Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 8 de 8
1.
Sci Rep ; 14(1): 2721, 2024 02 01.
Article En | MEDLINE | ID: mdl-38302574

Optical coherence tomography angiography (OCTA) enables three-dimensional reconstruction of the functional blood vessels in the retina. Therefore, it enables the quantification of 3D retinal vessel parameters such as surface area and vessel volume. In spite of the widespread use of OCTA, no representative volume-rendered vessel volume (VV) data are published to date. In this study, OCTA 3 × 3 mm macular cubes were processed with volume-rendering techniques to measure VV in 203 eyes from 107 healthy volunteers. Generalized linear models (GLM) were constructed to assess the impact of age, gender, visual acuity (VA), spherical equivalent (SE), and axial length (AL) on VV. Overall mean VV was 0.23 ± 0.05mm3. Age and axial length showed a negative correlation with VV. However, GLM model analysis found that AL exerted the most pronounced influence on VV. No statistically significant associations were identified between gender or between left and right eyes. This is the first study to assess 3D OCTA VV and its naturally occurring variations in a large series of healthy subjects. It offers novel insights into the characterization of normal retinal vascular anatomy in healthy individuals, contributing to a valuable reference for future research in this field.


Retinal Vessels , Tomography, Optical Coherence , Humans , Fluorescein Angiography/methods , Tomography, Optical Coherence/methods , Retinal Vessels/diagnostic imaging , Retina/diagnostic imaging , Visual Acuity
2.
Front Oncol ; 13: 1217714, 2023.
Article En | MEDLINE | ID: mdl-37637047

Background: Plasma cell leukemia (PCL) is an aggressive and rare form of plasma cell dyscrasia characterized by peripheral blood expression, poor prognosis, and high relapse rates. Extramedullary plasmacytomas are common in this entity and can affect various organs and soft tissues. Chimeric antigen receptor-T-cell (CAR-T) therapy is a novel immunotherapy for hematological malignancies with promising results. However, it is not indicated for PCL, and experience in this condition is limited. This case is a rare presentation of bilateral orbital plasmacytomas after CAR-T therapy in a patient with PCL history. Case presentation: We present the case of a 51-year-old female patient with a history of previous primary PCL treated with CAR-T therapy achieving complete response and without evidence of systemic progression. Six months after the treatment, she developed subacute proptosis and ptosis on the left eye.An orbital CT scan was performed and showed an orbital tumor in both eyes. A surgical biopsy with histological examination revealed plasma cells, consistent with a plasmacytoma. PET-CT and MRI confirmed the presence of tumors in both orbits. The patient was treated with dexamethasone and chemotherapy along with palliative radiation therapy to the left orbit which had a good response. Conclusion: Orbital involvement in multiple myeloma and PCL is rare, with plasmacytomas being more common in other parts of the body. In this report, we present a case of a patient with PCL history, treated with multiple therapeutic lines including CAR-T therapy, who presented bilateral orbital plasmacytomas as the first sign of extramedullary progression after the treatment. This case should be considered by specialist to be aware that the orbits are a possible location of extramedullary progression.

3.
Ophthalmol Sci ; 3(2): 100259, 2023 Jun.
Article En | MEDLINE | ID: mdl-36578904

Purpose: To evaluate the diagnostic accuracy of machine learning (ML) techniques applied to radiomic features extracted from OCT and OCT angiography (OCTA) images for diabetes mellitus (DM), diabetic retinopathy (DR), and referable DR (R-DR) diagnosis. Design: Cross-sectional analysis of a retinal image dataset from a previous prospective OCTA study (ClinicalTrials.govNCT03422965). Participants: Patients with type 1 DM and controls included in the progenitor study. Methods: Radiomic features were extracted from fundus retinographies, OCT, and OCTA images in each study eye. Logistic regression, linear discriminant analysis, support vector classifier (SVC)-linear, SVC-radial basis function, and random forest models were created to evaluate their diagnostic accuracy for DM, DR, and R-DR diagnosis in all image types. Main Outcome Measures: Area under the receiver operating characteristic curve (AUC) mean and standard deviation for each ML model and each individual and combined image types. Results: A dataset of 726 eyes (439 individuals) were included. For DM diagnosis, the greatest AUC was observed for OCT (0.82, 0.03). For DR detection, the greatest AUC was observed for OCTA (0.77, 0.03), especially in the 3 × 3 mm superficial capillary plexus OCTA scan (0.76, 0.04). For R-DR diagnosis, the greatest AUC was observed for OCTA (0.87, 0.12) and the deep capillary plexus OCTA scan (0.86, 0.08). The addition of clinical variables (age, sex, etc.) improved most models AUC for DM, DR and R-DR diagnosis. The performance of the models was similar in unilateral and bilateral eyes image datasets. Conclusions: Radiomics extracted from OCT and OCTA images allow identification of patients with DM, DR, and R-DR using standard ML classifiers. OCT was the best test for DM diagnosis, OCTA for DR and R-DR diagnosis and the addition of clinical variables improved most models. This pioneer study demonstrates that radiomics-based ML techniques applied to OCT and OCTA images may be an option for DR screening in patients with type 1 DM. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

4.
Sci Rep ; 12(1): 3695, 2022 03 07.
Article En | MEDLINE | ID: mdl-35256644

Optical coherence tomography angiography (OCTA) enables three-dimensional, high-resolution, depth-resolved flow to be distinguished from non-vessel tissue signals in the retina. Thus, it enables the quantification of the 3D surface area of the retinal vessel signal. Despite the widespread use of OCTA, no representative spatially rendered reference vessel surface area data are published. In this study, the OCTA vessel surface areas in 203 eyes of 107 healthy participants were measured in the 3D domain. A Generalized Linear Model (GLM) model analysis was performed to investigate the effects of sex, age, spherical equivalent, axial length, and visual acuity on the OCTA vessel surface area. The mean overall vessel surface area was 54.53 mm2 (range from 27.03 to 88.7 mm2). OCTA vessel surface area was slightly negatively correlated with age. However, the GLM model analysis identified axial length as having the strongest effect on OCTA vessel surface area. No significant correlations were found for sex or between left and right eyes. This is the first study to characterize three-dimensional vascular parameters in a population based on OCTA with respect to the vessel surface area.


Retinal Vessels , Tomography, Optical Coherence , Fluorescein Angiography/methods , Fundus Oculi , Humans , Retina , Retinal Vessels/diagnostic imaging , Tomography, Optical Coherence/methods , Visual Acuity
5.
Am J Ophthalmol Case Rep ; 25: 101332, 2022 Mar.
Article En | MEDLINE | ID: mdl-35146202

PURPOSE: To report a case of wound neovascularization (Swan syndrome) one year after trabeculectomy favorably treated with two intravitreal ranibizumab injections. OBSERVATIONS: A 79-year-old woman under coumadin treatment for atrial fibrillation experienced relapsing decreased vision in her left eye due to vitreous hemorrhage. She had had a past history of ocular hypertension corneal decompensation after phacoemulsification that required a Descemet Membrane Endothelial Keratoplasty and a subsequent trabeculectomy. After clearance of the hemorrhage, examination showed neovascularization not in the retina but surrounding the sclerostomy wound of the trabeculectomy, being diagnosed as a Swan syndrome. After two intravitreal injections of ranibizumab, gonioscopy showed complete resolution of the new vessels. No further recurrences have been reported and IOP has remained controlled without glaucomatous changes 7 months after the last injection. Clinical features and patient characteristics are described. CONCLUSION AND IMPORTANCE: Anti-vascular endothelial growth factor intravitreal injections may be a good and safe alternative to manage vitreous hemorrhage secondary to wound neovascularization of the trabeculectomy site.

6.
Eur J Ophthalmol ; 32(6): 3363-3371, 2022 Nov.
Article En | MEDLINE | ID: mdl-35098756

PURPOSE: To assess agreement between corneal aberration measurements made through swept-source optical coherence tomography using a new anterior segment imaging device (Anterion) and a Scheimpflug imaging device (Pentacam HR) in healthy subjects. METHODS: Cross-sectional study. In 50 eyes of 50 healthy subjects, 14 aberration parameters (7 across the anterior corneal surface and 7 across the total surface) were measured in 4 mm and 6 mm optic zones using each device: oblique trefoil (Z3_-3), vertical coma (Z3_-1), horizontal coma (Z3_1), horizontal trefoil (Z3_3), spherical aberration (Z4_0), root mean square (RMS) lower order aberrations (LOA) and RMS higher order aberrations (HOA). Data for the two devices were compared through intraclass correlation coefficients (ICC), paired t tests, limits of agreement (LoA) and Bland Altman plots. RESULTS: Vertical coma was the only corneal aberration parameter that consistently showed excellent agreement (ICC > 0.8, mean difference -0.019, LoA -0.165 to 0.126). Good agreement (ICC = 0.75) between the devices was observed for RMS HOA, but this was slightly worse in the 6 mm optical zone (ICC = 0.667 for anterior RMS HOA). No over- or underestimation trend by one or other device was noted. Agreement was poor to moderate for the rest of the corneal parameters (ICC 0.2 to 0.7). CONCLUSION: Despite good agreement overall for vertical coma and RMS HOA values, agreement for the remaining corneal aberration measurements was poor to moderate. As mean differences in our sample were overall small, in normal eyes these devices could be clinically judged as interchangeable.


Coma , Tomography, Optical Coherence , Cornea/diagnostic imaging , Corneal Topography/methods , Cross-Sectional Studies , Humans , Reproducibility of Results , Tomography, Optical Coherence/methods
7.
J Clin Med ; 10(24)2021 Dec 10.
Article En | MEDLINE | ID: mdl-34945085

This study examines agreement between the devices Anterion® and Pentacam HR® used for corneal and pupil measurements in healthy eyes. The parameters compared between the two devices were: anterior Km (D), anterior K2 (D), anterior K1 (D), anterior K1 axis (°), anterior astigmatism (D), anterior K max (D), posterior Km (D), posterior K2 (D), posterior K1 (D), posterior K1 axis (°), posterior astigmatism (D), CCT (µm), thinnest point thickness (µm), thinnest point X-coordinate (mm), thinnest point Y-coordinate (mm), pupil diameter (mm), pupil center-corneal vertex distance (mm) (angle kappa), pupil centroid angle (°), pupil centroid X-coordinate (mm), and pupil centroid Y-coordinate (mm). The Student's t test for independent samples identified significant differences (p < 0.005) between devices for the measurements anterior and posterior flat K axis, posterior flat K, steep K, and mean K. For these last three measurements, although significant, none of the differences were clinically relevant. Corneal power and thickness measurements except Kf axis showed excellent agreement between Anterion and Pentacam. In a clinical setting we would not recommend the interchangeable use of Pentacam and Anterion for measurement of pupil parameters.

8.
Am J Dermatopathol ; 43(12): e263-e266, 2021 Dec 01.
Article En | MEDLINE | ID: mdl-34291749

ABSTRACT: Perivascular epithelioid cell tumors (PEComas) are infrequent mesenchymal neoplasms that have particular histological and immunohistochemical features. Only a few cases have been described in the eye and orbit. This report presents a 28-year-old man who consulted for a painless left orbital mass. With the presumptive diagnosis of cavernous hemangioma, a surgical excisional biopsy was performed. Histopathological examination showed a well-delimited tumor composed of epithelioid cells with an eosinophilic cytoplasm and oval nucleus. The tumor cells stained diffusely for HMB-45 and transcription factor E3 (TFE3) and were focally positive for actin. There was no reactivity to S100 or desmin. Genetic testing revealed a TFE3 rearrangement. Based on these results, an extremely rare orbital TFE3-rearranged PEComa was diagnosed. Although no recurrence was seen at last follow-up, a review of the literature shows experience is limited regarding orbital PEComas and their malignant potential. Further research is needed to establish management guidelines, their association with the tuberous sclerosis complex, and the role of genetic mutations such as TFE3 rearrangement.


Basic Helix-Loop-Helix Leucine Zipper Transcription Factors/genetics , Orbital Neoplasms/genetics , Orbital Neoplasms/pathology , Perivascular Epithelioid Cell Neoplasms/genetics , Perivascular Epithelioid Cell Neoplasms/pathology , Adult , Gene Rearrangement/genetics , Humans , Male
...