Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Más filtros










Intervalo de año de publicación
2.
PLoS One ; 17(10): e0275632, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36227865

RESUMEN

BACKGROUND: Resveratrol may improve organ dysfunction after experimental hemorrhagic or septic shock, and some of these effects appear to be mediated by estrogen receptors. However, the influence of resveratrol on liver function and hepatic microcirculation after hemorrhagic shock is unknown, and a presumed mediation via estrogen receptors has not been investigated in this context. METHODS: Male Sprague-Dawley rats (200-300g, n = 14/group) underwent hemorrhagic shock for 90 min (MAP 35±5 mmHg) and were resuscitated with shed blood and Ringer's solution. Animals were treated intravenously with vehicle (1% EtOH), resveratrol (0.2 mg/kg), the unselective estrogen receptor antagonist ICI 182,780 (0.05 mg/kg) or resveratrol + ICI 182,780 prior to retransfusion. Sham-operated animals did not undergo hemorrhage but were treated likewise. After 2 hours of reperfusion, liver function was assessed either by plasma disappearance rate of indocyanine green (PDRICG) or evaluation of hepatic perfusion and hepatic integrity by intravital microscopy, serum enzyme as well as cytokine levels. RESULTS: Compared to vehicle controls, administration of resveratrol significantly improved PDRICG, hepatic perfusion index and hepatic integrity after hemorrhagic shock. The co-administration of ICI 182,780 completely abolished the protective effect only with regard to liver function. CONCLUSIONS: This study shows that resveratrol may improve liver function and hepatocellular integrity after hemorrhagic shock in rats; estrogen receptors mediate these effects at least partially.


Asunto(s)
Choque Hemorrágico , Animales , Citocinas/farmacología , Antagonistas del Receptor de Estrógeno/farmacología , Estrógenos/farmacología , Fulvestrant/farmacología , Hemorragia , Verde de Indocianina/farmacología , Hígado , Masculino , Ratas , Ratas Sprague-Dawley , Receptores de Estrógenos , Resucitación , Resveratrol/farmacología , Solución de Ringer/farmacología
3.
J Clin Med ; 11(18)2022 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-36143068

RESUMEN

Low-dose isoflurane stimulates spontaneous breathing. We, therefore, tested the hypothesis that isoflurane compared to propofol sedation for at least 48 h is associated with increased respiratory drive in intensive care patients after sedation stop. All patients in our intensive care unit receiving at least 48 h of isoflurane or propofol sedation in 2019 were included. The primary outcome was increased respiratory drive over 72 h after sedation stop, defined as an arterial carbon dioxide pressure below 35 mmHg and a base excess more than -2 mmol/L. Secondary outcomes were acid-base balance and ventilatory parameters. We analyzed 64 patients, 23 patients sedated with isoflurane and 41 patients sedated with propofol. Patients sedated with isoflurane were about three times as likely to show increased respiratory drive after sedation stop than those sedated with propofol: adjusted risk ratio [95% confidence interval]: 2.9 [1.3, 6.5], p = 0.010. After sedation stop, tidal volumes were significantly greater and arterial carbon dioxide partial pressures were significantly lower, while respiratory rates did not differ in isoflurane versus propofol-sedated patients. In conclusion, prolonged isoflurane use in intensive care patients is associated with increased respiratory drive after sedation stop. Beneficial effects of isoflurane sedation on respiratory drive may, thus, extend beyond the actual period of sedation.

4.
Molecules ; 27(16)2022 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-36014494

RESUMEN

Breath analysis provides great potential as a fast and non-invasive diagnostic tool for several diseases. Straight-chain aliphatic aldehydes were repeatedly detected in the breath of patients suffering from lung diseases using a variety of methods, such as mass spectrometry, ion mobility spectrometry, or electro-chemical sensors. Several studies found increased concentrations of exhaled aldehydes in patients suffering from lung cancer, inflammatory and infectious lung diseases, and mechanical lung injury. This article reviews the origin of exhaled straight-chain aliphatic aldehydes, available detection methods, and studies that found increased aldehyde exhalation in lung diseases.


Asunto(s)
Neoplasias Pulmonares , Compuestos Orgánicos Volátiles , Aldehídos/análisis , Biomarcadores/análisis , Pruebas Respiratorias/métodos , Espiración , Humanos , Neoplasias Pulmonares/diagnóstico
5.
Exp Anim ; 71(2): 231-239, 2022 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-34880161

RESUMEN

Rats are commonly used animals for laboratory experiments and many experiments require general anesthesia. However, the lack of published and reproducible intravenous anesthesia protocols for rats results in unnecessary animal use to establish new anesthesia techniques across institutions. We therefore developed an anesthesia protocol with propofol, ketamine, and rocuronium for mechanically ventilated rats, and evaluated vital parameters and plasma concentrations. 15 male Sprague-Dawley rats underwent inhalation induction with sevoflurane and tracheal, venous and arterial cannulation. After established venous access, sevoflurane was substituted by propofol and ketamine (ketofol). Rocuronium was added under mechanical ventilation for 7 h. Drug dosages were stepwise reduced to prevent accumulation. All animals survived the observation period and showed adequate depth of anesthesia. Mean arterial pressure and heart rate remained within normal ranges. Median propofol plasma concentrations remained stable: 1, 4, 7 h: 2.0 (interquartile range (IQR): 1.8-2.2), 2.1 (1.8-2.2), 1.8 (1.6-2.1) µg/ml, whereas median ketamine concentrations slightly differed after 7 h compared to 1 h: 1, 4, 7 h: 3.7 (IQR: 3.5-4.5), 3.8 (3.3-4.1), 3.8 (3.0-4.1) µg/ml. Median rocuronium plasma concentrations were lower after 4 and 7 h compared to 1 h: 1, 4, 7 h: 3.9 (IQR: 3.5-4.9), 3.2 (2.7-3.3), 3.0 (2.4-3.4) µg/ml. Our anesthesia protocol provides stable and reliable anesthesia in mechanically ventilated rats for several hours.


Asunto(s)
Anestésicos por Inhalación , Ketamina , Éteres Metílicos , Propofol , Anestesia General , Anestesia Intravenosa , Anestésicos por Inhalación/farmacología , Anestésicos Intravenosos/farmacología , Animales , Masculino , Éteres Metílicos/farmacología , Propofol/farmacología , Ratas , Ratas Sprague-Dawley , Rocuronio , Sevoflurano
6.
J Anal Methods Chem ; 2021: 6638036, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34395017

RESUMEN

BACKGROUND: Volatile acetone is a potential biomarker that is elevated in various disease states. Measuring acetone in exhaled breath is complicated by the fact that the molecule might be present as both monomers and dimers, but in inconsistent ratios. Ignoring the molecular form leads to incorrect measured concentrations. Our first goal was to evaluate the monomer-dimer ratio in ambient air, critically ill patients, and rats. Our second goal was to confirm the accuracy of the combined (monomer and dimer) analysis by comparison to a reference calibration system. METHODS: Volatile acetone intensities from exhaled air of ten intubated, critically ill patients, and ten ventilated Sprague-Dawley rats were recorded using ion-mobility spectrometry. Acetone concentrations in ambient air in an intensive care unit and in a laboratory were determined over 24 hours. The calibration reference was pure acetone vaporized by a gas generator at concentrations from 5 to 45 ppbv (parts per billion by volume). RESULTS: Acetone concentrations in ambient laboratory air were only slightly greater (5.6 ppbv; 95% CI 5.1-6.2) than in ambient air in an intensive care unit (5.1 ppbv; 95% CI 4.4-5.5; p < 0.001). Exhaled acetone concentrations were only slightly greater in rats (10.3 ppbv; 95% CI 9.7-10.9) than in critically ill patients (9.5 ppbv; 95% CI 7.9-11.1; p < 0.001). Vaporization yielded acetone monomers (1.3-5.3 mV) and dimers (1.4-621 mV). Acetone concentrations (ppbv) and corresponding acetone monomer and dimer intensities (mV) revealed a high coefficient of determination (R 2 = 0.96). The calibration curve for acetone concentration (ppbv) and total acetone (monomers added to twice the dimers; mV) was described by the exponential growth 3-parameter model, with an R 2 = 0.98. CONCLUSION: The ratio of acetone monomer and dimer is inconsistent and varies in ambient air from place-to-place and across individual humans and rats. Monomers and dimers must therefore be considered when quantifying acetone. Combining the two accurately assesses total volatile acetone.

7.
Antimicrob Resist Infect Control ; 10(1): 99, 2021 06 30.
Artículo en Inglés | MEDLINE | ID: mdl-34193293

RESUMEN

BACKGROUND: The unrestricted use of linezolid has been linked to the emergence of linezolid-resistant Staphylococcus epidermidis (LRSE). We report the effects of combined antibiotic stewardship and infection control measures on the spread of LRSE in an intensive care unit (ICU). METHODS: Microbiological data were reviewed to identify all LRSE detected in clinical samples at an ICU in southwest Germany. Quantitative data on the use of antibiotics with Gram-positive coverage were obtained in defined daily doses (DDD) per 100 patient-days (PD). In addition to infection control measures, an antibiotic stewardship intervention was started in May 2019, focusing on linezolid restriction and promoting vancomycin, wherever needed. We compared data from the pre-intervention period (May 2018-April 2019) to the post-intervention period (May 2019-April 2020). Whole-genome sequencing (WGS) was performed to determine the genetic relatedness of LRSE isolates. RESULTS: In the pre-intervention period, LRSE were isolated from 31 patients (17 in blood cultures). The average consumption of linezolid and daptomycin decreased from 7.5 DDD/100 PD and 12.3 DDD/100 PD per month in the pre-intervention period to 2.5 DDD/100 PD and 5.7 DDD/100 PD per month in the post-intervention period (p = 0.0022 and 0.0205), respectively. Conversely, vancomycin consumption increased from 0.2 DDD/100 PD per month to 4.7 DDD/100 PD per month (p < 0.0001). In the post-intervention period, LRSE were detected in 6 patients (4 in blood cultures) (p = 0.0065). WGS revealed the predominance of one single clone. CONCLUSIONS: Complementing infection control measures by targeted antibiotic stewardship interventions was beneficial in containing the spread of LRSE in an ICU.


Asunto(s)
Programas de Optimización del Uso de los Antimicrobianos , Farmacorresistencia Bacteriana , Control de Infecciones/métodos , Linezolid/farmacología , Infecciones Estafilocócicas/prevención & control , Staphylococcus epidermidis/efectos de los fármacos , Infección Hospitalaria/microbiología , Infección Hospitalaria/prevención & control , Alemania , Humanos , Unidades de Cuidados Intensivos , Staphylococcus epidermidis/genética , Secuenciación Completa del Genoma
8.
Molecules ; 26(11)2021 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-34064214

RESUMEN

Exhaled aliphatic aldehydes were proposed as non-invasive biomarkers to detect increased lipid peroxidation in various diseases. As a prelude to clinical application of the multicapillary column-ion mobility spectrometry for the evaluation of aldehyde exhalation, we, therefore: (1) identified the most abundant volatile aliphatic aldehydes originating from in vitro oxidation of various polyunsaturated fatty acids; (2) evaluated emittance of aldehydes from plastic parts of the breathing circuit; (3) conducted a pilot study for in vivo quantification of exhaled aldehydes in mechanically ventilated patients. Pentanal, hexanal, heptanal, and nonanal were quantifiable in the headspace of oxidizing polyunsaturated fatty acids, with pentanal and hexanal predominating. Plastic parts of the breathing circuit emitted hexanal, octanal, nonanal, and decanal, whereby nonanal and decanal were ubiquitous and pentanal or heptanal not being detected. Only pentanal was quantifiable in breath of mechanically ventilated surgical patients with a mean exhaled concentration of 13 ± 5 ppb. An explorative analysis suggested that pentanal exhalation is associated with mechanical power-a measure for the invasiveness of mechanical ventilation. In conclusion, exhaled pentanal is a promising non-invasive biomarker for lipid peroxidation inducing pathologies, and should be evaluated in future clinical studies, particularly for detection of lung injury.


Asunto(s)
Aldehídos/análisis , Pruebas Respiratorias , Respiración Artificial , Compuestos Orgánicos Volátiles/análisis , Humanos , Técnicas In Vitro , Proyectos Piloto
9.
Molecules ; 26(9)2021 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-34067078

RESUMEN

High inspired oxygen during mechanical ventilation may influence the exhalation of the previously proposed breath biomarkers pentanal and hexanal, and additionally induce systemic inflammation. We therefore investigated the effect of various concentrations of inspired oxygen on pentanal and hexanal exhalation and serum interleukin concentrations in 30 Sprague Dawley rats mechanically ventilated with 30, 60, or 93% inspired oxygen for 12 h. Pentanal exhalation did not differ as a function of inspired oxygen but increased by an average of 0.4 (95%CI: 0.3; 0.5) ppb per hour, with concentrations doubling from 3.8 (IQR: 2.8; 5.1) ppb at baseline to 7.3 (IQR: 5.0; 10.8) ppb after 12 h. Hexanal exhalation was slightly higher at 93% of inspired oxygen with an average difference of 0.09 (95%CI: 0.002; 0.172) ppb compared to 30%. Serum IL-6 did not differ by inspired oxygen, whereas IL-10 at 60% and 93% of inspired oxygen was greater than with 30%. Both interleukins increased over 12 h of mechanical ventilation at all oxygen concentrations. Mechanical ventilation at high inspired oxygen promotes pulmonary lipid peroxidation and systemic inflammation. However, the response of pentanal and hexanal exhalation varies, with pentanal increasing by mechanical ventilation, whereas hexanal increases by high inspired oxygen concentrations.


Asunto(s)
Aldehídos/farmacología , Espiración/efectos de los fármacos , Oxígeno/farmacología , Respiración Artificial , Animales , Pruebas Respiratorias , Citocinas/sangre , Inflamación/patología , Masculino , Presión Parcial , Ratas Sprague-Dawley
10.
Anesth Analg ; 133(1): 263-273, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33929393

RESUMEN

BACKGROUND: Mechanical ventilation injures lungs, but there are currently no reliable methods for detecting early injury. We therefore evaluated whether exhaled pentanal, a lipid peroxidation product, might be a useful breath biomarker for stretch-induced lung injury in rats. METHODS: A total of 150 male Sprague-Dawley rats were investigated in 2 substudies. The first randomly assigned 75 rats to 7 hours of mechanical ventilation at tidal volumes of 6, 8, 12, 16, and 20 mL·kg-1. The second included 75 rats. A reference group was ventilated at a tidal volume of 6 mL·kg-1 for 10 hours 4 interventional groups were ventilated at a tidal volume of 6 mL·kg-1 for 1 hour, and then for 0.5, 1, 2, or 3 hours at a tidal volume of 16 mL.kg-1 before returning to a tidal volume of 6 mL·kg-1 for additional 6 hours. Exhaled pentanal was monitored by multicapillary column-ion mobility spectrometry. The first substudy included cytokine and leukocyte measurements in blood and bronchoalveolar fluid, histological assessment of the proportion of alveolar space, and measurements of myeloperoxidase activity in lung tissue. The second substudy included measurements of pentanal in arterial blood plasma, cytokine and leukocyte concentrations in bronchoalveolar fluid, and cleaved caspase 3 in lung tissue. RESULTS: Exhaled pentanal concentrations increased by only 0.5 ppb·h-1 (95% confidence interval [CI], 0.3-0.6) when rats were ventilated at 6 mL·kg-1. In contrast, exhaled pentanal concentrations increased substantially and roughly linearly at higher tidal volumes, up to 3.1 ppb·h-1 (95% CI, 2.3-3.8) at tidal volumes of 20 mL·kg-1. Exhaled pentanal increased at average rates between 1.0 ppb·h-1 (95% CI, 0.3-1.7) and 2.5 ppb·h-1 (95% CI, 1.4-3.6) after the onset of 16 mL·kg-1 tidal volumes and decreased rapidly by a median of 2 ppb (interquartile range [IQR], 0.9-3.2), corresponding to a 38% (IQR, 31-43) reduction when tidal volume returned to 6 mL·kg-1. Tidal volume, inspiratory pressure, and mechanical power were positively associated with pentanal exhalation. Exhaled and plasma pentanal were uncorrelated. Alveolar space decreased and inflammatory markers in bronchoalveolar lavage fluid increased in animals ventilated at high tidal volumes. Short, intermittent ventilation at high tidal volumes for up to 3 hours increased neither inflammatory markers in bronchoalveolar fluid nor the proportion of cleaved caspase 3 in lung tissue. CONCLUSIONS: Exhaled pentanal is a potential biomarker for early detection of ventilator-induced lung injury in rats.


Asunto(s)
Aldehídos/metabolismo , Espiración/fisiología , Respiración Artificial/efectos adversos , Lesión Pulmonar Inducida por Ventilación Mecánica/metabolismo , Aldehídos/análisis , Anestésicos por Inhalación/administración & dosificación , Animales , Biomarcadores/metabolismo , Líquido del Lavado Bronquioalveolar/química , Espiración/efectos de los fármacos , Masculino , Ratas , Ratas Sprague-Dawley , Sevoflurano/administración & dosificación , Volumen de Ventilación Pulmonar/efectos de los fármacos , Volumen de Ventilación Pulmonar/fisiología , Lesión Pulmonar Inducida por Ventilación Mecánica/etiología
11.
Anesth Analg ; 132(1): 110-118, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32118620

RESUMEN

BACKGROUND: Propofol can be measured in exhaled gas. Exhaled and plasma propofol concentrations correlate well, but the relationship with tissue concentrations remains unknown. We thus evaluated the relationship between exhaled, plasma, and various tissue propofol concentrations. Because the drug acts in the brain, we focused on the relationship between exhaled and brain tissue propofol concentrations. METHODS: Thirty-six male Sprague-Dawley rats were anesthetized with propofol, ketamine, and rocuronium for 6 hours. Animals were randomly assigned to propofol infusions at 20, 40, or 60 mg·kg·h (n = 12 per group). Exhaled propofol concentrations were measured at 15-minute intervals by multicapillary column-ion mobility spectrometry. Arterial blood samples, 110 µL each, were collected 15, 30, and 45 minutes, and 1, 2, 4, and 6 hours after the propofol infusion started. Propofol concentrations were measured in brain, lung, liver, kidney, muscle, and fat tissue after 6 hours. The last exhaled and plasma concentrations were used for linear regression analyses with tissue concentrations. RESULTS: The correlation of exhaled versus plasma concentrations (R = 0.71) was comparable to the correlation of exhaled versus brain tissue concentrations (R = 0.75) at the end of the study. In contrast, correlations between plasma and lung and between lung and exhaled propofol concentrations were poor. Less than a part-per-thousand of propofol was exhaled over 6 hours. CONCLUSIONS: Exhaled propofol concentrations correlate reasonably well with brain tissue and plasma concentrations in rats, and may thus be useful to estimate anesthetic drug effect. The equilibration between plasma propofol and exhaled gas is apparently independent of lung tissue concentration. Only a tiny fraction of administered propofol is eliminated via the lungs, and exhaled quantities thus have negligible influence on plasma concentrations.


Asunto(s)
Anestésicos Intravenosos/metabolismo , Encéfalo/metabolismo , Plasma/metabolismo , Propofol/metabolismo , Anestésicos Intravenosos/administración & dosificación , Animales , Encéfalo/efectos de los fármacos , Pruebas Respiratorias/métodos , Espiración/efectos de los fármacos , Masculino , Plasma/efectos de los fármacos , Propofol/administración & dosificación , Distribución Aleatoria , Ratas , Ratas Sprague-Dawley , Distribución Tisular/efectos de los fármacos , Distribución Tisular/fisiología
12.
J Anesth ; 35(3): 390-393, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32691227

RESUMEN

During the SARS-CoV-2 pandemic in 2020, departments of anesthesiology worldwide have encountered new and unique challenges. In this short communication, we present and assess our recommendations for orotracheal intubation, a frequent high-risk procedure. We will point out that interdisciplinary cooperation with "non-patient care" departments like the Institute for Medical Microbiology and Hygiene tremendously helped us in creating this and other new, clear standards for anesthesiological procedures. Moreover, to reliably implement our newly created measures, we distributed incisive posters and organized comprehensive training sessions. Eventually, we summarize and analyze the occurring problems of our suggestions for intubation during their realization.


Asunto(s)
Anestesiología , COVID-19 , Humanos , Intubación Intratraqueal , Pandemias , SARS-CoV-2
13.
J Breath Res ; 15(1): 016003, 2020 10 24.
Artículo en Inglés | MEDLINE | ID: mdl-33103661

RESUMEN

Inflammation may alter volatile organic compounds (VOCs) in exhaled breath. We therefore used ion mobility spectrometry (IMS) to evaluate exhaled breath components in two non-infectious inflammatory models. Fifty male Sprague Dawley rats were anesthetized and ventilated for 24 h. Five treatments were randomly assigned: (1) lipopolysaccharide low dose [5 mg/kg]; (2) lipopolysaccharide high dose [10 mg/kg]; (3) alpha toxin low dose [40 µg/kg]; (4) alpha toxin high dose [80 µg/kg]; and, (5) NaCl 0.9% as control group. Gas was sampled from the expiratory line of the ventilator every 20 min and analyzed with IMS combined with a multi-capillary column. VOCs were identified by comparison with an established database. Survival analysis was performed by log-rank test, other analyses by one-way or paired ANOVA-tests and post-hoc analysis according to Holm-Sidak. Rats given NaCl and low-dose alpha toxin survived 24 h. The median survival time in alpha toxin high-dose group was 23 (95%-confidence interval (CI): 21, 24) h. In contrast, the median survival time in rats given high-dose lipopolysaccharide was 12 (95% CI: 9, 14) and only 13 (95% CI: 10, 16) h in those given high-dose lipopolysaccharide. 73 different VOCs were detected, of which 35 were observed only in the rats, 38 could be found both in the blank measurements of ventilator air and in the exhaled air of the rats. Forty-nine of the VOCs were identifiable from a registry of compounds. Exhaled volatile compounds were comparable in each group before injection of lipopolysaccharide and alpha toxin. In the LPS groups, 1-pentanol increased and 2-propanol decreased. After alpha toxin treatment, 1-butanol and 1-pentanol increased whereas butanal and isopropylamine decreased. Induction of a non-infectious systemic inflammation (niSI) by lipopolysaccharide and alpha toxin changes VOCs in exhaled breath. Exhalome analysis may help identify niSI.


Asunto(s)
Toxinas Bacterianas/administración & dosificación , Proteínas Hemolisinas/administración & dosificación , Inflamación/patología , Ventilación Pulmonar , Compuestos Orgánicos Volátiles/análisis , Animales , Análisis Químico de la Sangre , Pruebas Respiratorias , Citocinas/sangre , Espiración , Hemodinámica , Estimación de Kaplan-Meier , Lipopolisacáridos/administración & dosificación , Masculino , Ratas Sprague-Dawley , Análisis de Supervivencia
14.
Metabolites ; 10(6)2020 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-32549262

RESUMEN

Systemic inflammation alters the composition of exhaled breath, possibly helping clinicians diagnose conditions such as sepsis. We therefore evaluated changes in exhaled breath of rats given tumor necrosis factor-alpha (TNF-α). Thirty male Sprague-Dawley rats were randomly assigned to three groups (n = 10 each) with intravenous injections of normal saline (control), 200 µg·kg-1 bodyweight TNF-α (TNF-α-200), or 600 µg·kg-1 bodyweight TNF-α (TNF-α-600), and were observed for 24 h or until death. Animals were ventilated with highly-purified synthetic air to analyze exhaled air by multicapillary column-ion mobility spectrometry. Volatile organic compounds (VOCs) were identified from a database. We recorded blood pressure and cardiac output, along with cytokine plasma concentrations. Control rats survived the 24 h observation period, whereas mean survival time decreased to 22 h for TNF-α-200 and 23 h for TNF-α-600 rats. Mean arterial pressure decreased in TNF-α groups, whereas IL-6 increased, consistent with mild to moderate inflammation. Hundreds of VOCs were detected in exhalome. P-cymol increased by a factor-of-two 4 h after injection of TNF-α-600 compared to the control and TNF-α-200. We found that 1-butanol and 1-pentanol increased in both TNF-α groups after 20 h compared to the control. As breath analysis distinguishes between two doses of TNF-α and none, we conclude that it might help clinicians identify systemic inflammation.

15.
Antioxidants (Basel) ; 8(9)2019 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-31540398

RESUMEN

Melatonin receptors are highly relevant for the hepatoprotective effects of the pineal hormone melatonin after experimental hemorrhagic shock in rats. In this study, we sought to determine the spatial expression pattern and a putative regulation of two melatonin receptors, membrane bound type 1 and 2 (MT1 and MT2), in the liver of rats. In a male rat model (Sprague Dawley) of hemorrhage and resuscitation, we investigated the gene expression and protein of MT1 and MT2 in rat liver by utilizing real-time quantitative polymerase chain reaction, a western blot analysis, and immunohistochemistry. Plasma melatonin content was measured by an enzyme-linked immunosorbent assay. Male rats underwent hemorrhage and were resuscitated with shed blood and a Ringer's solution (n = 8 per group). After 90 min of hemorrhage, animals were given vehicle, melatonin, or ramelteon (each 1.0 mg/kg intravenously). Sham-operated controls did not undergo hemorrhage but were treated likewise. Plasma melatonin was significantly increased in all groups treated with melatonin and also after hemorrhagic shock. Only MT1, but not the MT2 messenger ribonucleic acid (mRNA) and protein, was detected in the rat liver. The MT1 protein was located in pericentral fields of liver lobules in sham-operated animals. After hemorrhagic shock and treatment with melatonin or ramelteon, the hepatic MT1 protein amount was significantly attenuated in all groups compared to sham controls (50% reduction; p < 0.001). With respect to MT1 mRNA, no significant changes were observed between groups (p = 0.264). Our results indicate that both endogenous melatonin exposure from hemorrhagic shock, as well as exogenous melatonin and ramelteon exposure, may attenuate melatonin receptors in rat hepatocytes, possibly by means of desensitization.

16.
Diagnostics (Basel) ; 9(3)2019 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-31480421

RESUMEN

The measurement of the liver function via the plasma disappearance rate of indocyanine green (PDRICG) is a sensitive bed-side tool in critical care. Yet, recent evidence has questioned the value of this method for hyperdynamic conditions. To evaluate this technique in different hemodynamic settings, we analyzed the PDRICG and corresponding pharmacokinetic models after endotoxemia or hemorrhagic shock in rats. Male anesthetized Sprague-Dawley rats underwent hemorrhage (mean arterial pressure 35 ± 5 mmHg, 90 min) and 2 h of reperfusion, or lipopolysaccharide (LPS) induced moderate or severe (1.0 vs. 10 mg/kg) endotoxemia for 6 h (each n = 6). Afterwards, PDRICG was measured, and pharmacokinetic models were analyzed using nonlinear mixed effects modeling (NONMEM®). Hemorrhagic shock resulted in a significant decrease of PDRICG, compared with sham controls, and a corresponding attenuation of the calculated ICG clearance in 1- and 2-compartment models, with the same log-likelihood. The induction of severe, but not moderate endotoxemia, led to a significant reduction of PDRICG. The calculated ICG blood clearance was reduced in 1-compartment models for both septic conditions. 2-compartment models performed with a significantly better log likelihood, and the calculated clearance of ICG did not correspond well with PDRICG in both LPS groups. 3-compartment models did not improve the log likelihood in any experiment. These results demonstrate that PDRICG correlates well with ICG clearance in 1- and 2-compartment models after hemorrhage. In endotoxemia, best described by a 2-compartment model, PDRICG may not truly reflect the ICG clearance.

17.
Biomed Chromatogr ; 33(8): e4540, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30924939

RESUMEN

The combination of propofol, ketamine and rocuronium can be used for anesthesia of ventilated rats. However, reliable pharmacokinetic models of these drugs have yet to be developed in rats, and consequently optimal infusion strategies are also unknown. Development of pharmacokinetic models requires repeated measurements of drug concentrations. In small animals, samples must be tiny to avoid excessing blood extraction. We therefore developed a drug assay system using high-performance liquid chromatography coupled with quadrupole mass spectrometry that simultaneously determines the concentration of all three drugs in just 10 µL rat plasma. We established a plasma extraction protocol, using acetonitrile as the precipitating reagent. Calibration curves were linear with R2 = 0.99 for each drug. Mean recovery from plasma was 91-93% for propofol, 89-93% for ketamine and 90-92% for rocuronium. The assay proved to be accurate for propofol 4.1-8.3%, ketamine 1.9-7.8% and rocuronium -3.6-4.7% relative error. The assay was also precise; the intra-day precisions were propofol 2.0-4.0%, ketamine 2.7-2.9% and rocuronium 2.9-3.3% relative standard deviation. Finally, the method was successfully applied to measurement the three drugs in rat plasma samples. Mean plasma concentrations with standard deviations were propofol 2.0 µg/mL ±0.5%, ketamine 3.9 µg/mL ±1.0% and rocuronium 3.2 µg/mL ±0.8% during ventilation.


Asunto(s)
Cromatografía Liquida/métodos , Ketamina/sangre , Espectrometría de Masas/métodos , Propofol/sangre , Rocuronio/sangre , Animales , Ketamina/química , Ketamina/farmacocinética , Límite de Detección , Modelos Lineales , Masculino , Proyectos Piloto , Propofol/química , Propofol/farmacocinética , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Rocuronio/química , Rocuronio/farmacocinética
18.
Crit Care Med ; 47(2): 239-246, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30365402

RESUMEN

OBJECTIVES: To characterize volatile organic compounds in breath exhaled by ventilated care patients with acute kidney injury and changes over time during dialysis. DESIGN: Prospective observational feasibility study. SETTING: Critically ill patients on an ICU in a University Hospital, Germany. PATIENTS: Twenty sedated, intubated, and mechanically ventilated patients with acute kidney injury and indication for dialysis. INTERVENTIONS: Patients exhalome was evaluated from at least 30 minutes before to 7 hours after beginning of continuous venovenous hemodialysis. MEASUREMENTS AND MAIN RESULTS: Expired air samples were aspirated from the breathing circuit at 20-minute intervals and analyzed using multicapillary column ion-mobility spectrometry. Volatile organic compound intensities were compared with a ventilated control group with normal renal function. A total of 60 different signals were detected by multicapillary column ion-mobility spectrometry, of which 44 could be identified. Thirty-four volatiles decreased during hemodialysis, whereas 26 remained unaffected. Forty-five signals showed significant higher intensities in patients with acute kidney injury compared with control patients with normal renal function. Among these, 30 decreased significantly during hemodialysis. Volatile cyclohexanol (23 mV; 2575th, 19-38), 3-hydroxy-2-butanone (16 mV, 9-26), 3-methylbutanal (20 mV; 14-26), and dimer of isoprene (26 mV; 18-32) showed significant higher intensities in acute kidney impairment compared with control group (12 mV; 10-16 and 8 mV; 7-14 and not detectable and 4 mV; 0-6; p < 0.05) and a significant decline after 7 hours of continuous venovenous hemodialysis (16 mV; 13-21 and 7 mV; 6-13 and 9 mV; 8-13 and 14 mV; 10-19). CONCLUSIONS: Exhaled concentrations of 45 volatile organic compounds were greater in critically ill patients with acute kidney injury than in patients with normal renal function. Concentrations of two-thirds progressively decreased during dialysis. Exhalome analysis may help quantify the severity of acute kidney injury and to gauge the efficacy of dialysis.


Asunto(s)
Lesión Renal Aguda/metabolismo , Compuestos Orgánicos Volátiles/metabolismo , Lesión Renal Aguda/terapia , Anciano , Pruebas Respiratorias , Espiración , Estudios de Factibilidad , Femenino , Humanos , Masculino , Estudios Prospectivos , Diálisis Renal , Respiración Artificial , Compuestos Orgánicos Volátiles/análisis
19.
Rev. bras. anestesiol ; 67(6): 571-577, Nov.-Dec. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-897792

RESUMEN

Abstract Background and objective Regular postanesthesia visits allow the detection of anesthesia related complications and increase patient satisfaction. Consequently, the performance of postanesthesia visits has been recommended after certain types of anesthesia. However, no data is available concerning the current practice of postanesthesia visits. Therefore, this study was designed to investigate quantity, organization, contents, significance and problems of postanesthesia visits in Germany. Methods For this prospective closed-design survey, a questionnaire, consisting of 13 questions, was designed and tested for objectivity, reliability and validity. Subsequently, 3955 registered anesthesiologists were contacted via email to answer this survey. Results Return rate was 31.4%; 958 questionnaires were included in the study. Only a small portion of patients was estimated to receive a postanesthesia visit (median: 20.0%). In hospitals with a specific postanesthesia visit service, this number was significantly higher (median: 65.0%, p < 0.001) vs. no postanesthesia visit service. Postanesthesia visits usually lasted less than 5 minutes (60.0%), and were typically conducted on the day of surgery (48.0%), after regular working hours (55.0%). 38.0% of the respondents reported to detect perioperative complications intermittently during their visits. While 98.0% of all respondents believe that postanesthesia visits improve the quality of their own work, 86.0% of the participants complain a lack of time for this task. Conclusions Our survey indicates that current working conditions prevent a regular postanesthesia visit routine. Considering the high appreciation of postanesthesia visits by anesthesiologists, as well as the relevant incidence of postoperative complications detected during these visits, it seems desirable to consider organizational improvements for postanesthesia care.


Resumo Justificativa e objetivo As visitas regulares pós-anestesia (VPA) permitem detectar complicações relacionadas à anestesia e aumentar a satisfação do paciente. Portanto, a VPA é recomendada após certos tipos de anestesia. Porém, não há dados disponíveis sobre a prática atual de VPA. Logo, este estudo foi projetado para investigar a quantidade, a organização, o conteúdo, a significância e os problemas da VPA na Alemanha. Método Para esta pesquisa de natureza fechada e prospectiva, um questionário com 13 perguntas foi criado e testado para identificar a objetividade, confiabilidade e validade. Posteriormente, 3.955 anestesiologistas registrados foram contatados via e-mail para responder a pesquisa. Resultados A taxa de retorno foi de 31,4%; 958 questionários foram incluídos no estudo. Apenas uma pequena parte dos pacientes foi designada para receber uma VPA (mediana: 20%). Em hospitais com serviço específico de VPA, esse número foi significativamente maior (mediana: 65%, p < 0,001) vs. ausência de serviço de VPA. As VPA normalmente duraram menos de cinco minutos (60%) e foram tipicamente conduzidas no dia da cirurgia (48%), após o turno normal de trabalho (55%). Dentre os que responderam o questionário, 38% relataram detectar complicações perioperatórias de forma intermitente durante as visitas. Enquanto 98% dos entrevistados acreditam que as VPA melhoram a qualidade de seu próprio trabalho, 86% se queixam de falta de tempo para essa tarefa. Conclusões Nossa pesquisa indica que as condições atuais de trabalho impedem a feitura rotineira de VPA. Considerando a alta valorização das VPA por anestesiologistas, bem como a incidência relevante de complicações no pós-operatório detectadas durante essas visitas, parece desejável considerar melhorias organizacionais para a assistência após a anestesia.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Cuidados Posoperatorios/estadística & datos numéricos , Pautas de la Práctica en Medicina , Anestesiología , Estudios Prospectivos , Encuestas de Atención de la Salud , Alemania , Persona de Mediana Edad
20.
J Breath Res ; 11(3): 036005, 2017 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-28825414

RESUMEN

Propofol in exhaled breath can be measured and may provide a real-time estimate of plasma concentration. However, propofol is absorbed in plastic tubing, thus estimates may fail to reflect lung/blood concentration if expired gas is not extracted directly from the endotracheal tube. We evaluated exhaled propofol in five ventilated ICU patients who were sedated with propofol. Exhaled propofol was measured once per minute using ion mobility spectrometry. Exhaled air was sampled directly from the endotracheal tube and at the ventilator end of the expiratory side of the anesthetic circuit. The circuit was disconnected from the patient and propofol was washed out with a separate clean ventilator. Propofol molecules, which discharged from the expiratory portion of the breathing circuit, were measured for up to 60 h. We also determined whether propofol passes through the plastic of breathing circuits. A total of 984 data pairs (presented as median values, with 95% confidence interval), consisting of both concentrations were collected. The concentration of propofol sampled near the patient was always substantially higher, at 10.4 [10.25-10.55] versus 5.73 [5.66-5.88] ppb (p < 0.001). The reduction in concentration over the breathing circuit tubing was 4.58 [4.48-4.68] ppb, 3.46 [3.21-3.73] in the first hour, 4.05 [3.77-4.34] in the second hour, and 4.01 [3.36-4.40] in the third hour. Out-gassing propofol from the breathing circuit remained at 2.8 ppb after 60 h of washing out. Diffusion through the plastic was not observed. Volatile propofol binds or adsorbs to the plastic of a breathing circuit with saturation kinetics. The bond is reversible so propofol can be washed out from the plastic. Our data confirm earlier findings that accurate measurements of volatile propofol require exhaled air to be sampled as close as possible to the patient.


Asunto(s)
Intubación Intratraqueal/instrumentación , Propofol/análisis , Respiración Artificial/instrumentación , Anciano , Anestesia , Espiración , Femenino , Humanos , Masculino , Persona de Mediana Edad , Volatilización
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...