Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 2 de 2
1.
Electrophoresis ; 44(23): 1889-1898, 2023 Dec.
Article En | MEDLINE | ID: mdl-37731003

The separation of wear microparticles in lubricating oil is crucial for improving the accuracy and throughput of the subsequent detection. However, there are few kinds of research on the separation of high-density metallic microparticles in high-viscosity lubricating oil. In this paper, a passive method for separating the metallic microparticles in oil is proposed. Gravity sedimentation was adopted to realize three-dimensional (3D) focusing of the particle by using an inclined capillary. The gravity-based 3D focusing made the sheath flow no longer responsible for the particle focusing and effectively reduced the sheath flow. Then, the separation of different-sized metallic microparticles was achieved in a horizontal channel with the aid of a sheath flow based on the different driving forces. The present method solved the problem of nonsynchronous separation of the particle in comparison to the traditional methods. This device has a simple structure with high separation efficiency, and it is easy to integrate with the detection channel. The influence of numerous parameters on the gravity-based focusing and separation was systematically studied by the numerical simulation and the experiment. The design criteria were established, which is useful in designing and employing the device, expanding its application to other non-neutral buoyancy particle separation cases, and opening up more prospects for microfluidic technology.


Microfluidic Analytical Techniques , Microfluidics , Particle Size , Microfluidics/methods , Viscosity
2.
Electrophoresis ; 43(21-22): 2217-2226, 2022 11.
Article En | MEDLINE | ID: mdl-36084168

Separation of microparticle in viscoelastic fluid is highly required in the field of biology and clinical medicine. For instance, the separation of the target cell from blood is an important prerequisite step for the drug screening and design. The microfluidic device is an efficient way to achieve the separation of the microparticle in the viscoelastic fluid. However, the existing microfluidic methods often have some limitations, including the requirement of the long channel length, the labeling process, and the low throughput. In this work, based on the elastic-inertial effect in the viscoelastic fluid, a new separation method is proposed where a gradually contracted microchannel is designed to efficiently adjust the forces exerted on the particle, eventually achieving the high-efficiency separation of different sized particles in a short channel length and at a high throughput. In addition, the separation of WBCs and RBCs is also validated in the present device. The effect of the flow rate, the fluid property, and the channel geometry on the particle separation is systematically investigated by the experiment. With the advantage of small footprint, simple structure, high throughput, and high efficiency, the present microfluidic device could be utilized in the biological and clinical fields, such as the cell analysis and disease diagnosis.


Cell-Derived Microparticles , Microfluidic Analytical Techniques , Particle Size , Microfluidics , Lab-On-A-Chip Devices , Cell Separation/methods
...