Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-34067492

RESUMEN

Core stability (CS) deficits can have a significant impact on lower limb function. The aim of this study was to investigate the relationship between two dynamic core exercise assessments and dynamic knee valgus during single-leg squats. In total, 20 physically active female students participated in this study. The OCTOcore smartphone application assesses CS during two dynamic exercise tests, the partial range single-leg deadlift (SLD) test and the bird-dog (BD) test. A two-dimensional assessment of a single-leg squat test was used to quantify participants' hip frontal angle (HFASLS) and knee frontal plane projection angle (FPPASLS). Ankle dorsiflexion was evaluated through the weight-bearing dorsiflexion test. The correlational analyses indicated that the HFASLS was significantly related to the partial range single-leg deadlift test (r = 0.314, p < 0.05) and ankle dorsiflexion (r = 0.322, p < 0.05). The results showed a significant difference (p < 0.05) in the CS test between cases categorised as dynamic knee valgus (>10°) and normal (≤10°). The CS deficit may influence the neuromuscular control of the lumbopelvic-hip complex during single-leg movements. The link between CS and kinematic factors related to knee injuries was only observed when CS was measured in the SLD test but not in the BD test.


Asunto(s)
Pierna , Postura , Animales , Fenómenos Biomecánicos , Perros , Femenino , Humanos , Rodilla , Articulación de la Rodilla , Extremidad Inferior , Rango del Movimiento Articular
2.
PeerJ ; 7: e7485, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31413933

RESUMEN

BACKGROUND: Recently, there has been growing interest in using smartphone applications to assess gait speed and quantify isometric core stability exercise intensity. The purpose of this study was to investigate the between-session reliability and minimal detectable change of a smartphone app for two dynamic exercise tests of the lumbopelvic complex. METHODS: Thirty-three healthy young and active students (age: 22.3 ± 5.9 years, body weight: 66.9 ± 11.3 kg, height: 167.8 ± 10.3 cm) participated in this study. Intraclass correlation coefficient (ICC), coefficient of variation (%CV), and Bland-Altman plots were used to verify the reliability of the test. The standard error of measurement (SEM) and the minimum detectable difference (MDD) were calculated for clinical applicability. RESULTS: The ICCs ranged from 0.73 to 0.96, with low variation (0.9% to 4.8%) between days of assessments. The Bland-Altman plots and one-sample t-tests (p > 0.05) indicated that no dynamic exercise tests changed systematically. Our analyses showed that SEM 0.6 to 1.5 mm/s-2) and MDD (2.1 to 3.5 mm/s-2). CONCLUSION: The OCTOcore app is a reliable tool to assess core stability for two dynamic exercises. A minimal change of 3.5 mm/s-2 is needed to be confident that the change is not a measurement error between two sessions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA