1.
Heliyon ; 10(13): e33497, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39040322

RESUMEN

This study aimed to develop a low-fructose (<3 g/serve) carbohydrate (CHO) gel for athletes. Various prototypes with 30 g CHO/serve and differing water content (12 %, 21 %, 32 %, 39 % w/v) were created and evaluated for sensory attributes. The final gel contained 62.1 ± 0.2 g CHO/100 g with 0.17 % w/w fructose. Endurance athletes (n = 20) underwent a feeding-challenge protocol, ingesting 30 g gel every 20 min during 2 h of running (60 % V ˙ O2max), followed by a 1 h self-paced distance test. Blood glucose increased significantly from baseline (4.0 ± 0.9 vs. 6.6 ± 0.6 mmol/L, p < 0.001) and remained elevated after the distance test (4.9 ± 0.7 mmol/L, p < 0.05). Breath hydrogen levels increased (5 ± 4 ppm, p < 0.05) without substantial CHO malabsorption detected. Gastrointestinal symptoms (GIS) increased during exercise but were mild. The low-fructose CHO gel demonstrated good tolerance, promoting glucose availability without severe GIS or CHO malabsorption.

2.
Foods ; 12(1)2022 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-36613219

RESUMEN

Determining cocoa bean quality is crucial for many players in the international supply chain. However, actual methods rely on a cut test protocol, which is limited by its subjective nature, or on time-consuming, expensive and destructive wet-chemistry laboratory procedures. In this context, the application of near infrared (NIR) spectroscopy, particularly with the recent developments of portable NIR spectrometers, may represent a valuable solution for providing a cocoa beans' quality profile, in a rapid, non-destructive, and reliable way. Monitored parameters in this work were dry matter (DM), ash, shell, fat, protein, total polyphenols, fermentation index (FI), titratable acidity (TA) and pH. Different chemometric analyses were performed on the spectral data and calibration models were developed using modified partial least squares regression. Prediction equations were validated using a fivefold cross-validation and a comparison between the different prediction performances for the portable and benchtop NIR spectrometers was provided. The NIRS benchtop instrument provided better performance of quantification considering the whole than the portable device, showing excellent prediction capability in protein and DM quantification. On the other hand, the NIRS portable device, although showing lower but valuable performance of prediction, can represent an appealing alternative to benchtop instruments for food business operators, being applicable in the field.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA