Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 48
1.
Anal Chem ; 96(21): 8641-8647, 2024 May 28.
Article En | MEDLINE | ID: mdl-38716697

Pathogenic bacterial infections, even at extremely low concentrations, pose significant threats to human health. However, the challenge persists in achieving high-sensitivity bacterial detection, particularly in complex samples. Herein, we present a novel sandwich-type electrochemical sensor utilizing bacteria-imprinted polymer (BIP) coupled with vancomycin-conjugated MnO2 nanozyme (Van@BSA-MnO2) for the ultrasensitive detection of pathogenic bacteria, exemplified by Staphylococcus aureus (S. aureus). The BIP, in situ prepared on the electrode surface, acts as a highly specific capture probe by replicating the surface features of S. aureus. Vancomycin (Van), known for its affinity to bacterial cell walls, is conjugated with a Bovine serum albumin (BSA)-templated MnO2 nanozyme through EDC/NHS chemistry. The resulting Van@BSA-MnO2 complex, serving as a detection probe, provides an efficient catalytic platform for signal amplification. Upon binding with the captured S. aureus, the Van@BSA-MnO2 complex catalyzes a substrate reaction, generating a current signal proportional to the target bacterial concentration. The sensor displays remarkable sensitivity, capable of detecting a single bacterial cell in a phosphate buffer solution. Even in complex milk matrices, it maintains outstanding performance, identifying S. aureus at concentrations as low as 10 CFU mL-1 without requiring intricate sample pretreatment. Moreover, the sensor demonstrates excellent selectivity, particularly in distinguishing target S. aureus from interfering bacteria of the same genus at concentrations 100-fold higher. This innovative method, employing entirely synthetic materials, provides a versatile and low-cost detection platform for Gram-positive bacteria. In comparison to existing nanozyme-based bacterial sensors with biological recognition materials, our assay offers distinct advantages, including enhanced sensitivity, ease of preparation, and cost-effectiveness, thereby holding significant promise for applications in food safety and environmental monitoring.


Manganese Compounds , Oxides , Polymers , Staphylococcus aureus , Vancomycin , Staphylococcus aureus/isolation & purification , Manganese Compounds/chemistry , Oxides/chemistry , Vancomycin/chemistry , Polymers/chemistry , Serum Albumin, Bovine/chemistry , Electrochemical Techniques/methods , Single-Cell Analysis , Anti-Bacterial Agents/chemistry , Anti-Bacterial Agents/pharmacology , Animals , Limit of Detection , Molecularly Imprinted Polymers/chemistry , Humans
2.
Biosensors (Basel) ; 14(4)2024 Apr 04.
Article En | MEDLINE | ID: mdl-38667167

Exosomes, with diameters ranging from 30 to 150 nm, are saucer-shaped extracellular vesicles (EVs) secreted by various type of human cells. They are present in virtually all bodily fluids. Owing to their abundant nucleic acid and protein content, exosomes have emerged as promising biomarkers for noninvasive molecular diagnostics. However, the need for exosome separation purification presents tremendous technical challenges due to their minuscule size. In recent years, microfluidic technology has garnered substantial interest as a promising alternative capable of excellent separation performance, reduced reagent consumption, and lower overall device and operation costs. In this context, we hereby propose a novel microfluidic strategy based on thermally oxidized deterministic lateral displacement (DLD) arrays with tapered shapes to enhance separation performance. We have achieved more than 90% purity in both polystyrene nanoparticle and exosome experiments. The use of thermal oxidation also significantly reduces fabrication complexity by avoiding the use of high-precision lithography. Furthermore, in a simulation model, we attempt to integrate the use of dielectrophoresis (DEP) to overcome the size-based nature of DLD and distinguish particles that are close in size but differ in biochemical compositions (e.g., lipoproteins, exomeres, retroviruses). We believe the proposed strategy heralds a versatile and innovative platform poised to enhance exosome analysis across a spectrum of biochemical applications.


Electrophoresis , Exosomes , Humans , Microfluidic Analytical Techniques , Microfluidics , Nanoparticles/chemistry , Oxidation-Reduction
3.
Anal Chim Acta ; 1285: 342007, 2024 Jan 02.
Article En | MEDLINE | ID: mdl-38057056

BACKGROUND: The identification and quantification of viable Escherichia coli (E. coli) are important in multiple fields including the development of antimicrobial materials, water quality, food safety and infections diagnosis. However, the standard culture-based methods of viable E. coli detection suffer from long detection times (24 h) and complex operation, leaving the unmet requirement for fast assessing the efficiency of antimicrobial materials, early alerting the contamination of water and food, and immediately treatment of infections. RESULTS: We present a digital ß-d-glucuronidase (GUS) assay in a self-priming polydimethylsiloxane (PDMS) microfluidic chip for rapid E. coli identification and quantification. The GUS expression in viable bacteria was investigated to develop a fast GUS assay at the single-cell level. Single E. coli were stochastically discretized in picoliter chambers and identified by specific GUS activity. The digital GUS assay enabled identifying E. coli within 3 h and quantifying within 4 h for different E. coli subtypes. The specificity of our method was confirmed by using blended bacteria including E. coli, Bacillus, Shigella and Vibrio. We utilized digital GUS assay to enumerate viable E. coli after incubated with antibacterial materials for assessing the antibacterial efficiency. Moreover, the degassed chip can realize automatic sample distribution without external instruments. SIGNIFICANCE: The results demonstrated the functionality and practicability of digital GUS assay for single E. coli identification and quantification. With air-tight packaging, the developed chip has the potential for on-site E. coli analysis and could be deployed for diagnosis of E. coli infections, antimicrobial susceptibility testing, and warning the fecal pollution of water. Digital GUS assay provides a paradigm, examining the activity of metabolic enzyme, for detecting the viable bacteria other than E. coli.


Escherichia coli , Water Quality , Escherichia coli/metabolism , Microfluidics , Anti-Bacterial Agents/pharmacology , Glucuronidase/metabolism
4.
Anal Chem ; 95(42): 15585-15594, 2023 10 24.
Article En | MEDLINE | ID: mdl-37843131

Determining the grade of glioma is a critical step in choosing patients' treatment plans in clinical practices. The pathological diagnosis of patient's glioma samples requires extensive staining and imaging procedures, which are expensive and time-consuming. Current advanced uniform-width-constriction-channel-based microfluidics have proven to be effective in distinguishing cancer cells from normal tissues, such as breast cancer, ovarian cancer, prostate cancer, etc. However, the uniform-width-constriction channels can result in low yields on glioma cells with irregular morphologies and high heterogeneity. In this research, we presented an innovative cyclic conical constricted (CCC) microfluidic device to better differentiate glioma cells from normal glial cells. Compared with the widely used uniform-width-constriction microchannels, the new CCC configuration forces single cells to deform gradually and obtains the biophysical attributes from each deformation. The human-derived glioma cell lines U-87 and U-251, as well as the human-derived normal glial astrocyte cell line HA-1800 were selected as the proof of concept. The results showed that CCC channels can effectively obtain the biomechanical characteristics of different 12-25 µm glial cell lines. The patient glioma samples with WHO grades II, III, and IV were tested by CCC channels and compared between Elastic Net (ENet) and Lasso analysis. The results demonstrated that CCC channels and the ENet can successfully select critical biomechanical parameters to differentiate the grades of single-glioma cells. This CCC device can be potentially further applied to the extensive family of brain tumors at the single-cell level.


Brain Neoplasms , Glioma , Ovarian Neoplasms , Prostatic Neoplasms , Male , Female , Humans , Microfluidics/methods , Glioma/pathology , Brain Neoplasms/pathology , Prostatic Neoplasms/pathology
5.
Anal Chim Acta ; 1271: 341469, 2023 Aug 29.
Article En | MEDLINE | ID: mdl-37328249

Traditional nucleic acid extraction and detection is based on open operation, which may cause cross-contamination and aerosol formation. This study developed a droplet magnetic-controlled microfluidic chip integrated nucleic acid extraction, purification and amplification. The reagent is sealed in oil to form a droplet, and the nucleic acid is extracted and purified by controlling the movement of the magnetic beads (MBs) through a permanent magnet, ensuring a closed environment. This chip can automatically extract nucleic acid from multiple samples within 20 min, and can be directly placed in the in situ amplification instrument for amplification without further transfer of nucleic acid, characterized by simple, fast, time-saving and labor-saving. The results showed that the chip was able to detect <10 copies/test SARS-CoV-2 RNA, and EGFR exon 21 L858R mutations were detected in H1975 cells as low as 4 cells. In addition, on the basis of the droplet magnetic-controlled microfluidic chip, we further developed a multi-target detection chip, which used MBs to divide the nucleic acid of the sample into three parts. And the macrolides resistance mutations A2063G and A2064G, and the P1 gene of mycoplasma pneumoniae (MP) were successfully detected in clinical samples by the multi-target detection chip, providing the possibility for future application in the detection of multiple pathogens.


COVID-19 , Neoplasms , Nucleic Acids , Humans , Nucleic Acids/genetics , Microfluidics , RNA, Viral , Nucleic Acid Amplification Techniques/methods , COVID-19/diagnosis , SARS-CoV-2 , Magnetic Phenomena
6.
Cyborg Bionic Syst ; 4: 0023, 2023.
Article En | MEDLINE | ID: mdl-37287460

Magnetic beads manipulation in microfluidic chips is a promising research field for biological application, especially in the detection of biological targets. In this review, we intend to present a thorough and in-depth overview of recent magnetic beads manipulation in microfluidic chips and its biological application. First, we introduce the mechanism of magnetic manipulation in microfluidic chip, including force analysis, particle properties, and surface modification. Then, we compare some existing methods of magnetic manipulation in microfluidic chip and list their biological application. Besides, the suggestions and outlook for future developments in the magnetic manipulation system are also discussed and summarized.

7.
Biosensors (Basel) ; 13(5)2023 May 05.
Article En | MEDLINE | ID: mdl-37232879

We developed a microfluidic chip integrated with nucleic acid purification and droplet-based digital polymerase chain reaction (ddPCR) modules to realize a 'sample-in, result-out' infectious virus diagnosis. The whole process involved pulling magnetic beads through drops in an oil-enclosed environment. The purified nucleic acids were dispensed into microdroplets by a concentric-ring, oil-water-mixing, flow-focusing droplets generator driven under negative pressure conditions. Microdroplets were generated with good uniformity (CV = 5.8%), adjustable diameters (50-200 µm), and controllable flow rates (0-0.3 µL/s). Further verification was provided by quantitative detection of plasmids. We observed a linear correlation of R2 = 0.9998 in the concentration range from 10 to 105 copies/µL. Finally, this chip was applied to quantify the nucleic acid concentrations of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The measured nucleic acid recovery rate of 75 ± 8.8% and detection limit of 10 copies/µL proved its on-chip purification and accurate detection abilities. This chip can potentially be a valuable tool in point-of-care testing.


COVID-19 , Nucleic Acids , Humans , SARS-CoV-2 , COVID-19/diagnosis , Polymerase Chain Reaction , Nucleic Acids/analysis , Oligonucleotide Array Sequence Analysis
8.
Analyst ; 148(12): 2758-2766, 2023 Jun 12.
Article En | MEDLINE | ID: mdl-37194305

This paper introduces an enclosed microfluidic chip that integrates sample preparation and the chamber-based digital polymerase chain reaction (cdPCR). The sample preparation of the chip includes nucleic acid extraction and purification based on magnetic beads, which adsorb nucleic acids by moving around the reaction chambers to complete the reactions including lysis, washing, and elution. The cdPCR area of the chip consists of tens of thousands of regularly arranged microchambers. After the sample preparation processes are completed, the purified nucleic acid can be directly introduced into the microchambers for amplification and detection on the chip. The nucleic acid extraction performance and digital quantification performance of the system were examined using synthetic SARS-CoV-2 plasmid templates at concentrations ranging from 101-105 copies per µL. Further on, a simulated clinical sample was used to test the system, and the integrated chip was able to accurately detect SARS-CoV-2 virus particle samples doped with interference (saliva) with a detection limit of 10 copies per µL. This integrated system could provide a promising tool for point-of-care testing of pathogenic infections.


Microfluidics , Microfluidics/methods , Polymerase Chain Reaction , Nucleic Acids/analysis , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification
9.
Anal Chim Acta ; 1251: 340995, 2023 Apr 22.
Article En | MEDLINE | ID: mdl-36925286

BACKGROUND: Rapid diagnosis of harmful microorganisms demonstrated its great importance for social health. Continuous flow PCR (CF-PCR) can realize rapid amplification of target genes by placing the microfluidic chip on heaters with different temperature. However, bubbles and evaporation always arise from heating, which makes the amplification not stable. Water-in-oil droplets running in CF-PCR microfluidic chip with uniform height takes long time because of the high resistance induced by long meandering microchannel. To overcome those drawbacks, we proposed a double-layer droplet CF-PCR microfluidic chip to reduce the fluidic resistance, and meanwhile nanoliter droplets were generated to minimize the bubbles and evaporation. RESULTS: Experiments showed that (1) fluidic resistance could be reduced with the increase of the height of the serpentine microchannel if the height of the T-junction part was certain. (2) Running speed, the size and the number of generated droplets were positively correlated with the cross-sectional area of the T-junction and water pressure. (3) Droplet fusion happened at higher water pressure if other experimental conditions were the same. (4) 0.032 nL droplet was created if the cross-sectional area of T-junction and water pressure were 1600 µm2 (40 × 40 µm) and 7 kPa, respectively. Finally, we successfully amplified the target genes of Porphyromonas gingivalis within 11'16″ and observed the fluorescence from droplets. SIGNIFICANCE AND NOVELTY: Such a microfluidic chip can effectively reduce the high resistance induced by long meandering microchannel, and greatly save time required for droplets CF-PCR. It offers a new way for the rapid detection of bacterial.


Microfluidic Analytical Techniques , Microfluidics , Polymerase Chain Reaction , Water , Bacteria/genetics
10.
Nano Lett ; 23(7): 2502-2510, 2023 04 12.
Article En | MEDLINE | ID: mdl-36926974

Self-propelled micro/nanomotors are emergent intelligent sensors for analyzing extracellular biomarkers in circulating biological fluids. Conventional luminescent motors are often masked by a highly dynamic and scattered environment, creating challenges to characterize biomarkers or subtle binding dynamics. Here we introduce a strategy to amplify subtle signals by coupling strong light-matter interactions on micromotors. A smart whispering-gallery-mode microlaser that can self-propel and analyze extracellular biomarkers is demonstrated through a liquid crystal microdroplet. Lasing spectral responses induced by cavity energy transfer were employed to reflect the abundance of protein biomarkers, generating exclusive molecular labels for cellular profiling of exosomes derived from 3D multicellular cancer spheroids. Finally, a microfluidic biosystem with different tumor-derived exosomes was employed to elaborate its sensing capability in complex environments. The proposed autonomous microlaser exhibits a promising method for both fundamental biological science and applications in drug screening, phenotyping, and organ-on-chip applications.


Extracellular Vesicles , Neoplasms , Humans , Luminescence , Microfluidics
11.
Analyst ; 148(9): 1939-1947, 2023 May 02.
Article En | MEDLINE | ID: mdl-36916483

Diagnosis of cancer by biomarkers plays an important role in human health and life. However, current laboratory techniques for detecting cancer biomarkers still require laborious and time-consuming operation by skilled operators and associated laboratory instruments. This work presents a colorimetric biosensor for the rapid and sensitive detection of carcinoembryonic antigen (CEA) based on an automated immunomagnetic separation platform and a droplet array microfluidic chip with the aid of an image analysis system. Immunomagnetic nanoparticles (MNPs) were used to capture CEA in the samples. CEA-detecting antibodies and horseradish peroxidase (HRP) were modified on polystyrene microspheres (PS), catalysing hydrogen peroxide and 3,3',5,5'-tetramethylbenzidine (TMB) as signal outputs. Color reaction data were analyzed to establish a CEA concentration standard curve. The movement of MNPs between droplets in the microfluidic chip is achieved using an automatically programmable magnetic control system. This colorimetric biosensor has been used for the simultaneous detection of six CEA samples ranging from 100 pg mL-1 to 100 ng mL-1 with a detection limit of 14.347 pg mL-1 in 10 min, following the linear equation: y = -4.773 ln(x) + 156.26 with a correlation of R2 = 0.9924, and the entire workflow can be completed within 80 minutes. The microfluidic immunosensor designed in this paper has the advantages of low cost, automation, low sample consumption, high throughput, and promising applications in biochemistry.


Biosensing Techniques , Metal Nanoparticles , Humans , Carcinoembryonic Antigen/analysis , Immunomagnetic Separation/methods , Microfluidics , Immunoassay/methods , Biosensing Techniques/methods , Antibodies, Monoclonal , Limit of Detection , Gold
12.
Biosensors (Basel) ; 13(2)2023 Jan 19.
Article En | MEDLINE | ID: mdl-36831923

Traditional exercise training monitoring is based on invasive blood testing methods. As sweat can reveal abundant blood-related physiological information about health, wearable sweat sensors have received significant research attention and become increasingly popular in the field of exercise training monitoring. However, most of these sensors are used to measure physical indicators such as heart rate, blood pressure, respiration, etc., demanding a versatile sensor that can detect relevant biochemical indicators in body fluids. In this work, we proposed a wearable microfluidic sweat chip combined with smartphone image processing to realize non-invasive in situ analysis of epidermal sweat for sports practitioners. The polydimethylsiloxane (PDMS) based chip was modified with nonionic surfactants to ensure good hydrophilicity for the automatic collection of sweat. Besides, a simple, reliable, and low-cost paper-based sensor was prepared for high-performance sensing of glucose concentration and pH in sweat. Under optimized conditions, this proposed chip can detect glucose with low concentrations from 0.05 mM to 0.40 mM, with a pH range of 4.0 to 6.5 for human sweat. The ability of this microfluidic chip for human sweat analysis was demonstrated by dynamically tracking the changes in glucose concentration and pH in long-distance running subjects.


Biosensing Techniques , Running , Wearable Electronic Devices , Humans , Glucose/analysis , Sweat/chemistry , Biosensing Techniques/methods , Microfluidics , Exercise , Hydrogen-Ion Concentration
13.
Biosensors (Basel) ; 13(2)2023 Feb 15.
Article En | MEDLINE | ID: mdl-36832040

Obesity is one of the foremost public health concerns. Human pancreatic lipase (hPL), a crucial digestive enzyme responsible for the digestion of dietary lipids in humans, has been validated as an important therapeutic target for preventing and treating obesity. The serial dilution technique is commonly used to generate solutions with different concentrations and can be easily modified for drug screening. Conventional serial gradient dilution is often performed with tedious multiple manual pipetting steps, where it is difficult to precisely control fluidic volumes at low microliter levels. Herein, we presented a microfluidic SlipChip that enabled formation and manipulation of serial dilution array in an instrument-free manner. With simple slipping steps, the compound solution could be diluted to seven gradients with the dilution ratio of 1:1 and co-incubated with the enzyme (hPL)-substrate system for screening the anti-hPL potentials. To ensure complete mixing of solution and diluent during continuous dilution, we established a numerical simulation model and conducted an ink mixing experiment to determine the mixing time. Furthermore, we also demonstrated the serial dilution ability of the proposed SlipChip using standard fluorescent dye. As a proof of concept, we tested this microfluidic SlipChip using one marketed anti-obesity drug (Orlistat) and two natural products (1,2,3,4,6-penta-O-galloyl-ß-D-glucopyranose (PGG) and sciadopitysin) with anti-hPL potentials. The IC50 values of these agents were calculated as 11.69 nM, 8.22 nM and 0.80 µM, for Orlistat, PGG and sciadopitysin, respectively, which were consistent with the results obtained by conventional biochemical assay.


Lipase , Microfluidics , Humans , Orlistat , Proteins , Obesity , Indicator Dilution Techniques
14.
Int J Bioprint ; 9(1): 623, 2023.
Article En | MEDLINE | ID: mdl-36636131

In the evolving three-dimensional (3D) printing technology, the involvement of different materials in any new 3D printing process necessitates a thorough evaluation of the product's biocompatibility for biomedical application. Here, we examined the ability of Multi Jet Fusion (MJF)-printed PA-12 to support cell proliferation and osteogenesis. Our results show that leachate from MJF-printed PA-12 does not inhibit the growth of L929 fibroblast and MC3T3e1 osteoblast. The substrate supports the attachment and proliferation of both cell types, though not at a level comparable to conventional polystyrene culture plate. Neither plasma treatment, poly-D-lysine, nor collagen coatings narrowed the gap substantially, suggesting the possible influence of other limiting factors. The substrate can also support MC3T3e1 osteogenesis. However, MJF-printed PA-12 exhibits varying ability in supporting the proliferation of different cell types, especially in subsequent passages. While L929's proliferation is comparable from passage-to-passage, MC3T3e1's growth ability is noticeably compromised. Interestingly, our results show that L929 subcultured back to polystyrene plate retains the ability to grow as robustly as those on the conventional plate, suggesting that MJF-printed PA-12 does not permanently impair cell proliferation. In addition, we have shown the successful culture of bacterial Escherichia coli on MJF-printed PA-12. Together, our study demonstrated the potential of MJF-printed PA-12 for biological applications.

15.
Anal Chim Acta ; 1239: 340737, 2023 Jan 25.
Article En | MEDLINE | ID: mdl-36628732

Okadaic acid (OA) is a marine biotoxin that accumulates in seafood and can cause diarrheic shellfish poisoning if consumed. Accordingly, many countries have established regulatory limits for the content of OA in shellfish. At present, methods used for the detection of marine toxins are time-consuming and labor-intensive. In order to realize rapid, simple, and accurate detection of OA, we developed a novel microfluidic immunosensor based on magnetic beads modified with a highly specific and sensitive monoclonal antibody (mAb) against OA that is used in conjunction with smartphone imaging to realize the rapid detection of OA in shellfish. The method achieves on-site detection results within 1 h with an IC50 value of 3.30 ng/mL for OA and a limit of detection (LOD) of 0.49 ng/mL. In addition, the analysis of real samples showed that the recoveries for spiked shellfish samples ranged from 84.91% to 95.18%, and the results were confirmed by indirect competitive enzyme-linked immunosorbent assay (icELISA), indicating that the method has good accuracy and precision. Furthermore, the results are reported in a specially designed smartphone app. The microfluidic immunosensor has the advantages of simple operation, rapid detection, and high sensitivity, providing a reliable technical solution for detecting OA residues in shellfish.


Biosensing Techniques , Okadaic Acid/analysis , Microfluidics , Immunoassay/methods , Shellfish/analysis , Seafood/analysis , Magnetic Phenomena
16.
Zhonghua Nan Ke Xue ; 29(9): 856-858, 2023 Sep.
Article Zh | MEDLINE | ID: mdl-38639602

Male infertility is a common condition in urology with complex etiology. This article explores the understanding of male infertility through the theories of traditional Classic prescriptions based on the text "Jin Gui Yao Lue". The aim is to provide references for clinical diagnosis and treatment of male infertility.


Infertility, Male , Urology , Male , Humans , Prescriptions , Infertility, Male/etiology , Infertility, Male/therapy , Medicine, Chinese Traditional
17.
Lab Chip ; 22(19): 3668-3675, 2022 09 27.
Article En | MEDLINE | ID: mdl-36062924

Microlasers integrated with biological systems have received tremendous attention for their intense light intensity and narrow linewidth recently, serving as a powerful tool for studying complex dynamics and interactions in scattered biological micro-environments. However, manipulation of microlasers with controllable motions and versatile functions remains elusive. Herein, we introduce the concept of motor-like microlasers formed by magnetic-doped liquid crystal droplets, in which the direction and velocity could be controlled by altering internal magnetic nanoparticles or external magnetic fields. Both translational and rotatory motions of the lasing resonator could be continually changed in real-time. Lasing-encoded motors carrying different functions and lasing wavelengths were also achieved. Finally, we demonstrate the potential of motor-like microlasers by functioning as a localized stimulation emission light source to stimulate or illuminate living cells, providing a novel approach for switching on/off light emissions and subcellular imaging. Laser emitting micromotors offer a facile system for precise manipulation of microlasers in biological fluids, providing new insight into the development of programmable on-chip laser devices and laser-emitting intelligent systems.


Liquid Crystals , Nanoparticles , Lasers , Light , Liquid Crystals/chemistry , Nanoparticles/chemistry
18.
Biosens Bioelectron ; 215: 114594, 2022 Nov 01.
Article En | MEDLINE | ID: mdl-35932553

Rapid and sensitive Escherichia coli (E. coli) detection is important in determining environmental contamination, food contamination, as well as bacterial infection. Conventional methods based on bacterial culture suffer from long testing time (24 h), whereas novel nucleic acid-based and immunolabelling approaches are hindered by complicated operation, the need of complex and costly equipment, and the lack of differentiation of live and dead bacteria. Herein, we propose a chemiluminescence digital microwell array chip based on the hydrolysis of 6-Chloro-4-methylumbelliferyl-ß-D-glucuronide by the ß-D-glucuronidase in E. coli to achieve fast single bacterial fluorescence detection. Taking the advantage of the picoliter microwells, single bacteria are digitally encapsulated in these microwells, thus the accurate quantification of E. coli can be realized by counting the number of positive microwells. We also show that the chemiluminescence digital microwell array chip is not affected by the turbidity of the test samples as well as the temperature. Most importantly, our method can differentiate live and dead bacteria through bacterial proliferation and enzyme expression, which is confirmed by detecting E. coli after pH and chlorination treatment. By comparing with the standard method of plate counting, our method has comparable performance but significantly reduces the testing time from over 24 h-2 h and 4 h for qualitative and quantitative analysis, respectively. In addition, the microfluidic chip is portable and easy to operate without external pump, which is promising as a rapid and on-site platform for single E. coli analysis in water and food monitoring, as well as infection diagnosis.


Biosensing Techniques , Escherichia coli Infections , Escherichia coli , Humans , Luminescence , Microfluidics/methods
19.
Biosensors (Basel) ; 12(7)2022 Jul 21.
Article En | MEDLINE | ID: mdl-35884353

The release of chemicals and microorganisms from various sources, such as industry, agriculture, animal farming, wastewater treatment plants, and flooding, into water systems have caused water pollution in several parts of our world, endangering aquatic ecosystems and individual health. World Health Organization (WHO) has introduced strict standards for the maximum concentration limits for nutrients and chemicals in drinking water, surface water, and groundwater. It is crucial to have rapid, sensitive, and reliable analytical detection systems to monitor the pollution level regularly and meet the standard limit. Electrochemical biosensors are advantageous analytical devices or tools that convert a bio-signal by biorecognition elements into a significant electrical response. Thanks to the micro/nano fabrication techniques, electrochemical biosensors for sensitive, continuous, and real-time detection have attracted increasing attention among researchers and users worldwide. These devices take advantage of easy operation, portability, and rapid response. They can also be miniaturized, have a long-life span and a quick response time, and possess high sensitivity and selectivity and can be considered as portable biosensing assays. They are of special importance due to their great advantages such as affordability, simplicity, portability, and ability to detect at on-site. This review paper is concerned with the basic concepts of electrochemical biosensors and their applications in various water quality monitoring, such as inorganic chemicals, nutrients, microorganisms' pollution, and organic pollutants, especially for developing real-time/online detection systems. The basic concepts of electrochemical biosensors, different surface modification techniques, bio-recognition elements (BRE), detection methods, and specific real-time water quality monitoring applications are reviewed thoroughly in this article.


Biosensing Techniques , Environmental Pollutants , Animals , Biosensing Techniques/methods , Ecosystem , Electrochemical Techniques , Water Quality
20.
ACS Omega ; 7(2): 1819-1826, 2022 Jan 18.
Article En | MEDLINE | ID: mdl-35036821

We report a novel design of chamber-based digital polymerase chain reaction (cdPCR) chip structure. Using a wet etching process and silicon-glass bonding, the chamber size can be adjusted independently of the process and more feasibly in a normal lab. In addition, the structure of the chip is optimized through hydrodynamic computer simulations to eliminate dead space when the sample is injected into the chip. The samples will be distributed to each separated microchambers for an isolated reaction based on Poisson distribution. Due to the difference in expansion coefficients, isolation of the sample in the microchambers by the oil phase on top ensures homogeneity and independence of the sample in the microchambers. The prepared microarray cdPCR chip enables high-throughput and high-sensitivity quantitative measurement of the SARS-CoV-2 virus gene and the mutant lung cancer gene. We applied the chip for the detection of different concentrations of the mix containing the open reading frame 1ab (ORF1ab) gene, the most specific and conservative gene region of the SARS-CoV-2 virus. In addition to this, we also successfully detected the fluorescence of the epidermal growth factor receptor (EGFR) mutant gene in independent microchambers. At a throughput of 46 200 microchambers, solution mixtures containing both genes were successfully tested quantitatively, with a detection limit of 10 copies/µL. Importantly, the chips are individually inexpensive and easy to industrialize. In addition, the microarray can provide a unified solution for other viral sequences, cancer marker assay development, and point-of-care testing (POCT).

...