Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Virol ; 96(10): e0187521, 2022 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-35475668

RESUMEN

Persistent infection with some mucosal α-genus human papillomaviruses (HPVs; the most prevalent one being HPV16) can induce cervical carcinoma, anogenital cancers, and a subset of head and neck squamous cell carcinoma (HNSCC). Cutaneous ß-genus HPVs (such as HPV5 and HPV8) associate with skin lesions that can progress into squamous cell carcinoma with sun exposure in Epidermodysplasia verruciformis patients and immunosuppressed patients. Here, we analyzed mechanisms used by E6 proteins from the α- and ß-genus to inhibit the interferon-ß (IFNB1) response. HPV16 E6 mediates this effect by a strong direct interaction with interferon regulatory factor 3 (IRF3). The binding site of E6 was localized within a flexible linker between the DNA-binding domain and the IRF-activation domain of IRF3 containing an LxxLL motif. The crystallographic structure of the complex between HPV16 E6 and the LxxLL motif of IRF3 was solved and compared with the structure of HPV16 E6 interacting with the LxxLL motif of the ubiquitin ligase E6AP. In contrast, cutaneous HPV5 and HPV8 E6 proteins bind to the IRF3-binding domain (IBiD) of the CREB-binding protein (CBP), a key transcriptional coactivator in IRF3-mediated IFN-ß expression. IMPORTANCE Persistent HPV infections can be associated with the development of several cancers. The ability to persist depends on the ability of the virus to escape the host immune system. The type I interferon (IFN) system is the first-line antiviral defense strategy. HPVs carry early proteins that can block the activation of IFN-I. Among mucosal α-genus HPV types, the HPV16 E6 protein has a remarkable property to strongly interact with the transcription factor IRF3. Instead, cutaneous HPV5 and HPV8 E6 proteins bind to the IRF3 cofactor CBP. These results highlight the versatility of E6 proteins to interact with different cellular targets. The interaction between the HPV16 E6 protein and IRF3 might contribute to the higher prevalence of HPV16 than that of other high-risk mucosal HPV types in HPV-associated cancers.


Asunto(s)
Factor 3 Regulador del Interferón , Interferón beta , Proteínas Oncogénicas Virales , Infecciones por Papillomavirus , Proteínas Represoras , Papillomavirus Humano 16/metabolismo , Humanos , Factor 3 Regulador del Interferón/genética , Factor 3 Regulador del Interferón/metabolismo , Interferón beta/metabolismo , Membrana Mucosa/virología , Proteínas Oncogénicas Virales/genética , Proteínas Oncogénicas Virales/metabolismo , Papillomaviridae/metabolismo , Proteínas Represoras/genética , Proteínas Represoras/metabolismo , Piel/virología
2.
Cardiol Young ; 32(1): 101-105, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34709146

RESUMEN

BACKGROUND: Expert guidance from scientific societies and regulatory agencies recommend a framework of principles for frequency of in-person evaluations and remote monitoring for patients with cardiac implantable electronic devices. However, there are limited data regarding adherence to recommendations among paediatric electrophysiologists, and there are no data regarding cardiac implantable electronic device-related ancillary testing. METHODS: To assess current clinical practices for cardiac implantable electronic device in-person evaluation, remote monitoring, and cardiac implantable electronic device-related ancillary testing, the Paediatric and Congenital Electrophysiology Society members were surveyed. The main outcome measures were variations in frequency of in person evaluation, frequency of remote monitoring, and cardiac implantable electronic device-related ancillary testing. RESULTS: All respondents performed in-person evaluation at least once a year, but <50% of respondents performed an in-person evaluation within 2 weeks of cardiac implantable electronic device implantation. Remote monitoring was performed every 3 months for pacemakers and implantable cardioverter defibrillators by 71 and 75% respondents, respectively. Follow-up echocardiography was performed every 2-3 years by 53% respondents for patients with >50% ventricular pacing. Majority of respondents (75%) did not perform either an exercise stress test or ambulatory Holter monitoring or chest X-ray (65%) after cardiac implantable electronic device implantation. CONCLUSION: This survey identified significant practice variations in cardiac implantable electronic device in- person evaluation, remote monitoring, and ancillary testing practices among paediatric electrophysiologists. Cardiac implantable electronic device management may be optimised by development of a paediatric-specific guidelines for follow-up and ancillary testing.


Asunto(s)
Desfibriladores Implantables , Cardiopatías Congénitas , Marcapaso Artificial , Electrofisiología Cardíaca , Niño , Electrónica , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/terapia , Humanos , Encuestas y Cuestionarios
5.
JACC Clin Electrophysiol ; 7(11): 1437-1472, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34794667

RESUMEN

In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.


Asunto(s)
Cardiología , Desfibriladores Implantables , Adulto , American Heart Association , Niño , Electrónica , Humanos , América Latina , Estados Unidos
6.
Cardiol Young ; 31(11): 1738-1769, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34338183

RESUMEN

In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.


Asunto(s)
Cardiología , Desfibriladores Implantables , American Heart Association , Electrofisiología Cardíaca , Niño , Consenso , Electrónica , Humanos , Estados Unidos
7.
Genet Med ; 23(12): 2369-2377, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34341521

RESUMEN

PURPOSE: Pathogenic variants in GNPTAB and GNPTG, encoding different subunits of GlcNAc-1-phosphotransferase, cause mucolipidosis (ML) II, MLIII alpha/beta, and MLIII gamma. This study aimed to investigate the cellular and molecular bases underlying skeletal abnormalities in patients with MLII and MLIII. METHODS: We analyzed bone biopsies from patients with MLIII alpha/beta or MLIII gamma by undecalcified histology and histomorphometry. The skeletal status of Gnptgko and Gnptab-deficient mice was determined and complemented by biochemical analysis of primary Gnptgko bone cells. The clinical relevance of the mouse data was underscored by systematic urinary collagen crosslinks quantification in patients with MLII, MLIII alpha/beta, and MLIII gamma. RESULTS: The analysis of iliac crest biopsies revealed that bone remodeling is impaired in patients with GNPTAB-associated MLIII alpha/beta but not with GNPTG-associated MLIII gamma. Opposed to Gnptab-deficient mice, skeletal remodeling is not affected in Gnptgko mice. Most importantly, patients with variants in GNPTAB but not in GNPTG exhibited increased bone resorption. CONCLUSION: The gene-specific impact on bone remodeling in human individuals and in mice proposes distinct molecular functions of the GlcNAc-1-phosphotransferase subunits in bone cells. We therefore appeal for the necessity to classify MLIII based on genetic in addition to clinical criteria to ensure appropriate therapy.


Asunto(s)
Resorción Ósea , Mucolipidosis , Transferasas (Grupos de Otros Fosfatos Sustitutos) , Animales , Humanos , Ratones , Mucolipidosis/genética , Mucolipidosis/patología , Transferasas (Grupos de Otros Fosfatos Sustitutos)/genética
9.
Heart Rhythm ; 18(11): 1888-1924, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34363988

RESUMEN

In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.


Asunto(s)
Electrofisiología Cardíaca/normas , Desfibriladores Implantables , Técnicas de Diagnóstico Cardiovascular , Niño , Consenso , Remoción de Dispositivos , Diagnóstico por Imagen , Humanos , Estados Unidos
10.
Indian Pacing Electrophysiol J ; 21(6): 349-366, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34333142

RESUMEN

Guidelines for the implantation of cardiac implantable electronic devices (CIEDs) have evolved since publication of the initial ACC/AHA pacemaker guidelines in 1984 [1]. CIEDs have evolved to include novel forms of cardiac pacing, the development of implantable cardioverter defibrillators (ICDs) and the introduction of devices for long term monitoring of heart rhythm and other physiologic parameters. In view of the increasing complexity of both devices and patients, practice guidelines, by necessity, have become increasingly specific. In 2018, the ACC/AHA/HRS published Guidelines on the Evaluation and Management of Patients with Bradycardia and Cardiac Conduction Delay [2], which were specific recommendations for patients >18 years of age. This age-specific threshold was established in view of the differing indications for CIEDs in young patients as well as size-specific technology factors. Therefore, the following document was developed to update and further delineate indications for the use and management of CIEDs in pediatric patients, defined as ≤21 years of age, with recognition that there is often overlap in the care of patents between 18 and 21 years of age. This document is an abbreviated expert consensus statement (ECS) intended to focus primarily on the indications for CIEDs in the setting of specific disease/diagnostic categories. This document will also provide guidance regarding the management of lead systems and follow-up evaluation for pediatric patients with CIEDs. The recommendations are presented in an abbreviated modular format, with each section including the complete table of recommendations along with a brief synopsis of supportive text and select references to provide some context for the recommendations. This document is not intended to provide an exhaustive discussion of the basis for each of the recommendations, which are further addressed in the comprehensive PACES-CIED document [3], with further data easily accessible in electronic searches or textbooks.

11.
Indian Pacing Electrophysiol J ; 21(6): 367-393, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34333141

RESUMEN

In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.

12.
Channels (Austin) ; 5(4): 382-5, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21654198

RESUMEN

On September 12-15, 2010 the French Ion Channels Association organized its annual scientific meeting on the French coast of Mediterranean Sea. This meeting takes place in an attractive location and provides a great opportunity for principal investigators as well as young researchers to present and discuss their recent advances and future challenges in the field of ion channels and transporters. The French Ion Channels Association was created more than 20 years ago and its goal is to organize an annual meeting and more recently to promote interactions (through the website www.canaux-ioniques.fr) between active members of the international scientific community in the field of ion channels. In this report of the 21(st) edition of the meeting, we are summarizing the five main symposia that reflect original works and relevant developments in the domain of ions channels and transporters.


Asunto(s)
Canales Iónicos , Sociedades Científicas , Animales , Francia , Humanos
13.
Acta Orthop Belg ; 76(1): 86-9, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20306970

RESUMEN

This study looks at the changing incidence and aetiology of congenital talipes equinovarus due to the recent population changes within the area. Between 1st June 1992 and the 31st May 2006, 83 consecutive children (121 feet) born with fixed talipes equinovarus (TEV) were assessed and treated (an incidence of 1.6 per 1000 live births) in an observational longitudinal cohort study assessing associated factors. There were 17 syndromal cases in the fixed group (20.8%), 6 cases of non-syndromal distal arthrogryposis (7.2%), and a strong family history in 12 cases (14.5%). This study would suggest that genetic and primary causes of fixed TEV are more common than previously considered. Many of the primary aetiologies were diagnosed months or years after birth.


Asunto(s)
Pie Equinovaro/epidemiología , Anomalías Múltiples/epidemiología , Pie Equinovaro/etiología , Femenino , Humanos , Incidencia , Recién Nacido , Masculino , Reino Unido/epidemiología
14.
J Bone Joint Surg Am ; 91(12): 2915-21, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19952255

RESUMEN

BACKGROUND: The principal complications that follow the treatment of developmental dysplasia of the hip are redislocation and growth disturbance of the femoral head and neck as a result of osteonecrosis of the femoral epiphysis. Growth disturbance secondary to osteonecrosis is difficult to determine until long after the treatment episode has passed. Consequently, the treating surgeon has little early feedback regarding the long-term consequences of management interventions. We therefore sought to devise a quantitative method to identify early evidence of growth disturbance related to osteonecrosis. METHODS: The width and height of the epiphyses were measured on anteroposterior radiographs of the pelvis made twelve to eighteen months after successful closed reduction and on the latest available radiograph for each patient (mean age, 8.6 years). The epiphyseal index was calculated by dividing the height by the width. The radiographs were also scored for osteonecrosis with use of the Kalamchi and MacEwen classification system and were also assessed for sphericity with use of Mose rings. RESULTS: Forty-seven patients with late-presenting developmental dysplasia of the hip who subsequently underwent successful closed reduction were included. An index of <0.357 on the twelve to eighteen-month post-treatment radiograph strongly predicted the development of a nonspherical femoral head on the latest radiograph (sensitivity, 0.83; specificity, 0.95; positive predictive value, 0.55; and negative predictive value, 0.99). CONCLUSIONS: The height-to-width index appears to be a simple and quantifiable measurement of the severity of growth disturbance as a consequence of osteonecrosis following treatment for developmental dysplasia of the hip. It is predictive of asphericity at the time of intermediate-term follow-up and appears likely to predict asphericity at maturity, but this must be confirmed with follow-up to maturity. Unlike the currently used methods of assessing osteonecrosis, the index allows for the quantifiable evaluation of growth disturbance within a few years after the corrective procedure.


Asunto(s)
Necrosis de la Cabeza Femoral/diagnóstico por imagen , Necrosis de la Cabeza Femoral/fisiopatología , Cabeza Femoral/diagnóstico por imagen , Luxación Congénita de la Cadera/fisiopatología , Moldes Quirúrgicos , Niño , Femenino , Cabeza Femoral/patología , Necrosis de la Cabeza Femoral/etiología , Necrosis de la Cabeza Femoral/terapia , Luxación Congénita de la Cadera/complicaciones , Luxación Congénita de la Cadera/terapia , Humanos , Lactante , Masculino , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Radiografía
15.
J Pediatr Orthop ; 28(6): 640-7, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18724200

RESUMEN

INTRODUCTION: Correcting multiplanar lower-limb pediatric deformities requires complex and, in many cases, staged procedures. The Taylor-Spatial Frame (TSF) is a sophisticated external fixator system that can be used to treat simple to complex multiplanar and multiapical skeletal deformities. We describe its use in 53 children during the last 7 years in a variety of pathologies and demonstrate its ease of use and versatility. METHODS: A review of medical and physiotherapy records, radiographs, and computed tomographic scans of all patients treated with a TSF between June 1999 and December 2005 at the Booth Hall Children's Hospital was conducted. Data recorded were etiology of deformity, sex, age, number of previous operations, preoperative deformity parameters, operative records and frame constructs, treatment regime, frame duration, follow-up protocol, posttreatment deformity, complications, and clinical and radiological outcome. RESULTS: Fifty-three patients between the ages of 12 months and 16 years (mean, 10.7 years) underwent correction programs for 55 limbs (44 tibia and 11 femurs). The etiology of deformity was congenital in 39 cases and acquired in 14. We were able to achieve an acceptable correction of deformity (leg length discrepancy <15 mm, angulation <5 degrees) in 52 limbs. A number of complications were encountered, which are discussed. DISCUSSION AND CONCLUSION: We demonstrate its ease of use for both surgeon and patient and its versatility in a variety of pathologies. The advantages of the TSF system are many. It is a simple frame construct, and application is easy. The plan and execution are structured with precise end points; it is a single-stage correction and thus avoids frame modifications. Any residual deformity can be further corrected by use of the same frame. We conclude that the TSF is an effective and efficient way to correct a wide variety of simple and complex often obstinate pediatric limb deformities.


Asunto(s)
Fijadores Externos , Diferencia de Longitud de las Piernas/cirugía , Deformidades Congénitas de las Extremidades/cirugía , Enfermedades Musculoesqueléticas/cirugía , Adolescente , Niño , Preescolar , Diseño de Equipo , Femenino , Fémur/anomalías , Fémur/cirugía , Estudios de Seguimiento , Humanos , Masculino , Procedimientos Ortopédicos/instrumentación , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Tibia/anomalías , Tibia/cirugía
16.
Clin Cancer Res ; 14(4): 1131-7, 2008 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-18281547

RESUMEN

PURPOSE: This study aimed to define the maximum tolerated dose of weekly docetaxel combined with daily erlotinib, an oral epidermal growth factor receptor tyrosine kinase inhibitor. EXPERIMENTAL DESIGN: Patients with any solid tumor received 150 mg erlotinib with escalating doses of docetaxel (20, 25, 30, and 35 mg/m(2)) on days 1, 8, and 15 every 28 days. The pharmacokinetics of docetaxel and erlotinib was determined on cycle 2, day 1. Erlotinib was given for a maximum of 12 cycles and docetaxel was given for up to 6 cycles. RESULTS: Twenty-five patients (17 males and 8 females) were enrolled with a median age of 56 years (range, 34-76); Eastern Cooperative Oncology Group performance status of 0/1 was 20/5. One patient had a dose-limiting toxicity in cycle 1 at the 25 mg/m(2) level (grade 3 enterocolitis). At 35 mg/m(2) docetaxel dose level, 6 of 10 patients required dose reductions to 30 mg/m(2) beyond cycle 1 due to neutropenia (3 patients) and mucositis, increased bilirubin, and diarrhea (1 patient each). The clearance of docetaxel and erlotinib of 61.7 and 8.16 L/h, respectively, did not seem to differ from historical controls. Responses were seen in non-small cell lung cancer, prostate cancer, and hepatobiliary cancers, including a complete response lasting 36+ months in a patient with hepatocellular carcinoma. CONCLUSION: Although no maximum tolerated dose was reached in cycle 1 with 35 mg/m(2) docetaxel, repetitive dosing proved intolerable in a substantial number of patients; thus, the recommended phase II dose of weekly docetaxel is 30 mg/m(2) when combined with 150 mg of daily erlotinib.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/administración & dosificación , Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/farmacocinética , Neoplasias/tratamiento farmacológico , Adulto , Anciano , Docetaxel , Relación Dosis-Respuesta a Droga , Clorhidrato de Erlotinib , Femenino , Humanos , Masculino , Dosis Máxima Tolerada , Persona de Mediana Edad , Quinazolinas/administración & dosificación , Quinazolinas/efectos adversos , Quinazolinas/farmacocinética , Taxoides/administración & dosificación , Taxoides/efectos adversos , Taxoides/farmacocinética
17.
Cancer Chemother Pharmacol ; 59(2): 261-8, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16733646

RESUMEN

PURPOSE: Paclitaxel and interferon have demonstrated anti-angiogenic activity in vitro and in vivo. The toxicity, pharmacokinetics, and pharmacodynamics of paclitaxel with interferon-alpha2b (IFN-alpha2b) were assessed in patients with solid tumors to assess the feasibility of this novel anti-angiogenic regimen. METHODS: IFN-alpha2b (1 million units) was administered twice daily by subcutaneous injection. Paclitaxel was given weekly over 1 h starting at 30 mg/m2 and increased to 50 mg/m2. Cycles were repeated every 4 weeks. RESULTS: Nineteen patients with a variety of solid tumors were enrolled. Dose-limiting toxicity in cycle 1 was observed at 50 mg/m2. Eleven patients were treated at 40 mg/m2 with no undue toxicity. Pharmacokinetic parameter comparison studies were completed in 11 patients who received days 1 and 29 paclitaxel. Mean paclitaxel clearance and area under the curve (0-infinity) were not statistically different from days 1 to 29. There was a 50% increase in the average Cmax from days 1 to 29. There was also a 73% decrease of matrix metalloproteinase-9 (MMP-9) levels in these 11 patients from days 1 to 29 (p < 0.0005). All three patients with cutaneous angiosarcomas experienced clinically meaningful remissions. In addition, minor responses were observed in one patient with heavily pretreated ovarian cancer and another with adrenocortical carcinoma. CONCLUSION: This trial details the inability to dose escalate to the maximum tolerated dose of weekly paclitaxel when combined with low-dose interferon. However, this low-dose regimen caused a significant decrease in MMP-9 and demonstrated anti-cancer activity in cutaneous angiosarcomas.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias/tratamiento farmacológico , Adulto , Anciano , Anciano de 80 o más Años , Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/farmacocinética , Área Bajo la Curva , Relación Dosis-Respuesta a Droga , Esquema de Medicación , Femenino , Factores de Crecimiento de Fibroblastos/sangre , Factores de Crecimiento de Fibroblastos/orina , Humanos , Inyecciones Intravenosas , Inyecciones Subcutáneas , Interferón alfa-2 , Interferón-alfa/administración & dosificación , Interferón-alfa/efectos adversos , Interferón-alfa/farmacocinética , Masculino , Metaloproteinasa 2 de la Matriz/sangre , Metaloproteinasa 9 de la Matriz/sangre , Tasa de Depuración Metabólica , Persona de Mediana Edad , Neoplasias/metabolismo , Neoplasias/patología , Paclitaxel/administración & dosificación , Paclitaxel/efectos adversos , Paclitaxel/farmacocinética , Proteínas Recombinantes , Resultado del Tratamiento , Molécula 1 de Adhesión Celular Vascular/sangre , Factor A de Crecimiento Endotelial Vascular/sangre , Factor A de Crecimiento Endotelial Vascular/orina
18.
J Vasc Interv Radiol ; 15(11): 1257-62, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15525745

RESUMEN

PURPOSE: To evaluate the Gunther Tulip vena cava filter with regard to ease of placement, complications, and retrieval over long time periods. MATERIALS AND METHODS: In 53 patients (ratio of men to women, 24:29; mean age, 52.8 years) retrievable Gunther Tulip filters (Vena Cava M Reye Filter Set; William Cook Europe, Denmark) were inserted. Indications included planned major surgery with recent pulmonary embolus or high pulmonary embolus risk (n = 16), extensive ilio-femoral thrombus (n = 11), deep vein thrombosis with anticoagulant complications (n = 9), breakthrough pulmonary embolus despite anticoagulant therapy (n = 4), and contraindication to anticoagulant therapy (n = 13). All patients were followed-up for immediate and long-term complications. RESULTS: Fifty-three filters were successfully placed in 52 of 53 patients, yielding a success rate of 98.1%. Nineteen patients underwent attempted retrieval of their filter. Sixteen of 19 retrieval procedures were successful (84%). In three patients, the filter could not be removed on attempted retrieval (extensive filter thrombus in two patients and attachment to the wall in one patient). One patient received two filters, which were both successfully retrieved at a later date. Median implantation time for retrievable filters was 34 days (range, 7-126 days). Mean follow-up for patients with permanent filters was 13 months. Two major complications (pneumothorax and break through pulmonary embolus) and three minor complications (right internal jugular vein thrombosis in two patients and transient Horner's Syndrome in one patient) were recorded. CONCLUSION: Insertion and retrieval of filters is safe and feasible. Preliminary data suggest that Gunther Tulip filter retrieval is feasible over and above the manufacturer's recommended retrieval interval of 14 days.


Asunto(s)
Remoción de Dispositivos/métodos , Implantación de Prótesis/métodos , Filtros de Vena Cava , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Embolia Pulmonar/terapia , Radiografía , Factores de Tiempo , Filtros de Vena Cava/efectos adversos , Vena Cava Inferior/diagnóstico por imagen , Trombosis de la Vena/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...