Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Biosensors (Basel) ; 14(6)2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38920587

RESUMEN

A microfluidic immuno-biosensor detection system consisting of a microfluidic spectrum chip and a micro-spectrometer detection device is presented for the rapid point-of-care (POC) detection and quantification of high-sensitivity C-reactive protein (hs-CRP) in urine. The detection process utilizes a highly specific enzyme-linked immunosorbent assay (ELISA) method, in which capture antibodies and detection antibodies are pre-deposited on the substrate of the microchip and used to form an immune complex with the target antigen. Horseradish peroxidase (HRP) is added as a marker enzyme, followed by a colorimetric reaction using 3,3',5,5'-tetramethylbenzidine (TMB). The absorbance values (a.u.) of the colorimetric reaction compounds are measured using a micro-spectrometer device and used to measure the corresponding hs-CRP concentration according to the pre-established calibration curve. It is shown that the hs-CRP concentration can be determined within 50 min. In addition, the system achieves recovery rates of 93.8-106.2% in blind water samples and 94.5-104.6% in artificial urine. The results showed that the CRP detection results of 41 urine samples from patients with chronic kidney disease (CKD) were highly consistent with the conventional homogeneous particle-enhanced turbidimetric immunoassay (PETIA) method's detection results (R2 = 0.9910). The experimental results showed its applicability in the detection of CRP in both urine and serum. Overall, the results indicate that the current microfluidic ELISA detection system provides an accurate and reliable method for monitoring the hs-CRP concentration in point-of-care applications.


Asunto(s)
Técnicas Biosensibles , Proteína C-Reactiva , Ensayo de Inmunoadsorción Enzimática , Sistemas de Atención de Punto , Proteína C-Reactiva/análisis , Humanos , Dispositivos Laboratorio en un Chip , Microfluídica , Colorimetría
2.
Micromachines (Basel) ; 14(6)2023 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-37374718

RESUMEN

A microfluidic distillation system is proposed to facilitate the separation and subsequent determination of propionic acid (PA) in foods. The system comprises two main components: (1) a polymethyl methacrylate (PMMA) micro-distillation chip incorporating a micro-evaporator chamber, a sample reservoir, and a serpentine micro-condensation channel; and (2) and a DC-powered distillation module with built-in heating and cooling functions. In the distillation process, homogenized PA sample and de-ionized water are injected into the sample reservoir and micro-evaporator chamber, respectively, and the chip is then mounted on a side of the distillation module. The de-ionized water is heated by the distillation module, and the steam flows from the evaporation chamber to the sample reservoir, where it prompts the formation of PA vapor. The vapor flows through the serpentine microchannel and is condensed under the cooling effects of the distillation module to produce a PA extract solution. A small quantity of the extract is transferred to a macroscale HPLC and photodiode array (PDA) detector system, where the PA concentration is determined using a chromatographic method. The experimental results show that the microfluidic distillation system achieves a distillation (separation) efficiency of around 97% after 15 min. Moreover, in tests performed using 10 commercial baked food samples, the system achieves a limit of detection of 50 mg/L and a limit of quantitation of 96 mg/L, respectively. The practical feasibility of the proposed system is thus confirmed.

3.
Food Chem ; 407: 135118, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-36493490

RESUMEN

A novel assay platform consisting of a finger pump microchip (FPM) and a WiFi-based analytical detection platform is presented for measuring the concentration of methylparaben (MP) in commercial foods. In the presented approach, a low quantity (5 µL) of distilled food sample is dripped onto the FPM and undergoes a modified Fenton reaction at a temperature of 40 °C to form a green-colored complex. The MP concentration is then determined by measuring the color intensity (RGB) of the reaction complex using APP software (self-written) installed on a smartphone. The color intensity Red(R) + Green(G) value of the reaction complex is found to be linearly related (R2 = 0.9944) to the MP concentration for standard samples with different MP concentrations ranging from 100 to 3000 ppm. The proposed method is used to detect the MP concentrations of 12 real-world commercial foods. The MP concentrations measurements are found to deviate by no more than 5.88% from the results obtained using a conventional benchtop method. The presented platform thus offers a feasible and low-cost alternative to existing macroscale techniques for measuring the MP concentration in commercial foods.


Asunto(s)
Colorimetría , Microfluídica , Colorimetría/métodos , Teléfono Inteligente
4.
Food Chem ; 400: 134063, 2023 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-36084592

RESUMEN

Cyclamate is an artificial sweetener with high sweetness and low calories, and is a common sugar substitute for weight control and diabetic patients. However, excessive cyclamate consumption is associated with various health disorders, and hence it is prohibited as a food additive in many countries around the world. The current research proposes a light-shading reaction microfluidic PMMA/paper detection (MPD) system for determining the cyclamate concentration in food. In the current system, inject 10 µL of the extracted sodium cyclamate sample into the sample chamber of the MPD device, perform the diazotization reaction under shading conditions, and then suck it into the detection area through a paper strip, which consists of a paper chip embedded with modified Bratton-Marshall reagent. Once the paper chip is thoroughly wetted, the MPD device is inserted into a microanalysis box, where a fuchsia azo reaction compound is produced through heating at 40 °C for 3 min. The reaction complex is observed by a camera and the reaction image is wirelessly transmitted to a smartphone, and the concentration of sodium cyclamate is measured through the self-developed grayscale software. The results obtained for the sodium cyclamate samples with a concentration in the range of 50-1000 ppm show that the measured gray value changes linearly with the sodium cyclamate concentration, and the correlation coefficient (R2) is 0.9898. By analyzing the concentration of sodium cyclamate in 10 real-world samples, the practical feasibility of the current MPD system is proved. The results showed that the concentration measurement value did not deviate by more than 4.8 % from the value obtained using the conventional liquid chromatography/tandem mass spectrometry (LC-MS/MS) method.


Asunto(s)
Ciclamatos , Polimetil Metacrilato , Cromatografía Liquida , Ciclamatos/análisis , Aditivos Alimentarios/análisis , Humanos , Microfluídica , Edulcorantes/análisis , Espectrometría de Masas en Tándem
5.
Biosensors (Basel) ; 12(7)2022 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-35884299

RESUMEN

A novel assay platform consisting of a microfluidic sliding double-track paper-based chip and a hand-held Raspberry Pi detection system is proposed for determining the albumin-to-creatine ratio (ACR) in human urine. It is a clinically important parameter and can be used for the early detection of related diseases, such as renal insufficiency. In the proposed method, the sliding layer of the microchip is applied and the sample diffuses through two parallel filtration channels to the reaction/detection areas of the microchip to complete the detection reaction, which is a simple method well suited for self-diagnosis of ACR index in human urine. The RGB (red, green, and blue) value intensity signals of the reaction complexes in these two reaction zones are analyzed by a Raspberry Pi computer to derive the ACR value (ALB and CRE concentrations). It is shown that the G + B value intensity signal is linearly related to the ALB and CRE concentrations with the correlation coefficients of R2 = 0.9919 and R2 = 0.9923, respectively. It is additionally shown that the ALB and CRE concentration results determined using the proposed method for 23 urine samples were collected from real suffering chronic kidney disease (CKD) patients are in fine agreement with those acquired operating a traditional high-reliability macroscale method. Overall, for point-of-care (POC) CKD diagnosis and monitoring in clinical applications, the results prove that the proposed method offers a convenient, real time, reliable, and low-spending solution for POC CKD diagnosis.


Asunto(s)
Creatina , Insuficiencia Renal Crónica , Albúminas/análisis , Creatinina/orina , Humanos , Microfluídica , Sistemas de Atención de Punto , Insuficiencia Renal Crónica/diagnóstico , Reproducibilidad de los Resultados
6.
Anal Chim Acta ; 1203: 339722, 2022 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-35361435

RESUMEN

An integrated microfluidic Au nanoparticle (AuNP) aptasensor device is proposed for monitoring the concentration of potassium (K+) ions in the bloodstream of patients with chronic kidney disease (CKD). In the proposed detection device, the AuNPs in the AuNP/aptamer complex are displaced by the serum K+ ions and react with NaCl to produce a color change in the detection region from which the K+ ion concentration is then inversely derived. The microfluidic device comprises two main components, namely an AuNP aptasensor PMMA (Poly(methyl methacrylate))/paper-microchip and a colorimetric analysis system for the quantitative detection of K+ ion concentration in whole blood. The functions of PMMA/paper microchips include reagent storage, K+ ion/aptamer reaction, and separation of serum from whole blood samples (blood filter). Experimental results show that the microfluidic device provides a linear response over the K+ ion concentration in range of 0.05-9 mM in artificial serum and has a detection limit (LOD) of 0.01 mM. Moreover, the detection results obtained for the 137 whole blood and 287 serum samples of CKD patients are very consistent (R2 = 0.968 and R2 = 0.980) with the measurement results obtained using an ion-selective electrodes (ISE) method. Results confirm that the current microfluidic aptasensor device provides a highly-sensitive and convenient method for performing the point-of-care (POC) monitoring of the whole blood K+ ion concentration.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Nanopartículas del Metal , Técnicas Biosensibles/métodos , Oro , Humanos , Iones , Dispositivos Laboratorio en un Chip , Microfluídica , Sistemas de Atención de Punto , Potasio/análisis
7.
Biosensors (Basel) ; 11(12)2021 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-34940248

RESUMEN

For most of the fast screening test papers for detecting Hg2+, the obtained results are qualitative. This study developed an operation for the µPAD and combined it with the chemical colorimetric method. Silver nanoparticle (AgNP) colloids were adopted as the reactive color reagent to combine and react with the Hg standards on the paper-based chip. Then, the RGB values for the color change were used to establish the standard curve (R2 > 0.99). Subsequently, this detection system was employed for the detection tests of actual samples, and the detected RGB values of the samples were substituted back to the formula to calculate the Hg2+ contents in the food. In this study, the Hg2+ content and recovery rate in commercially available packaged water and edible salts were measured. The research results indicate that a swift, economical, and simple detection method for Hg2+ content in food has been successfully developed.


Asunto(s)
Mercurio , Nanopartículas del Metal , Colorimetría , Microfluídica , Plata/análisis , Plata/química
8.
Toxics ; 9(10)2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34678942

RESUMEN

Due to the sparsity in knowledge, we investigated the presence of various estrogenic endocrine-disrupting chemicals (EEDCs), including phthalates (PAEs), bisphenol-A (BPA), and nonylphenol (NP), as well as microplastics (MPs) in samples of the most widely consumed fish collected from different estuaries in northern Taiwan. We then proceeded to determine the likely contribution that this exposure has on the potential for health impacts in humans following consumption of the fish. Six hundred fish caught from five river estuaries (producing 130 pooled samples) were analyzed to determine how different factors (such as the river, benthic, pelagic, and migratory species) influence EEDCs' contamination and the possible impacts on human health following typical consumption patterns. The predominant EEDCs was diethyl phthalates (DEP), bis (2-ethylhexyl) phthalates (DEHP), and di-iso-nonylphthalate (DINP) in fish, present at 52.9 ± 77.3, 45.3 ± 79.8, and 42.5 ± 79.3 ng/g dry weight (d.w.), respectively. Residual levels of NP, BPA, and MPs in the fish were 17.4 ± 29.1 and 1.50 ± 2.20 ng/g d.w. and 0.185 ± 0.338 mg/g d.w., respectively. EEDCs and MPs levels varied widely among the five river estuaries sampled due, in part, to differences in habitat types and the associated diversity of fish species sampled. For DEP, the Lao-Jie River and pelagic environments produced the most severely contaminated fish species, respectively. DEP residues were also associated with the burden of MPs in the fish. Based on our analysis, we predict no substantial direct human health risk by EEDCs based on typical consumption rates of estuarine fish by the Taiwanese people. However, other sources of EEDC exposure cannot be ignored.

9.
Micromachines (Basel) ; 12(9)2021 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-34577766

RESUMEN

Silver nanoparticles (AgNPs) have stable reactivity and excellent optical absorption properties. They can be applied in various industries, such as environmental protection, biochemical engineering, and analyte monitoring. However, synthesizing AgNPs and determining their appropriate dosage as a coloring substance are difficult tasks. In this study, to optimize the process of AgNP synthesis and obtain a simple detection method for trace mercury in the environment, we evaluate several factors-including the reagent addition sequence, reaction temperature, reaction time, the pH of the solution, and reagent concentration-considering the color intensity and purity of AgNPs as the reaction optimization criteria. The optimal process for AgNP synthesis is as follows: Mix 10 mM of silver nitrate with trisodium citrate in a hot water bath for 10 min; then, add 10 mM of sodium borohydride to produce the AgNPs and keep stirring for 2 h; finally, adjust the pH to 12 to obtain the most stable products. For AgNP-based mercury detection, the calibration curve of mercury over the concentration range of 0.1-2 ppb exhibits good linearity (R2 > 0.99). This study provides a stable and excellent AgNP synthesis technique that can improve various applications involving AgNP-mediated reactions and has the potential to be developed as an alternative to using expensive detection equipment and to be applied for the detection of mercury in food.

10.
Biosensors (Basel) ; 11(8)2021 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-34436062

RESUMEN

In recent years, microfluidic lab-on-paper devices have emerged as a rapid and low-cost alternative to traditional laboratory tests. Additionally, they were widely considered as a promising solution for point-of-care testing (POCT) at home or regions that lack medical infrastructure and resources. This review describes important advances in microfluidic lab-on-paper diagnostics for human health monitoring and disease diagnosis over the past five years. The review commenced by explaining the choice of paper, fabrication methods, and detection techniques to realize microfluidic lab-on-paper devices. Then, the sample pretreatment procedure used to improve the detection performance of lab-on-paper devices was introduced. Furthermore, an in-depth review of lab-on-paper devices for disease measurement based on an analysis of urine samples was presented. The review concludes with the potential challenges that the future development of commercial microfluidic lab-on-paper platforms for human disease detection would face.


Asunto(s)
Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas , Humanos , Microfluídica , Papel , Pruebas en el Punto de Atención
12.
Micromachines (Basel) ; 12(5)2021 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-34068982

RESUMEN

Milk is a necessity for human life. However, it is susceptible to contamination and adulteration. Microfluidic analysis devices have attracted significant attention for the high-throughput quality inspection and contaminant analysis of milk samples in recent years. This review describes the major proposals presented in the literature for the pretreatment, contaminant detection, and quality inspection of milk samples using microfluidic lab-on-a-chip and lab-on-paper platforms in the past five years. The review focuses on the sample separation, sample extraction, and sample preconcentration/amplification steps of the pretreatment process and the determination of aflatoxins, antibiotics, drugs, melamine, and foodborne pathogens in the detection process. Recent proposals for the general quality inspection of milk samples, including the viscosity and presence of adulteration, are also discussed. The review concludes with a brief perspective on the challenges facing the future development of microfluidic devices for the analysis of milk samples in the coming years.

13.
Talanta ; 231: 122362, 2021 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-33965028

RESUMEN

A microfluidic colorimetric detection (MCD) platform consisting of a sliding hybrid PMMA/paper microchip and a smart analysis system is proposed for the convenient, low-cost and rapid analysis of human urine and whole blood samples. The sliding PMMA/paper microchip comprises a PMMA microfluidic chip for sample injection and transportation, a paper strip for sample filtration (urine) or separation (blood), and a sealed paper-chip detection zone for sample reaction and detection. In the proposed device, the paper-chip is coated with bicinchoninic acid (BCA) and biuret reagent and is then assembled into the PMMA microchip and packaged in aluminum housing. In the detection process, the PMMA/paper microchip is slid partially out of the housing, and 2 µL of sample (urine or whole blood) is dripped onto the sample injection zone. The chip is then slid back into the housing and the sample is filtered/separated by the paper strip and transferred under the effects of capillary action to the sealed paper-chip detection zone. The housing is inserted into the color analysis system and heated at 45 °C for 5 min to produce a purple-colored reaction complex. The complex is imaged using a CCD camera and the RGB color intensity of the image is then analyzed using a smartphone to determine the total protein (TP) concentration of the sample. The effectiveness of the proposed method is demonstrated using TP control samples with known concentrations in the range of 0.03-5.0 g/dL. The detection results obtained for 50 human urine samples obtained from random volunteers are shown to be consistent with those obtained from a conventional hospital analysis system (R2 = 0.992). Moreover, the detection results obtained for the albumin (ALB) and creatine (CRE) concentrations of 50 whole blood samples are also shown to be in good agreement with the results obtained from the hospital analysis system (R2 = 0.982 and 0.988, respectively).


Asunto(s)
Colorimetría , Polimetil Metacrilato , Pruebas Hematológicas , Humanos , Microfluídica , Teléfono Inteligente
14.
Lab Chip ; 21(8): 1433-1453, 2021 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-33881033

RESUMEN

Lab-on-paper, or microfluidic paper-based analytical devices (µPADs), use paper as a substrate material, and are patterned with a system of microchannels, reaction zones and sensing elements to perform analysis and detection. The sample transfer in such devices is performed by capillary action. As a result, external driving forces are not required, and hence the size and cost of the device are significantly reduced. Lab-on-paper devices have thus attracted significant attention for point-of-care medical diagnostic purposes in recent years, particularly in less-developed regions of the world lacking medical resources and infrastructures. This review discusses the major advances in lab-on-paper technology for blood analysis and diagnosis in the past five years. The review focuses particularly on the many clinical applications of lab-on-paper devices, including diabetes diagnosis, acute myocardial infarction (AMI) detection, kidney function diagnosis, liver function diagnosis, cholesterol and triglyceride (TG) analysis, sickle-cell disease (SCD) and phenylketonuria (PKU) analysis, virus analysis, C-reactive protein (CRP) analysis, blood ion analysis, cancer factor analysis, and drug analysis. The review commences by introducing the basic transmission principles, fabrication methods, structural characteristics, detection techniques, and sample pretreatment process of modern lab-on-paper devices. A comprehensive review of the most recent applications of lab-on-paper devices to the diagnosis of common human diseases using blood samples is then presented. The review concludes with a brief summary of the main challenges and opportunities facing the lab-on-paper technology field in the coming years.


Asunto(s)
Técnicas Analíticas Microfluídicas , Papel , Acción Capilar , Humanos , Dispositivos Laboratorio en un Chip , Sistemas de Atención de Punto
15.
Micromachines (Basel) ; 12(3)2021 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-33809131

RESUMEN

A magnetic field measurement system based on an array of Hall sensors is proposed. The sensors are fabricated using conventional microelectromechanical systems (MEMS) techniques and consist of a P-type silicon substrate, a silicon dioxide isolation layer, a phosphide-doped cross-shaped detection zone, and gold signal leads. When placed within a magnetic field, the interaction between the local magnetic field produced by the working current and the external magnetic field generates a measurable Hall voltage from which the strength of the external magnetic field is then derived. Four Hall sensors are fabricated incorporating cross-shaped detection zones with an identical aspect ratio (2.625) but different sizes (S, M, L, and XL). For a given working current, the sensitivities and response times of the four devices are found to be almost the same. However, the offset voltage increases with the increasing size of the detection zone. A 3 × 3 array of sensors is assembled into a 3D-printed frame and used to determine the magnetic field distributions of a single magnet and a group of three magnets, respectively. The results show that the constructed 2D magnetic field contour maps accurately reproduce both the locations of the individual magnets and the distributions of the magnetic fields around them.

16.
Anal Chim Acta ; 1146: 70-76, 2021 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-33461721

RESUMEN

An electrochemical-biosensor (EC-biosensor) microchip consisting of screen-printed electrodes and a double-layer reagent paper detection zone impregnated with amaranth is proposed for the rapid determination of microalbuminuria (MAU) in human urine samples. Under the action of an applied deposition potential, the amaranth is adsorbed on the electrode surface and the subsequent reaction between the modified surface and the MAU content in the urine sample prompts the formation of an inert layer on the electrode surface. The inert layer impedes the transfer of electrons and hence produces a drop in the response peak current, from which the MAU concentration can then be determined. The measurement results obtained for seven artificial urine samples with known MAU concentrations in the range of 0.1-40 mg/dL show that the measured response peak current is related to the MAU concentration with a determination coefficient of R2 = 0.991 in the low concentration range of 0.1-10 mg/dL and R2 = 0.996 in the high concentration range of 10-40 mg/dL. Furthermore, the detection results obtained for 82 actual chronic kidney disease (CKD) patients show an excellent agreement (R2 = 0.988) with the hospital analysis results. Overall, the results confirm that the proposed detection platform provides a convenient and reliable approach for performing sensitive point-of-care testing (POCT) of the MAU content in human urine samples.


Asunto(s)
Técnicas Biosensibles , Insuficiencia Renal Crónica , Albuminuria/diagnóstico , Técnicas Electroquímicas , Electrodos , Humanos , Insuficiencia Renal Crónica/diagnóstico
17.
J Clin Med ; 11(1)2021 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-35011897

RESUMEN

Cadmium exposure is associated with chronic kidney disease (CKD), but the optimal biomarker for early cadmium-associated nephrotoxicity in low-level exposure has not yet been established. We conducted a cross-sectional investigation involving 167 CKD patients stratified according to tertiles of urinary cadmium levels (UCd), in which enzyme-linked immunosorbent assay (ELISA)-measured novel renal biomarkers were utilized to assess the extent of renal injury associated with cadmium burden. In the analyses, urinary kidney injury molecule-1 (KIM-1) levels and age were the independent factors positively correlated with UCd after adjusting for covariates in non-dialysis-dependent CKD patients (high vs. low UCd, odds ratio (95% confidence interval), 1.0016 (1.0001-1.0032), p = 0.043, and 1.0534 (1.0091-1.0997), p = 0.018). Other conventional and novel renal biomarkers, such as serum creatinine, estimated glomerular filtration rate, CKD staging, urinary protein/creatinine ratio, urinary 8-hydroxy-2-deoxyguanosine (8-OHdG), and urinary epidermal growth factor (EGF) were not independently correlated with UCd in the analyses. In conclusion, our study found that the ELISA-measured urinary KIM-1 level could serve as an early renal injury marker in low-level cadmium exposure for non-dialysis-dependent CKD patients. In addition, age was an independent factor positively associated with UCd in this population.

18.
Food Chem ; 345: 128773, 2021 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-33302108

RESUMEN

Sodium benzoate (SBA) is a widely-used additive for preventing food spoilage and deterioration and extending the shelf life. However, the concentration of SBA must be controlled under safe regulations to avoid damaging human health. Accordingly, this study proposes a microfluidic colorimetric analysis (MCA) system composing of a wax-printed paper-microchip and a self-made smart analysis equipment for the concentration detection of SBA in common foods and beverages. In the presented method, the distilled SBA sample is mixed with NaOH to obtain a nitro compound and the compound is then dripped onto the reaction area of the paper-microchip, which is embedded with two layers of reagents (namely acetophenone and acetone). The paper-microchip is heated at 120 °C for 20 min to cause a colorimetric reaction and the reaction image is then obtained through a CMOS (complementary metal oxide semiconductor) device and transmitted to a cell-phone over a WiFi connection. Finally, use the self-developed RGB analysis software installed on the cell-phone to obtain the SBA concentration. A calibration curve is constructed using SBA samples with known concentrations ranging from 50 ppm (0.35 mM) to 5000 ppm (35 mM). It is shown that the R + G + B value (Y) of the reaction image and SBA concentration (X) are related via Y = -0.034 X +737.40, with a determination coefficient of R2 = 0.9970. By measuring the SBA concentration of 15 commercially available food and beverage products, the actual feasibility of the current MCA system can be demonstrated. The results show that the difference from the measurement results obtained using the macroscale HPLC method does not exceed 6.0%. Overall, the current system provides a reliable and low-cost technique for quantifying the SBA concentration in food and drink products.


Asunto(s)
Colorimetría/métodos , Aditivos Alimentarios/análisis , Análisis de los Alimentos/métodos , Técnicas Analíticas Microfluídicas/métodos , Benzoato de Sodio/análisis , Bebidas/análisis , Cromatografía Líquida de Alta Presión , Humanos , Estándares de Referencia
19.
Anal Chim Acta ; 1071: 44-52, 2019 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-31128754

RESUMEN

A multifunctional microchip-based distillation apparatus is presented for the distilled of sulfur dioxide (SO2) in food products. The microchip is fabricated on poly(methyl methacrylate) (PMMA) substrates, and comprises a sample zone, a buffer zone, a serpentine distillation column, and a collection zone. In the process, the sample is introduced into the sample zone and is heated under carefully controlled temperature and time conditions. The resulting SO2 and water vapor are carried by nitrogen (N2) gas to the distillation column, where the SO2 is separated from the water vapor via the condensing effects of a continuous cold water flow. Finally, the SO2 is transported to the collection zone, where it is collected with hydrogen peroxide (H2O2) and its concentration determined using an alkali-based titration and paper-based detection method. A distillation efficiency of 90.5% is obtained under the optimal distillation conditions at concentrations of 20-4000 ppm. Moreover, a linear correlation (R2 = 0.9997) is observed between the experimental measurements of the SO2 concentration and the known concentration. The validity of the presented microchip-based distillation apparatus is further investigated by distilling the SO2 concentrations of 25 commodity samples. The detection results show that the deviation does not exceed 5.4% compared with the traditional official method.


Asunto(s)
Destilación/métodos , Técnicas Analíticas Microfluídicas/métodos , Dióxido de Azufre/análisis , Destilación/instrumentación , Contaminación de Alimentos/análisis , Frutas/química , Dispositivos Laboratorio en un Chip , Límite de Detección , Técnicas Analíticas Microfluídicas/instrumentación , Polimetil Metacrilato/química , Verduras/química
20.
Anal Chim Acta ; 1062: 94-101, 2019 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-30948000

RESUMEN

A multifunctional microchip-based distillation apparatus for distilling and detecting formaldehyde (CH2O) in food products is developed. The presented apparatus comprises a disposable microchip, a steam supply system, and a recirculating cooling water supply. The microchip is formed on PMMA substrates by laser ablation and includes a sample zone, a flash distillation zone, a cooling zone, a condensation zone, and a collection zone. In the presented method, the CH2O sample is placed in the microchip and is vaporized by the high-throughput vapor supply and driven through the condensed zone. The condensed CH2O liquid is guided into the collection zone of the microchip. Finally, the distilled CH2O solution is determined using an AHMT spectrometry method and a paper-based RGB (red, green and blue) intensity analysis method. A distilled efficiency is as high as 98%, when a vapor stream rate is 0.4 ml/min and a distilled time is 10 min. Moreover, both detection methods show linear relationships of the corresponding CH2O concentrations. The actual sample suitability of the presented multifunctional microchip-based distillation apparatus is confirmed by analyzing the CH2O concentrations of 21 commodities.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA