Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Am J Sports Med ; 51(12): 3154-3162, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37715518

RESUMEN

BACKGROUND: Arthrofibrosis can limit function and return to sport after anterior cruciate ligament (ACL) reconstruction. Previously reported risk factors for developing arthrofibrosis after ACL reconstruction include female sex, age <18 years, time from injury to surgery <28 days, concomitant meniscal repair, prolonged immobilization, and genetic factors. There is a lack of evidence regarding whether race plays a significant role. HYPOTHESIS: The risk of undergoing manipulation under anesthesia (MUA) and/or lysis of adhesions (LOA) after primary ACL reconstruction with bone-patellar tendon-bone (BTB) autograft in female basketball players is higher in African American players than in White players. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: Using a computerized relational database, the authors identified competitive female basketball players who underwent primary ACL reconstruction with BTB autograft by the senior author over a 13-year period. Data previously entered from examinations and surgical findings were reviewed retrospectively. Univariate statistics and multivariable logistic regression were used to assess the relationship between undergoing subsequent MUA and/or LOA and study predictors. RESULTS: A total of 186 knees (114 African American knees and 72 White knees) met inclusion criteria. The overall rate of MUA and/or LOA was 8.6%. Thirteen African American knees (11.4%) and 3 White knees (4.2%) underwent MUA and/or LOA for treatment of arthrofibrosis. No study predictor was found to have a statistically significant relationship with the rate of MUA and/or LOA on univariate analysis. However, when controlling for body mass index and previously described risk factors (age <18 years, time from injury to surgery ≤28 days, and concomitant meniscal repair) in the logistic regression model, the authors found that MUA and/or LOA was more likely in African American (odds ratio, 4.01 [95% CI, 1.01-15.92]; P = .049) than in White female players and in patients who underwent ACL reconstruction within 28 days of injury (odds ratio, 4.01 [95% CI, 1.18-13.57]; P = .026) compared with those with surgery delayed beyond 28 days. CONCLUSION: In female basketball players, the present study found a statistically significantly increased risk for undergoing MUA and/or LOA after primary ACL reconstruction with BTB autograft in African American females compared with White females and in patients who underwent ACL reconstruction within 28 days of injury.


Asunto(s)
Anestesia , Lesiones del Ligamento Cruzado Anterior , Reconstrucción del Ligamento Cruzado Anterior , Baloncesto , Humanos , Femenino , Adolescente , Estudios de Casos y Controles , Estudios Retrospectivos , Lesiones del Ligamento Cruzado Anterior/cirugía , Lesiones del Ligamento Cruzado Anterior/etiología , Reconstrucción del Ligamento Cruzado Anterior/efectos adversos , Adherencias Tisulares
2.
Int J Health Geogr ; 15: 10, 2016 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-26932155

RESUMEN

BACKGROUND: Rapid and accurate diagnosis drives evidence-based care in health. Point-of-care testing (POCT) aids diagnosis by bringing advanced technologies closer to patients. Health small-world networks are constrained by natural connectivity in the interactions between geography of resources and social forces. Using a geographic information system (GIS) we can understand how populations utilize their health networks, visualize their inefficiencies, and compare alternatives. METHODS: This project focuses on cardiac care resource in rural Isaan, Thailand. A health care access analysis was created using ArcGIS Network Analyst 10.1 from data representing aggregated population, roads, health resource facilities, and diagnostic technologies. The analysis quantified cardiac health care access and identified ways to improve it using both widespread and resource-limited strategies. RESULTS: Results indicated that having diagnostic technologies closer to populations streamlines critical care paths. GIS allowed us to compare the effectiveness of the implementation strategies and put into perspective the benefits of adopting rapid POCT within health networks. CONCLUSIONS: Geospatial analyses derive high impact by improving alternative diagnostic placement strategies in limited-resource settings and by revealing deficiencies in health care access pathways. Additionally, the GIS provides a platform for comparing relative costs, assessing benefits, and improving outcomes. This approach can be implemented effectively by health ministries seeking to enhance cardiac care despite limited resources.


Asunto(s)
Sistemas de Información Geográfica/estadística & datos numéricos , Recursos en Salud/estadística & datos numéricos , Accesibilidad a los Servicios de Salud/estadística & datos numéricos , Sistemas de Atención de Punto/estadística & datos numéricos , Humanos , Tailandia/epidemiología
3.
Am J Disaster Med ; 10(2): 121-43, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26312494

RESUMEN

OBJECTIVES: To present a vision where point-of-care testing (POCT) accelerates an Ebola Spatial Care Path™ (SCP) and future molecular diagnostics enable facilitated-access self-testing (FAST POC); to design an alternate care facility (ACF) for the SCP; to innovate an Ebola diagnostic center (DC); and to propel rapid POCT to the frontline to create resilience that stops future outbreaks. DESIGN: PubMed, literature, and web searches. Centers for Disease Control and Prevention (CDC), Food and Drug Administration (FDA), Medicine Without Frontiers, and World Health Organization (WHO) document analyses. Investigations in China, the Philippines, Thailand, and the United States. Review of SE Asia, US, and West Africa isolation-treatment centers. Innovation of a SCP, ACF, and DC suitable for American and other communities. OUTCOMES: The authors designed an ACF and DC to integrate SCP principles for urgent Ebola care. FDA emergency use authorizations for Ebola molecular diagnostics were discovered, but no portable, handheld, or self-contained molecular POC instruments are yet available, although feasible. The WHO initiated design criteria and an acceptance protocol for testing. Financial investment in POCT will downsize Ebola outbreaks. CONCLUSIONS: POCT is facilitating global health. Now, global health problems are elevating POCT to new levels of importance for accelerating diagnosis and evidence-based decision making during disease outbreaks. Authorities concur that rapid diagnosis has potential to stop disease spread. With embedded POCT, strategic SCPs planned by communities fulfill CDC recommendations. POC devices should consolidate multiplex test clusters supporting patients with Ebola in isolation. The ultimate future solution is FAST POC. New technologies offer minimally significant risks. Diagnostic centers in ACFs and transportable formats also will optimize Ebola SCPs.


Asunto(s)
Centros Comunitarios de Salud , Sistemas de Apoyo a Decisiones Clínicas , Brotes de Enfermedades/prevención & control , Fiebre Hemorrágica Ebola/diagnóstico , Fiebre Hemorrágica Ebola/terapia , Sistemas de Atención de Punto , África Occidental , Vías Clínicas , Fiebre Hemorrágica Ebola/prevención & control , Humanos , Aislamiento de Pacientes , Salud Pública , Resiliencia Psicológica , Estados Unidos
4.
J Diabetes Sci Technol ; 8(1): 83-88, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24876542

RESUMEN

The objective was to assess the effects of short-term (≤1 hour) static high temperature and humidity stresses on the performance of point-of-care (POC) glucose test strips and meters. Glucose meters are used by medical responders and patients in a variety of settings including hospitals, clinics, homes, and the field. Reagent test strips and instruments are potentially exposed to austere environmental conditions. Glucose test strips and meters were exposed to a mean relative humidity of 83.0% (SD = 8.0%) and temperature of 42°C (107.6°F, SD = 3.2) in a Tenney BTRC environmental chamber. Stressed and unstressed glucose reagent strips and meters were tested with spiked blood samples (n = 40 measurements per time point for each of 4 trials) after 15, 30, 45, and 60 minutes of exposure. Wilcoxon's signed rank test was applied to compare measurements test strip and meter measurements to isolate and characterize the magnitude of meter versus test strip effects individually. Stressed POC meters and test strips produced elevated glucose results, with stressed meter bias as high as 20 mg/dL (17.7% error), and stressed test strip bias as high as 13 mg/dL (12.2% error). The aggregate stress effect on meter and test strips yielded a positive bias as high as 33 mg/dL (30.1% error) after 15 minutes of exposure. Short-term exposure (15 minutes) to high temperature and humidity can significantly affect the performance of POC glucose test strips and meters, with measurement biases that potentially affect clinical decision making and patient safety.

5.
Disaster Med Public Health Prep ; 8(1): 51-7, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24588956

RESUMEN

OBJECTIVE: Efficient emergency and disaster response is challenged by environmental conditions exceeding test reagent storage and operating specifications. We assessed the effectiveness of vial and foil packaging in preserving point-of-care (POC) glucose and lactate test strip performance in humid conditions. METHODS: Glucose and lactate test strips in both packaging were exposed to mean relative humidity of 97.0 ± 1.1% in an environmental chamber for up to 168 hours. At defined time points, stressed strips were removed and tested in pairs with unstressed strips using whole blood samples spiked to glucose concentrations of 60, 100, and 250 mg/dL (n = 20 paired measurements per level). A Wilcoxon signed rank test was used to compare stressed and unstressed test strip measurements. RESULTS: Stressed glucose and lactate test strip measurements differed significantly from unstressed strips, and were inconsistent between experimental trials. Median glucose paired difference was as high as 12.5 mg/dL at the high glucose test concentration. Median lactate bias was -0.2 mmol/L. Stressed strips from vial (3) and foil (7) packaging failed to produce results. CONCLUSIONS: Both packaging designs appeared to protect glucose and lactate test strips for at least 1 week of high humidity stress. Documented strip failures revealed the need for improved manufacturing process.


Asunto(s)
Glucemia , Humedad/efectos adversos , Ácido Láctico/sangre , Sistemas de Atención de Punto , Tiras Reactivas/química , Planificación en Desastres , Desastres
6.
Prehosp Disaster Med ; 29(1): 4-12, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24382031

RESUMEN

INTRODUCTION: During disasters and complex emergencies, environmental conditions can adversely affect the performance of point-of-care (POC) testing. Knowledge of these conditions can help device developers and operators understand the significance of temperature and humidity limits necessary for use of POC devices. First responders will benefit from improved performance for on-site decision making. OBJECTIVE: To create dynamic temperature and humidity profiles that can be used to assess the environmental robustness of POC devices, reagents, and other resources (eg, drugs), and thereby, to improve preparedness. METHODS: Surface temperature and humidity data from the National Climatic Data Center (Asheville, North Carolina USA) was obtained, median hourly temperature and humidity were calculated, and then mathematically stretched profiles were created to include extreme highs and lows. Profiles were created for: (1) Banda Aceh, Indonesia at the time of the 2004 Tsunami; (2) New Orleans, Louisiana USA just before and after Hurricane Katrina made landfall in 2005; (3) Springfield, Massachusetts USA for an ambulance call during the month of January 2009; (4) Port-au-Prince, Haiti following the 2010 earthquake; (5) Sendai, Japan for the March 2011 earthquake and tsunami with comparison to the colder month of January 2011; (6) New York, New York USA after Hurricane Sandy made landfall in 2012; and (7) a 24-hour rescue from Hawaii USA to the Marshall Islands. Profiles were validated by randomly selecting 10 days and determining if (1) temperature and humidity points fell inside and (2) daily variations were encompassed. Mean kinetic temperatures (MKT) were also assessed for each profile. RESULTS: Profiles accurately modeled conditions during emergency and disaster events and enclosed 100% of maximum and minimum temperature and humidity points. Daily variations also were represented well with 88.6% (62/70) of temperature readings and 71.1% (54/70) of relative humidity readings falling within diurnal patterns. Days not represented well primarily had continuously high humidity. Mean kinetic temperature was useful for severity ranking. CONCLUSIONS: Simulating temperature and humidity conditions clearly reveals operational challenges encountered during disasters and emergencies. Understanding of environmental stresses and MKT leads to insights regarding operational robustness necessary for safe and accurate use of POC devices and reagents. Rescue personnel should understand these principles before performing POC testing in adverse environments.


Asunto(s)
Técnicas de Laboratorio Clínico/instrumentación , Medicina de Desastres/instrumentación , Planificación en Desastres , Servicios Médicos de Urgencia/normas , Humedad , Sistemas de Atención de Punto/normas , Temperatura , Tormentas Ciclónicas , Toma de Decisiones , Terremotos , Falla de Equipo , Haití , Hawaii , Humanos , Indonesia , Japón , Massachusetts , Nueva Orleans , Ciudad de Nueva York , Tsunamis
7.
Clin Chem Lab Med ; 52(3): 325-35, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24114917

RESUMEN

Strategic integration of point-of-care (POC) diagnostic tools during crisis response can accelerate triage and improve management of victims. Timely differential diagnosis is essential wherever care is provided to rule out or rule in disease, expedite life-saving treatment, and improve utilization of limited resources. POC testing needs to be accurate in any environment in which it is used. Devices are exposed to potentially adverse storage and operating conditions, such as high/low temperature and humidity during emergencies and field rescues. Therefore, characterizing environmental conditions allows technology developers, operators, and responders to understand the broad operational requirements of test reagents, instruments, and equipment in order to improve the quality and delivery of care in complex emergencies, disasters, and austere environmental settings. This review aims to describe the effects of environmental stress on POC testing performance and its impact on decision-making, to describe how to study the effects, and to summarize ways to mitigate the effects of environmental stresses through good laboratory practice, development of robust reagents, and novel thermal packaging solutions.


Asunto(s)
Ambiente , Equipos y Suministros , Personal de Salud , Sistemas de Atención de Punto , Desastres , Humanos , Indicadores y Reactivos
8.
Am J Disaster Med ; 8(3): 181-204, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24352993

RESUMEN

OBJECTIVE: To describe, innovate, recommend, and foster the implementation of point-of-care (POC) testing in disaster caches to enhance crisis standards of care and to improve triage, diagnosis, monitoring, treatment, and management of victims and volunteers in complex emergencies and disasters. DESIGN AND SETTINGS: The authors compared POC testing in United States disaster caches to commercially available POC testing to enhance the caches and to reflect current state-of-the-art diagnostic capabilities. The authors also provided recommendations based on literature review and knowledge from newly developed POC technologies from the UC Davis Point-of-Care Technologies Center. RESULTS: Presently, US POC testing caches comprise chemistry/electrolytes, pregnancy, hemoglobin, cardiac biomarkers, hematology, fecal occult blood, drugs of abuse, liver function, blood gases, and limited infectious diseases. Deficiencies with existing POC tests for cardiac biomarkers, hematology, and infectious diseases should be eliminated. POC resources can be customized for pandemics, complex emergencies, or disasters based on geographic location and potential infectious diseases. Additionally, a new thermally stabilized container can help alleviate environmental stresses that reduce test quality. CONCLUSIONS: Innovations in POC technologies can improve response preparedness with enhanced diagnostic capabilities. Several innovations, such as the i-STAT® Wireless, OraQuick ADVANCE® HIV-1/2, VereTrop™ Lab-on-a-Chip, and new compact hematology analyzers will improve test clusters that facilitate evidence-based decision making and crisis standards of care during US national disaster responses. Additionally, strategic resources and operator training should be globally harmonized to improve the efficiency of international responses.


Asunto(s)
Técnicas de Laboratorio Clínico/instrumentación , Difusión de Innovaciones , Medicina de Desastres/organización & administración , Desastres , Invenciones , Sistemas de Atención de Punto , Humanos , Triaje/organización & administración , Estados Unidos
9.
Am J Disaster Med ; 8(3): 205-12, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24352994

RESUMEN

OBJECTIVE: To characterize the effects of environmental stress on point-of-care (POC) cardiac biomarker testing during a simulated rescue. DESIGN: Multiplex test cassettes for cardiac troponin I (cTnI), brain natriuretic peptide (BNP), CK-MB, myoglobin, and D-dimer were exposed to environmental stresses simulating a 24-hour rescue from Hawaii to the Marshall Islands and back. We used Tenney environmental chambers (T2RC and BTRC) to simulate flight conditions (20°C, 10 percent relative humidity) and ground conditions (22.3-33.9°C, 73-77 percent). We obtained paired measurements using stressed versus control (room temperature) cassettes at seven time points (T1-7 with T1,2,6,7 during flight and T3-5 on ground). We analyzed paired differences (stressed minus control) with Wilcoxon signed rank test. We assessed the impact on decision-making at clinical thresholds. RESULTS: cTnI results from stressed test cassettes (n = 10) at T4 (p < 0.05), T5 (p < 0.01), and T7 (p < 0.05) differed significantly from control, when testing samples with median cTnI concentration of 90 ng/L. During the ground rescue, 36.7 percent (11/30) of cTnI measurements from stressed cassettes generated significantly lowered results. At T5, 20 percent (2/10) of cTnI results were highly discrepant-stressed cassettes reported normal results, when control results were >100 ng/L. With sample median concentration of 108 pg/mL, BNP results from stressed test cassettes differed significantly from controls (p < 0.05). CONCLUSION: Despite modest, short-term temperature elevation, environmental stresses led to erroneous results. False negative cTnI and BNP results potentially could miss acute myocardial infarction and congestive heart failure, confounded treatment, and increased mortality and morbidity. Therefore, rescuers should protect POC reagents from temperature extremes.


Asunto(s)
Análisis Químico de la Sangre , Servicios Médicos de Urgencia , Ambiente , Pruebas de Función Cardíaca , Sistemas de Atención de Punto , Trabajo de Rescate , Biomarcadores , Forma MB de la Creatina-Quinasa , Productos de Degradación de Fibrina-Fibrinógeno , Humanos , Mioglobina , Péptido Natriurético Encefálico , Estrés Fisiológico , Troponina I
10.
Disaster Med Public Health Prep ; 6(3): 232-40, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23077265

RESUMEN

OBJECTIVE: To characterize the performance of glucose meter test strips using simulated dynamic temperature and humidity disaster conditions. METHODS: Glucose oxidase- and glucose dehydrogenase-based test strips were dynamically stressed for up to 680 hours using an environmental chamber to simulate conditions during Hurricane Katrina. Paired measurements vs control were obtained using 3 aqueous reagent levels for GMS1 and 2 for GMS2. RESULTS: Stress affected the performance of GMS1 at level 1 (P < .01); and GMS2 at both levels (P < .001), lowering GMS1 results but elevating GMS2 results. Glucose median-paired differences were elevated at both levels on GMS2 after 72 hours. Median-paired differences (stress minus control) were as much as -10 mg/dL (range, -65 to 33) at level 3 with GMS1, with errors as large as 21.9%. Glucose median-paired differences were as high as 5 mg/dL (range, -1 to 10) for level 1 on GMS2, with absolute errors up to 24.4%. CONCLUSIONS: The duration of dynamic stress affected the performance of both GMS1 and GMS2 glucose test strips. Therefore, proper monitoring, handling, and storage of point-of-care (POC) reagents are needed to ensure their integrity and quality of actionable results, thereby minimizing treatment errors in emergency and disaster settings.


Asunto(s)
Glucemia/análisis , Tormentas Ciclónicas , Desastres , Humedad , Sistemas de Atención de Punto/normas , Tiras Reactivas/normas , Temperatura , Falla de Equipo , Humanos , Errores Médicos
11.
Environ Sci Technol ; 36(20): 4326-33, 2002 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-12387405

RESUMEN

The effect of precipitates on the reactivity of iron metal (Fe0) with 1,1,1-trichloroethane (TCA) was studied in batch systems designed to model groundwaters that contain dissolved carbonate species (i.e., C(IV)). At representative concentrations for high-C(IV) groundwaters (approximately 10(-2) M), the pH in batch reactors containing Fe0 was effectively buffered until most of the aqueous C(IV) precipitated. The precipitate was mainly FeCO3 (siderite) but may also have included some carbonate green rust. Exposure of the Fe0 to dissolved C(IV) accelerated reduction of TCA, and the products formed under these conditions consisted mainly of ethane and ethene, with minor amounts of several butenes. The kinetics of TCA reduction were first-order when C(IV)-enhanced corrosion predominated but showed mixed-order kinetics (zero- and first-order) in experiments performed with passivated Fe0 (i.e., before the onset of pitting corrosion and after repassivation by precipitation of FeCO3). All these data were described by fitting a Michaelis-Menten-type kinetic model and approximating the first-order rate constant as the ratio of the maximum reaction rate (Vm) and the concentration of TCA at half of the maximum rate (K(1/2)). The decrease in Vm/K(1/2) with increasing C(IV) exposure time was fit to a heuristic model assuming proportionality between changes in TCA reduction rate and changes in surface coverage with FeCO3.


Asunto(s)
Hierro/química , Modelos Teóricos , Solventes/química , Tricloroetanos/química , Contaminantes del Agua/análisis , Precipitación Química , Cinética , Purificación del Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA