Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Endod ; 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38964675

RESUMEN

INTRODUCTION: This study aimed to evaluate the dynamic cyclic fatigue resistance of Reciproc® Blue files subjected to brushing motion. METHODS: Twenty Reciproc® Blue files (R25, VDW, Munich, Germany) were employed for chemical-mechanical preparation in root canals of 3D printed replicas of mandibular molars. The instruments were divided into two groups (n=10): Group BM, instrumentation with brushing motions; Group WBM, instrumentation without brushing motions. Subsequently, the same instruments underwent cyclic fatigue testing using artificial canals consisting of a stainless-steel plate and an apical segment with a 45° curvature. Data regarding the time to fracture, number of cycles to fracture (NCF), and length of the fractured fragment were collected and subjected to statistical analysis using the t-test or Mann-Whitney test, with a significance level of 5%. Additionally, the fractured fragments were examined under a scanning electron microscope. RESULTS: No statistical differences were observed between the groups in terms of time to fracture (p<0.05), NCF (p<0.05), and length of the fractured fragment (p<0.05). CONCLUSION: The brushing motion did not affect the dynamic cyclic fatigue resistance of Reciproc Blue files.

2.
Acta Odontol Latinoam ; 37(1): 34-39, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38920124

RESUMEN

The remaining filling material after retreatment can harbor bacteria and organic tissues that can influence the outcome of the therapy. AIM: The aim of this study was to evalúate, by micro-CT, the amount of filling material remaining in the root canal after its removal using WaveOne Gold or ProDesign RT. MATERIAL AND METHOD: Forty human mandibular canines were instrumented with the ProTaper Next system up to the X2 instrument (25.06) and filled with gutta-percha cones and AHPlus. Teeth were divided into 2 groups (n=20): WaveOne Gold 25.07 (WOG) and ProDesign RT 25.08 (PRT) for filling removal, after which they were scanned in a micro-CT device to quantify the volume of remaining filling material. The data were subjected to log 10 transformation, Student 's t-test was performed to account for multiple observationsper sample, significance was set at 5%. RESULTS: Student 's t-test showed that there was no difference between the two systems regarding the volume of remaining filling material in the thirds: apical (p = 0.392), middle (p = 0.065), or cervical (p = 0.918). CONCLUSIÓN: Remaining filling material was present in all groups and both systems were similar in removing root filling material in mandibular canines.


A permanencia de material obturador após o retratamento pode abrigar bactérias e tecidos orgánicos que podem influenciar o resultado da terapia. OBJETIVO: O objetivo deste estudo foi avaliar, por micro-CT, a quantidade de material obturador remanescente no canal radicular após a desobturagdo com WaveOne Gold e ProDesign RT. MATERIAL E MÉTODO: Quarenta caninos inferiores humanos foram instrumentados com o sistema ProTaper Next até o instrumento X2 (25.06) e obturados com cones de guta-percha e AHPlus. Os dentes foram divididos em dois grupos (n=20): WaveOne Gold 25.07 (WOG) e ProDesign RT 25.08 (PRT) e escaneados em micro-CT para quantificagdo do volume de material obturador remanescente. Os dados foram submetidos á transformando log 10, o teste t de Student foi realizado para contabilizar múltiplas observagoes por amostra, a significáncia foi fixada em 5%. RESULTADOS: O teste t de Student mostrou que ndo houve diferenga no volume de material obturador remanescente entre os dois sistemas nos tergos: apical (p = 0,392), médio (p = 0,065) ou cervical (p = 0,918). CONCLUSÃO: O material obturador remanescente estavapresente em todos os grupos e ambos os sistemas foram semelhantes na remogdo do material obturador radicular nos caninos inferiores.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Microtomografía por Rayos X , Humanos , Diente Canino/diagnóstico por imagen , Técnicas In Vitro , Diseño de Equipo
3.
J Endod ; 50(5): 590-595, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38428806

RESUMEN

INTRODUCTION: The aim of this observational study was to evaluate bone growth at the recipient site of autotransplanted teeth using cone-beam computed tomography (CBCT) images and to compare it to the control tooth. METHODS: Bone growth was measured on CBCT images obtained from the anterior region of the maxilla, which received a single transplant of immature premolars due to early loss of the central incisor. The results were compared to the bone growth of contralateral central incisor that served as control. The sample consisted of 13 autotransplanted teeth and 13 control teeth. It was determined the thickness of the buccal bone of the marginal ridge, the thickness of the palatal bone of the marginal ridge, the height of the maxillary bone, and the thickness of the maxillary bone at its mid-height. The measurements were analyzed statistically, adopting a significance level of 5%. RESULTS: The mean interval between the dental autotransplantation surgery and the CBCT scan was 16.2 years. The mean thickness of the buccal bone of the marginal ridge, thickness of the palatal bone of the marginal ridge, height of the maxillary bone, and thickness of the maxillary bone at its mid-height were, respectively, 0.85, 0.94, 19.6, and 8.85 mm for autotransplanted teeth and 0.79, 1.09, 18.88, and 8.5 mm for control teeth. There were no significant differences in the bone measurements between autotransplanted and control teeth (P > .05). CONCLUSIONS: The growth of maxillary bone in the region that received the autotransplanted tooth was proportional to that of maxillary bone that supports the contralateral tooth. Thus, autogenous transplantation is efficient in maintaining the bone architecture at the recipient site.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Trasplante Autólogo , Humanos , Tomografía Computarizada de Haz Cónico/métodos , Masculino , Femenino , Maxilar/diagnóstico por imagen , Adolescente , Diente Premolar/diagnóstico por imagen , Diente Premolar/trasplante , Niño , Incisivo/diagnóstico por imagen , Proceso Alveolar/diagnóstico por imagen
4.
J Endod ; 50(7): 982-988, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38537783

RESUMEN

INTRODUCTION: In an effort to enhance the quality of mechanized endodontic instruments, various thermal treatment methods, and design modifications have been suggested. However, upon evaluation, these endodontic instruments may exhibit microscopic irregularities. The objective of this in vitro study was to analyze the cutting capacity, surface finish, and mechanical properties of Nickel-Titanium 25/.04 Rotate (VDW GmbH, Munich, Germany) and LOGIC 2 (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brazil) rotary instruments. METHODOLOGY: Twenty rotary instruments were divided into 2 groups: GR, the group with ROTATE instruments (n = 10); and GL2, the group with LOGIC 2 instruments (n = 10). They were evaluated for roughness, using a profilometer, for bending resistance, buckling resistance, and cutting capacity using a universal testing machine, as well as for torsional strength (torque and angular deflection) using a torquemeter. The instruments were visualized before and after the mechanical tests through scanning electron microscopy. RESULTS: GR showed better surface finish in terms of roughness, greater cutting capacity, and greater angular deflection than GL2 (P < .05). However, GL2 showed better flexibility than GR (P < .05). GL2 and GR did not show statistically significant differences in terms of buckling and torque (P > .05). CONCLUSION: The ROTATE and LOGIC 2 rotary instruments differed in their surface finish, cutting capacity, and mechanical properties, except for their buckling resistance and required fracture torque.


Asunto(s)
Níquel , Preparación del Conducto Radicular , Propiedades de Superficie , Titanio , Níquel/química , Titanio/química , Preparación del Conducto Radicular/instrumentación , Instrumentos Dentales , Diseño de Equipo , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Torque , Análisis del Estrés Dental
5.
J Endod ; 50(5): 619-626, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38311114

RESUMEN

INTRODUCTION: Determination of the glide path is recommended before using rotary instruments. This study aimed to evaluate the dynamic cyclic fatigue resistance of new and used glider rotary instruments in up to 6 root canals. METHODS: Seventy-two TruNatomy Glider files were used for the preparation of root canals of extracted lower molars, which were then submitted to the dynamic cyclic fatigue test carried out in a curved metallic artificial canal. The instruments were divided into 4 groups (n = 18): Control group, new instruments without any use in the root canal; Group 2U, instruments used in 2 mesial canals; Group 4U, instruments used in 4 mesial canals; Group 6U, instruments used in 6 mesial canals. The time to failure (TF) of the instrument was recorded, and the number of cycles to failure (NCF) was calculated. The data were submitted to 1-way analysis of variance and to the Games-Howell test for multiple comparisons, adopting a significance level of 5%. RESULTS: TF and NCF were significantly affected by the number of file uses. The Games-Howell test revealed that TF and NCF were significantly greater in the control group than in Group 4U. In Group 2U, TF and NCF were intermediate and not significantly different from the control group. Group 6U had significantly lower TF and NCF than all other groups. CONCLUSION: The TruNatomy Glider can be used as a glide path for up to 2 mesial canals of mandibular molars, whereas its use on 4 or 6 root canals is not suggested.


Asunto(s)
Falla de Equipo , Preparación del Conducto Radicular , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Humanos , Instrumentos Dentales , Diseño de Equipo , Técnicas In Vitro , Diente Molar , Análisis del Estrés Dental , Cavidad Pulpar , Ensayo de Materiales
6.
Int Endod J ; 57(6): 700-712, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38404175

RESUMEN

AIM: To evaluate the influence of different preparation tapers on the reduction in planktonic bacteria and biofilms of Enterococcus faecalis and Candida albicans in the apical third (4 mm) of the mesial roots of mandibular molars, correlating decontamination with canal shape. METHODOLOGY: After microtomography analysis for morphological standardization of the canals, 48 mandibular molar roots, each containing two canals (96 canals), were contaminated with E. faecalis and C. albicans and divided into four groups (n = 11) for canal instrumentation using ProDesign Logic 2 files with different tapers G (.03): # 25.03; G (.04): # 25.04; G (.05): # 25.05; and G (.06): # 25.06 and irrigation with 2.5% sodium hypochlorite. Four roots were examined under a scanning electron microscope (SEM) to qualitatively assess biofilm formation. Eight roots were used as the negative control group (samples were not contaminated). Bacteriological samples were taken exclusively from the apical third of the roots before and after chemical-mechanical preparation and bacterial counts were determined (CFU/mL). The final micro-CT scan was used to quantify the volume variation and unprepared canal area in the apical third. Statistical analysis was performed using the Kruskal-Wallis, Student-Newman-Keuls and Wilcoxon tests for analysis of microbiological data. anova and the Tukey or Games-Howell test were used for analysis of micro-CT data and Spearman's test for correlations (α = 5%). RESULTS: All groups showed a significant reduction in bacteria (p < .05), with no statistically significant difference between groups. There was no significant difference in per cent volume increase between groups. The unprepared area (Δ%) was affected by the file used (p = .026) and was significantly lower for G (.06) compared to G (.03). There was no statistically significant correlation among bacterial reduction, volume and unprepared area (p > .05). CONCLUSION: The different preparation tapers influenced root canal shaping in the apical third but did not improve decontamination in this region.


Asunto(s)
Biopelículas , Candida albicans , Cavidad Pulpar , Enterococcus faecalis , Preparación del Conducto Radicular , Microtomografía por Rayos X , Microtomografía por Rayos X/métodos , Humanos , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Candida albicans/aislamiento & purificación , Candida albicans/fisiología , Cavidad Pulpar/microbiología , Cavidad Pulpar/diagnóstico por imagen , Hipoclorito de Sodio/uso terapéutico , Hipoclorito de Sodio/farmacología , Microscopía Electrónica de Rastreo , Diente Molar/microbiología , Plancton , Irrigantes del Conducto Radicular/administración & dosificación , Irrigantes del Conducto Radicular/uso terapéutico , Técnicas In Vitro , Ápice del Diente/microbiología , Ápice del Diente/diagnóstico por imagen
7.
Int Endod J ; 57(5): 520-532, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38279778

RESUMEN

AIM: The anaesthetic success rate of an inferior alveolar nerve block (IANB) in mandibular molars with irreversible symptomatic pulpitis can be low, and postoperative pain control in teeth with this diagnosis can be challenging. This study aimed to evaluate the influence of preemptive use of dexamethasone and oral potassium diclofenac on the success of IANB. The influence of these drugs on the intensity of postoperative pain was assessed as a secondary outcome. METHODOLOGY: Eighty-four patients with mandibular molars diagnosed with irreversible symptomatic pulpitis recorded preoperative pain intensity using a cold thermal test and a modified Numerical Rating Scale (mNRS). Sixty minutes before the anaesthetic procedure, patients were randomly assigned to one of three groups based on the medication they received: dexamethasone (4 mg), diclofenac potassium (50 mg), or placebo. All patients received IANB with 4% articaine (1:200 000 epinephrine), and 15 min later, they were evaluated for pain intensity using the cold thermal test. Anaesthetic success was analysed. The pain intensity was then recorded, and endodontic treatment and provisional restoration of the tooth were executed in a single session. Patients were monitored for 6, 12, 24, 48 and 72 h using the mNRS to assess the intensity of postoperative pain. RESULTS: There was a statistically significant increase in anaesthetic success when 4 mg dexamethasone (39.3%) or 50 mg diclofenac potassium (21.4%) was used compared to the placebo group (3.6%) (p < .001), with no significant difference between the two drugs. Regarding postoperative pain, dexamethasone was superior to placebo at 6 h (p < .001), with diclofenac having an intermediate behaviour, not differing between dexamethasone and placebo (p > .05). There was no significant difference amongst the groups at 12 h (p > .05). At 24, 48 and 72 h, the effectiveness of dexamethasone and diclofenac were comparable, and both were superior to placebo (p < .001). CONCLUSION: The use of dexamethasone or diclofenac potassium was favourable in terms of increasing the success rate of inferior alveolar nerve block in cases of mandibular molars with irreversible symptomatic pulpitis and decreased the occurrence of postoperative pain when compared to the use of a placebo.


Asunto(s)
Anestesia Dental , Anestésicos , Bloqueo Nervioso , Pulpitis , Humanos , Anestesia Dental/métodos , Anestésicos/farmacología , Anestésicos Locales , Antiinflamatorios/farmacología , Dexametasona/farmacología , Diclofenaco/farmacología , Método Doble Ciego , Lidocaína , Nervio Mandibular , Diente Molar/cirugía , Bloqueo Nervioso/métodos , Dolor Postoperatorio/tratamiento farmacológico , Dolor Postoperatorio/prevención & control , Pulpitis/cirugía
8.
Aust Endod J ; 50(1): 140-147, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38152976

RESUMEN

The objective of the study was to investigate the 5.25% sodium hypochlorite (NaOCl) penetration into the dentinal tubules after different irrigation methods. Seventy canines were stained with 1% crystal violet and divided into groups (n = 20): GEC-EasyClean; GPUI-E1 Irrisonic ultrasonic insert; GXP-XP-Endo finisher; GPC-conventional irrigation and GNC-stained tooth without irrigation. Axial sections (16×) were assessed and irrigant penetration was quantified as a bleaching halo on the surface of the apical, middle and coronal third. In the apical third, GPUI promoted greater NaOCl penetration (p < 0.05). GXP was better than GEC (p < 0.05), as was GPC (p > 0.05). The GPUI and GXP groups were similar in the middle and coronal third (p > 0.05). GPUI and GXP showed better results than GEC (p < 0.05). GPUI was more effective in the apical third and like GXP in the cervical and middle third.


Asunto(s)
Dentina , Irrigantes del Conducto Radicular , Irrigación Terapéutica/métodos , Hipoclorito de Sodio , Ultrasonido/métodos
9.
Braz Dent J ; 34(4): 44-53, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37909641

RESUMEN

This study aimed to evaluate the temperature changes that the different methods of agitation of irrigants promote on the external dental root surface. Nine extracted human lower premolars were standardized by cone-beam computed tomography and used. The root canal was instrumented with a Reciproc 40.06 file. Temperature measurement was performed using K-type thermocouple sensors attached to the middle, cervical, and apical thirds of the teeth. The teeth had their roots immersed in distilled water at 37ºC, which were distributed into 3 experimental groups according to the mechanical agitation methods to be studied. US Group (n=3), Irrisonic Ultrasonic Tip activated through ultrasound; EC Group (n=3), Easyclean Tip coupled to a contra-angle low-speed handpiece; XP Group (n=3), XP-endo Finisher file coupled to an endodontic electrical motor. Temperature measurements were performed simultaneously with agitation and irrigation of intracanal irrigants. Statistical analysis was performed using SPSS software with a significance level of 5%. For multiple comparisons, the Tukey test was used. The association between mechanical agitation methods and root third was statistically significant. Regarding the temperatures recorded on the external surface of the roots, the ultrasonic tip was significantly higher than the XP-endo Finisher file and the Easyclean tip, which did not differ from each other. Regarding the ultrasonic tip, the external temperature in the middle third (39.46ºC) of the root was significantly lower than in the cervical (40.41ºC) and apical third (40.53ºC). None of the agitation methods of irrigants studied presented heating above 47ºC, and their use is safe for periodontal tissues.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Humanos , Temperatura , Preparación del Conducto Radicular/métodos , Irrigantes del Conducto Radicular , Tratamiento del Conducto Radicular
10.
Braz. dent. j ; 34(4): 44-53, July-Aug. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1520339

RESUMEN

Abstract This study aimed to evaluate the temperature changes that the different methods of agitation of irrigants promote on the external dental root surface. Nine extracted human lower premolars were standardized by cone-beam computed tomography and used. The root canal was instrumented with a Reciproc 40.06 file. Temperature measurement was performed using K-type thermocouple sensors attached to the middle, cervical, and apical thirds of the teeth. The teeth had their roots immersed in distilled water at 37ºC, which were distributed into 3 experimental groups according to the mechanical agitation methods to be studied. US Group (n=3), Irrisonic Ultrasonic Tip activated through ultrasound; EC Group (n=3), Easyclean Tip coupled to a contra-angle low-speed handpiece; XP Group (n=3), XP-endo Finisher file coupled to an endodontic electrical motor. Temperature measurements were performed simultaneously with agitation and irrigation of intracanal irrigants. Statistical analysis was performed using SPSS software with a significance level of 5%. For multiple comparisons, the Tukey test was used. The association between mechanical agitation methods and root third was statistically significant. Regarding the temperatures recorded on the external surface of the roots, the ultrasonic tip was significantly higher than the XP-endo Finisher file and the Easyclean tip, which did not differ from each other. Regarding the ultrasonic tip, the external temperature in the middle third (39.46ºC) of the root was significantly lower than in the cervical (40.41ºC) and apical third (40.53ºC). None of the agitation methods of irrigants studied presented heating above 47ºC, and their use is safe for periodontal tissues.


Resumo Este estudo teve como objetivo avaliar as mudanças de temperatura que os diferentes métodos de agitação de irrigantes promovem na superfície externa da raiz dentária. Nove pré-molares humanos extraídos foram padronizados por tomografia computadorizada de feixe cônico e usados. O canal radicular foi instrumentado com uma lima Reciproc 40.06 de 25 mm. A medição da temperatura foi realizada usando sensores termopares do tipo K fixados nos terços médio, cervical e apical dos dentes. Os dentes tiveram suas raízes imersas em água destilada a 37ºC, as quais foram distribuídas em 3 grupos experimentais de acordo com os métodos de agitação mecânica a serem estudados. Grupo US (n=3), Ponta Irrisonic Ultrasonic ativado por ultrassom; Grupo EC (n=3), Ponta Easyclean acoplada a um contra-ângulo de baixa rotação; Grupo XP (n=3), Lima XP-endo Finisher acoplada a um motor elétrico endodôntico. As medições de temperatura foram realizadas simultaneamente com agitação e irrigação de irrigantes intracanal. A análise estatística foi realizada no software SPSS com nível de significância de 5%. Para comparações múltiplas, foi utilizado o teste de Tukey. A associação entre métodos de agitação mecânica e terço radicular foi estatisticamente significativa. Em relação às temperaturas registradas na superfície externa das raízes, a ponta ultrassônica foi significativamente maior que a lima XP-endo Finisher e a ponta Easyclean, que não diferiram entre si. Com relação à ponta ultrassônica, a temperatura externa no terço médio (39,46ºC) da raiz foi significativamente menor do que nos terços cervical (40,41ºC) e apical (40,53ºC). Nenhum dos métodos de agitação dos irrigantes estudados (Irrisonic, XP-endo Finisher e Easyclean) apresentou aquecimento acima de 47ºC, sendo seu uso seguro para os tecidos periodontais.

11.
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1535289

RESUMEN

Introduction: the in vitro study compared the dynamic cyclic fatigue resistance of 3 reciprocating NiTi files with heat treatment. Methods: we distributed 30 new endodontic files in three groups. The endodontic files selected for this experiment were: AF Blue R3 25/06 (AFB) (Fanta Dental, Shanghai, China), X1 Blue File 25/06 (X1B) (MK Life, Porto Alegre, RS, Brazil), and Reciproc Blue 08/25 (RB) (VDW, Munich, Germany. We measured the time to file fractureand the length of the fractured fragment. ANOVA analysis was used, followed by the Tukey test for multiple comparisons, with a significance level of 5% (P < 0,05). Results: the mean time in seconds until the file fractured was 170.7 ±15,1 for AFB files, 110,4 ±26,8 for X1B, and 163,3 ±22,9 for RB files. This difference was statistically significant when comparing X1B to AFB (p: 0,000) and X1B to RB (p: 0,000). However, there are no statistically significant differences between RB and AFB (p:0,739). Conclussions: this study found that RB and AFB files exhibit similar resistance to cyclic fatigue.


Introducción: el estudio in vitro comparó la resistencia a la fatiga cíclica dinámica de 3 limas NiTi recíprocas con tratamiento térmico. Métodos: distribuimos 30 limas endodónticas nuevas en tres grupos. Las limas endodónticas seleccionadas para este experimento fueron: AF Blue R3 25/06 (AFB) (Fanta Dental, Shanghai, China), X1 Blue File 25/06 (X1B) (MK Life, Porto Alegre, RS, Brasil), y Reciproc Blue 08/25 (RB) (VDW, Munich, Alemania. Se midió el tiempo transcurrido hasta la fractura de la lima y la longitud del fragmento fracturado. Se utilizó el análisis ANOVA, seguido de la prueba de Tukey para comparaciones múltiples, con un nivel de significación del 5% (P < 0.05). Resultados: el tiempo medio en segundos hasta la fractura de la lima fue de 170.7 ±15.1 para las limas AFB, 110.4 ±26.8 para las X1B y 163.3 ±22.9 para las RB. Esta diferencia fue estadísticamente significativa al comparar X1B con AFB (p: 0.000) y X1B con RB (p: 0.000). Sin embargo, no hay diferencias estadísticamente significativas entre RB y AFB (p:0.739). Conclusiones: en este estudio se ha comprobado que las limas RB y AFB presentan una resistencia similar a la fatiga cíclica.

12.
Braz Dent J ; 34(2): 21-26, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37194853

RESUMEN

The present study evaluated the actual rotational speed of three different endodontic motors compared to the values provided by the manufacturers. A total of three endodontic motors (X-Smart Plus, VDW.Silver, and iRoot) were tested at 400 rpm and 800 rpm and 2 N/cm2 torque. The kinematics of the devices was recorded by using a custom angle-measuring disc with a 50-mm diameter attached to the handpiece provided by the manufacturer, whereas their movement was captured by a high-speed camera at 2,400 frames per second, 800 x 800 pixel-resolution and distance of 0.3 m from the target object. Statistical analysis was performed at a significance level of 5%. At 400 rpm, the iRoot motor had a value of 17.94 rpm above that indicated by the manufacturer, which was significantly different from those of X-Smart Plus (5.20 rpm below that indicated by the manufacturer) and VDW.Silver (0.62 rpm above that indicated by the manufacturer) motors (P < 0.05). At 800 rpm, the iRoot motor had a value of 51.34 rpm below that indicated by the manufacturer, whereas the X-Smart Plus motor had a value of 13.00 rpm below that indicated by the manufacturer (P > 0.05). The VDW.Silver motor statistically differed from the iRoot and X-Smart Plus ones, showing a value of 1.68 rpm above that indicated by the manufacturer. In conclusion, the X-Smart Plus, VDW.Silver, and iRoot motors showed lower variations in the rotational speed values compared to those reported by their manufacturers. The endodontic motors presented different behaviors between them, with the VDW.Silver motor presents the most accurate values and the iRoot presents the most divergent values.


Asunto(s)
Preparación del Conducto Radicular , Plata , Fenómenos Biomecánicos , Diseño de Equipo , Torque
13.
Braz. dent. j ; 34(2): 21-26, Mar.-Apr. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1439577

RESUMEN

Abstract The present study evaluated the actual rotational speed of three different endodontic motors compared to the values provided by the manufacturers. A total of three endodontic motors (X-Smart Plus, VDW.Silver, and iRoot) were tested at 400 rpm and 800 rpm and 2 N/cm2 torque. The kinematics of the devices was recorded by using a custom angle-measuring disc with a 50-mm diameter attached to the handpiece provided by the manufacturer, whereas their movement was captured by a high-speed camera at 2,400 frames per second, 800 x 800 pixel-resolution and distance of 0.3 m from the target object. Statistical analysis was performed at a significance level of 5%. At 400 rpm, the iRoot motor had a value of 17.94 rpm above that indicated by the manufacturer, which was significantly different from those of X-Smart Plus (5.20 rpm below that indicated by the manufacturer) and VDW.Silver (0.62 rpm above that indicated by the manufacturer) motors (P < 0.05). At 800 rpm, the iRoot motor had a value of 51.34 rpm below that indicated by the manufacturer, whereas the X-Smart Plus motor had a value of 13.00 rpm below that indicated by the manufacturer (P > 0.05). The VDW.Silver motor statistically differed from the iRoot and X-Smart Plus ones, showing a value of 1.68 rpm above that indicated by the manufacturer. In conclusion, the X-Smart Plus, VDW.Silver, and iRoot motors showed lower variations in the rotational speed values compared to those reported by their manufacturers. The endodontic motors presented different behaviors between them, with the VDW.Silver motor presents the most accurate values and the iRoot presents the most divergent values.


Resumo O presente estudo avaliou a real velocidade rotacional de três diferentes motores endodônticos comparados aos valores fornecidos pelos fabricantes. Um total de três motores endodônticos (X-Smart Plus, VDW.Silver e iRoot) foram testados a 400 rpm e 800 rpm e torque de 2 N/cm2. A cinemática dos dispositivos foi verificada utilizando-se um disco customizado de 50 mm de diâmetro acoplado ao contra ângulo fornecido pelo fabricante e o movimento foi capturado através de uma câmera ajustada em 2400 quadros por segundo com resolução de 800 x 800 pixels distante 0,3 m do objeto alvo. A análise estatística foi realizada com nível de significância de 5%. A 400 rpm, o motor iRoot apresentou 17,94 rpm acima do indicado pelo fabricante, sendo o valor significativamente diferente do X-Smart Plus (5,20 rpm abaixo do indicado pelo fabricante) e VDW.Silver (0.62 rpm acima do indicado pelo fabricante) (P > 0,05). A 800 rpm, iRoot apresentou 51.34 rpm abaixo do indicado pelo fabricante e X-Smart Plus 13,00 rpm abaixo do indicado pelo fabricante (P > 0,05). VDW.Silver foi estatisticamente diferente de iRoot e X-Smart Plus, apresentando 1,68 rpm acima do indicado pelo fabricante. Concluiu-se que os motores X-Smart Plus, VDW.Silver e iRoot apresentaram baixa variação na velocidade rotacional quando comparada ao fornecido pelo fabricante. Os motores endodônticos apresentaram diferentes comportamentos entre eles, sendo que o motor VDW.Silver apresentou valores mais acurados enquanto o iRoot foi o mais divergente.

14.
Braz. j. oral sci ; 22: e231400, Jan.-Dec. 2023. ilus
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1524336

RESUMEN

Aim: This study aimed to assess the shaping ability of Reciproc Blue in the apical third and apical foramen of moderately curved canals at different working lengths (WLs), by micro-computed tomography. Methods: Thirty-six mesial roots (mesiobuccal and mesiolingual canals) were included, each with 2 separate root canals and independent apical foramina, according to type IV of Vertucci's classification of first and second mandibular molars. The canals were instrumented at three different WLs: G-1, 1mm short of the major apical foramen; G0, at the major apical foramen; G+1, 1mm beyond the major apical foramen. The groups were assessed for changes in root canal volume and untouched wall area in the apical third. Groups G0 and G+1 were also compared for percentage of untouched walls at the apical foramen. One-way ANOVA (post hoc Tukey test) and Student's t-test adopted a 5% level of significance. Results: Root canal volumes (mm3) in the apical third were 22.86±10.46, 44.48±24.91, and 55.71±21.32 in G-1, G0 and G+1, respectively. G-1 volume following instrumentation increased significantly less than that of G0 or G+1 (P>.05); G0 did not differ from G+1. The percentage of untouched wall area in the apical third did not differ among the three groups (P>.05). G0 and G+1 did not differ regarding untouched walls in the major apical foramem walls. Conclusion: Extending the WL from 1mm short of the apical foramen to a point at and beyond the WL increases the apical third volume without increasing the prepared area. Untouched surface areas of the apical foramen were not modified by instrumentation at or beyond the foramen


Asunto(s)
Periodontitis Periapical , Tratamiento del Conducto Radicular , Ápice del Diente , Cavidad Pulpar , Microtomografía por Rayos X
15.
Braz Dent J ; 33(6): 28-35, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36477962

RESUMEN

This study assessed 3 endodontic motors, X-Smart Plus (Dentsply Sirona, Ballaigues, Switzerland), VDW.Silver Reciproc (VDW GmbH, München, Germany) and, iRoot (Bassi Endodontics, Belo Horizonte, Brazil) in 2 different reciprocating settings. The movements evaluated were 170° in counter-clockwise (CCW) and 50° in clockwise (CW) at 350 RPM, and 150° CCW and 30° CW at 300 RPM. For the X-Smart Plus and VDW Silver the settings used were the ones in the motor library. For the iRoot, the motor was adjusted to the angles of the study. A customized optic target was attached to the contra-angle of the motor and the movements were recorded with a high-resolution camera (K2 DistaMaxTM Long-Distance Microscope System, Infinity Photo-Optical Company, Colorado, EUA) at 2,400 frames per second (FPS). The images were analyzed with the Vision Research software (Inc. Headquarters, Wayne, New Jersey, EUA). The following kinematic parameters were assessed: CCW angle, CW angle, speed (RPM) at both directions, and, standstill time at each change of directions. The Intraclass Correlation Coefficient (ICC) and Kruskal-Wallis (method of Dunn) were used at a significant level of 5%. There was no statistically significant difference among the motors at the 150°/30° setting (P > .05); the iRoot was the least reliable at the 170°/50° setting for CCW angle, speed, and net angle parameters (P < 0.05). The standstill time of all motors in both directions was identical. None of the motors were able to reproduce faithfully the set movements. The iRoot motor presented a higher discrepancy when compared to X-Smart and VDW Silver.


Asunto(s)
Plata , Brasil
16.
Restor Dent Endod ; 47(4): e37, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36518609

RESUMEN

Objectives: This study aimed to evaluate the prevalence of apical periodontitis (AP) in the mesiobuccal roots of root canal-treated maxillary molars. Materials and Methods: One thousand cone-beam computed tomography images of the teeth were examined by 2 dental specialists in oral radiology and endodontics. The internal anatomy of the roots, Vertucci's classification, quality of root canal treatment, and presence of missed canals were evaluated; additionally, the correlation between these variables and AP was ascertained. Results: A total of 1,000 roots (692 first molars and 308 second molars) encompassing 1,549 canals were assessed, and the quality of the root canal filling in the majority (56.9%) of the canals was satisfactory. AP was observed in 54.4% of the teeth. A mesiolingual canal in the mesiobuccal root (MB2 canal) was observed in 54.9% of the images, and the majority (83.5%) of these canals were not filled. Significant associations were observed between the presence of an MB2 canal and the quality of the root canal filling and the presence of AP. Conclusions: AP was detected in more than half of the images. The MB2 canals were frequently missed or poorly filled.

17.
Braz. dent. j ; 33(6): 28-35, Nov.-Dec. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1420558

RESUMEN

Abstract This study assessed 3 endodontic motors, X-Smart Plus (Dentsply Sirona, Ballaigues, Switzerland), VDW.Silver Reciproc (VDW GmbH, München, Germany) and, iRoot (Bassi Endodontics, Belo Horizonte, Brazil) in 2 different reciprocating settings. The movements evaluated were 170° in counter-clockwise (CCW) and 50° in clockwise (CW) at 350 RPM, and 150° CCW and 30° CW at 300 RPM. For the X-Smart Plus and VDW Silver the settings used were the ones in the motor library. For the iRoot, the motor was adjusted to the angles of the study. A customized optic target was attached to the contra-angle of the motor and the movements were recorded with a high-resolution camera (K2 DistaMaxTM Long-Distance Microscope System, Infinity Photo-Optical Company, Colorado, EUA) at 2,400 frames per second (FPS). The images were analyzed with the Vision Research software (Inc. Headquarters, Wayne, New Jersey, EUA). The following kinematic parameters were assessed: CCW angle, CW angle, speed (RPM) at both directions, and, standstill time at each change of directions. The Intraclass Correlation Coefficient (ICC) and Kruskal-Wallis (method of Dunn) were used at a significant level of 5%. There was no statistically significant difference among the motors at the 150°/30° setting (P > .05); the iRoot was the least reliable at the 170°/50° setting for CCW angle, speed, and net angle parameters (P < 0.05). The standstill time of all motors in both directions was identical. None of the motors were able to reproduce faithfully the set movements. The iRoot motor presented a higher discrepancy when compared to X-Smart and VDW Silver.


Resumo Este estudo avaliou 3 motores endodônticos, X-Smart Plus (Dentsply Sirona, Ballaigues, Suíça), VDW.Silver Reciproc (VDW GmbH, Munique, Alemanha) e iRoot (Bassi Endodontics, Belo Horizonte, Brasil) em 2 diferentes ajustes de movimento reciprocante. Os movimentos analisados foram: 170° em sentido anti-horário (CCW) e 50° em sentido horário (CW) a 350 RPM, e 150° CCW e 30° CW a 300 RPM. Para os motores X-Smart Plus e VDW Silver os ajustes usados foram os que se apresentam nos ajustes pré-definidos dos motores. Para o iRoot o motor foi ajustado para os ângulos do estudo. Um alvo ótico customizado foi preso ao contra ângulo do motor e os movimentos foram gravados com uma câmara de alto resolução (K2 DistaMaxTM Long-Distance Microscope System, Infinity Photo-Optical Company, Colorado, EUA) a 2.400 quadros por segundo (FPS). As imagens foram analisadas com o sotware Vision Research (Inc. Headquarters, Wayne, Nova Jersey, USA). Os seguintes parâmetros de cinemática foram avaliados: ângulo anti-horário, ângulo horário, ângulo líquido, velocidade (RPM) em ambas direções e tempo de parada a cada mudança de direção. O Coeficiente de Correlação Intraclasse (ICC) e o teste de Kruskal-Wallis (método de Dunn) foram usados com nível de significâncias de 5%. Não houve diferença estatisticamente significante entre os motores no ajuste de 150°/30° (P > .05); o motor iRoot foi o menos confiável no ajuste de 170°/50° para o ângulo anti-horário, velocidade e ângulo líquido (P < 0.05). O tempo de parada em todos os motores foi idêntico em ambas as direções. Nenhum dos motores foi capaz de reproduzir fielmente os movimentos. O motor iRoot apresentou maior discrepância quando comparado com o X-Smart Plus e VDW Silver.

18.
Eur J Dent ; 16(3): 580-584, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34937108

RESUMEN

OBJECTIVE: This study evaluated the dynamic cyclic fatigue resistance of the XP-Endo Shaper (XPS), associated with chlorhexidine digluconate (CHX) or sodium hypochlorite (NaOCl) in two different formulations: gel (G) or liquid (L). MATERIALS AND METHODS: Sixty XPS were used in an artificial stainless-steel canal, and the files were fully immersed in the irrigating solution throughout the experiment until the fracture. The files were divided into six groups (n = 10) based on the irrigation solution used: NaOCl(L), NaOCl(G), CHX(L), CHX(G), natrosol gel (NAT) (control), and lubricating oil (LO) (control). The artificial canal was manufactured 1.5 mm wide, 20 mm long, and, 3.5 mm deep with a straight cervical segment measuring 14.29 mm; an apical segment of 4.71 mm with 3 mm radius; and 90 degrees of curvature apical 1 mm long straight segment. Resistance to cyclic fatigue was determined by recording the number of cycles to fracture (NCF). RESULTS: The CHX(G), CHX(L), and OIL (LO) groups showed no significant difference between them and presented longer time to fracture (p > 0.05). NaOCl(L) shows the lowest NCF without significant differences between NaOCl(G) and NAT. The NCF of the NaOCl(G) was statistically similar to the CHX(L) and statistically lower than the CHX(G) and OIL groups. NAT did not present a statistical difference of the NaOCl(L), NaOCl(G), and presented a significantly lower NCF than the CHX(G) (p < 0.01). CONCLUSION: The use of CHX(G) resulted in increased cyclic fatigue resistance of the XPS instruments compared to NaOCl or LO.

19.
J Endod ; 47(11): 1751-1766, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34352304

RESUMEN

INTRODUCTION: This study aimed to investigate methodological quality of clinical trials in regenerative endodontics and its compliance with the CONSORT statement. METHODS: An electronic search was performed in 8 electronic databases. Only clinical trials whose participants underwent regenerative endodontic treatment on necrotic permanent immature teeth were included. Quality assessment was performed using the Cochrane Collaboration's Risk of Bias Tool (RoB, version 2.0). Compliance of articles with the CONSORT guidelines was assessed by a tool with scales: 0 = no description, 1 = deficient, and 2 = adequate description, totaling a maximum score of 32 points. The Mann-Whitney and Kruskal-Wallis tests were used to compare the scores among journals, studies, country, income levels, and publication periods. Spearman correlation analyses were performed between CONSORT compliance scores and 2019 journal CiteScore values, publication year, and quality assessment. RESULTS: Twenty studies were included. The average CONSORT compliance score was 20.95 (±6.19). The better reported items were the description of the interventions performed in the trials (100%), followed by the description of the number of patients analyzed, losses and exclusions (90%), and the hypothesis tested (85%). Within the 20 studies, 3 articles were classified as "low risk of bias," 8 studies were classified as "some concerns," and 9 studies were considered "high risk of bias." Studies carried out in countries with higher income levels presented higher CONSORT scores. Significant moderate correlations were found between the CONSORT score and the percentage of risk of bias in low-risk domains (rs = 0.63; 95% CI, 0.31-0.94; P = .003) and the overall risk of bias categories (rs = 0.76; 95% CI, 0.54-0.98; P = .001). CONCLUSIONS: The adequacy of reporting based on the CONSORT checklist items of regenerative endodontic trials was low with a moderate to high risk of bias.


Asunto(s)
Endodoncia Regenerativa , Sesgo , Lista de Verificación , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto
20.
Dent. press endod ; 11(2): 49-55, maio-ago.2021. Tab, Ilus
Artículo en Inglés | LILACS | ID: biblio-1377899

RESUMEN

Objetivo: Avaliar, por meio de tomografia computadorizada de feixe cônico (TCFC), a morfologia dos canais radiculares de dentes incisivos inferiores, em uma população da região Sudeste brasileira, e sua relação com a idade e o sexo dos pacientes Métodos: Foram analisados 371 prontuários de pacientes de ambos os sexos que continham exames de TCFC, totalizando 1.484 dentes incisivos inferiores. As imagens tomográficas foram capturadas com o tomógrafo Orthopantomograph OP300, com voxel de 0,20mm. A morfologia dos dentes foi avaliada de acordo com a classificação de Vertucci, e foram investigados os efeitos do sexo e da idade dos pacientes sobre a variação na morfologia desses dentes. Resultados: Todos os dentes avaliados apresentaram apenas uma raiz; 80,7% dos incisivos inferiores apresentaram um único canal (Tipo I de Vertucci). O segundo canal esteve presente em 19,3% dos casos, sendo do Tipo II de Vertucci em 1,1%, Tipo III em 18,1%, Tipo IV em 0,1% e Tipo V em 0,1%. Não houve influência estatisticamente significativa (p=0,890) do sexo na morfologia dos incisivos inferiores. Dentro da faixa etária analisada, os indivíduos com menos de 18 anos e aqueles com 40 a 49 anos (28,2% e 26,8% respectivamente) apresentaram significância estatística (p=0,001) quanto à presença de segundo canal, compa- rados aos de outras faixas etárias. Conclusões: A morfologia mais prevalente foi a Tipo I de Vertucci, seguida pelo Tipo III, sem diferença entre os sexos, e com maior prevalência de variação morfológica nos indivíduos com menos de 18 anos e com 40 a 49 anos de idade (AU).


Objective: Evaluate the root canal morphology of per- manent mandibular incisors, through the use of cone bean computed tomography (CBCT) in a population of Brazilian southeast region and its relationship with patient age and sex. Methods: A total of 1,484 mandibular incisors of 371 male and female patient`s medical records were analyzed using CBCT. The tomographic images were by the orthopantomograph OP300 tomograph, with voxel of 0.20 mm. The morphology of the teeth was evaluated according to the classification of VERTUCCI, and the effects of sex and age of the patients on the variation in the morphology of these teeth were investigated. Results: All evaluated teeth had only one root. A single canal (Ver- tuccis type I) was detected in 80.7% of mandibular incisors. The second canal was present in 19.3% of the cases, with rates of 1.1% for Type II, 18.1% for Type III, 0.1% for Type IV, and 0.1% for Type V. According to sex, there was no statistical difference (p = 0.890) in mandibular incisor morphology. Within the analyzed age group, individuals aged under 18 years and individuals between 40 and 49 years (28.2% and 26,8% respectively) were statistically significant (p = 0.001) when compared to the other age groups. Conclusions: The most prevalent morphology was Type I of VERTUCCI, followed by Type III, without difference between sex and with a higher prevalence of morphological variation in individuals with less than 18 years and between 40 and 49 years (AU).


Asunto(s)
Humanos , Población , Anatomía , Incisivo , Prevalencia , Métodos , Grupos de Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...