1.
Adv Radiat Oncol ; 6(6): 100793, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34820550

RESUMEN

PURPOSE: Magnetic resonance (MR) elastography (E) is a noninvasive technique for quantifying liver stiffness (LS) for fibrosis. This study evaluates whether LS is associated with risk of developing radiation-induced liver disease (RILD) in patients receiving liver-directed radiation therapy (RT). METHODS AND MATERIALS: Based on prior studies, LS ≤3 kPa was considered normal and LS >3.0 kPa as representing fibrosis. RILD was defined as an increase in Child-Pugh (CP) score of ≥2 from baseline within 1 year of RT. Univariate and multivariate Cox models were used to assess correlation. RESULTS: One hundred two patients, 51 with primary liver tumors and 51 with liver metastases, were identified with sufficient follow-up. In univariate models, pre-RT LS >3.0 kPa (hazard ratio [HR] 4.9; 95% confidence interval [CI], 1.6-14; P = .004), body mass index (BMI), clinical cirrhosis, CP score, albumin-bilirubin (ALBI) grade 2, primary liver tumor, and mean liver dose were significantly associated with risk of post-RT RILD. In a multivariate analysis, LS >3.0 and mean liver dose both were significantly associated with RILD risk. CONCLUSIONS: Elevated pre-RT LS is associated with an increased risk of RILD in patients receiving liver-directed RT.