Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Neurol Sci ; 463: 123115, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38964268

RESUMEN

OBJECTIVE: Blood neurofilament light chain (NfL) is robustly associated with disease worsening in multiple sclerosis (MS), though potentially affected by concomitant factors also determining neuro-axonal loss. We investigated the association between plasma NfL (pNfL) measured with Lumipulse™ immunoassay and demographic and clinical variables in MS. METHODS: This cross-sectional study included 685 people with MS (age 49.7 ± 12.4 years; sex 65.55% females). On the same day, we collected plasma samples, along with demographics, comorbidities, and clinical variables (MS disease duration, expanded disability status scale (EDSS), Symbol Digit Modalities Test (SDMT), descriptor of disease progression, current disease modifying treatment (DMT), number of previous DMTs, evidence of disease activity in the past year (i.e. relapse or MRI new lesions), EDSS progression). pNfL was evaluated using Lumipulse™ fully automated chemiluminescent enzyme immunoassay. RESULTS: On multivariable linear regression model, higher pNfL was associated with higher EDSS (Coeff = 1.73; 95%CI 0.78, 2.68; p < 0.01), recent disease activity (Coeff = 15.70; 95%CI = 5.35, 26.06; p < 0.01), and presence of cardiovascular comorbidity (Coeff = 3.84; 95%CI 0.48, 7.20; p = 0.025). Lower pNfL was found in patients on DMT treatment (Coeff = -10.23; 95%CI -18.42, -2.04; p = 0.015), when compared with no DMT (reference). For 77.81% of our population there was correspondence between pNfL levels and two previously-validated cutoffs. CONCLUSIONS: pNfL measured using Lumipulse™ confirms known associations with MS activity, disability and treatments, and related confounding (e.g., cardiovascular comorbidity), thus granting further utilization in research and clinical practice.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38940613

RESUMEN

PURPOSE: To evaluate the initial impact of a combined oral contraceptive (COC) containing norgestimate (NGM) on female sexuality and on circulating androgen levels in users. MATERIALS AND METHODS: Six months modification in the McCoy Female Sexuality Questionnaire (MFSQ) and testosterone (T) and dehydroepiandrosterone sulphate (DHEAS) serum levels in women starting a monophasic pill containing ethinyl-estradiol (EE) 35 µg and NGM 0.250 mg. RESULTS: The study was completed by 36 subjects. There was a significant increase in MFSQ during treatment (p < 0.0001) (and its domains with the exclusion of vaginal lubrication domain) with concomitant decreases in T (-4.45%, p < 0.0001) and DHEAS (-19.41%, p < 0.0001) serum levels. CONCLUSIONS: Contraception with EE/NGM was associated with a short term non-deteriorating effect on sexuality despite the evident decrease in androgen levels. Female sexuality during COC use is a complex topic and is not only linked with changes in serum androgen levels.


EE/NGM treatment has a short term non-deteriorating effect on sexuality despite the evident decrease in androgen serum levels.

3.
J Neurol ; 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38777960

RESUMEN

OBJECTIVE: The wearing-off phenomenon is common in people with multiple sclerosis (MS) treated with ocrelizumab. We aim to evaluate the presence and severity of wearing-off to ocrelizumab in relation to demographic and MS clinical variables, immune profiling, and a marker of neuroaxonal damage (plasma neurofilament light chain (pNfl)). METHODS: This cross-sectional study included MS patients treated with ocrelizumab from at least 1 year. Wearing-off questionnaire and blood samples were collected between 21 and 23 weeks after the previous ocrelizumab infusion. Lymphocyte subpopulations were evaluated on peripheral blood using flow cytometry. PNfl was evaluated using fully automated chemiluminescent enzyme immunoassay. RESULTS: We included 106 people with MS (age 49.5 ± 11.6 years; females 42.3%; wearing-off 57.6%). On regression models, wearing-off was associated with higher pNfl, CD8, CD3, and CD3CD27 lymphocytes. Most frequent wearing-off symptoms were cognitive, sensory, and balance problems; wearing-off started < 1 week (9.4%), 1-4 weeks (10.7%) or > 4 weeks (10.7%) before infusion; 44.8% of the complaints were moderate to severe. Severity of wearing-off was associated with higher pNfl and CD8 lymphocytes. CONCLUSIONS: Wearing-off is common in people with MS treated with ocrelizumab, and is associated with reduced immunomodulation (higher T lymphocytes) and increased neuroaxonal damage, suggesting reduced treatment response.

4.
Prostate ; 2024 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-38798011

RESUMEN

BACKGROUND: There is a strong clinical need to fill the gap of identifying clinically significant prostate cancer (csPCa) in men with prostate-specific antigen (PSA) gray zone values. Promising, but not definitive results have been obtained using PSA derivatives such as prostate health index (PHI) and PHI density (PHID) and the percentage (-2)proPSA/free PSA (%p2PSA/fPSA). Thus, this study aimed to compare the diagnostic value of PHI, PHID, %proPSA/fPSA, and (-2)proPSA/freePSA density (-2pPSA/fPSAD) for csPCa in the patients with PSA within 2-10 ng/mL. METHODS: Serum samples and clinicopathological features were prospectively collected from 142 patients who underwent robot-assisted radical prostatectomy  between September 2021 and December 2023. According to the inclusion criteria, the patients with total PSA  within 2 and 10 ng/mL and negative or suspicious digital rectal examination  were enrolled. We used two different classifications for csPCa: 1) patients with Gleason score (GS) ≥ 7(4 + 3) and 2) patients with GS ≥ 7(3 + 4). The receiver operating characteristic curves and the area under the curve (AUC) values were used to assess the diagnostic performance. RESULTS: Of the 142 men included, 116 (82%) patients were diagnosed with csPCa as GS ≥ 3 + 4 and 107 (75%) defined as csPCa as GS ≥ 7(4 + 3), respectively. We found that p2PSA/fPSA, p2PSA/fPSAD, PHI, and PHID were significantly higher in csPCa classified as GS ≥ 7(3 + 4) as well as GS ≥ 7(4 + 3), with p-values 0.027, 0.054, 0.0016, and 0.0027, respectively. AUCs of the analyzed variables were higher when used to predict csPCa as GS ≥ 6 compared to csPCa as GS ≥7(4 + 3), with an AUC equal, respectively, to 0.679 (95% CI: 0.571-0.786), 0.685 (95% CI: 0.571-0.799), 0.737 (95% CI: 0.639-0.836), and 0.736 (95% CI: 0.630-0.841) in the first subgroup and with an AUC equal, respectively, to 0.653 (95% CI: 0.552-0.754), 0.665 (95% CI: 0.560-0.770), 0.668 (95% CI: 0.568-0.769), and 0.670 (95% CI: 0.567-0.773) in the second, respectively. Both PHID and p2PSA/fPSAD allowed improvement in the diagnostic accuracy with respect to PHI and p2PSA/fPSA ratio, however the differences were not statistically significant (p = 0.409, 0.180 for csPCa as G ≥ Gleason grade (GG) 2 and 0.558 and 0.087 for csPCa as G ≥ GG3, respectively). We found that PHI, PHID, p2PSA/fPSA ratio, and p2PSA/fPSAD showed higher sensitivity, specificity, and positive predictive value when used to predict csPCa as GG ≥ 2, whereas negative predictive value of all four parameters was higher when used to predict GG ≥ 3. CONCLUSIONS: In men with a PSA level between 2 and 10 ng/mL, PHI and PHID, p2PSA/fPSA, and p2PSA/fPSAD showed good diagnostic performance for postoperative csPCa. However, PHID and p2PSA/fPSAD had a small advantage over PHI which needs to be further investigated for the reduction of unnecessary surgical interventions. This finding suggests that it could be a promising biomarker for making the treatment-decision strategy.

5.
J Gynecol Obstet Hum Reprod ; 52(5): 102569, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36878392

RESUMEN

BACKGROUND: The occurrence of COVID-19 during the pregnancy can cause several negative maternal and neonatal outcomes. Nasopharyngeal viral load is associated with inflammatory markers and might influence the disease severity in non-pregnant patients, but there are no data about the relationship between viral load and perinatal outcomes in pregnant patients. OBJECTIVE: To investigate the hypothesis that nasopharyngeal SARS-CoV-2 load (estimated with real-time polymerase chain reaction delta cycle (ΔCt), measured in hospital clinical laboratories) is associated with perinatal outcomes, when COVID-19 is diagnosed in the third trimester of pregnancy. STUDY DESIGN: International, retrospective, observational, multi-center, cohort study enrolling 390 women (393 neonates, three pairs of twins), analyzed with multivariate generalized linear models with skewed distributions (gamma) and identity link. The analyses were conducted for the whole population and then followed by a subgroup analysis according to the clinical severity of maternal COVID-19. RESULTS: The estimated viral load in maternal nasopharynx is not significantly associated with gestational age at birth (adjusted B: -0.008 (95%CI: -0.04; 0.02); p = 0.889), birth weight (adjusted B: 4.29 (95%CI: -25; 35); p = 0.889), weight Z-score (adjusted B: -0.01 (95%CI: -0.03; 1); p = 0.336), 5' Apgar scores (adjusted B: -0. -9.8e-4 (95%CI: -0.01; 0.01); p = 0.889), prematurity (adjusted OR: -0.97 (95%CI: 0.93; 1.03); p = 0.766) and the small for gestational age status (adjusted OR: 1.03 (95%CI: 0.99; 1.07); p = 0.351). Similar results were obtained in subgroup analyses according to COVID-19 clinical severity. CONCLUSIONS: The estimated maternal nasopharyngeal viral load in pregnant women affected by COVID-19 during the third trimester is not associated with main perinatal outcomes.


Asunto(s)
COVID-19 , Complicaciones Infecciosas del Embarazo , Recién Nacido , Embarazo , Femenino , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , Complicaciones Infecciosas del Embarazo/diagnóstico , Estudios de Cohortes , Estudios Retrospectivos
6.
Front Med (Lausanne) ; 9: 1034288, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36523781

RESUMEN

Background: Systemic biomarkers for severity of SARS-CoV-2 infection are of great interest. In this study, we evaluated a set of collagen metabolites and extracellular matrix remodeling biomarkers including procollagen type III amino terminal propeptide (PIIINP), tissue inhibitor of metalloproteinases 1 (TIMP-1) and hyaluronic acid (HA) as prognostic indicators in COVID-19 patients. Methods: Ninety COVID-19 patients with the absence of chronic liver diseases were enrolled. Serum PIIINP, TIMP-1, and HA were measured and correlated with inflammatory indices and clinical variables. Patients were stratified for disease severity according to WHO criteria in two groups, based on the requirement of oxygen support. Results: Serum TIMP-1, but not PIIINP and HA was significantly higher in patients with WHO score ≥5 compared to patients with WHO score <5 [PIIINP: 7.2 (5.4-9.5) vs. 7.1 (4.5-9.9), p = 0.782; TIMP-1: 298.1 (20.5-460) vs. 222.2 (28.5-452.8), p = 0.01; HA: 117.1 (55.4-193.7) vs. 75.1 (36.9-141.8), p = 0.258]. TIMP-1 showed moderate correlation with CRP (r = 0.312, p = 0.003) and with LDH (r = 0.263, p = 0.009). CRP and serum LDH levels were significantly higher in COVID-19 patients with WHO score ≥5 compared to the group of patients with WHO score < 5 [15.8 (9-44.5) vs. 9.3 (3.4-33.8), p = 0.039 and 373 (282-465) vs. 289 (218-383), p = 0.013, respectively]. Conclusion: In patients with COVID-19, circulating TIMP-1 was associated with disease severity and with systemic inflammatory index, suggesting that TIMP-1 could represent a promising non-invasive prognostic biomarker in COVID-19 patients. Interestingly, our results prompted that serum TIMP-1 level may potentially be used to select the patients for therapeutic approaches targeting matrix metalloproteases pathway.

7.
Prostate ; 82(15): 1469-1476, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35971798

RESUMEN

OBJECTIVES: Prostate health index (PHI) and, more recently, Proclarix have been proposed as serum biomarkers for prostate cancer (PCa). In this study, we aimed to evaluate Proclarix and PHI for predicting clinically significant prostate cancer (csPCa). PATIENTS AND METHODS: Proclarix and PHI were measured using samples of 344 men from two different centers. All patients underwent prostate biopsy, and among those, 188 men with PCa on biopsy had an additional radical prostatectomy (RP). All men had a prostate-specific antigen (PSA) between 2 and 10 ng/ml. Evaluation of area under the curve (AUC) and performance at predefined cut-offs of Proclarix and PHI risk scores as well as the linear combination thereof was performed to predict csPCa. PSA density was used as an independent comparator. RESULTS: The cohort median age and PSA were 65 (interquartile range [IQR]: 60-71) and 5.6 (IQR: 4.3-7.2) ng/ml, respectively. CsPCa was diagnosed in 161 (47%) men based on the RP specimen. ROC analysis showed that Proclarix and PHI accurately predicted csPCa with no significant difference (AUC of 0.79 and 0.76, p = 0.378) but significantly better when compared to PSA density (AUC of 0.66, p < 0.001). When using specific cut-offs, Proclarix (cut-off 10) revealed higher specificity and positive predictive value than PHI (cut-off 27) at similar sensitivities. The combination of Proclarix and PHI provided a significant increase in the AUC (p ≤ 0.007) compared to the individual tests alone and the highest clinical benefit was achieved. CONCLUSION: Results of this study show that both Proclarix and PHI accurately detect the presence of csPCa. The model combining Proclarix and PHI revealed the synergistic effect and improved the diagnostic performance of the individual tests.


Asunto(s)
Antígeno Prostático Específico , Neoplasias de la Próstata , Humanos , Masculino , Estudios Prospectivos , Próstata/patología , Prostatectomía , Neoplasias de la Próstata/diagnóstico , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía
8.
Genome Med ; 14(1): 90, 2022 08 12.
Artículo en Inglés | MEDLINE | ID: mdl-35962405

RESUMEN

BACKGROUND: Genomic surveillance of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the only approach to rapidly monitor and tackle emerging variants of concern (VOC) of the COVID-19 pandemic. Such scrutiny is crucial to limit the spread of VOC that might escape the immune protection conferred by vaccination strategies or previous virus exposure. It is also becoming clear now that efficient genomic surveillance would require monitoring of the host gene expression to identify prognostic biomarkers of treatment efficacy and disease progression. Here we propose an integrative workflow to both generate thousands of SARS-CoV-2 genome sequences per week and analyze host gene expression upon infection. METHODS: In this study we applied an integrated workflow for RNA extracted from nasal swabs to obtain in parallel the full genome of SARS-CoV-2 and transcriptome of host respiratory epithelium. The RNA extracted from each sample was reverse transcribed and the viral genome was specifically enriched through an amplicon-based approach. The very same RNA was then used for patient transcriptome analysis. Samples were collected in the Campania region, Italy, for viral genome sequencing. Patient transcriptome analysis was performed on about 700 samples divided into two cohorts of patients, depending on the viral variant detected (B.1 or delta). RESULTS: We sequenced over 20,000 viral genomes since the beginning of the pandemic, producing the highest number of sequences in Italy. We thus reconstructed the pandemic dynamics in the regional territory from March 2020 to December 2021. In addition, we have matured and applied novel proof-of-principle approaches to prioritize possible gain-of-function mutations by leveraging patients' metadata and isolated patient-specific signatures of SARS-CoV-2 infection. This allowed us to (i) identify three new viral variants that specifically originated in the Campania region, (ii) map SARS-CoV-2 intrahost variability during long-term infections and in one case identify an increase in the number of mutations in the viral genome, and (iii) identify host gene expression signatures correlated with viral load in upper respiratory ways. CONCLUSION: In conclusion, we have successfully generated an optimized and cost-effective strategy to monitor SARS-CoV-2 genetic variability, without the need of automation. Thus, our approach is suitable for any lab with a benchtop sequencer and a limited budget, allowing an integrated genomic surveillance on premises. Finally, we have also identified a gene expression signature defining SARS-CoV-2 infection in real-world patients' upper respiratory ways.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/genética , Genoma Viral , Humanos , Pandemias , ARN , SARS-CoV-2/genética
9.
J Transl Med ; 19(1): 246, 2021 06 05.
Artículo en Inglés | MEDLINE | ID: mdl-34090468

RESUMEN

BACKGROUND: Since the first complete genome sequencing of SARS-CoV-2 in December 2019, more than 550,000 genomes have been submitted into the GISAID database. Sequencing of the SARS-CoV-2 genome might allow identification of variants with increased contagiousness, different clinical patterns and/or different response to vaccines. A highly automated next generation sequencing (NGS)-based method might facilitate an active genomic surveillance of the virus. METHODS: RNA was extracted from 27 nasopharyngeal swabs obtained from citizens of the Italian Campania region in March-April 2020 who tested positive for SARS-CoV-2. Following viral RNA quantification, sequencing was performed using the Ion AmpliSeq SARS-CoV-2 Research Panel on the Genexus Integrated Sequencer, an automated technology for library preparation and sequencing. The SARS-CoV-2 complete genomes were built using the pipeline SARS-CoV-2 RECoVERY (REconstruction of COronaVirus gEnomes & Rapid analYsis) and analysed by IQ-TREE software. RESULTS: The complete genome (100%) of SARS-CoV-2 was successfully obtained for 21/27 samples. In particular, the complete genome was fully sequenced for all 15 samples with high viral titer (> 200 copies/µl), for the two samples with a viral genome copy number < 200 but greater than 20, and for 4/10 samples with a viral load < 20 viral copies. The complete genome sequences classified into the B.1 and B.1.1 SARS-CoV-2 lineages. In comparison to the reference strain Wuhan-Hu-1, 48 total nucleotide variants were observed with 26 non-synonymous substitutions, 18 synonymous and 4 reported in untranslated regions (UTRs). Ten of the 26 non-synonymous variants were observed in ORF1ab, 7 in S, 1 in ORF3a, 2 in M and 6 in N genes. CONCLUSIONS: The Genexus system resulted successful for SARS-CoV-2 complete genome sequencing, also in cases with low viral copies. The use of this highly automated system might facilitate the standardization of SARS-CoV-2 sequencing protocols and make faster the identification of novel variants during the pandemic.


Asunto(s)
COVID-19 , SARS-CoV-2 , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Italia , Secuenciación Completa del Genoma
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...