Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Clin Ophthalmol ; 18: 1933-1944, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38983598

RESUMEN

Purpose: To assess the refractive and visual outcomes of hyperopic and astigmatic eyes implanted with a monofocal, aspheric, bitoric intraocular lens (IOL) with plate haptics following cataract surgery. Methods: The study evaluated 51 eyes implanted with the AT TORBI 709M IOL (Carl Zeiss Meditec AG, Jena, Germany) during a follow-up of 12-months. Refractive error, rotational stability, monocular uncorrected distance visual acuity (UDVA), monocular corrected distance visual acuity (CDVA), and contrast sensitivity were analyzed at 1-, 6-, and 12-months post-surgery. Results: At 12 months, the cumulative CDVA was 20/25 in 94.12% of eyes and 20/32 or better in 98.04%. The UDVA was the same as, or better than, the CDVA in 88.24% of eyes. The mean logMAR UDVA and CDVA values were 0.06 ± 0.11 and 0.00 ± 0.08, respectively. In addition, 92.16% of eyes were within ±0.50 D and 98.04% were within ±1.00 D of a spherical equivalent, and 86.27% of eyes had refractive astigmatism ≤0.50D and 100% were ≤1.00D. The mean spherical equivalent was 0.21 ± 0.31D and the mean refractive cylinder 0.34 ± 0.27D. The IOL rotation was 1.18 ± 1.35 degrees and all eyes had a rotation ≤5 degrees. The log contrast sensitivity functions were good and similar for all spatial frequencies during follow-up. Conclusion: Our results demonstrate that implantation of the AT TORBI 709M IOL in hyperopic and astigmatic eyes is effective and safe. The visual and refractive outcomes were good, showing excellent rotational stability.

2.
Clin Ophthalmol ; 17: 3215-3224, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37915319

RESUMEN

Purpose: To evaluate the refractive and visual outcomes of eyes implanted with monofocal, optimized, aspheric, hydrophobic acrylic intraocular lenses (IOL) following cataract surgery. Methods: The study assessed 55 eyes implanted with CT LUCIA® 621P IOLs (Carl Zeiss Meditec AG, Jena, Germany) at 3-months postsurgery. The main outcome measures were refractive error, monocular corrected distance visual acuity (CDVA), monocular uncorrected distance visual acuity (UDVA), photopic and mesopic contrast sensitivity, and wavefront aberrations. Patients were asked to complete the Catquest-9SF questionnaire. Results: At 3 months, the cumulative Snellen visual acuity was 20/20 in 94.55% of eyes and 20/25 or better in 100%. The difference between the UDVA and CDVA was either the same (70.91%) or better (29.09%) in all eyes. The mean Snellen decimal UDVA and DCVA were 1.07 ± 0.15 and 1.13 ± 0.11, respectively. The safety and efficacy indexes were 1.48 and 1.40, respectively. 47.27% of eyes showed a spherical equivalent ±0.13 D, with 92.73% of the eyes were within ±0.50 D and all eyes were within ±1.00 D. The mean spherical equivalent was -0.03 ± 0.30 D and the mean refractive cylinder -0.36 ± 0.34 D. The log photopic and mesopic contrast sensitivity functions were good and similar for all spatial frequencies. All patients reported being either fairly satisfied (score 3) or very satisfied (score 4) with their vision (mean = 3.64 ± 0.49). No intra- and postoperative complications were reported during the 3 months of follow-up. Conclusion: The current study demonstrates that excellent visual and refractive outcomes, as well as patient satisfaction, can be achieved after cataract surgery with optimized, aspheric CT LUCIA 621P monofocal IOLs.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA