Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Chromatogr A ; 1730: 465058, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-38876077

RESUMEN

This study investigated the influence of pH on the retention of solutes using a mixed-mode column with carboxyl (-COOH) groups acting as weak cation exchanger bonded to the terminal of C18 ligands (C18-WCX column) and a traditional reversed-phase C18 column. First, a model based on electrostatic theory was derived and successfully used to predict the retention of charged solutes (charged, and ionizable) as a function of mobile phase pH on a C18-WCX column. While the Horváth model predicts the pH-dependent retention of ionizable solutes in reversed-phase liquid chromatography (RPLC) solely based on solute ionization, the developed model incorporates the concept of surface potential generated on the surface of the stationary phase and its variation with pH. To comprehensively understand the adsorption process, adsorption isotherms for these solutes were individually acquired on the C18-WCX and reversed-phase C18 columns. The adsorption isotherms followed the Langmuir model for the uncharged solute and the electrostatically modified Langmuir model for charged solutes. The elution profiles for the single components were calculated from these isotherms using the equilibrium dispersion column model and were found to be in close agreement with the experimental elution profiles. To enable modelling of two-component cases involving charged solute(s), a competitive adsorption isotherm model based on electrostatic theory was derived. This model was later successfully used to calculate the elution profiles of two components for scenarios involving (a) a C18 Column: two charged solutes, (b) a C18 Column: one charged and one uncharged solute, and (c) a C18-WCX Column: two charged solutes. The strong alignment between the experimental and calculated elution profiles in all three scenarios validated the developed competitive adsorption model.


Asunto(s)
Cromatografía de Fase Inversa , Electricidad Estática , Cromatografía de Fase Inversa/métodos , Adsorción , Concentración de Iones de Hidrógeno , Modelos Químicos
2.
J Pers Med ; 11(2)2021 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-33513899

RESUMEN

Primary hyperoxalurias (PHs) are a group of inherited alterations of the hepatic glyoxylate metabolism. PHs classification based on gene mutations parallel a variety of enzymatic defects, and all involve the harmful accumulation of calcium oxalate crystals that produce systemic damage. These geographically widespread rare diseases have a deep impact in the life quality of the patients. Until recently, treatments were limited to palliative measures and kidney/liver transplants in the most severe forms. Efforts made to develop pharmacological treatments succeeded with the biotechnological agent lumasiran, a siRNA product against glycolate oxidase, which has become the first effective therapy to treat PH1. However, small molecule drugs have classically been preferred since they benefit from experience and have better pharmacological properties. The development of small molecule inhibitors designed against key enzymes of glyoxylate metabolism is on the focus of research. Enzyme inhibitors are successful and widely used in several diseases and their pharmacokinetic advantages are well known. In PHs, effective enzymatic targets have been determined and characterized for drug design and interesting inhibitory activities have been achieved both in vitro and in vivo. This review describes the most recent advances towards the development of small molecule enzyme inhibitors in the treatment of PHs, introducing the multi-target approach as a more effective and safe therapeutic option.

3.
J Chromatogr A ; 1241: 60-8, 2012 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-22552201

RESUMEN

A chiral HPLC method using four macrocyclic antibiotic chiral stationary phases (CSPs) has been investigated for determination of the enantiomeric purity of fourteen new chiral derivatives of xanthones (CDXs). The separations were performed with the CSPs Chirobiotic T, Chirobiotic TAG, Chirobiotic V and Chirobiotic R under multimodal elution conditions (normal-phase, reversed-phase and polar ionic mode). The analyses were performed at room temperature in isocratic mode and UV and CD detection at a wavelength of 254 nm. The best enantioselectivity and resolution were achieved on Chirobiotic R and Chirobiotic T CSPs, under normal elution conditions, with R(S) ranging from 1.25 to 2.50 and from 0.78 to 2.06, respectively. The optimized chromatographic conditions allowed the determination of the enantiomeric ratio of eight CDXs, always higher than 99%. In order to better understand the chromatographic behavior at a molecular level, and the structural features associated with the chiral recognition mechanism, computational studies by molecular docking were carried out using VDock. These studies shed light on the mechanisms involved in the enantioseparation for this important class of chiral compounds.


Asunto(s)
Antibacterianos/química , Cromatografía Líquida de Alta Presión/instrumentación , Compuestos Macrocíclicos/química , Xantonas/química , Cromatografía Líquida de Alta Presión/métodos , Glicopéptidos/química , Modelos Moleculares , Estereoisomerismo , Termodinámica , Xantonas/aislamiento & purificación
4.
ScientificWorldJournal ; 6: 1542-54, 2006 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-17160340

RESUMEN

Homology modeling is a computational methodology to assign a 3-D structure to a target protein when experimental data are not available. The methodology uses another protein with a known structure that shares some sequence identity with the target as a template. The crudest approach is to thread the target protein backbone atoms over the backbone atoms of the template protein, but necessary refinement methods are needed to produce realistic models. In this mini-review anchored within the scope of drug design, we show the validity of using homology models of proteins in the discovery of binders for potential therapeutic targets. We also report several different approaches to homology model refinement, going from very simple to the most elaborate. Results show that refinement approaches are system dependent and that more elaborate methodologies do not always correlate with better performances from built homology models.


Asunto(s)
Biología Computacional/métodos , Diseño de Fármacos , Modelos Químicos , Homología Estructural de Proteína , Relación Estructura-Actividad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA