1.
Infect Control Hosp Epidemiol ; 43(1): 105-107, 2022 Jan.
Article En | MEDLINE | ID: mdl-33427146

The vacuum-exhausted isolation locker (VEIL) provides a safety barrier during the care of COVID-19 patients. The VEIL is a 175-L enclosure with exhaust ports to continuously extract air through viral particle filters connected to hospital suction. Our experiments show that the VEIL contains and exhausts exhaled aerosols and droplets.


COVID-19 , Aerosols , Humans , Inpatients , Pandemics , SARS-CoV-2 , Vacuum
2.
Phys Rev E ; 94(5-2): 059901, 2016 Nov.
Article En | MEDLINE | ID: mdl-27967041

This corrects the article DOI: 10.1103/PhysRevE.89.013203.

3.
Rev Sci Instrum ; 87(1): 014902, 2016 Jan.
Article En | MEDLINE | ID: mdl-26827343

We investigate the enhancement of heat transfer in the nucleate boiling regime by inducing high frequency acoustic waves (f ∼ 10(6) Hz) on the heated surface. In the experiments, liquid droplets (deionized water) are dispensed directly onto a heated, vibrating substrate. At lower vibration amplitudes (ξs ∼ 10(-9) m), the improved heat transfer is mainly due to the detachment of vapor bubbles from the heated surface and the induced thermal mixing. Upon increasing the vibration amplitude (ξs ∼ 10(-8) m), the heat transfer becomes more substantial due to the rapid bursting of vapor bubbles happening at the liquid-air interface as a consequence of capillary waves travelling in the thin liquid film between the vapor bubble and the air. Further increases then lead to rapid atomization that continues to enhance the heat transfer. An acoustic wave displacement amplitude on the order of 10(-8) m with 10(6) Hz order frequencies is observed to produce an improvement of up to 50% reduction in the surface temperature over the case without acoustic excitation.

4.
Soft Matter ; 11(41): 8076-82, 2015 Nov 07.
Article En | MEDLINE | ID: mdl-26333170

Suspensions of copper nanowires are emerging as new electronic inks for next-generation flexible electronics. Using a novel surface acoustic wave driven extensional flow technique we are able to perform currently lacking analysis of these suspensions and their complex buffer. We observe extensional viscosities from 3 mPa s (1 mPa s shear viscosity) to 37.2 Pa s via changes in the suspension concentration, thus capturing low viscosities that have been historically very challenging to measure. These changes equate to an increase in the relative extensional viscosity of nearly 12,200 times at a volume fraction of just 0.027. We also find that interactions between the wires and the necessary polymer additive affect the rheology strongly. Polymer-induced elasticity shows a reduction as the buffer relaxation time falls from 819 to 59 µs above a critical particle concentration. The results and technique presented here should aid in the future formulation of these promising nanowire suspensions and their efficient application as inks and coatings.

5.
Article En | MEDLINE | ID: mdl-26066257

We derive a generalized equation that governs the spreading of liquid films under high-frequency (MHz-order) substrate vibration in the form of propagating surface waves and show that this single relationship is universally sufficient to collectively describe the rich and diverse dynamic phenomena recently observed for the transport of oil films under such substrate excitation, in particular, Rayleigh surface acoustic waves. In contrast to low-frequency (Hz- to kHz-order) vibration-induced wetting phenomena, film spreading at such high frequencies arises from convective drift generated by the viscous periodic flow localized in a region characterized by the viscous penetration depth ß(-1)≡(2µ/ρω)(1/2) adjacent to the substrate that is invoked directly by its vibration; µ and ρ are the viscosity and the density of the liquid, respectively, and ω is the excitation frequency. This convective drift is responsible for driving the spreading of thin films of thickness h≪k(l)(-1), which spread self-similarly as t(1/4) along the direction of the drift corresponding to the propagation direction of the surface wave, k(l) being the wave number of the compressional acoustic wave that forms in the liquid due to leakage of the surface wave energy from the substrate into the liquid and t the time. Films of greater thicknesses h∼k(l)(-1)≫ß(-1), in contrast, are observed to spread with constant velocity but in a direction that opposes the drift and surface wave propagation due to the attenuation of the acoustic wave in the liquid. The universal equation derived allows for the collective prediction of the spreading of these thin and thick films in opposing directions.

6.
Rev Sci Instrum ; 86(5): 056106, 2015 May.
Article En | MEDLINE | ID: mdl-26026567

Overall precision of the simplified calibration method in J. E. Sader et al., Rev. Sci. Instrum. 83, 103705 (2012), Sec. III D, is dominated by the spring constant of the reference cantilever. The question arises: How does one take measurements from multiple reference cantilevers, and combine these results, to improve uncertainty of the reference cantilever's spring constant and hence the overall precision of the method? This question is addressed in this note. Its answer enables manufacturers to specify of a single set of data for the spring constant, resonant frequency, and quality factor, from measurements on multiple reference cantilevers. With this data set, users can trivially calibrate cantilevers of the same type.

7.
Biomicrofluidics ; 9(5): 052603, 2015 Sep.
Article En | MEDLINE | ID: mdl-25945147

Nebulizers have considerable advantages over conventional inhalers for pulmonary drug administration, particularly because they do not require coordinated breath actuation to generate and deliver the aerosols. Nevertheless, besides being less amenable to miniaturization and hence portability, some nebulizers are prone to denature macromolecular drugs due to the large forces generated during aerosolization. Here, we demonstrate a novel portable acoustomicrofluidic device capable of nebulizing epidermal growth factor receptor (EGFR) monoclonal antibodies into a fine aerosol mist with a mass median aerodynamic diameter of approximately 1.1 µm, optimal for deep lung deposition via inhalation. The nebulized monoclonal antibodies were tested for their stability, immunoactivity, and pharmacological properties, which confirmed that nebulization did not cause significant degradation of the antibody. In particular, flow cytometry demonstrated that the antigen binding capability of the antibody is retained and able to reduce phosphorylation in cells overexpressing the EGFR, indicating that the aerosols generated by the device were loaded with stable and active monoclonal antibodies. The delivery of antibodies via inhalation, particularly for the treatment of lung cancer, is thus expected to enhance the efficacy of this protein therapeutic by increasing the local concentration where they are needed.

8.
Soft Matter ; 11(23): 4658-68, 2015 Jun 21.
Article En | MEDLINE | ID: mdl-25969844

Suspensions of motile cells are model systems for understanding the unique mechanical properties of living materials which often consist of ensembles of self-propelled particles. We present here a quantitative comparison of theory against experiment for the rheology of such suspensions in extensional flows. The influence of motility on viscosities of cell suspensions is studied using a novel acoustically-driven microfluidic capillary-breakup extensional rheometer. Motility increases the extensional viscosity of suspensions of algal pullers, but decreases it in the case of bacterial or sperm pushers. A recent model [Saintillan, Phys. Rev. E: Stat., Nonlinear, Soft Matter Phys., 2010, 81, 56307] for dilute active suspensions is extended to obtain predictions for higher concentrations, after independently obtaining parameters such as swimming speeds and diffusivities. We show that details of body and flagellar shape can significantly determine macroscale rheological behaviour.


Bacteria/metabolism , Flagella/metabolism , Models, Biological , Viscosity
9.
Nano Lett ; 15(2): 883-90, 2015 Feb 11.
Article En | MEDLINE | ID: mdl-25562610

The exhibition of plasmon resonances in two-dimensional (2D) semiconductor compounds is desirable for many applications. Here, by electrochemically intercalating lithium into 2D molybdenum disulfide (MoS2) nanoflakes, plasmon resonances in the visible and near UV wavelength ranges are achieved. These plasmon resonances are controlled by the high doping level of the nanoflakes after the intercalation, producing two distinct resonance peak areas based on the crystal arrangements. The system is also benchmarked for biosensing using bovine serum albumin. This work provides a foundation for developing future 2D MoS2 based biological and optical units.


Disulfides/chemistry , Molybdenum/chemistry , Surface Plasmon Resonance
10.
Adv Sci (Weinh) ; 2(6): 1500062, 2015 06.
Article En | MEDLINE | ID: mdl-27980952

Furthering the promise of graphene-based planar nanofluidic devices as flexible, robust, low cost, and facile large-scale alternatives to conventional nanochannels for ion transport, we show how the nonlinear current-voltage (I-V) characteristics and ion current rectification in these platforms can be enhanced by increasing the system asymmetry. Asymmetric cuts made to the 2D multilayered graphene oxide film, for example, introduces further asymmetry to that natively inherent in the structurally symmetric system, which was recently shown to be responsible for its rectification behavior due to diffusion boundary layer fore-aft asymmetry. Supported by good agreement with theory, we attribute the enhancement to the decrease in the limiting current in the positive bias state in which counter-ion trapping occurs within the negatively charged graphene oxide sheets due to increased film permselectivity as its cross-section and surface charge distribution is altered on one end; these effects being shown to be sensitive to the electrolyte pH. Further, we show that an imbalance in the pH or concentration in the microreservoirs flanking the film can also increase asymmetry and hence rectification, in addition to displaying a host of other phenomena associated with the I-V characteristics of typical nanochannel electrokinetic systems.

11.
Lab Chip ; 15(1): 43-6, 2015 Jan 07.
Article En | MEDLINE | ID: mdl-25343424

We present a versatile and very low-power traveling SAW microfluidic sorting device able to displace and separate particles of different diameter in aqueous suspension; the travelling wave propagates through the fluid bulk and diffuses via a Schröder diffuser, adapted from its typical use in concert hall acoustics to be the smallest such diffuser to be suitable for microfluidics. The effective operating power range is two to three orders of magnitude less than current SAW devices, uniquely eliminating the need for amplifiers, and by using traveling waves to impart forces directly upon suspended microparticles, they can be separated by size.


Acoustics/instrumentation , Microfluidic Analytical Techniques/instrumentation , Diffusion , Equipment Design , Sound
12.
Sci Rep ; 4: 7420, 2014 Dec 11.
Article En | MEDLINE | ID: mdl-25502015

The synthesis of metal frameworks perforated with nanotunnels is a challenge because metals have high surface energies that favor low surface area structures; traditional liquid-crystal templating techniques cannot achieve the synthetic control required. We report a synthetic strategy to fabricate metal nanomaterials with highly ordered, tunable mesostructures in confined systems based on a new quasi-hard-templating liquid-crystals mechanism. The resulting platinum nanowires exhibit long range two-dimensional hexagonally ordered mesopore structures. In addition, single crystalline hexagonal mesoporous platinum nanowires with dominant {110} facets have been synthesized. Finally, we demonstrate that the mesostructures of metal nanomaterials can be tuned from hexagonal to lamellar mesostructures.

13.
Rev Sci Instrum ; 85(11): 116101, 2014 Nov.
Article En | MEDLINE | ID: mdl-25430150

A simplified method for calibrating atomic force microscope cantilevers was recently proposed by Sader et al. [Rev. Sci. Instrum. 83, 103705 (2012); Sec. III D] that relies solely on the resonant frequency and quality factor of the cantilever in fluid (typically air). This method eliminates the need to measure the hydrodynamic function of the cantilever, which can be time consuming given the wide range of cantilevers now available. Using laser Doppler vibrometry, we rigorously assess the accuracy of this method for a series of commercially available cantilevers and explore its performance under non-ideal conditions. This shows that the simplified method is highly accurate and can be easily implemented to perform fast, robust, and non-invasive spring constant calibration.

14.
Anal Chem ; 86(21): 10812-9, 2014 Nov 04.
Article En | MEDLINE | ID: mdl-25275830

Conventional flow injection systems for aquatic environmental analysis typically comprise large laboratory benchscale equipment, which place considerable constraints for portable field use. Here, we demonstrate the use of an integrated acoustically driven microfluidic mixing scheme to enhance detection of a chemiluminescent species tris(2,2'-bipyridyl)dichlororuthenium(II) hexahydrate-a common chemiluminescent reagent widely used for the analysis of a wide range of compounds such as illicit drugs, pharmaceuticals, and pesticides-such that rapid in-line quantification can be carried out with sufficient on-chip sensitivity. Specifically, we employ surface acoustic waves (SAWs) to drive intense chaotic streaming within a 100 µL chamber cast in polydimethoxylsiloxane (PDMS) atop a microfluidic chip consisting of a single crystal piezoelectric material. By optimizing the power, duration, and orientation of the SAW input, we show that the mixing intensity of the sample and reagent fed into the chamber can be increased by one to two orders of magnitude, leading to a similar enhancement in the detection sensitivity of the chemiluminescent species and thus achieving a theoretical limit of detection of 0.02 ppb (0.2 nM) of l-proline-a decade improvement over the industry gold-standard and two orders of magnitude more sensitive than that achievable with conventional systems-simply using a portable photodetector and without requiring sample preconcentration. This on-chip microfluidic mixing strategy, together with the integrated miniature photodetector and the possibility for chip-scale microfluidic actuation, then alludes to the attractive possibility of a completely miniaturized platform for portable field-use microanalytical systems.

15.
Langmuir ; 30(37): 11243-7, 2014 Sep 23.
Article En | MEDLINE | ID: mdl-25186138

Poloidal flow is curiously formed in a microliter sessile water drop over 157-225 MHz because of acoustic streaming from three-dimensional standing Lamb waves in a lithium niobate substrate. The flow possesses radial symmetry with downwelling at the center and upwelling around the periphery of the drop. Outside this frequency range, the attenuation occurs over a length scale incompatible with the drop size and the poloidal flow vanishes. Remarkably, shear-induced migration was found to drive toroidal particle ring formation with diameters inversely proportional to the frequency of the acoustic irradiation.

16.
Respir Res ; 15: 60, 2014 May 20.
Article En | MEDLINE | ID: mdl-24884387

BACKGROUND: Pulmonary-delivered gene therapy promises to mitigate vaccine safety issues and reduce the need for needles and skilled personnel to use them. While plasmid DNA (pDNA) offers a rapid route to vaccine production without side effects or reliance on cold chain storage, its delivery to the lung has proved challenging. Conventional methods, including jet and ultrasonic nebulizers, fail to deliver large biomolecules like pDNA intact due to the shear and cavitational stresses present during nebulization. METHODS: In vitro structural analysis followed by in vivo protein expression studies served in assessing the integrity of the pDNA subjected to surface acoustic wave (SAW) nebulisation. In vivo immunization trials were then carried out in rats using SAW nebulized pDNA (influenza A, human hemagglutinin H1N1) condensate delivered via intratracheal instillation. Finally, in vivo pulmonary vaccinations using pDNA for influenza was nebulized and delivered via a respirator to sheep. RESULTS: The SAW nebulizer was effective at generating pDNA aerosols with sizes optimal for deep lung delivery. Successful gene expression was observed in mouse lung epithelial cells, when SAW-nebulized pDNA was delivered to male Swiss mice via intratracheal instillation. Effective systemic and mucosal antibody responses were found in rats via post-nebulized, condensed fluid instillation. Significantly, we demonstrated the suitability of the SAW nebulizer to administer unprotected pDNA encoding an influenza A virus surface glycoprotein to respirated sheep via aerosolized inhalation. CONCLUSION: Given the difficulty of inducing functional antibody responses for DNA vaccination in large animals, we report here the first instance of successful aerosolized inhalation delivery of a pDNA vaccine in a large animal model relevant to human lung development, structure, physiology, and disease, using a novel, low-power (<1 W) surface acoustic wave (SAW) hand-held nebulizer to produce droplets of pDNA with a size range suitable for delivery to the lower respiratory airways.


Gene Transfer Techniques , Lung/physiology , Sound , Vaccination/methods , Vaccines, DNA/administration & dosage , Vaccines, DNA/genetics , Administration, Inhalation , Aerosols , Animals , Female , Humans , Male , Mice , Nebulizers and Vaporizers , Rats , Rats, Sprague-Dawley , Sheep , Surface Properties , Treatment Outcome
17.
Lab Chip ; 14(11): 1802-5, 2014 Jun 07.
Article En | MEDLINE | ID: mdl-24770695

It is now possible to circumvent costly and complex cleanroom fabrication procedures to produce MHz-order acoustically-driven microfluidic platforms through the use of electrode strips cut simply from kitchen aluminium foil and pressed against piezoelectric substrates. Cleanroom deposition, lithographic patterning, and etching are entirely avoided in favor of this cut-and-place technique, which enables the generation of acoustic Lamb waves of sufficient amplitude to demonstrate rapid and efficient microfluidic transport and manipulation, microcentrifugation, and even nebulization of both sessile drops and paper-based substrates. Elimination of microfabrication processes typical of acoustic microfluidics brings us a significant step closer towards commercially-viable consumer diagnostic devices, especially for use in the developing world.


Acoustics , Microfluidic Analytical Techniques , Aluminum , Electrodes
18.
Lab Chip ; 14(11): 1858-65, 2014 Jun 07.
Article En | MEDLINE | ID: mdl-24740643

A practical, commercially viable microfluidic device relies upon the miniaturization and integration of all its components--including pumps, circuitry, and power supply--onto a chip-based platform. Surface acoustic waves (SAW) have become popular in microfluidic manipulation, in solving the problems of microfluidic manipulation, but practical applications employing SAW still require more power than available via a battery. Introducing amplitude modulation at 0.5-40 kHz in SAW nebulization, which requires the highest energy input levels of all known SAW microfluidic processes, halves the power required to 1.5 W even while including the power in the sidebands, suitable for small lithium ion batteries, and maintains the nebulization rate, size, and size distributions vital to drug inhalation therapeutics. This simple yet effective means to enable an integrated SAW microfluidics device for nebulization exploits the relatively slow hydrodynamics and is furthermore shown to deliver shear-sensitive biomolecules--plasmid DNA and antibodies as exemplars of future pulmonary gene and vaccination therapies--undamaged in the nebulized mist. Altogether, the approach demonstrates a means to offer truly micro-scale microfluidics devices in a handheld, battery powered SAW nebulization device.


Drug Delivery Systems , Lab-On-A-Chip Devices , Microfluidic Analytical Techniques , Nebulizers and Vaporizers , Sound , Antibodies/chemistry , DNA/chemistry , Drug Delivery Systems/instrumentation , Drug Delivery Systems/methods , Microfluidic Analytical Techniques/instrumentation , Microfluidic Analytical Techniques/methods , Plasmids/chemistry
19.
Rev Sci Instrum ; 85(2): 025104, 2014 Feb.
Article En | MEDLINE | ID: mdl-24593393

Thermal noise spectra of nanomechanical resonators are used widely to characterize their physical properties. These spectra typically exhibit a Lorentzian response, with additional white noise due to extraneous processes. Least-squares fits of these measurements enable extraction of key parameters of the resonator, including its resonant frequency, quality factor, and stiffness. Here, we present general formulas for the uncertainties in these fit parameters due to sampling noise inherent in all thermal noise spectra. Good agreement with Monte Carlo simulation of synthetic data and measurements of an Atomic Force Microscope (AFM) cantilever is demonstrated. These formulas enable robust interpretation of thermal noise spectra measurements commonly performed in the AFM and adaptive control of fitting procedures with specified tolerances.

20.
Article En | MEDLINE | ID: mdl-24580352

Acoustic streaming underpins an exciting range of fluid manipulation phenomena of rapidly growing significance in microfluidics, where the streaming often assumes the form of a steady, laminar jet emanating from the device surface, driven by the attenuation of acoustic energy within the beam of sound propagating through the liquid. The frequencies used to drive such phenomena are often chosen ad hoc to accommodate fabrication and material issues. In this work, we seek a better understanding of the effects of sound frequency and power on acoustic streaming. We present and, using surface acoustic waves, experimentally verify a laminar jet model that is based on the turbulent jet model of Lighthill, which is appropriate for acoustic streaming seen at micro- to nanoscales, between 20 and 936 MHz and over a broad range of input power. Our model eliminates the critically problematic acoustic source singularity present in Lighthill's model, replacing it with a finite emission area and enabling determination of the streaming velocity close to the source. At high acoustic power P (and hence high jet Reynolds numbers ReJ associated with fast streaming), the laminar jet model predicts a one-half power dependence (U∼P1/2∼ ReJ) similar to the turbulent jet model. However, the laminar model may also be applied to jets produced at low powers-and hence low jet Reynolds numbers ReJ-where a linear relationship between the beam power and streaming velocity exists: U∼P∼ReJ2. The ability of the laminar jet model to predict the acoustic streaming behavior across a broad range of frequencies and power provides a useful tool in the analysis of microfluidics devices, explaining peculiar observations made by several researchers in the literature. In particular, by elucidating the effects of frequency on the scale of acoustically driven flows, we show that the choice of frequency is a vitally important consideration in the design of small-scale devices employing acoustic streaming for microfluidics.

...