Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMJ Open ; 14(3): e077770, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38448059

RESUMEN

INTRODUCTION: Lung transplantation (LTx) aims at improving survival and quality of life for patients with end-stage lung diseases. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is used as intraoperative support for LTx, despite no precise guidelines for its initiation. We aim to evaluate two strategies of VA-ECMO initiation in the perioperative period in patients with obstructive or restrictive lung disease requiring bilateral LTx. In the control 'on-demand' arm, high haemodynamic and respiratory needs will dictate VA-ECMO initiation; in the experimental 'systematic' arm, VA-ECMO will be pre-emptively initiated. We hypothesise a 'systematic' strategy will increase the number of ventilatory-free days at day 28. METHODS AND ANALYSIS: We designed a multicentre randomised controlled trial in parallel groups. Adult patients with obstructive or restrictive lung disease requiring bilateral LTx, without a formal indication for pre-emptive VA-ECMO before LTx, will be included. Patients with preoperative pulmonary hypertension with haemodynamic collapse, ECMO as a bridge to transplantation, severe hypoxaemia or hypercarbia will be secondarily excluded. In the systematic group, VA-ECMO will be systematically implanted before the first pulmonary artery cross-clamp. In the on-demand group, VA-ECMO will be implanted intraoperatively if haemodynamic or respiratory indices meet preplanned criteria. Non-inclusion, secondary exclusion and VA-ECMO initiation criteria were validated by a Delphi process among investigators. Postoperative weaning of ECMO and mechanical ventilation will be managed according to best practice guidelines. The number of ventilator-free days at 28 days (primary endpoint) will be compared between the two groups in the intention-to-treat population. Secondary endpoints encompass organ failure occurrence, day 28, day 90 and year 1 vital status, and adverse events. ETHICS AND DISSEMINATION: The sponsor is the Assistance Publique-Hôpitaux de Paris. The ECMOToP protocol version 2.1 was approved by Comité de Protection des Personnes Ile de France VIII. Results will be published in international peer-reviewed medical journals. TRIAL REGISTRATION NUMBER: NCT05664204.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Hipertensión Pulmonar , Trasplante de Pulmón , Adulto , Humanos , Calidad de Vida , Morbilidad , Hipertensión Pulmonar/terapia , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Multicéntricos como Asunto
4.
Thromb Res ; 233: 203-211, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38128338

RESUMEN

INTRODUCTION: Lung transplantation is associated with high proportion of transfusion. Monitoring of coagulopathy using viscoelastic tests could aid in the perioperative management of bleeding. The aim of the study was to assess the predictive cut-off values for thrombocytopenia and hypofibrinogenemia using the new thromboelastography analyzer, ClotPro. METHODS: We retrospectively enrolled 65 patients who underwent lung transplantation and were sampled for both viscoelastic assays and conventional coagulation assays simultaneously during the procedure. We characterized the correlation between the EX-test (extrinsic pathway) and platelet count as well as between the FIB-test (extrinsic pathway after platelet inhibition) and fibrinogen concentration. Then, we used ROC curve analysis to determine the optimal EX-test and FIB-test values for predicting thrombocytopenia and hypofibrinogenemia. RESULTS: All the amplitude values of the EX-test (A5, A10, A20, MCF) showed correlation with platelets count (Spearman's rank correlation coefficient ranging from 0.75 to 0.77, all p < 0.0001). We also observed a strong correlation between the amplitude values of the FIB-test (A5, A10, A20 and MCF) and the fibrinogen concentration (Spearman's rank correlation coefficient ranging from 0.68 to 0.71, all p < 0.0001). The AUCs of the EX-test values for thrombocytopenia <100 G/L and <80 G/L ranged from 0.80 to 0.93. Similarly, the AUCs of the FIB-test values for hypofibrinogenemia <1.5 g/L and <2 g/L ranged from 0.74 to 0.83. These results indicate that only the five-minute parameter of thromboelastometry is sufficient for detecting thrombocytopenia and hypofibrinogenemia in patients undergoing lung transplantation. The proposed cut off values for the EX-test to predict thrombocytopenia <80 G/L showed high sensitivity (>86 %), high specificity (>89 %) and high negative predictive value (>95 %). FIB-test cut off values predictive of fibrinogen below 1.5 g/L showed sensitivity (>78 %), specificity (>55 %) and negative predictive value (>88 %). CONCLUSIONS: Our study provided preliminary results that are useful for developing a ClotPro-based algorithm to guide transfusion in lung transplantation. Future interventional studies will be necessary to validate these cut-off values of ClotPro for guiding transfusion.


Asunto(s)
Afibrinogenemia , Trasplante de Pulmón , Trombocitopenia , Trombosis , Humanos , Tromboelastografía/métodos , Afibrinogenemia/diagnóstico , Afibrinogenemia/complicaciones , Estudios Retrospectivos , Trombocitopenia/diagnóstico , Trombocitopenia/etiología , Fibrinógeno/metabolismo , Trombosis/complicaciones , Trasplante de Pulmón/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA