1.
Clin Cardiol ; 47(7): e24308, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39011838

RESUMEN

BACKGROUND: Right ventricular-pulmonary artery coupling (RVPAC) refers to the relationship between right ventricular systolic force and afterload. The ratio of echocardiograph-derived tricuspid annular plane systolic excursion (TAPSE) to pulmonary artery systolic pressure (PASP) has been proposed as a noninvasive measurement of RVPAC and reported as an independent prognostic parameter of heart failure. However, it has not been adequately in detail evaluated in heart failure with preserved ejection fraction (HFpEF). We hypothesized that RVPAC may be used and proposed as an expression of key risk factors in patients with HFpEF. METHODS: We retrospectively analyzed TAPSE/PASP of 648 HFpEF patients hospitalized in Chongqing Hospital of Traditional Chinese Medicine from January 1, 2016 to January 1, 2017. All eligible patients were followed up for 5 years. The correlation between TAPSE/SPAP index and clinical indicators and outcomes was evaluated. RESULTS: The final analysis included 414 patients. Nonsurvivors had significantly lower TAPSE, TAPSE/PASP and higher PASP compared with survivors (p < 0.0001). ROC curve analysis showed that the optimal cutoff of TAPSE, PASP, and RVPAC to predict all-cause death were 16.5 mm, 37.5 mmHg, and 0.45 mm/mmHg, respectively. In multivariate Cox regression analyses adjusted for gender showed a significant, independent association of the RVPAC with the composite endpoint of all-cause death or HF-related recurrent hospitalization (HR: 0.006; 95% CI 0.001-0.057, p < 0.001). CONCLUSIONS: RVPAC, defined by the ratio of TAPSE to PASP, is the expression of a key risk factor in HFpEF patients, which is independently associated with the composite endpoint of all-cause death or HF-related recurrent hospitalization.


Asunto(s)
Insuficiencia Cardíaca , Arteria Pulmonar , Volumen Sistólico , Función Ventricular Derecha , Humanos , Masculino , Femenino , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/diagnóstico , Volumen Sistólico/fisiología , Arteria Pulmonar/fisiopatología , Arteria Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , Anciano , Función Ventricular Derecha/fisiología , Pronóstico , Factores de Riesgo , Persona de Mediana Edad , Ecocardiografía , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , China/epidemiología , Estudios de Seguimiento
3.
J Arrhythm ; 40(3): 614-617, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38939779

RESUMEN

Hemidiaphragm paralysis, a complication of catheter ablation for atrial fibrillation, can severely affect respiratory function and can lead to paradoxical breathing and dyspnea on exertion. A 75-year-old woman with iatrogenic diaphragm paralysis showed improved symptoms, respiratory function, and exercise tolerance after video-assisted thoracoscopic diaphragm plication.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38942383

RESUMEN

This paper presents a novel approach to gap mapping in pulmonary vein isolation (PVI) for atrial fibrillation (AF) treatment, utilizing the real-time Ripple (RR) technique. Radiofrequency (RF) catheter ablation, particularly encircling PVI, is a common intervention for AF. Identifying left atrium-pulmonary vein conduction gaps is crucial for achieving PVI with minimal additional ablation if first-pass PVI is unsuccessful. However, identifying conduction gaps can be relatively challenging, often necessitating manual electrocardiogram reannotation due to the limitations of local activation time (LAT) maps. In the case of a 63-year-old patient with drug-resistant symptomatic persistent AF, the RR technique was utilized to identify conduction gaps during RF ablation. The technique involved pausing fast anatomical mapping (FAM), activating Ripple map (RM) feature on the CARTO 3 system and acquiring points with an ultrahigh-resolution mapping catheter. This approach revealed that the actual site of earliest activation differs from the LAT map indication, enabling successful PVI. The RM feature's capability to reflect actual excitation propagation without reliance on map annotations was crucial for precise conduction gap identification, overcoming inter-operator variability and inaccuracies of conventional methods. The RR technique not only facilitated real-time analysis during gap mapping but also significantly reduced the procedure time, minimizing potential complications. This case report highlights the efficacy of the RR technique in real-time gap mapping, demonstrating its value in cases where first-pass PVI is unsuccessful. The integration of this technique into PVI procedures can enhance both the accuracy and efficiency of catheter ablation for AF.

5.
Clin Case Rep ; 12(6): e9039, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38840753

RESUMEN

The newly-proposed tandem approach, Wire ThRoUgh Snare Twice (Wire TRUST) is effective for grasping a lead with inaccessible ends. This case report shows that Wire TRUST can also enable successful extraction of a left ventricular lead by iteratively grasping and repositioning to the distal portion of the lead.

12.
CVIR Endovasc ; 7(1): 29, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38489103

RESUMEN

BACKGROUND: Severe calcification often prevents device passage and balloon expansion in cases of lower extremity artery disease. To address this limitation, we introduced a novel calcium modification technique called Rendezvous-PIERCE (R-PIERCE). METHODS: A needle was inserted in a retrograde manner and advanced to touch the tip of an antegrade guidewire within the lesion. Then, the guidewire was advanced into the lumen of the needle to achieve partial guidewire externalization, also known as needle rendezvous. The needle was then introduced over the externalized guidewire under wire tension and repeatedly rotated and advanced across the lesion to modify calcified intimal plaques. Notably, this technique can be applied in the opposite direction. RESULTS: Case 1 involved a 68-year-old male with a calcified occlusion of the anterior tibial artery. An antegrade guidewire reached the midpoint of the occlusion; however, microcatheters and balloons could not pass through the proximal calcification. Therefore, R-PIERCE was used to modify uncrossable lesions. An antegrade 2.5-mm balloon crossed and dilated the lesion, achieving hemostasis at the needle insertion site. The antegrade guidewire successfully crossed the entire lesion and was dilated by the 2.5-mm balloon. Final angiography demonstrated successful flow. In Case 2, an 80-year-old male had a calcified femoropopliteal occlusion. An antegrade guidewire was advanced into the distal superficial femoral artery (SFA); however, no device could follow it. R-PIERCE was performed to modify the calcification from the distal to the medial SFA. The antegrade balloon successfully crossed and dilated obstructed lesions. Furthermore, the antegrade guidewire crossed the entire lesion, and the antegrade balloon was dilated. Final angiography revealed a successful flow without complications. CONCLUSIONS: R-PIERCE is useful for modifying complex calcified lesions during the wiring of occlusive lesions.

13.
J Cardiol Cases ; 29(2): 63-66, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38362578

RESUMEN

The VIZIGO sheath (Biosense Webster, Irvine, CA, USA) is used for catheter ablation (CA) of atrial arrhythmia. In this case report, we describe a complication associated with the VIZIGO sheath and present a successful bailout method. An 82-year-old woman with paroxysmal atrial fibrillation (AF) and atrial tachycardia (AT) was referred to our hospital after experiencing palpitations for 6 months. She underwent CA using the VIZIGO sheath and a fixed Swartz sheath (St. Jude Inc., St. Paul, MN, USA). Pulmonary vein isolation and left atrial posterior wall isolation were performed to address AF and AT. Following ablation, the Swartz sheath was removed; however, the VIZIGO sheath showed resistance to removal. A wire was inserted into the VIZIGO sheath for removal, but the distal electrode ring detached in the vessel. To retrieve the electrode ring, a Mustang over-the-wire angioplasty balloon was dilated inside the ring and withdrawn with the ring. After venography and confirmation of a hemostatic seal, the ablation procedure was completed. The patient experienced postoperative anemia, which was resolved by erythrocyte transfusion. No further paroxysmal AF or AT occurred during the 1-year follow-up. In conclusion, the VIZIGO sheath's distal electrode ring may become detached during CA, and the detached ring can be successfully retrieved using our original bailout technique. Learning objective: This case report highlights the unique complication of electrode ring detachment associated with the novel visualized steerable sheath (VIZIGO; Biosense Webster, Irvine, CA, USA) during catheter ablation procedures and presents the successful technique as a bailout method for retrieving the dislodged ring. The technique involves dilating a non-compliant over-the-wire angioplasty balloon inside the ring and withdrawing it along with the detached ring.

14.
CVIR Endovasc ; 7(1): 24, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38421471

RESUMEN

BACKGROUND: The clinical implications of restenosis after drug-coated balloon (DCB) treatment remain unclear. We compared the clinical outcomes between DCB angioplasty for restenosis and de novo femoropopliteal artery lesions. This single-center retrospective study included 571 patients (737 limbs) who underwent either repeat (54 patients, 64 limbs) or de novo DCB (517 patients, 673 limbs) without bailout stenting. After propensity score matching, 49 matched pairs were analyzed. The primary endpoint was the 1-year primary patency, with secondary endpoints including the freedom from target lesion revascularization (TLR), major adverse limb events (MALE), and early restenosis. Predictors of restenosis were identified using multivariable Cox regression analysis. RESULTS: The repeat-DCB group displayed significantly lower rates of 1-year primary patency and freedom from TLR compared to those of the de novo-DCB group (50.1% vs. 77.4%, p = 0.029 and 54.9% vs. 83.6%, p = 0.0.44, respectively). No significant differences were observed in early restenosis or MALE (10.7% vs. 5.9%, p = 0.455 and 48.3% vs. 73.4%, p = 0.055, respectively). Restenosis after DCB angioplasty was associated with repeat DCB (hazard ratio [HR], 5.13; 95% confidence interval [CI], 1.43-18.4; p = 0.012) and small vessel size of < 4.5 mm (HR, 6.25; 95% CI, 1.17-33.4; p = 0.032). Furthermore, restenosis after repeat DCB angioplasty was associated with the Peripheral Artery Calcification Scoring System (PACSS) grade 4 (HR, 4.20; 95% CI, 1.08-16.3; p = 0.038), small vessel size of < 4.5 mm (HR, 9.44; 95% CI, 1.21-73.7; p = 0.032), and intravascular ultrasound (IVUS) use (HR, 0.05; 95% CI, 0.01-0.44; p = 0.007). CONCLUSIONS: The 1-year primary patency rate following repeat DCB angioplasty for femoropopliteal lesions was notably lower than that of DCB treatment for de novo lesions. Repeat DCB strategy was associated with an increased risk of patency loss. Regarding repeat restenosis after DCB treatments, PACSS grade 4 calcification and small vessel diameter of < 4.5 mm were associated with an increased risk of restenosis, whereas IVUS use correlated with a decreased risk of restenosis.

15.
Catheter Cardiovasc Interv ; 103(1): 97-105, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37975201

RESUMEN

BACKGROUND: Whether drug-coated balloon (DCB) angioplasty would be effective in spiral dissection (SD) lesions with no flow impairment has been thoroughly investigated. AIMS: The present study sought to assess the clinical outcomes of non-flow-limiting SD after DCB angioplasty for de novo femoropopliteal lesions in patients with symptomatic lower extremity artery disease. METHOD: This single-center retrospective study enrolled 497 patients with non-flow-limiting SD (n = 92) or non-SD (n = 405) without bailout stenting. The primary endpoint was 1-year primary patency, with the secondary endpoints including freedom from target lesion revascularization (TLR), major adverse limb event (MALE), all-cause death, and 30-day restenosis. RESULTS: The 1-year primary patency and freedom from TLR were significantly lower in the SD group than in the non-SD group (69.8% vs. 83.3%, p = 0.004; 78.7% vs. 93.0%, p = 0.007, respectively). The SD group had a higher incidence of MALE and 30-day restenosis than the non-SD group (24.6% vs. 11.9%, p = 0.001; 4.3% vs. 0.5%, p = 0.002, respectively). All-cause death was comparable. One-year restenosis after SD was associated with chronic limb-threatening ischemia (CLTI) (hazard ratio, 3.36 [95% confidence interval, 1.21-9.36]; p = 0.020), TASC Ⅱ D (hazard ratio, 3.97 [95% confidence interval, 1.02-15.52]; p = 0.047), and residual stenosis ≥50% (hazard ratio, 4.92 [95% confidence interval, 1.01-23.94]; p = 0.048). The incidence of restenosis after SD increased with the number of these risk factors. CONCLUSIONS: Despite normal antegrade flow, the 1-year primary patency rate after DCB angioplasty for de novo femoropopliteal lesions was significantly lower in lesions with SD than those without SD. CLTI, TASC II D, and residual stenosis ≥50% were risk factors associated with 1-year restenosis after DCB angioplasty for non-flow-limiting SD lesions.


Asunto(s)
Angioplastia de Balón , Enfermedad Arterial Periférica , Humanos , Arteria Femoral/diagnóstico por imagen , Arteria Poplítea/diagnóstico por imagen , Constricción Patológica , Estudios Retrospectivos , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Resultado del Tratamiento , Angioplastia de Balón/efectos adversos , Materiales Biocompatibles Revestidos , Grado de Desobstrucción Vascular
18.
J Invasive Cardiol ; 35(10)2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37984323

RESUMEN

OBJECTIVES: Burr entrapment is a potentially life-threatening complication of rotational atherectomy (RA). However, owing to its infrequency, there have been no major reports on burr entrapment. This study aimed to evaluate the incidence, treatment, and outcomes of burr entrapment. METHODS: This multicenter retrospective study analyzed patients who had undergone percutaneous coronary interventions (PCIs) and were treated by RA between May 2013 and March 2022. RESULTS: Of the 22 640 PCI procedures, RA was performed in 3195 patients (14.1%), among whom burr entrapment occurred in 22 patients (0.69%). The mean patient age was 78 ± 8.7 years; 64% were male, and 32% were on dialysis. The entrapped burr size was 1.7 ± 0.2 mm, and the burr/artery ratio was 0.6 ± 0.1. In 20 patients (91%), the burr was extracted by strong manual pullback. The other patients underwent balloon angioplasty at the site of the entrapped burr, which might have provided space for successful burr withdrawal. Major adverse cardiac events occurred in 23% of patients. Tamponade requiring pericardiocentesis occurred in two patients (9%). No patients required emergency surgery or suffered an in-hospital death. CONCLUSIONS: Burr entrapment occurred in 0.69% of patients who had undergone RA. Most burrs were extracted by a strong manual pullback. None required emergency surgery, and there were no in-hospital deaths. The results provide a treatment approach and prognosis for burr stuck in the use of RA.


Asunto(s)
Angioplastia Coronaria con Balón , Aterectomía Coronaria , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Femenino , Aterectomía Coronaria/efectos adversos , Aterectomía Coronaria/métodos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Retrospectivos , Mortalidad Hospitalaria , Angioplastia Coronaria con Balón/métodos , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/etiología , Angiografía Coronaria/métodos
20.
J Arrhythm ; 39(5): 803-806, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37799797

RESUMEN

In this study, we report two cases with oversensing due to air accumulation in the subcutaneous implantable cardioverter-defibrillator (S-ICD) device generator header. If trapped air in the header of the device is suspected, the re-connection procedure should be considered or the primary vector must be used, which might prevent oversensing.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...