone , Catheter Ablation , Myocardial Infarction , Tachycardia, Ventricular , Amiodarone/therapeutic use , Anti-Arrhythmia Agents/therapeutic use , Catheter Ablation/methods , Humans , Myocardial Infarction/complications , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/drug therapy , Tachycardia, Ventricular/surgery , Treatment Outcome
...