Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 12 de 12
1.
ACS Sens ; 8(6): 2228-2236, 2023 06 23.
Article En | MEDLINE | ID: mdl-37279466

Point-of-care tests (POCTs) are increasingly being used in field settings, particularly outdoors. The performance of current POCTs─most commonly the lateral flow immunoassay─can be adversely affected by ambient temperature and humidity. We developed a self-contained immunoassay platform─the D4 POCT─that can be conducted at the POC by integrating all reagents in a capillary-driven passive microfluidic cassette that minimizes user intervention. The assay can be imaged and analyzed on a portable fluorescence reader─the D4Scope─and provide quantitative outputs. Here, we systematically investigated the resilience of our D4 POCT to varied temperature and humidity and to physiologically diverse human whole blood samples that span a wide range of physiological hematocrit (30-65%). For all conditions, we showed that the platform maintained high sensitivity (0.05-0.41 ng/mL limits of detection). The platform also demonstrated good accuracy in reporting true analyte concentration across environmental extremes when compared to the manually operated format of the same test to detect a model analyte─ovalbumin. Additionally, we engineered an improved version of the microfluidic cassette that improved the ease-of-use of the device and shortened the time-to-result. We implemented this new cassette to create a rapid diagnostic test to detect talaromycosis infection in patients with advanced HIV disease at the POC, demonstrating comparable sensitivity and specificity to the laboratory test for the disease.


Microfluidics , Point-of-Care Systems , Humans , Point-of-Care Testing , Immunoassay
2.
Anal Chem ; 95(13): 5610-5617, 2023 04 04.
Article En | MEDLINE | ID: mdl-36961989

Antigen tests to detect SARS-CoV-2 have emerged as a promising rapid diagnostic method for COVID-19, but they are unable to differentiate between variants of concern (VOCs). Here, we report a rapid point-of-care test (POC-T), termed CoVariant-SPOT, that uses a set of antibodies that are either tolerant or intolerant to spike protein mutations to identify the likely SARS-CoV-2 strain concurrent with COVID-19 diagnosis using antibodies targeting the nucleocapsid protein. All reagents are incorporated into a portable, multiplexed, and sensitive diagnostic platform built upon a nonfouling polymer brush. To validate CoVariant-SPOT, we tested recombinant SARS-CoV-2 proteins, inactivated viruses, and nasopharyngeal swab samples from COVID-19 positive and negative individuals and showed that CoVariant-SPOT can readily distinguish between two VOCs: Delta and Omicron. We believe that CoVariant-SPOT can serve as a valuable adjunct to next-generation sequencing to rapidly identify variants using a scalable and deployable POC-T, thereby enhancing community surveillance efforts worldwide and informing treatment selection.


COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , Point-of-Care Systems , COVID-19 Testing , Antibodies
3.
Methods Mol Biol ; 2393: 343-365, 2022.
Article En | MEDLINE | ID: mdl-34837189

Sandwich immunoassays are the gold standard for detection of protein analytes. Here, we describe an ultrasensitive point-of-care sandwich immunoassay platform for the detection of biomarkers directly from blood or serum using a custom-built smartphone detector. Testing undiluted blood or serum is challenging due to the complexity of the matrix. Proteins nonspecifically adsorb to and cells often adhere to the assay surface, which can drastically impact the analytical sensitivity of the assay. To address this problem, our assay is built upon a "nonfouling" polymer brush "grafted from" a glass slide, which eliminates nearly all nonspecific binding and therefore increases the signal-to-noise ratio and greatly improves the analytical performance of the test. The two components required to perform a sandwich immunoassay are inkjet-printed directly onto the surface: (1) "stable" capture antibodies that remain entrapped in the brush even after exposure to a liquid sample and (2) fluorescently labeled "soluble" detection antibodies that dissolve upon exposure to a liquid sample. The polymer brush provides hydration to the antibodies, allowing them to remain stable and active over prolonged periods of time. When a liquid sample containing a biomarker of interest is dispensed onto the chip, the detection antibodies dissolve and diffuse to the stable capture spots forming a complex that sandwiches the analyte and that has a fluorescence intensity proportional to the concentration of the biomarker in solution, which can be measured using a custom-built smartphone detector. As multiple capture antibodies can be printed as discrete capture spots, the assay can be easily multiplexed without the need for multiple fluorophores. This chip and detector platform can be utilized for the point-of-care detection of low-abundance biomarkers directly from blood or serum in low-resource settings.


Point-of-Care Systems , Smartphone , Antibodies , Biomarkers , Immunoassay , Polymers
4.
Sci Adv ; 7(26)2021 06.
Article En | MEDLINE | ID: mdl-34172447

Highly sensitive, specific, and point-of-care (POC) serological assays are an essential tool to manage coronavirus disease 2019 (COVID-19). Here, we report on a microfluidic POC test that can profile the antibody response against multiple severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigens-spike S1 (S1), nucleocapsid (N), and the receptor binding domain (RBD)-simultaneously from 60 µl of blood, plasma, or serum. We assessed the levels of antibodies in plasma samples from 31 individuals (with longitudinal sampling) with severe COVID-19, 41 healthy individuals, and 18 individuals with seasonal coronavirus infections. This POC assay achieved high sensitivity and specificity, tracked seroconversion, and showed good concordance with a live virus microneutralization assay. We can also detect a prognostic biomarker of severity, IP-10 (interferon-γ-induced protein 10), on the same chip. Because our test requires minimal user intervention and is read by a handheld detector, it can be globally deployed to combat COVID-19.


COVID-19 Serological Testing/methods , COVID-19/diagnosis , Point-of-Care Testing , SARS-CoV-2/immunology , Antibodies, Viral/blood , Antibodies, Viral/immunology , COVID-19/blood , COVID-19/virology , COVID-19 Serological Testing/instrumentation , Humans , Reproducibility of Results , SARS-CoV-2/metabolism , SARS-CoV-2/physiology , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus/immunology , Spike Glycoprotein, Coronavirus/metabolism
5.
Sci Transl Med ; 13(588)2021 04 07.
Article En | MEDLINE | ID: mdl-33827978

Ebola virus (EBOV) hemorrhagic fever outbreaks have been challenging to deter due to the lack of health care infrastructure in disease-endemic countries and a corresponding inability to diagnose and contain the disease at an early stage. EBOV vaccines and therapies have improved disease outcomes, but the advent of an affordable, easily accessed, mass-produced rapid diagnostic test (RDT) that matches the performance of more resource-intensive polymerase chain reaction (PCR) assays would be invaluable in containing future outbreaks. Here, we developed and demonstrated the performance of a new ultrasensitive point-of-care immunoassay, the EBOV D4 assay, which targets the secreted glycoprotein of EBOV. The EBOV D4 assay is 1000-fold more sensitive than the U.S. Food and Drug Administration-approved RDTs and detected EBOV infection earlier than PCR in a standard nonhuman primate model. The EBOV D4 assay is suitable for low-resource settings and may facilitate earlier detection, containment, and treatment during outbreaks of the disease.


Hemorrhagic Fever, Ebola , Point-of-Care Systems , Animals , Ebolavirus , Glycoproteins , Hemorrhagic Fever, Ebola/diagnosis , Immunoassay , Polymerase Chain Reaction
6.
medRxiv ; 2020 Nov 07.
Article En | MEDLINE | ID: mdl-33173900

Highly sensitive, specific, and point-of-care (POC) serological assays are an essential tool to manage the COVID-19 pandemic. Here, we report on a microfluidic, multiplexed POC test that can profile the antibody response against multiple SARS-CoV-2 antigens - Spike S1 (S1), Nucleocapsid (N), and the receptor binding domain (RBD) - simultaneously from a 60 microliter drop of blood, plasma, or serum. We assessed the levels of anti-SARS-CoV-2 antibodies in plasma samples from 19 individuals (at multiple time points) with COVID-19 that required admission to the intensive care unit and from 10 healthy individuals. This POC assay shows good concordance with a live virus microneutralization assay, achieved high sensitivity (100%) and specificity (100%), and successfully tracked the longitudinal evolution of the antibody response in infected individuals. We also demonstrated that we can detect a chemokine, IP-10, on the same chip, which may provide prognostic insight into patient outcomes. Because our test requires minimal user intervention and is read by a handheld detector, it can be globally deployed in the fight against COVID-19 by democratizing access to laboratory quality tests.

7.
Nano Lett ; 20(6): 4330-4336, 2020 06 10.
Article En | MEDLINE | ID: mdl-32375003

Fluorescence-based microarrays are promising diagnostic tools due to their high throughput, small sample volume requirements, and multiplexing capabilities. However, their low fluorescence output has limited their implementation for in vitro diagnostics applications in point-of-care (POC) settings. Here, by integration of a sandwich immunoassay microarray within a plasmonic nanogap cavity, we demonstrate strongly enhanced fluorescence which is critical for readout by inexpensive POC detectors. The immunoassay consists of inkjet-printed antibodies on a polymer brush which is grown on a gold film. Colloidally synthesized silver nanocubes are placed on top and interact with the underlying gold film creating high local electromagnetic field enhancements. By varying the thickness of the brush from 5 to 20 nm, up to a 151-fold increase in fluorescence and 14-fold improvement in the limit-of-detection is observed for the cardiac biomarker B-type natriuretic peptide (BNP) compared to the unenhanced assay, paving the way for a new generation of POC clinical diagnostics.


Bioprinting , Gold , Immunoassay , Silver , Humans , Nanotechnology , Point-of-Care Testing , Polymers
8.
Adv Mater ; 32(2): e1903285, 2020 Jan.
Article En | MEDLINE | ID: mdl-31782843

"Nonfouling" polymer brush surfaces can greatly improve the performance of in vitro diagnostic (IVD) assays due to the reduction of nonspecific protein adsorption and consequent improvement of signal-to-noise ratios. The development of synthetic polymer brush architectures that suppress adventitious protein adsorption is reviewed, and their integration into surface plasmon resonance and fluorescent sandwich immunoassay formats is discussed. Also, highlighted is a novel, self-contained immunoassay platform (the D4 assay) that transforms time-consuming laboratory-based assays into a user-friendly and point-of-care format with a sensitivity and specificity comparable or better than standard enzyme-linked immunosorbent assay (ELISA) directly from unprocessed samples. These advancements clearly demonstrate the utility of nonfouling polymer brushes as a substrate for ultrasensitive and robust diagnostic assays that may be suitable for clinical testing, in field and laboratory settings.


Immunoassay/methods , Polymers/chemistry , Biofouling , Humans , Point-of-Care Testing
9.
Adv Healthc Mater ; 8(8): e1801177, 2019 04.
Article En | MEDLINE | ID: mdl-30908902

Poly(ethylene glycol) (PEG), a linear polymer known for its "stealth" properties, is commonly used to passivate the surface of biomedical implants and devices, and it is conjugated to biologic drugs to improve their pharmacokinetics. However, its antigenicity is a growing concern. Here, the antigenicity of PEG is investigated when assembled in a poly(oligoethylene glycol) methacrylate (POEGMA) "bottlebrush" configuration on a planar surface. Using ethylene glycol (EG) repeat lengths of the POEGMA sidechains as a tunable parameter for optimization, POEGMA brushes with sidechain lengths of two and three EG repeats are identified as the optimal polymer architecture to minimize binding of anti-PEG antibodies (APAs), while retaining resistance to nonspecific binding by bovine serum albumin and cultured cells. Binding of backbone- versus endgroup-selective APAs to POEGMA brushes is further investigated, and finally the antigenicity of POEGMA coatings is assessed against APA-positive clinical plasma samples. These results are applied toward fabricating immunoassays on POEGMA surfaces with minimal reactivity toward APAs while retaining a low limit-of-detection for the analyte. Taken together, these results offer useful design concepts to reduce the antigenicity of polymer brush-based surface coatings used in applications involving human or animal matrices.


Antigens , Coated Materials, Biocompatible , Polyethylene Glycols , Animals , Antibodies/analysis , Antibodies/metabolism , Antigens/chemistry , Antigens/immunology , Antigens/metabolism , Antigens/ultrastructure , Coated Materials, Biocompatible/adverse effects , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/metabolism , Mice , NIH 3T3 Cells , Polyethylene Glycols/chemistry , Polyethylene Glycols/metabolism , Prostheses and Implants , Serum Albumin, Bovine/chemistry , Serum Albumin, Bovine/metabolism , Surface Properties
10.
Langmuir ; 35(5): 1379-1390, 2019 02 05.
Article En | MEDLINE | ID: mdl-30086642

Motivated by the lack of adventitious protein adsorption on zwitterionic polymer brushes that promise low noise and hence high analytical sensitivity for surface-based immunoassays, we explored their use as a substrate for immunoassay fabrication by the inkjet printing of antibodies. We observed that a poly(sulfobetaine)methacrylate brush on glass is far too hydrophilic to enable the noncovalent immobilization of antibodies by inkjet printing. To circumvent this limitation, we developed a series of hybrid zwitterionic-cationic surface coatings with tunable surface wettability that are suitable for the inkjet printing of antibodies but also have low protein adsorption. We show that in a microarray format in which both the capture and detection antibodies are discretely printed as spots on these hybrid brushes, a point-of-care sandwich immunoassay can be carried out with an analytical sensitivity and dynamic range that is similar to or better than those of the same assay fabricated on a PEG-like brush. We also show that the hybrid polymer brushes do not bind anti-PEG antibodies that are ubiquitous in human blood, which can be a problem with immunoassays fabricated on PEG-like coatings.


Immunoassay/methods , Methacrylates/chemistry , Animals , Antibodies, Immobilized/immunology , Cattle , Humans , Interleukin-6/blood , Interleukin-6/immunology , Methacrylates/chemical synthesis , Point-of-Care Testing , Printing/instrumentation , Rabbits , Wettability
11.
Proc Natl Acad Sci U S A ; 114(34): E7054-E7062, 2017 08 22.
Article En | MEDLINE | ID: mdl-28784765

The ELISA is the mainstay for sensitive and quantitative detection of protein analytes. Despite its utility, ELISA is time-consuming, resource-intensive, and infrastructure-dependent, limiting its availability in resource-limited regions. Here, we describe a self-contained immunoassay platform (the "D4 assay") that converts the sandwich immunoassay into a point-of-care test (POCT). The D4 assay is fabricated by inkjet printing assay reagents as microarrays on nanoscale polymer brushes on glass chips, so that all reagents are "on-chip," and these chips show durable storage stability without cold storage. The D4 assay can interrogate multiple analytes from a drop of blood, is compatible with a smartphone detector, and displays analytical figures of merit that are comparable to standard laboratory-based ELISA in whole blood. These attributes of the D4 POCT have the potential to democratize access to high-performance immunoassays in resource-limited settings without sacrificing their performance.


Blood Chemical Analysis/methods , Immunoassay/methods , Polymers/chemistry , Biomarkers/blood , Blood Chemical Analysis/instrumentation , Equipment Design , Humans , Immunoassay/instrumentation , Immunoglobulin G/blood , Immunoglobulin M/blood , Leptin/blood , Point-of-Care Systems , Printing
12.
ACS Appl Mater Interfaces ; 9(6): 5522-5529, 2017 Feb 15.
Article En | MEDLINE | ID: mdl-28117566

Advances in electronics and life sciences have generated interest in "lab-on-a-chip" systems utilizing complementary metal oxide semiconductor (CMOS) circuitry for low-power, portable, and cost-effective biosensing platforms. Here, we present a simple and reliable approach for coating "high-κ" metal oxide dielectric materials with "non-fouling" (protein- and cell-resistant) poly(oligo(ethylene glycol) methyl ether methacrylate (POEGMA) polymer brushes as biointerfacial coatings to improve their relevance for biosensing applications utilizing advanced electronic components. By using a surface-initiated "grafting from" strategy, POEGMA films were reliably grown on each material, as confirmed by ellipsometric measurements and X-ray photoelectron spectroscopy (XPS) analysis. The electrical behavior of these POEGMA films was also studied to determine the potential impact on surrounding electronic devices, yielding information on relative permittivity and breakdown field for POEGMA in both dry and hydrated states. We show that the incorporation of POEGMA coatings significantly reduced levels of nonspecific protein adsorption compared to uncoated high-κ dielectric oxide surfaces as shown by protein resistance assays. These attributes, combined with the robust dielectric properties of POEGMA brushes on high-κ surfaces open the way to incorporate this protein and cell resistant polymer interface into CMOS devices for biomolecular detection in a complex liquid milieu.

...