Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
PLoS One ; 17(7): e0270403, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35797275

RESUMEN

The search of separation hyperplanes is an efficient way to find rules with classification purposes. This paper presents an alternative mathematical programming formulation to existing methods to find a discriminant hyperplane. The hyperplane H is found by minimizing the sum of all the distances to the area assigned to the group each individual belongs to. It results in a convex optimization problem for which we find an equivalent linear programming problem. We demonstrate that H exists when the centroids of the two groups are not equal. The method is effective dealing with low and high dimensional data where reduction of the dimension is proposed to avoid overfitting problems. We show the performance of this approach with different data sets and comparisons with other classifications methods. The method is called LPDA and it is implemented in a R package available in https://github.com/mjnueda/lpda.


Asunto(s)
Programación Lineal
2.
Am J Ther ; 27(1): e62-e70, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31567196

RESUMEN

BACKGROUND: The automation of glucose control has been an important goal of diabetes treatment for many decades. The first artificial pancreas experiences were in-hospital, closely supervised, small-scale, and short-term studies that demonstrated their superiority over continuous subcutaneous insulin infusion therapy. At present, long-term outpatient studies are being conducted in free-living scenarios. AREAS OF UNCERTAINTY: The integration of multiple devices increases patients' burden and the probability of technical risks. Control algorithms must be robust to manage disturbance variables, such as physical exercise, meal composition, stress, illness, and circadian variations in insulin sensitivity. Extra layers of safety could be achieved through remote supervision. Dual-hormone systems reduce the incidence and duration of hypoglycemia, but the availability of stable pumpable glucagon needs to be solved. Faster insulin analogues are expected to improve all types of artificial pancreas. THERAPEUTIC ADVANCES: Artificial pancreas safety and feasibility are being demonstrated in outpatient studies. Artificial pancreas use increases the time of sensor-measured glucose in near-normoglycemia and reduces the risk of hyperglycemia and hypoglycemia. The benefits are observed both in single- and dual-hormone algorithms and in full- or semi-closed loop control. A recent meta-analysis including 41 randomized controlled trials showed that artificial pancreas use achieves a reduction of time in hyperglycemia (2 hours less than control treatment) and in hypoglycemia (20 minutes less); mean levels of continuous glucose sensor fell by 8.6 mg/dL over 24 hours and by 14.6 mg/dL overnight. The OpenAPS community uses Do It Yourself artificial pancreas in the real world since 2013, and a recent retrospective cross-over study (n = 20) compared continuous glucose sensor readings before and after initiation: mean levels of blood glucose fell by 7.4 mg/dL over 24 hours and time in range increased from 75.8% to 82.2% (92 minutes more). CONCLUSIONS: The outpatient use of artificial pancreas is safe and improves glucose control in outpatients with type 1 diabetes compared with the use of any type of insulin-based treatment. The availability of open-source solutions and data sharing is needed to foster the development of new artificial pancreas approaches and to promote the wide use of Big Data tools for knowledge discovery, decision support, and personalization.


Asunto(s)
Diabetes Mellitus Tipo 1/terapia , Páncreas Artificial , Algoritmos , Ritmo Circadiano/fisiología , Estudios Cruzados , Dieta , Ejercicio Físico/fisiología , Humanos , Estrés Psicológico/fisiopatología
3.
J Diabetes Sci Technol ; 12(2): 243-250, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29493361

RESUMEN

BACKGROUND: In type 1 diabetes mellitus (T1DM), patients play an active role in their own care and need to have the knowledge to adapt decisions to their daily living conditions. Artificial intelligence applications can help people with type 1 diabetes in decision making and allow them to react at time scales shorter than the scheduled face-to-face visits. This work presents a decision support system (DSS), based on glucose prediction, to assist patients in a mobile environment. METHODS: The system's impact on therapeutic corrective actions has been evaluated in a randomized crossover pilot study focused on interprandial periods. Twelve people with type 1 diabetes treated with insulin pump participated in two phases: In the experimental phase (EP) patients used the DSS to modify initial corrective decisions in presence of hypoglycemia or hyperglycemia events. In the control phase (CP) patients were asked to follow decisions without knowing the glucose prediction. A telemedicine platform allowed participants to register monitoring data and decisions and allowed endocrinologists to supervise data at the hospital. The study period was defined as a postprediction (PP) time window. RESULTS: After knowing the glucose prediction, participants modified the initial decision in 20% of the situations. No statistically significant differences were found in the PP Kovatchev's risk index change (-1.23 ± 11.85 in EP vs -0.56 ± 6.06 in CP). Participants had a positive opinion about the DSS with an average score higher than 7 in a usability questionnaire. CONCLUSION: The DSS had a relevant impact in the participants' decision making while dealing with T1DM and showed a high confidence of patients in the use of glucose prediction.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/métodos , Sistemas de Apoyo a Decisiones Clínicas , Diabetes Mellitus Tipo 1/sangre , Redes Neurales de la Computación , Telemedicina/métodos , Adulto , Glucemia/análisis , Estudios Cruzados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Telemedicina/instrumentación
4.
Diabetes Technol Ther ; 16(3): 172-9, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24152323

RESUMEN

OBJECTIVE: This study assessed the efficacy of a closed-loop (CL) system consisting of a predictive rule-based algorithm (pRBA) on achieving nocturnal and postprandial normoglycemia in patients with type 1 diabetes mellitus (T1DM). The algorithm is personalized for each patient's data using two different strategies to control nocturnal and postprandial periods. RESEARCH DESIGN AND METHODS: We performed a randomized crossover clinical study in which 10 T1DM patients treated with continuous subcutaneous insulin infusion (CSII) spent two nonconsecutive nights in the research facility: one with their usual CSII pattern (open-loop [OL]) and one controlled by the pRBA (CL). The CL period lasted from 10 p.m. to 10 a.m., including overnight control, and control of breakfast. Venous samples for blood glucose (BG) measurement were collected every 20 min. RESULTS: Time spent in normoglycemia (BG, 3.9-8.0 mmol/L) during the nocturnal period (12 a.m.-8 a.m.), expressed as median (interquartile range), increased from 66.6% (8.3-75%) with OL to 95.8% (73-100%) using the CL algorithm (P<0.05). Median time in hypoglycemia (BG, <3.9 mmol/L) was reduced from 4.2% (0-21%) in the OL night to 0.0% (0.0-0.0%) in the CL night (P<0.05). Nine hypoglycemic events (<3.9 mmol/L) were recorded with OL compared with one using CL. The postprandial glycemic excursion was not lower when the CL system was used in comparison with conventional preprandial bolus: time in target (3.9-10.0 mmol/L) 58.3% (29.1-87.5%) versus 50.0% (50-100%). CONCLUSIONS: A highly precise personalized pRBA obtains nocturnal normoglycemia, without significant hypoglycemia, in T1DM patients. There appears to be no clear benefit of CL over prandial bolus on the postprandial glycemia.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemia/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Páncreas Artificial , Algoritmos , Glucemia/metabolismo , Estudios Cruzados , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/fisiopatología , Femenino , Hemoglobina Glucada/metabolismo , Humanos , Hipoglucemia/metabolismo , Hipoglucemia/fisiopatología , Infusiones Subcutáneas , Masculino , Comidas , Periodo Posprandial , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo , Resultado del Tratamiento
5.
J Diabetes Sci Technol ; 7(4): 888-97, 2013 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-23911170

RESUMEN

BACKGROUND: Healthy diet and regular physical activity are powerful tools in reducing diabetes and cardiometabolic risk. Various international scientific and health organizations have advocated the use of new technologies to solve these problems. The PREDIRCAM project explores the contribution that a technological system could offer for the continuous monitoring of lifestyle habits and individualized treatment of obesity as well as cardiometabolic risk prevention. METHODS: PREDIRCAM is a technological platform for patients and professionals designed to improve the effectiveness of lifestyle behavior modifications through the intensive use of the latest information and communication technologies. The platform consists of a web-based application providing communication interface with monitoring devices of physiological variables, application for monitoring dietary intake, ad hoc electronic medical records, different communication channels, and an intelligent notification system. A 2-week feasibility study was conducted in 15 volunteers to assess the viability of the platform. RESULTS: The website received 244 visits (average time/session: 17 min 45 s). A total of 435 dietary intakes were recorded (average time for each intake registration, 4 min 42 s ± 2 min 30 s), 59 exercises were recorded in 20 heart rate monitor downloads, 43 topics were discussed through a forum, and 11 of the 15 volunteers expressed a favorable opinion toward the platform. Food intake recording was reported as the most laborious task. Ten of the volunteers considered long-term use of the platform to be feasible. CONCLUSIONS: The PREDIRCAM platform is technically ready for clinical evaluation. Training is required to use the platform and, in particular, for registration of dietary food intake.


Asunto(s)
Terapia Conductista/métodos , Enfermedades Cardiovasculares/prevención & control , Diabetes Mellitus/terapia , Estilo de Vida , Enfermedades Metabólicas/prevención & control , Obesidad/terapia , Telemedicina/métodos , Adulto , Enfermedades Cardiovasculares/etiología , Complicaciones de la Diabetes/prevención & control , Estudios de Factibilidad , Humanos , Internet , Enfermedades Metabólicas/etiología , Persona de Mediana Edad , Obesidad/complicaciones , Proyectos Piloto , Medicina de Precisión/métodos , Conducta de Reducción del Riesgo , Apoyo Social , Resultado del Tratamiento , Adulto Joven
6.
Diabetes Technol Ther ; 12(2): 95-104, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20105038

RESUMEN

BACKGROUND: Closed-loop control algorithms in diabetes aim to calculate the optimum insulin delivery to maintain the patient in a normoglycemic state, taking the blood glucose level as the algorithm's main input. The major difficulties facing these algorithms when applied subcutaneously are insulin absorption time and delays in measurement of subcutaneous glucose with respect to the blood concentration. METHODS: This article presents an inverse controller (IC) obtained by inversion of an existing mathematical model and validated with synthetic patients simulated with a different model and is compared with a proportional-integral-derivative controller. RESULTS: Simulated results are presented for a mean patient and for a population of six simulated patients. The IC performance is analyzed for both full closed-loop and semiclosed-loop control. The IC is tested when initialized with the heuristic optimal gain, and it is compared with the performance when the initial gain is deviated from the optimal one (+/-10%). CONCLUSIONS: The simulation results show the viability of using an IC for closed-loop diabetes control. The IC is able to achieve normoglycemia over long periods of time when the optimal gain is used (63% for the full closed-loop control, and it is increased to 96% for the semiclosed-loop control).


Asunto(s)
Algoritmos , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/terapia , Insulina/administración & dosificación , Modelos Biológicos , Simulación por Computador , Humanos
7.
J Diabetes Sci Technol ; 3(5): 1039-46, 2009 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-20144417

RESUMEN

BACKGROUND: The use of telemedicine for diabetes care has evolved over time, proving that it contributes to patient self-monitoring, improves glycemic control, and provides analysis tools for decision support. The timely development of a safe and robust ambulatory artificial pancreas should rely on a telemedicine architecture complemented with automatic data analysis tools able to manage all the possible high-risk situations and to guarantee the patient's safety. METHODS: The Intelligent Control Assistant system (INCA) telemedical artificial pancreas architecture is based on a mobile personal assistant integrated into a telemedicine system. The INCA supports four control strategies and implements an automatic data processing system for risk management (ADP-RM) providing short-term and medium-term risk analyses. The system validation comprises data from 10 type 1 pump-treated diabetic patients who participated in two randomized crossover studies, and it also includes in silico simulation and retrospective data analysis. RESULTS: The ADP-RM short-term risk analysis prevents hypoglycemic events by interrupting insulin infusion. The pump interruption has been implemented in silico and tested for a closed-loop simulation over 30 hours. For medium-term risk management, analysis of capillary blood glucose notified the physician with a total of 62 alarms during a clinical experiment (56% for hyperglycemic events). The ADP-RM system is able to filter anomalous continuous glucose records and to detect abnormal administration of insulin doses with the pump. CONCLUSIONS: Automatic data analysis procedures have been tested as an essential tool to achieve a safe ambulatory telemedical artificial pancreas, showing their ability to manage short-term and medium-term risk situations.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/efectos de los fármacos , Diabetes Mellitus Tipo 1/terapia , Hipoglucemiantes/administración & dosificación , Sistemas de Infusión de Insulina , Insulina/administración & dosificación , Páncreas Artificial , Procesamiento de Señales Asistido por Computador , Telemedicina/instrumentación , Atención Ambulatoria , Automatización , Alarmas Clínicas , Estudios Cruzados , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/diagnóstico , Diagnóstico por Computador , Carbohidratos de la Dieta/administración & dosificación , Carbohidratos de la Dieta/metabolismo , Falla de Equipo , Humanos , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Valor Predictivo de las Pruebas , Ensayos Clínicos Controlados Aleatorios como Asunto , Estudios Retrospectivos , Gestión de Riesgos , Integración de Sistemas , Terapia Asistida por Computador , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA