Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Int J Mol Sci ; 25(8)2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38673834

RESUMEN

In this paper, the in vivo behavior of orthopedic implants covered with thin films obtained by matrix-assisted pulsed laser evaporation and containing bioactive glass, a polymer, and natural plant extract was evaluated. In vivo testing was performed by carrying out a study on guinea pigs who had coated metallic screws inserted in them and also controls, following the regulations of European laws regarding the use of animals in scientific studies. After 26 weeks from implantation, the guinea pigs were subjected to X-ray analyses to observe the evolution of osteointegration over time; the guinea pigs' blood was collected for the detection of enzymatic activity and to measure values for urea, creatinine, blood glucose, alkaline phosphatase, pancreatic amylase, total protein, and glutamate pyruvate transaminase to see the extent to which the body was affected by the introduction of the implant. Moreover, a histopathological assessment of the following vital organs was carried out: heart, brain, liver, and spleen. We also assessed implanted bone with adjacent tissue. Our studies did not find significant variations in biochemical and histological results compared to the control group or significant adverse effects caused by the implant coating in terms of tissue compatibility, inflammatory reactions, and systemic effects.


Asunto(s)
Extractos Vegetales , Animales , Cobayas , Extractos Vegetales/química , Extractos Vegetales/farmacología , Nanoestructuras/química , Materiales Biocompatibles/química , Ensayo de Materiales , Vidrio/química , Prótesis e Implantes , Masculino , Oseointegración/efectos de los fármacos
2.
Nanomaterials (Basel) ; 10(2)2020 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-32098412

RESUMEN

Aseptic loosening and periprosthetic infections are the main causes of implant failure. Strategies to mitigate this drawback are therefore mandatory to avoid primary and revision replacement surgeries. A functional bioapatite-biopolymer double nanostructure fabricated by matrix-assisted pulsed laser evaporation to prevent infection of orthopedic and dental implants could promote osseointegration and ensure controlled delivery of natural antimicrobial drugs. The synthesized nanostructure consists of two overlapping layers, the lower from a biocompatible polymer for anticorrosive protection, and the upper of bioactive glass incorporating antimicrobial plant extract, acting as a potential drug delivery system. Morphology, composition, adherence, ability for drug delivery and biological properties (cytotoxicity and antimicrobial effect) were studied. Structures proved compact and stable, conserving a remarkable drug delivery ability for more than 21 days, i.e., enough to ensure long-term microbes' eradication.

3.
Sci Total Environ ; 672: 129-140, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-30954811

RESUMEN

Polyphenols are important to human health thus making it interesting and necessary to identify and assess methods for their detection. Gallic acid (GA) is a well-known antioxidant compound, found in tea leaves, various fruits, fruit seeds and in fruit-derived foods and beverages. In this study, to electrochemically detect this compound and assess the potential for GA detection, different analytical conditions at pH values of 5.8, 7 and 8 were tried. Two types of device were used for GA detection: (1) Lazar ORP-146C reduction-oxidation microsensors, coupled with a Jenco device, for estimation of antioxidant capacities of different electroactive media, and (2) screen-printed carbon sensors coupled with a mobile PalmSens device using differential pulse voltammetry (qualitative and quantitative GA determination). These proposed methods were validated by analysing some real samples: wine, green tea, apple juice and serum fortified with GA. Detection was evaluated in terms of specific calibration curves, with low limit of detection (LOD) and limit of quantification (LOQ), low response time, and high sensitivities. The analytical characteristics obtained recommend these methods to be tested on more other types of real samples. Our proposed methods, used in the established conditions of pH, may have further application in other clinical, food or environmental samples analyses in which the results of total antioxidants contents are usually expressed in GA equivalents.


Asunto(s)
Técnicas Electroquímicas/métodos , Ácido Gálico/análisis , Monitoreo del Ambiente , Análisis de los Alimentos , Límite de Detección
4.
Sci Total Environ ; 656: 709-716, 2019 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-30530140

RESUMEN

Persistent organochlorine pollutants (POPs) are highly lipophilic and resistant to degradation, hence these substances are commonly found in the environment even decades after their prohibition. The aim of the present study was to determine human serum concentrations of POPs and polycyclic aromatic hydrocarbons (PAHs) in the Romanian population, investigating the role of demographic variables on the body burden of such chemicals. A cross-sectional study including a total of 121 subjects from Brasov (Transylvania region) was designed. The concentration of 62 chemicals, including organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (BDEs) and PAHs, was measured by gas chromatography-mass spectrometry (GC-MS) in the serum of the participants. p,p'-DDE and ß-HCH were detected in 100% and 62% of the series (median values = 2.1 and 0.5 µg/L); PCB-153 was detected in 77.7% of the subjects and PCB-28 showed the highest median concentration (0.5 µg/L); BDE-47 was detected at a low concentration in 11.6% of the individuals; phenanthrene and naphthalene were present in 98.3% and 38.8% of the serum samples (median values = 0.9 and 6.5 µg/L, respectively). Age was the main determinant of the total body burden of OCPs and PCBs. A positive correlation was observed between p,p'-DDE and age (Spearman Rho = 0.312, P < 0.0001), suggesting the prevalence of higher levels of pollutants at older ages. The present results showed a significant decrease in serum levels of p,p'-DDE and HCH in Romania -a country which has traditionally reported higher values than other Eastern European countries- as well as low levels of PCBs and BDEs. The presence of PAHs suggests an unknown source of exposure that deserves further investigation.


Asunto(s)
Exposición a Riesgos Ambientales , Contaminantes Ambientales/sangre , Éteres Difenilos Halogenados/sangre , Plaguicidas/sangre , Bifenilos Policlorados/sangre , Hidrocarburos Policíclicos Aromáticos/sangre , Adulto , Factores de Edad , Índice de Masa Corporal , Estudios Transversales , Monitoreo del Ambiente , Femenino , Humanos , Hidrocarburos Clorados/sangre , Masculino , Persona de Mediana Edad , Características de la Residencia , Rumanía , Factores Sexuales , Adulto Joven
5.
Environ Res ; 166: 269-275, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29908458

RESUMEN

Smoking is considered an important source for inorganic elements, most of them toxic for human health. During the last years, there has been a significant increase in the use of e-cigarettes, although the role of them as source of inorganic elements has not been well established. A cross-sectional study including a total of 150 subjects from Brasov (Romania), divided into three groups (non-smokers, cigarette smokers and electronic cigarettes smokers) were recruited to disclose the role of smoking on the human exposure to inorganic elements. Concentration of 42 elements, including trace elements, elements in the ATSDR's priority pollutant list and rare earth elements (REE) were measured by ICP-MS in the blood serum of participants. Cigarette smokers showed the highest levels of copper, molybdenum, zinc, antimony, and strontium. Electronic cigarette (e-cigarette) users presented the highest concentrations of selenium, silver, and vanadium. Beryllium, europium and lanthanides were detected more frequently among e-cigarette users (20.6%, 23.5%, and 14.7%) than in cigarette smokers (1.7%, 19.0%, and 12.1%, respectively); and the number of detected REE was also higher among e-cigarette users (11.8% of them showed more than 10 different elements). Serum levels of cerium and erbium increased as the duration of the use of e-cigarettes was longer. We have found that smoking is mainly a source of heavy metals while the use of e-cigarettes is a potential source of REE. However, these elements were detected at low concentrations.


Asunto(s)
Carga Corporal (Radioterapia) , Sistemas Electrónicos de Liberación de Nicotina , Metales Pesados/sangre , Metales de Tierras Raras/sangre , No Fumadores , Fumadores , Estudios Transversales , Humanos , Rumanía , Oligoelementos/sangre
6.
PLoS One ; 11(7): e0160021, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27467684

RESUMEN

Ochratoxin A (OTA)-a toxin produced by Aspergillus carbonarius, Aspergillus ochraceus, and Penicillium verrucosum-is one of the most-abundant food-contaminating mycotoxins. To avoid the risk of OTA consumption for humans and animals, the rapid detection and quantitation of OTA level in different commodities are of great importance. In this work, an impedimetric immunosensor for ochratoxin A (OTA) detection, a common toxic botanical contaminant, was developed via the immobilization of anti-OTA antibody on bovine serum albumin modified gold electrodes. A four-step reaction protocol was tested to modify the gold electrode and obtain the sensing substrate. All the steps of the immunosensor elaboration and also the immunochemical reaction between surface-bound antibody and ochratoxin A were analyzed using cyclic voltammetry and electrochemical impedance spectroscopy. Modification of the impedance due to the specific antigen-antibody reaction at immunosensor surface, was used in order to detect ochratoxin A. Linear proportionality of the charge transfer resistance to the concentration of OTA allows ochratoxin A detection in the range of 2.5-100 ng/mL.


Asunto(s)
Anticuerpos/inmunología , Electrodos , Oro/química , Micotoxinas/análisis , Ocratoxinas/análisis , Albúmina Sérica Bovina/química , Técnicas Biosensibles , Sensibilidad y Especificidad
7.
Molecules ; 21(6)2016 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-27294895

RESUMEN

In this work we try to address the large interest existing nowadays in the better understanding of the interaction between microbial biofilms and metallic implants. Our aimed was to identify a new preventive strategy to control drug release, biofilm formation and contamination of medical devices with microbes. The transfer and printing of novel bioactive glass-polymer-antibiotic composites by Matrix-Assisted Pulsed Laser Evaporation into uniform thin films onto 316 L stainless steel substrates of the type used in implants are reported. The targets were prepared by freezing in liquid nitrogen mixtures containing polymer and antibiotic reinforced with bioglass powder. The cryogenic targets were submitted to multipulse evaporation by irradiation with an UV KrF* (λ = 248 nm, τFWHM ≤ 25 ns) excimer laser source. The prepared structures were analyzed by infrared spectroscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy and profilometry, before and after immersion in physiological fluids. The bioactivity and the release of the antibiotic have been evaluated. We showed that the incorporated antibiotic underwent a gradually dissolution in physiological fluids thus supporting a high local treatment efficiency. Electrochemical measurements including linear sweep voltammetry and impedance spectroscopy studies were carried out to investigate the corrosion resistance of the coatings in physiological environments. The in vitro biocompatibility assay using the MG63 mammalian cell line revealed that the obtained nanostructured composite films are non-cytotoxic. The antimicrobial effect of the coatings was tested against Staphylococcus aureus and Escherichia coli strains, usually present in implant-associated infections. An anti-biofilm activity was evidenced, stronger against E. coli than the S. aureus strain. The results proved that the applied method allows for the fabrication of implantable biomaterials which shield metal ion release and possess increased biocompatibility and resistance to microbial colonization and biofilm growth.


Asunto(s)
Antiinfecciosos/química , Biopelículas/efectos de los fármacos , Materiales Biocompatibles Revestidos/química , Prótesis e Implantes/microbiología , Antibacterianos/química , Antibacterianos/uso terapéutico , Antiinfecciosos/uso terapéutico , Biopelículas/crecimiento & desarrollo , Cerámica/química , Cerámica/uso terapéutico , Materiales Biocompatibles Revestidos/uso terapéutico , Escherichia coli/efectos de los fármacos , Humanos , Microscopía Electrónica de Rastreo , Impresión , Acero Inoxidable/química , Staphylococcus aureus/efectos de los fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA