Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 340
Filtrar
2.
Bone Joint J ; 106-B(7): 640-641, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38945530
3.
Bone Joint J ; 106-B(7): 680-687, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38945538

RESUMEN

Aims: Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up. Methods: This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36). Results: There were no differences between the two treatment groups with regard to mean change in haemoglobin concentration (p = 0.477), length of stay (LOS, p = 0.172), mean polyethylene thickness (p = 0.065), or postoperative complication rates (p = 0.295). At the most recent follow-up, the primary robotic arm-assisted TKA group had a statistically significantly improved OKS compared with the revision UKA to TKA group (44.6 (SD 2.7) vs 42.3 (SD 2.5); p = 0.004) but there was no difference in the overall ROM (p = 0.056) or FJS between the two treatment groups (86.1 (SD 9.6) vs 84.1 (4.9); p = 0.439). Conclusion: Robotic arm-assisted revision of UKA to TKA was associated with comparable intraoperative blood loss, early postoperative rehabilitation, functional outcomes, and complications to primary robotic TKA at short-term follow-up. Robotic arm-assisted surgery offers a safe and reproducible technique for revising failed UKA to TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Reoperación , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Masculino , Femenino , Estudios Prospectivos , Procedimientos Quirúrgicos Robotizados/métodos , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Rango del Movimiento Articular , Estudios de Seguimiento , Tiempo de Internación , Complicaciones Posoperatorias , Prótesis de la Rodilla , Anciano de 80 o más Años , Osteoartritis de la Rodilla/cirugía
4.
Orthop J Sports Med ; 12(6): 23259671241246699, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38840794

RESUMEN

Background: The jackling position within rugby has not been previously described as a mechanism for proximal hamstring injuries. Hypothesis: Acute surgical repair of proximal hamstring avulsion injuries sustained from the jackling contact position enables a return to a previous level of sporting activity with low risk of recurrence. Study Design: Case series; Level of evidence, 4. Methods: This study included 54 professional rugby players (mean age, 26 ± 4.8 years) who underwent acute primary surgical repair of complete, proximal hamstring avulsion injuries. The mean follow-up time was 17 months (range, 12-24 months). Mean isometric hamstring strength and function testing was performed at 3 months and 1 year after repair. Results: Of the 54 players, 51 (94.4%) returned to their preinjury level of sporting activity. The mean time from surgical repair to full sporting activity was 7 months (range, 4-12 months). No patients had recurrence of the primary injury. At 1 year postoperatively, patients had significantly restored mean isometric hamstring muscle strength when compared with the uninjured leg at 0° (98.4% ± 2.8%), 15° (95.9% ± 2.9%), and 45° (92.9% ± 4.1%); improved Lower Extremity Functional Score (78.0 ± 2.0); and improved Marx activity rating score (14.3 ± 1.5) (P < .001 for all). Conclusion: Acute surgical repair of proximal hamstring avulsion injuries caused by the contact jackling position produced a high return to preinjury level of sporting activity, increased muscle strength, and improved functional outcome scores, with a low risk of recurrence at short-term follow-up.

5.
J Arthroplasty ; 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38810812

RESUMEN

BACKGROUND: Preoperative planning in total hip arthroplasty (THA) involves utilizing radiographs or advanced imaging modalities, including computerized tomography scans, for precise prediction of implant sizing and positioning. This study aimed to compare 3-dimensional (3D) versus 2-dimensional (2D) preoperative planning in primary THA with respect to key surgical metrics, including restoration of the horizontal and vertical center of rotation (COR), combined offset, and leg length. METHODS: This study included 60 patients undergoing primary THA for symptomatic hip osteoarthritis (OA), randomly allocated to either robotic arm-assisted or conventional THA. Digital 2D templating and 3D planning using the robotic software were performed for all patients. All measurements to evaluate the accuracy of templating methods were conducted on the preoperative computerized tomography scanogram, using the contralateral hip as a reference. Sensitivity analyses explored differences between 2D and 3D planning in patients who had superolateral or medial OA patterns. RESULTS: Compared to 2D templating, 3D templating was associated with less medialization of the horizontal COR (-1.2 versus -0.2 mm, P = .002) and more accurate restoration of the vertical COR (1.63 versus 0.3 mm, P < .001) with respect to the contralateral side. Furthermore, 3D templating was superior for planned restoration of leg length (+0.23 versus -0.74 mm, P = .019). Sensitivity analyses demonstrated that in patients who had medial OA, 3D planning resulted in less medialization of horizontal COR and less offset reduction. Conversely, in patients who had superolateral OA, there was less lateralization of horizontal COR and less offset increase using 3D planning. Additionally, 3D planning showed superior reproducibility for stem, acetabular cup sizes, and neck angle, while 2D planning often led to smaller stem and cup sizes. CONCLUSIONS: Our findings indicated higher accuracy in the planned restoration of native joint mechanics using 3D planning. Additionally, this study highlights distinct variances between the 2 planning methods across different OA pattern subtypes, offering valuable insights for clinicians employing 2D planning.

6.
Bone Joint J ; 106-B(5 Supple B): 139, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38689570
7.
J Bone Joint Surg Am ; 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38739702

RESUMEN

BACKGROUND: The objective of this study was to evaluate the correlation in measurements of the lower-limb coronal alignment between long-leg radiographs (LLRs) and computed tomography (CT) scanograms that were made during preoperative planning for robotic-arm-assisted knee arthroplasty. On the basis of published evidence demonstrating a good correlation between these imaging modalities in measuring the lower-limb mechanical axis, we hypothesized that there would be no significant differences between the 2 in the present study. METHODS: This multicenter cohort study across 3 tertiary centers included 300 patients undergoing primary robotic-arm-assisted total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA) for whom LLRs and CT scanograms were available preoperatively. The study involved measuring the medial proximal tibial angle (MPTA), lateral distal femoral angle (LDFA), hip-knee-ankle angle (HKA), joint line obliquity (JLO), joint-line convergence angle (JLCA), and arithmetic HKA (aHKA). The aHKA represents a method for estimating constitutional alignment using angles that are unaffected by joint-space narrowing. RESULTS: Strong correlations (p < 0.001) between the imaging modalities were found for the HKA (correlation coefficient, 0.912), aHKA (0.883), MPTA (0.820), LDFA (0.871), and JLO (0.778). A weaker correlation was observed for the JLCA in valgus knees as compared with varus knees (Spearman coefficients, 0.412 and 0.518, respectively). Regression models demonstrated that the degree of agreement was associated with the preoperative intra-articular deformity and the positioning of the lower limb during the CT scan (i.e., the lower-limb rotational angle). An initial JLCA within ±5° was associated with higher agreement. CONCLUSIONS: We observed a strong correlation between LLRs and CT scanograms that were made during the preoperative planning stage of robotic-arm-assisted knee arthroplasty, implying that CT scanograms can reliably be utilized to estimate the coronal alignment of the knee, potentially replacing the need for LLRs. Nevertheless, to attain a higher degree of agreement, it is crucial to ensure appropriate radiographic positioning of the lower limb. Additionally, surgeons must remain vigilant regarding potential discrepancies in cases involving substantial deformities. LEVEL OF EVIDENCE: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.

10.
Ther Innov Regul Sci ; 58(4): 622-633, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38634983

RESUMEN

BACKGROUND: Linagliptin is an oral dipeptidyl peptidase DPP-4 inhibitor, which is indicated for the treatment of Type 2 diabetes mellitus (T2DM) as monotherapy or add-on to therapy with other hypoglycemic drugs. OBJECTIVES: We aimed to summarize the evidence from randomized controlled trials (RCTs) to assess the safety of linagliptin focusing on cardiovascular risks among subjects with type 2 diabetes mellitus. METHODS: We conducted a systematic search across the following databases: Medline, Embase, the Cochrane Central Register of Controlled Trials and ClinicalTrials.gov from inception to November 2021. Randomized controlled trials (RCTs) of linagliptin compared to placebo in patients with Type 2 diabetes were included. The primary safety points were cardiovascular (CV) adverse events including non-fatal stroke, non-fatal myocardial infarction (MI), CV death, MI, stroke, and hospitalization for unstable angina. While, secondary safety points included 17 reported adverse events such as infections, hypoglycemia and abdominal pain. Three reviewers independently screened and reviewed each study to extract relevant information. Any discrepancies were resolved by consensus. We conducted a meta-analysis using the random effects model. Pooled risk ratios (RRs) of targeted adverse events with linagliptin compared to placebo were estimated using the Mantel-Haenszel test. RESULTS: A total of 24 studies with 19,981 adult patients were included. There was no difference in the incidence of all CV adverse events or individual CV adverse events between linagliptin and the placebo arms. The pooled estimate of the risk of upper respiratory tract infection was reported in twelve trials with a 38% risk reduction among patients treated with the linagliptin group compared to the placebo group (RR = 0.62, 95% CI: 0.45-0.85, and I2 = 0%), while no difference was found in other infections. For gastrointestinal disorders, the risk of abdominal pain showed a 65% risk reduction among patients treated with the linagliptin group compared to the placebo group (RR = 0.35, 95% CI: 0.16-0.77, and I2 = 0%). CONCLUSION: Our study showed an overall acceptable safety profile of linagliptin in patients with T2DM. Moreover, our study showed a risk reduction of upper respiratory tract infection and abdominal pain when using linagliptin compared to placebo.


Asunto(s)
Diabetes Mellitus Tipo 2 , Inhibidores de la Dipeptidil-Peptidasa IV , Linagliptina , Ensayos Clínicos Controlados Aleatorios como Asunto , Humanos , Enfermedades Cardiovasculares/inducido químicamente , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Inhibidores de la Dipeptidil-Peptidasa IV/uso terapéutico , Inhibidores de la Dipeptidil-Peptidasa IV/efectos adversos , Hipoglucemiantes/uso terapéutico , Hipoglucemiantes/efectos adversos , Linagliptina/uso terapéutico , Linagliptina/efectos adversos
13.
Bone Joint J ; 106-B(4): 324-335, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38555946

RESUMEN

Aims: Achieving accurate implant positioning and restoring native hip biomechanics are key surgeon-controlled technical objectives in total hip arthroplasty (THA). The primary objective of this study was to compare the reproducibility of the planned preoperative centre of hip rotation (COR) in patients undergoing robotic arm-assisted THA versus conventional THA. Methods: This prospective randomized controlled trial (RCT) included 60 patients with symptomatic hip osteoarthritis undergoing conventional THA (CO THA) versus robotic arm-assisted THA (RO THA). Patients in both arms underwent pre- and postoperative CT scans, and a patient-specific plan was created using the robotic software. The COR, combined offset, acetabular orientation, and leg length discrepancy were measured on the pre- and postoperative CT scanogram at six weeks following surgery. Results: There were no significant differences for any of the baseline characteristics including spinopelvic mobility. The absolute error for achieving the planned horizontal COR was median 1.4 mm (interquartile range (IQR) 0.87 to 3.42) in RO THA versus 4.3 mm (IQR 3 to 6.8; p < 0.001); vertical COR mean 0.91 mm (SD 0.73) in RO THA versus 2.3 mm (SD 1.3; p < 0.001); and combined offset median 2 mm (IQR 0.97 to 5.45) in RO THA versus 3.9 mm (IQR 2 to 7.9; p = 0.019). Improved accuracy was observed with RO THA in achieving the desired acetabular component positioning (root mean square error for anteversion and inclination was 2.6 and 1.3 vs 8.9 and 5.3, repectively) and leg length (mean 0.6 mm vs 1.4 mm; p < 0.001). Patient-reported outcome measures were comparable between the two groups at baseline and one year. Participants in the RO THA group needed fewer physiotherapy sessions postoperatively (median six (IQR 4.5 to 8) vs eight (IQR 6 to 11; p = 0.005). Conclusion: This RCT suggested that robotic-arm assistance in THA was associated with improved accuracy in restoring the native COR, better preservation of the combined offset, leg length correction, and superior accuracy in achieving the desired acetabular component positioning. Further evaluation through long-term and registry data is necessary to assess whether these findings translate into improved implant survival and functional outcomes.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Procedimientos Quirúrgicos Robotizados , Humanos , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Tomografía Computarizada por Rayos X , Estudios Prospectivos
14.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 798-810, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38426562

RESUMEN

PURPOSE: The aim of this study was to describe the 10-year findings from the UK National Ligament Registry (NLR). METHODS: A retrospective review was performed for prospectively collected data on the NLR between January 2013 and December 2022. All patients who underwent primary ACL reconstruction (ACLR) on the registry were included. Surgical characteristics were analysed, including surgeon grade and case volume, concomitant knee procedures, venous thromboembolic prophylaxis, graft characteristics, femoral and tibial tunnel drilling, and fixation methods. Clinical outcomes were collected preoperatively and at 6 months, 1 year, 2 years and 5 years following the index procedure. RESULTS: During the study period, 17,492 unilateral ACLR procedures were recorded. Autograft was used in 98%, most commonly a combined semitendinosus and gracilis graft (77%) or patella tendon graft (31%). Allograft was used in only 1% of the patients. In 52% of cases, ACLR was associated with an additional procedure, with isolated medial meniscal surgery being the most common (21%). Femoral tunnel drilling was mostly performed through an anteromedial portal (73%) and tibial tunnel drilling using an outside-in technique (92%). The most common method of femoral graft fixation was with an Endobutton fixed loop suspensory device (77%), while interference screws predominated for tibial tunnel fixation (86%). Patients who underwent ACLR surgery showed significant improvement in their functional outcome scores at six months, 1 year, 2 years and 5 years postoperatively. CONCLUSION: Data from the NLR shows a detailed description of the current trends and evolution of ACLR in the United Kingdom over the last 10 years. Satisfactory functional outcomes were observed 5 years postoperatively. This study provides useful information on the prevalence of ACL-associated injuries and current surgical techniques with the aim of improving the quality of clinical care and patients' outcomes. Moreover, it provides surgeons with a benchmark against which to compare current practices and functional outcomes following ACLR across the United Kingdom. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Ligamento Rotuliano , Humanos , Reconstrucción del Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/cirugía , Ligamento Rotuliano/cirugía , Sistema de Registros
17.
Bone Joint J ; 106-B(3 Supple A): 24-30, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38423091

RESUMEN

Aims: Postoperative length of stay (LOS) and discharge dispositions following arthroplasty can be used as surrogate measurements for improvements in patients' pathways and costs. With the increasing use of robotic technology in arthroplasty, it is important to assess its impact on LOS. The aim of this study was to identify factors associated with decreased LOS following robotic arm-assisted total hip arthroplasty (RO THA) compared with the conventional technique (CO THA). Methods: This large-scale, single-institution study included 1,607 patients of any age who underwent 1,732 primary THAs for any indication between May 2019 and January 2023. The data which were collected included the demographics of the patients, LOS, type of anaesthetic, the need for treatment in a post-anaesthesia care unit (PACU), readmission within 30 days, and discharge disposition. Univariate and multivariate logistic regression models were used to identify factors and the characteristics of patients which were associated with delayed discharge. Results: The multivariate model identified that age, female sex, admission into a PACU, American Society of Anesthesiologists grade > II, and CO THA were associated with a significantly higher risk of a LOS of > two days. The median LOS was 54 hours (interquartile range (IQR) 34 to 78) in the RO THA group compared with 60 hours (IQR 51 to 100) in the CO THA group (p < 0.001). The discharge dispositions were comparable between the two groups. A higher proportion of patients undergoing CO THA required PACU admission postoperatively, although without reaching statistical significance (7.2% vs 5.2%, p = 0.238). Conclusion: We found that among other baseline characteristics and comorbidities, RO THA was associated with a significantly shorter LOS, with no difference in discharge destination. With the increasing demand for THA, these findings suggest that robotic assistance in THA could reduce costs. However, randomized controlled trials are required to investigate the cost-effectiveness of this technology.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Procedimientos Quirúrgicos Robotizados , Humanos , Femenino , Recién Nacido , Artroplastia de Reemplazo de Cadera/métodos , Tiempo de Internación , Costos y Análisis de Costo , Comorbilidad
18.
Bone Joint J ; 106-B(3): 220-223, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38423108
20.
Bone Jt Open ; 5(2): 94-100, 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38310925

RESUMEN

Anterior cruciate ligament (ACL) injuries are among the most common and debilitating knee injuries in professional athletes with an incidence in females up to eight-times higher than their male counterparts. ACL injuries can be career-threatening and are associated with increased risk of developing knee osteoarthritis in future life. The increased risk of ACL injury in females has been attributed to various anatomical, developmental, neuromuscular, and hormonal factors. Anatomical and hormonal factors have been identified and investigated as significant contributors including osseous anatomy, ligament laxity, and hamstring muscular recruitment. Postural stability and impact absorption are associated with the stabilizing effort and stress on the ACL during sport activity, increasing the risk of noncontact pivot injury. Female patients have smaller diameter hamstring autografts than males, which may predispose to increased risk of re-rupture following ACL reconstruction and to an increased risk of chondral and meniscal injuries. The addition of an extra-articular tenodesis can reduce the risk of failure; therefore, it should routinely be considered in young elite athletes. Prevention programs target key aspects of training including plyometrics, strengthening, balance, endurance and stability, and neuromuscular training, reducing the risk of ACL injuries in female athletes by up to 90%. Sex disparities in access to training facilities may also play an important role in the risk of ACL injuries between males and females. Similarly, football boots, pitches quality, and football size and weight should be considered and tailored around females' characteristics. Finally, high levels of personal and sport-related stress have been shown to increase the risk of ACL injury which may be related to alterations in attention and coordination, together with increased muscular tension, and compromise the return to sport after ACL injury. Further investigations are still necessary to better understand and address the risk factors involved in ACL injuries in female athletes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA