Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39002713

RESUMEN

INTRODUCTION: ST-elevation myocardial infarction (STEMI) remains a leading cause of death despite advances in revascularization and post-STEMI care. Especially for patients with a poor prognosis, there is increasing emphasis on comfort-focused care. METHODS: We conducted a single-center retrospective cohort study of patients with STEMI at a large tertiary care academic medical center, abstracting patient-level data, causes of death, and use of palliative care consultation from the medical records. We sought to investigate the frequency of comfort-focused approaches and palliative care consultation after STEMI. RESULTS: A total of 536 patients presented with or were transferred with STEMI from January 2010 to July 2018, of whom 61/536 (11.4%) died during index hospitalization. Among those who underwent percutaneous intervention (PCI), the in-hospital mortality rate was 6.8%. Median (IQR) and time to death was two (0-6) days. Among those who died, 25/61 (41%) were treated with mechanical circulatory support (MCS). A total of 25/61 (41%) patients died following transition to a comfort-focused approach. Rate of MCS utilization during hospitalization was higher in the group that was ultimately transitioned to comfort-focused measures than the group who received full treatment measures. Palliative care was consulted in the case of 6/61 (9.8%) patients. Median time to consultation was 5 (1-7) days and time to death was 6.5 (2-28) days. DISCUSSION: Transition to comfort-focused care before death after STEMI is common, particularly in those with cardiogenic shock and/or treated with MCS, highlighting the critical status of such patients. Although increasingly employed in recent years, palliative care consults remain rare and are often employed late in the hospitalization.

2.
Clin Transplant ; 38(7): e15401, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39023081

RESUMEN

BACKGROUND: The use of glucagon-like-peptide 1 receptor agonists (GLP1-RA) has dramatically increased over the past 5 years for diabetes mellitus type 2 (T2DM) and obesity. These comorbidities are prevalent in adult heart transplant (HT) recipients. However, there are limited data evaluating the efficacy of this drug class in this population. The aim of the current study was to describe cardiometabolic changes in HT recipients prescribed GLP1-RA at a large-volume transplant center. METHODS: We retrospectively reviewed all adult HT recipients who received GLP1-RA after HT for a minimum of 1-month. Cardiometabolic parameters including body mass index (BMI), lipid panel, hemoglobin A1C, estimated glomerular filtration rate (eGFR), and NT-proBNP were compared prior to initiation of the drug and at most recent follow-up. We also evaluated for significant dose adjustments to immunosuppression after drug initiation and adverse effects leading to drug discontinuation. RESULTS: Seventy-four patients were included (28% female, 53% White, 20% Hispanic) and followed for a median of 383 days [IQR 209, 613] on a GLP1-RA. The majority of patients (n = 56, 76%) were prescribed semaglutide. The most common indication for prescription was T2DM alone (n = 33, 45%), followed by combined T2DM and obesity (n = 26, 35%). At most recent follow-up, mean BMI decreased from 33.3 to 31.5 kg/m2 (p < 0.0001), HbA1C from 7.3% to 6.7% (p = 0.005), LDL from 78.6 to 70.3 mg/dL (p = 0.018) and basal insulin daily dose from 32.6 to 24.8 units (p = 0.0002). CONCLUSION: HT recipients prescribed GLP1-RA therapy showed improved glycemic control, weight loss, and cholesterol levels during the study follow-up period. GLP1-RA were well tolerated and were rarely associated with changes in immunosuppression dosing.


Asunto(s)
Receptor del Péptido 1 Similar al Glucagón , Trasplante de Corazón , Humanos , Femenino , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Receptor del Péptido 1 Similar al Glucagón/agonistas , Trasplante de Corazón/efectos adversos , Estudios de Seguimiento , Pronóstico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Tasa de Filtración Glomerular , Hipoglucemiantes/uso terapéutico , Pruebas de Función Renal , Adulto , Complicaciones Posoperatorias/tratamiento farmacológico , Rechazo de Injerto/etiología , Rechazo de Injerto/prevención & control , Rechazo de Injerto/tratamiento farmacológico , Agonistas Receptor de Péptidos Similares al Glucagón
3.
Artículo en Inglés | MEDLINE | ID: mdl-39023496

RESUMEN

OBJECTIVE: The HeartMate 3 survival risk score was recently validated in the Multicenter study Of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 to predict patient-specific survival in HeartMate 3 left ventricular assist device candidates. The HeartMate 3 survival risk score stratifies individuals into tertiles according to survival probability. METHODS: We performed a single-center retrospective review of all HeartMate 3 left ventricular assist device recipients between September 2017 and August 2022. Baseline characteristics were collected from the electronic medical records. HeartMate 3 survival risk scores were calculated for all eligible patients. One- and 2-year Kaplan-Meier survival analyses were conducted. A univariate and multivariable Cox regression model was used to identify predictors. RESULTS: A total of 181 patients were included in this final analysis. The median age was 62 years, 83% were male, and 26% were Interagency Registry for Mechanically Assisted Circulatory Support Profile 1. The mean HeartMate 3 survival risk score for the entire cohort was 2.66 ± 0.66. Two-year survivals in the high, average, and low survival groups were 93.5% ± 3.2%, 81.6% ± 7.4%, and 82.0% ± 6.6%, respectively. As a continuous variable, the unadjusted HeartMate 3 survival risk score was a significant predictor of mortality (hazard ratio, 2.20; 95% CI, 1.08-4.45; P = .029). The areas under the curve were 0.70 and 0.66 at 1 and 2 years, respectively. We were unable to demonstrate the discriminatory ability of the HeartMate 3 survival risk score using the original stratification, but we found significantly increased survival in the high survival group using a binary cutoff (hazard ratio, 4.8; 95% CI, 1.01-20.9; P = .038). CONCLUSIONS: The unadjusted HeartMate 3 survival risk score was associated with postimplant survival in patients outside of the Multicenter study Of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 but did not remain an independent predictor after adjusting for ischemic etiology and severe diabetes. The HeartMate 3 survival risk score was able to identify patients at high survival using a binary cutoff, but we were unable to demonstrate its discriminatory ability among the previously published risk tertiles.

4.
Clin Transplant ; 38(3): e15251, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38504576

RESUMEN

BACKGROUND: Belatacept (BTC), a fusion protein, selectively inhibits T-cell co-stimulation by binding to the CD80 and CD86 receptors on antigen-presenting cells (APCs) and has been used as immunosuppression in adult renal transplant recipients. However, data regarding its use in heart transplant (HT) recipients are limited. This retrospective cohort study aimed to delineate BTC's application in HT, focusing on efficacy, safety, and associated complications at a high-volume HT center. METHODS: A retrospective cohort study was conducted of patients who underwent HT between January 2017 and December 2021 and subsequently received BTC as part of their immunosuppressive regimen. Twenty-one HT recipients were identified. Baseline characteristics, history of rejection, and indication for BTC use were collected. Outcomes included renal function, graft function, allograft rejection and mortality. Follow-up data were collected through December 2023. RESULTS: Among 776 patients monitored from January 2017 to December 2021 21 (2.7%) received BTC treatment. Average age at transplantation was 53 years (± 12 years), and 38% were women. BTC administration began, on average, 689 [483, 1830] days post-HT. The primary indications for BTC were elevated pre-formed donor-specific antibodies in highly sensitized patients (66.6%) and renal sparing (23.8%), in conjunction with reduced calcineurin inhibitor dosage. Only one (4.8%) patient encountered rejection within a year of starting BTC. Graft function by echocardiography remained stable at 6 and 12 months posttreatment. An improvement was observed in serum creatinine levels (76.2% of patients), decreasing from a median of 1.58 to 1.45 (IQR [1.0-2.1] to [1.1-1.9]) over 12 months (p = .054). eGFR improved at 3 and 6 months compared with 3 months pre- BTC levels; however, this was not statistically significant (p = .24). Treatment discontinuation occurred in seven patients (33.3%) of whom four (19%) were switched back to full dose CNI. Infections occurred in 11 patients (52.4%), leading to BTC discontinuation in 4 patients (19%). CONCLUSION: In this cohort, BTC therapy was used as alternative immunosuppression for management of highly sensitized patients or for renal sparing. BTC therapy when combined with CNI dose reduction resulted in stabilization in renal function as measured through renal surrogate markers, which did not, however, reach statistical significance. Patients on BTC maintained a low rejection rate and preserved graft function. Infections were common during BTC therapy and were associated with medication pause/discontinuation in 19% of patients. Further randomized studies are needed to assess the efficacy and safety of BTC in HT recipients.


Asunto(s)
Trasplante de Corazón , Trasplante de Riñón , Adulto , Humanos , Femenino , Persona de Mediana Edad , Masculino , Abatacept , Estudios Retrospectivos , Trasplante de Riñón/efectos adversos , Inmunosupresores , Inhibidores de la Calcineurina/uso terapéutico , Linfocitos T , Rechazo de Injerto/tratamiento farmacológico , Rechazo de Injerto/etiología , Receptores de Trasplantes , Supervivencia de Injerto
5.
Clin Transplant ; 38(4): e15282, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38546027

RESUMEN

BACKGROUND: There are limited data evaluating the success of a structured transition plan specifically for pediatric heart transplant (HT) recipients following their transfer of care to an adult specialist. We sought to identify risk factors for poor adherence, graft failure, and mortality following the transfer of care to adult HT care teams. METHODS: We retrospectively reviewed all patients who underwent transition from the pediatric to adult HT program at our center between January 2011 and June 2021. Demographic characteristics, comorbid conditions, and psychosocial history were collected at the time of HT, the time of transition, and the most recent follow-up. Adverse events including mortality, graft rejection, infection, and renal function were also captured before and after the transition. RESULTS: Seventy-two patients were identified (54.1% male, 54.2% Caucasian). Mean age at the time of transition was 23 years after a median of 11.6 years in the pediatric program. The use of calcineurin inhibitors was associated with reduced mortality (HR .04, 95% CI .0-.6, p = .015), while prior psychiatric hospitalization (HR 45.3, 95% CI, 6.144-333.9, p = .0001) was associated with increased mortality following transition. Medication nonadherence and young age at the time of transition were markers for high-risk individuals prior to the transition of care. CONCLUSIONS: Transition of HT recipients from a pediatric program to an adult program occurs during a vulnerable time of emerging adulthood, and we have identified risk factors for mortality following transition. Development of a formalized transition plan with a large multidisciplinary team with focused attention on high-risk patients, including those with psychiatric comorbidities, may favorably influence outcomes.


Asunto(s)
Trasplante de Corazón , Cumplimiento de la Medicación , Adulto , Humanos , Niño , Masculino , Femenino , Estudios Retrospectivos , Factores de Riesgo , Rechazo de Injerto/etiología , Receptores de Trasplantes , Grupo de Atención al Paciente
6.
ASAIO J ; 70(8): 641-650, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38373176

RESUMEN

In patients supported by the HeartMate 3 left ventricular assist device (HM3 LVAD), pump speed adjustments may improve hemodynamics. We investigated the hemodynamic implications of speed adjustments in HM3 recipients undergoing hemodynamic ramp tests. Clinically stable HM3 recipients who underwent routine invasive hemodynamic ramp tests between 2015 and 2022 at our center were included. Filling pressure optimization, defined as central venous pressure (CVP) <12 mm Hg and pulmonary capillary wedge pressure (PCWP) <18 mm Hg, was assessed at baseline and final pump speeds. Patients with optimized pressures were compared to nonoptimized patients. Overall 60 HM3 recipients with a median age of 62 years (56, 71) and time from LVAD implantation of 187 days (124, 476) were included. Optimized filling pressures were found in 35 patients (58%) at baseline speed. Speed was adjusted in 84% of the nonoptimized patients. Consequently, 39 patients (65%) had optimized pressures at final speed. There were no significant differences in hemodynamic findings between baseline and final speeds ( p > 0.05 for all). Six and 12 month readmission-free rates were higher in optimized compared with nonoptimized patients ( p = 0.03 for both), predominantly due to lower cardiac readmission-free rates ( p = 0.052). In stable outpatients supported with HM3 who underwent routine ramp tests, optimized hemodynamics were achieved in only 2 of 3 of the patients. Patients with optimized pressures had lower all-cause readmission rates, primarily driven by fewer cardiac-related hospitalizations.


Asunto(s)
Corazón Auxiliar , Hemodinámica , Humanos , Persona de Mediana Edad , Masculino , Femenino , Hemodinámica/fisiología , Anciano , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/cirugía , Estudios Retrospectivos , Presión Esfenoidal Pulmonar/fisiología
7.
JACC Heart Fail ; 12(7): 1179-1192, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38206234

RESUMEN

BACKGROUND: Interventricular interactions may be responsible for the decline in ventricular performance observed in various disease states that primarily affect the contralateral ventricle. OBJECTIVES: This study sought to quantify the impact of such interactions on right ventricular (RV) size and function using clinically stable individuals with left ventricular assist devices (LVADs) as a model for assessing RV hemodynamics while LV loading conditions were acutely manipulated by changing device speed during hemodynamic optimization studies (ie, ramp tests). METHODS: The investigators recorded RV pressure-volume loops with a conductance catheter at various speeds during ramp tests in 20 clinically stable HeartMate3 recipients. RESULTS: With faster LVAD speeds and greater LV unloading, indexed RV end-diastolic volume increased (72.28 ± 15.07 mL at low speed vs 75.95 ± 16.90 at high speed; P = 0.04) whereas indexed end-systolic volumes remained neutral. This resulted in larger RV stroke volumes and shallower end-diastolic pressure-volume relationships. Concurrently, RV end-systolic pressure decreased (31.58 ± 9.75 mL at low speed vs 29.58 ± 9.41 mL at high speed; P = 0.02), but contractility, as measured by end-systolic elastance, did not change significantly. The reduction in RV end-systolic pressure was associated with a reduction in effective arterial elastance from 0.65 ± 0.43 mm Hg/mL at low speed to 0.54 ± 0.33 mm Hg/mL at high speed (P = 0.02). CONCLUSIONS: Interventricular interactions resulted in improved RV compliance, diminished afterload, and did not reduce RV contractility. These data challenge the prevailing view that interventricular interactions compromise RV function, which has important implications for the understanding of RV-LV interactions in various disease states, including post-LVAD RV dysfunction.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Volumen Sistólico , Función Ventricular Derecha , Humanos , Masculino , Persona de Mediana Edad , Femenino , Función Ventricular Derecha/fisiología , Volumen Sistólico/fisiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Disfunción Ventricular Derecha/fisiopatología , Presión Ventricular/fisiología , Anciano , Adulto , Hemodinámica/fisiología
8.
J Card Fail ; 30(1): 95-99, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37625582

RESUMEN

BACKGROUND: Aortic regurgitation (AR) is a common complication following left ventricular assist device (LVAD) implantation. We evaluated the hemodynamic implications of AR in patients with HeartMate 3 (HM3) LVAD at baseline and in response to speed changes. METHODS AND RESULTS: Clinically stable outpatients supported by HM3 who underwent a routine hemodynamic ramp test were retrospectively enrolled in this analysis. Patients were stratified based on the presence of at least mild AR at baseline speed. Hemodynamic and echocardiographic parameters were compared between the AR and non-AR groups. Sixty-two patients were identified. At the baseline LVAD speed, 29 patients (47%) had AR, while 33 patients (53%) did not. Patients with AR were older and supported on HM3 for a longer duration. At baseline speed, all hemodynamic parameters were similar between the groups including central venous pressure, pulmonary capillary wedge pressure, pulmonary arterial pressures, cardiac output and index, and pulmonary artery pulsatility index (p > 0.05 for all). During the subacute assessment, AR worsened in some, but not all, patients, with increases in LVAD speed. There were no significant differences in 1-year mortality or hospitalization rates between the groups, however, at 1-year, ≥ moderate AR and right ventricular failure (RVF) were detected in higher rates among the AR group compared to the non-AR group (45% vs. 0%; p < 0.01, and 75% vs. 36.8%; p = 0.02, respectively). CONCLUSIONS: In a cohort of stable outpatients supported with HM3 who underwent a routine hemodynamic ramp test, the presence of mild or greater AR did not impact the ability of HM3 LVADs to effectively unload the left ventricle during early subacute assessment. Although the presence of AR did not affect mortality and hospitalization rates, it resulted in higher rates of late hemodynamic-related events in the form of progressive AR and RVF.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Estudios Retrospectivos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Hemodinámica/fisiología
9.
Perfusion ; : 2676591231220793, 2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38084918

RESUMEN

BACKGROUND: This study examines the role of extracorporeal life support flow in the development of acute kidney injury in cardiogenic shock. METHODS: We performed a retrospective analysis of 465 patients placed on extracorporeal life support at our institution between January 2015 and December 2020 for cardiogenic shock. Flow index was calculated by dividing mean flow by body surface. Stages of acute kidney injury were determined according to Kidney Disease: Improving Global Outcomes (KDIGO) organization guidelines. RESULTS: There were 179 (38.5%) patients who developed acute kidney injury, 63.1% of which were classified as Stage 3--the only subgroup associated with 1-year mortality (hazard ratio = 2.03, p < .001). Risk of kidney injury increased up to a flow index of 1.6 L/min/m2, and kidney injury was more common among patients with flow index greater than 1.6 L/min/m2 (p = .034). Those with kidney injury had higher baseline lactate levels (4.4 vs 3.1, p = .04), and Stage 3 was associated wit higher baseline creatinine (p < .001). CONCLUSIONS: In our cohort, kidney injury was common and Stage 3 kidney injury was associated with worse outcomes compared to other stages. Low flow was not associated with increased risk of kidney injury. Elevated baseline lactate and creatinine among patients with acute kidney injury suggest underlying illness severity, rather than flow, may influence kidney injury risk.

10.
ASAIO J ; 2023 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-37934714

RESUMEN

This review discusses the challenges and outcomes associated with pregnancy during left ventricular assist device (LVAD) support. Women account for a third of the heart failure population in the United States. Left ventricular assist devices have emerged as a safe and effective treatment option for patients with advanced heart failure. Pregnancy during LVAD support can occur, and it presents significant risks to both mother and fetus, including hemodynamic stress, thrombotic events, medication-associated teratogenicity, and uterine impingement. This literature review identified 10 cases of confirmed pregnancy during LVAD support, of which eight resulted in successful births. Maternal and fetal mortality occurred in one case, and there was a spontaneous abortion in one case. The review highlights the importance of a multidisciplinary approach, promotion of shared decision-making, thoughtful anticoagulation, adjustment of LVAD speed, and medication optimization to maintain hemodynamic support during pregnancy. Hemodynamic changes during pregnancy include increased cardiac output, heart rate, and plasma volume, as well as decreased systemic vascular resistance, which can impact LVAD support. Despite reduced pulsatility in LVAD-supported patients, ovulation and reproductive capacity might be preserved, and viable pregnancies may be achieved with appropriate management. The review provides insights into the risks and considerations for a viable pregnancy during LVAD support, including the need for ongoing research to inform joined decision-making.

11.
Intensive Care Med ; 49(12): 1456-1466, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37792052

RESUMEN

PURPOSE: Venoarterial extracorporeal membrane oxygenation (V-A ECMO) can be used to support severely ill patients with cardiogenic shock. While age is commonly used in patient selection, little is known regarding its association with outcomes in this population. We sought to evaluate the association between increasing age and outcomes following V-A ECMO. METHODS: We used individual-level patient data from 440 centers in the international Extracorporeal Life Support Organization registry. We included all adult patients receiving V-A ECMO from 2017 to 2019. The primary outcome was hospital mortality. Secondary outcomes included a composite of complications following initiation of V-A ECMO. We conducted Bayesian analyses of the relationship between increasing age and outcomes of interest. RESULTS: We included 15,172 patients receiving V-A ECMO. Of these, 8172 (53.9%) died in hospital. For the analysis conducted using weakly informed priors, and as compared to the reference category of age 18-29, the age bracket of 30-39 (odds ratio [OR] 0.94, 95% credible interval [CrI] 0.79-1.10) was not associated with hospital mortality, but age brackets 40-49 (odds ratio [OR] 1.26, 95% CrI: 1.08-1.47), 50-59 (OR 1.78, 95% CrI: 1.55-2.06), 60-69 (OR 2.24, 95% CrI: 1.94-2.59), 70-79 (OR 2.90, 95% CrI: 2.49-3.39) and ≥ 80 (OR 4.02, 95% CrI: 3.13-5.20) were independently associated with increasing hospital mortality. Similar results were found in the analysis conducted with an informative prior, as well as between increasing age and post-ECMO complications. CONCLUSIONS: Among patients receiving V-A ECMO for cardiogenic shock, increasing age is strongly associated with increasing odds of death and complications, and this association emerges as early as 40 years of age.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Adulto , Humanos , Adolescente , Adulto Joven , Oxigenación por Membrana Extracorpórea/métodos , Teorema de Bayes , Choque Cardiogénico/terapia , Oportunidad Relativa , Sistema de Registros , Mortalidad Hospitalaria , Estudios Retrospectivos
12.
Crit Care ; 27(1): 408, 2023 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-37891688

RESUMEN

Dual circulation is a common but underrecognized physiological occurrence associated with peripheral venoarterial extracorporeal membrane oxygenation (ECMO). Competitive flow will develop between blood ejected from the heart and blood travelling retrograde within the aorta from the ECMO reinfusion cannula. The intersection of these two competitive flows is referred to as the "mixing point". The location of this mixing point, which depends upon the relative strengths of the native and extracorporeal pumps, will determine which regions of the body are perfused with blood ejected from the left ventricle and which regions are perfused by reinfused blood from the ECMO circuit, effectively establishing dual circulations. Because gas exchange within these circulations is dictated by the native lungs and membrane lung, respectively, oxygenation and carbon dioxide removal may differ between regions-depending on how well gas exchange is preserved within each circulation-potentially leading to differential oxygenation or differential carbon dioxide, each of which may have important clinical implications. In this perspective, we address the identification and management of dual circulation and differential gas exchange through various clinical scenarios of venoarterial ECMO. Recognition of dual circulation, proper monitoring for differential gas exchange, and understanding the various strategies to resolve differential oxygenation and carbon dioxide may allow for more optimal patient management and improved clinical outcomes.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Respiratoria , Humanos , Oxigenación por Membrana Extracorpórea/efectos adversos , Insuficiencia Respiratoria/etiología , Dióxido de Carbono , Pulmón , Corazón
13.
Artículo en Inglés | MEDLINE | ID: mdl-37739242

RESUMEN

BACKGROUND: Aortic root thrombosis(ART) is a complication of continuous-flow left ventricular assist device therapy. However, the incidence and related complications of ART in HeartMate 3 (HM3) patients remain unknown. METHODS: Patients who underwent HM3 implantation from November 2014 to August 2020 at a quaternary academic medical center were included. Demographics and outcomes were abstracted from the medical record. Echocardiograms and contrast-enhanced computed tomography studies were reviewed to identify patients who developed ART and/or moderate or greater aortic insufficiency (AI) on HM3 support. RESULTS: The study cohort included 197 HM3 patients with a median postimplant follow-up of 17.5 months. Nineteen patients (9.6%) developed ART during HM3 support, and 15 patients (7.6%) developed moderate or greater AI. Baseline age, gender, race, implantation strategy, and INTERMACS classification were similar between the ART and no-ART groups. ART was associated with an increased risk of death, stroke, or aortic valve (AV) intervention (subhazard ratio [SHR] 3.60 [95% confidence interval (CI) 1.71-7.56]; p = 0.001) and moderate or greater AI (SHR 11.1 [CI 3.60-34.1]; p < 0.001) but was not associated with a statistically significantly increased risk of death or stroke on HM3 support (2.12 [0.86-5.22]; p = 0.10). Of the 19 patients with ART, 6 (31.6%) developed moderate or greater AI, necessitating more frequent AV interventions (ART: 5 AV interventions [3 surgical repairs, 1 surgical replacement, 1 transcatheter replacement; 26.3%]; no-ART: 0). CONCLUSIONS: Nearly 10% of HM3 patients developed ART during device support. ART was associated with increased risk of a composite end-point of death, stroke, or AV intervention as well as moderate or greater AI.

14.
J Heart Lung Transplant ; 42(11): 1497-1500, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37506955

RESUMEN

The 2018 heart allocation policy sought to improve risk stratification and reduce waitlist mortality for the sickest patients. This study sought to evaluate changes in wait times for the highest priority patients since policy implementation. All adult single-organ transplant recipients were identified in the United Network for Organ Sharing registry from October 18, 2018, to July 8, 2022, and separated into 4 periods. Outcomes were compared by blood type and UNOS region. Over the study period, 897 of 9,143 patients were listed as status 1 with no significant change in median wait time by blood type or region. More patients were listed as status 2 (4,523/9,143), and each subsequent period postpolicy change was associated with a 4.2-day increase in mean status 2 waitlist time (95% confidence interval 3.0-5.5, p < 0.0001). Wait times were longest for candidates with blood type O and shortest for AB & A. Regional variations continued, however, wait time increased in every region over time.

16.
Ann Thorac Surg ; 115(5): 1282-1288, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-34998738

RESUMEN

BACKGROUND: In patients with the HeartMate 3 (HM3, Abbott) left ventricular (LV) assist device (LVAD), outflow graft narrowing has been reported as a result of accumulation of biodebris either internal or external to the graft. This study describes the prevalence, imaging findings, and clinical outcomes associated with HM3 LVAD outflow graft narrowing. METHODS: A single-center retrospective cohort study was performed in patients who received an HM3 LVAD between November 2014 and July 2019. All patients with a computed tomographic (CT) angiogram or a CT scan with intravenous contrast sufficient to evaluate the outflow graft lumen were included. Narrowing was defined as a hypodensity of ≥3 mm. RESULTS: Of 165 HM3 LVAD recipients, 46 (28%) had qualifying imaging. Outflow graft narrowing was present in 33% (15/46). One patient had complete obstruction requiring emergency surgery, whereas 14 patients had a median hypodensity of 4.5 mm (interquartile range, 3.3-5.8 mm). The presence of outflow graft narrowing was significantly associated with a longer duration of LVAD support (588.2 ± 277.5 days vs 131.5 ± 170.9 days; P < .0001). One-year survival after identification of narrowing was 93%, with death occurring in 1 patient with complete obstruction. LV unloading (mean percent decrease in LV end-diastolic diameter at time of CT imaging vs pre-LVAD) was 16.7% vs 17.7% in patients with and without narrowing, respectively (P = .86). CONCLUSIONS: Among patients with adequate imaging, one-third have evidence of narrowing. Outflow graft narrowing secondary to biodebris was more likely to be found in HM3 LVAD recipients with longer duration of LVAD support. There was no significant difference in LV unloading between patients with and without narrowing.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Insuficiencia Cardíaca/cirugía , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Factores de Tiempo
17.
Clin Transplant ; 36(12): e14831, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36271917

RESUMEN

BACKGROUND: Significant weight loss due to cardiac cachexia is an independent predictor of mortality in many heart failure (HF) clinical trials. The impact of significant weight loss while on the waitlist for heart transplant (HT) has yet to be studied with respect to post-transplant survival. METHODS: Adult HT recipients from 2010 to 2021 were identified in the UNOS registry. Patients who experienced an absolute weight change from the time of listing to transplant were included and classified into two groups by percent weight loss from time of listing to time of transplant using a cut-off of 10%. The primary endpoint was 1-year survival following HT. RESULTS: 5951 patients were included in the analysis, of whom 763 (13%) experienced ≥10% weight loss from the time of listing to transplant. Weight loss ≥ 10% was associated with reduced 1-year post-transplant survival (86.9% vs. 91.0%, long-rank p = .0003). Additionally, weight loss ≥ 10% was an independent predictor of 1-year mortality in a multivariable model adjusting for significant risk factors (adjusted HR 1.23, 95% CI 1.04-1.46). In secondary analyses, weight loss ≥ 10% was associated with reduced 1-year survival independent of hospitalized status at time of transplant as well as obesity status at listing (i.e., body mass index [BMI] < 30 kg/m2 and BMI ≥ 30 kg/m2 ). CONCLUSIONS: Preoperative weight loss ≥ 10% is associated with reduced survival in patients listed for HT. Nutrition interventions prior to transplant may prove beneficial in this population.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Adulto , Humanos , Estudios Retrospectivos , Obesidad/epidemiología , Pérdida de Peso , Listas de Espera
18.
ASAIO J ; 68(6): 800-807, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35380184

RESUMEN

The use of venoarterial extracorporeal membrane oxygenation (VA-ECMO) following acute myocardial infarction with cardiogenic shock (AMI-CS) is increasing, but the ability to predict favorable outcomes with support remains limited. We retrospectively reviewed all patients with AMI-CS supported with VA-ECMO between December 2008 and June 2018. One hundred twenty-six patients received VA-ECMO for AMI-CS during the study period; of these, 39 (31.0%) experienced ventricular recovery and were discharged while 87 (69.0%) did not recover, with 71 (56.3%) dying in the hospital and 16 (12.7%) surviving to discharge with either left ventricular assist device or heart transplant. TIMI 3 flow in culprit artery (OR, 4.01; 95% CI, 1.25-12.77; p = 0.02), serum lactate (OR, 0.89; 95% CI, 0.80-0.99; p = 0.04), and prompt revascularization (OR, 3.39; 95% CI, 1.18-9.81; p = 0.02) were independent predictors of ventricular recovery. Four variables emerged as independent predictors of in-hospital mortality and were used to create the AMI-ECMO Risk Score: age >70 years, creatinine >1.5 mg/dL, serum lactate > 4.0 mmol/L, and lack of TIMI 3 flow in culprit artery. In patients supported with VA-ECMO for AMI-CS, prompt, successful revascularization, and lower serum lactate were associated with ventricular recovery while younger age, lower serum lactate, and creatinine, and successful revascularization were associated with survival to discharge. The AMI-ECMO risk score is a simple tool that can help risk stratify patients with AMI-CS being considered for VA-ECMO support.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Infarto del Miocardio , Anciano , Creatinina , Humanos , Lactatos , Infarto del Miocardio/complicaciones , Infarto del Miocardio/cirugía , Estudios Retrospectivos , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia
19.
JACC Heart Fail ; 10(1): 12-23, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34969492

RESUMEN

OBJECTIVES: This analysis sought to investigate the waitlist and post-transplant outcomes of individuals bridged to transplantation by using temporary percutaneous endovascular mechanical circulatory support (tMCS) through a status 2 designation (cardiogenic shock and exception). BACKGROUND: The 2018 donor heart allocation policy change granted a status 2 designation to patients supported with tMCS. METHODS: Adult patients in the United Network for Organ Sharing registry after October 18, 2018 who received a status 2 designation for tMCS were included and grouped by their status 2 criteria: cardiogenic shock with hemodynamic criteria (CS-HD), cardiogenic shock without hemodynamic criteria before tMCS (CS-woHD), and exception. Baseline characteristics, waitlist events (death and delisting), and post-transplant outcomes were compared. RESULTS: A total of 2,279 patients met inclusion criteria: 68.6% (n = 1,564) with CS-HD, 3.2% (n = 73) with CS-woHD, and 28.2% (n = 642) with exceptions. A total of 64.2% of patients underwent heart transplantation within 14 days of status 2 listing or upgrade, and 1.9% died or were delisted for worsening clinical condition. Among the 35.8% who did not undergo transplantation following 14 days, only 2.8% went on to receive a left ventricular assist device (LVAD). The 30-day transplantation likelihood was similar among groups: 80.1% for the CS-HD group vs 79.7% for the exception group vs 73.3% for the CS-woHD group; P = 0.31. However, patients who met criteria for CS-woHD had 2.3-fold greater risk of death or delisting (95% CI: 1.10-4.75; P = 0.03) compared with CS-HD patients after multivariable adjustment. Pre-tMCS hemodynamics were not associated with adverse waitlist events. CONCLUSIONS: The use of tMCS is an efficient, safe, and effective strategy as a bridge to transplantation; however, patients with CS-woHD may represent a high-risk cohort. Transition to a durable LVAD was a rare event in this group.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Adulto , Insuficiencia Cardíaca/cirugía , Humanos , Contrapulsador Intraaórtico , Estudios Retrospectivos , Choque Cardiogénico/terapia , Donantes de Tejidos
20.
Catheter Cardiovasc Interv ; 99(1): 37-47, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-33325612

RESUMEN

OBJECTIVES: To describe hemodynamic efficacy and clinical outcomes of Impella percutaneous left ventricular assist device (pLVAD) in patients with cardiogenic shock (CS). BACKGROUND: Percutaneous LVADs are increasingly used in CS management. However, device-related outcomes and optimal utilization remain active areas of investigation. METHODS: All CS patients receiving pLVAD as mechanical circulatory support (MCS) between 2011 and 2017 were identified. Clinical characteristics and outcomes were analyzed. A multivariable logistic regression model was created to predict MCS escalation despite pLVAD. Outcomes were compared between early and late implantation. RESULTS: A total of 115 CS patients (mean age 63.6 ± 13.8 years; 69.6% male) receiving pLVAD as MCS were identified, the majority with CS secondary to acute myocardial infarction (AMI; 67.0%). Patients experienced significant cardiac output improvement (median 3.39 L/min to 3.90 L/min, p = .002) and pharmacological support reduction (median vasoactive-inotropic score [VIS] 25.4 to 16.4, p = .049). Placement of extracorporeal membrane oxygenation (ECMO) occurred in 48 (41.7%) of patients. Higher pre-pLVAD VIS was associated with subsequent MCS escalation in the entire cohort and AMI subgroup (OR 1.27 [95% CI 1.02-1.58], p = .034 and OR 1.72 [95% CI 1.04-2.86], p = .035, respectively). Complications were predominantly access site related (bleeding [9.6%], vascular injury [5.2%], and limb ischemia [2.6%]). In-hospital mortality was 57.4%, numerically greater survival was noted with earlier device implantation. CONCLUSIONS: Treatment with pLVAD for CS improved hemodynamic status but did not uniformly obviate MCS escalation. Mortality in CS remains high, though earlier device placement for appropriately selected patients may be beneficial.


Asunto(s)
Corazón Auxiliar , Choque Cardiogénico , Centros Médicos Académicos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA