Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Injury ; 55(6): 111574, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38669892

RESUMEN

INTRODUCTION: Multiplanar mesh plating of patella fractures has become more popular in recent years. It was the goal of this study to compare the biomechanical stability of cannulated screw with anterior tension band to multiplanar mesh plating for fixation of transverse patella fractures in cadaver specimens. MATERIALS AND METHODS: Eight matched pairs of fresh frozen cadaveric knees were obtained and soft tissues dissected leaving the extensor mechanism, joint capsule, and retinaculum intact. Transverse fractures were created at the mid-portion of the patella. For each pair, one specimen was repaired using cannulated screws with anterior tension band, and the second was repaired using multiplanar mesh plating. Each specimen underwent cyclic extension loading with loads increasing by 1.1 kg after every 50 cycles. Interfragmentary displacement was measured at the end of each interval at both 5° and 45° of knee flexion angle, with fixation failure defined by >2 mm displacement. RESULTS: The specimens fixed with multiplanar mesh plating survived more cycles and higher loads than the specimens fixed with cannulated screws with anterior tension band (p = 0.011 comparing survival plots). After 150 cycles of extension loading, 3 of 8 of the specimens fixed with screws/tension band had failed, whereas none of the mesh plated specimens had failed. After 400 cycles, 7 of 8 of the screws/tension band had failed, whereas half of the mesh plated specimens had failed. CONCLUSIONS: While a more technically challenging and expensive technique, mesh plating for patella fractures appears to offer greater durability than traditional cannulated screw with tension banding.


Asunto(s)
Placas Óseas , Tornillos Óseos , Cadáver , Fijación Interna de Fracturas , Fracturas Óseas , Rótula , Humanos , Rótula/cirugía , Rótula/lesiones , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fenómenos Biomecánicos , Fracturas Óseas/cirugía , Fracturas Óseas/fisiopatología , Mallas Quirúrgicas , Masculino , Femenino , Anciano , Ensayo de Materiales , Persona de Mediana Edad , Rango del Movimiento Articular
2.
OTA Int ; 6(3): e275, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37342096

RESUMEN

Purpose: To evaluate the use of computed tomography (CT) imaging as a diagnostic tool for elbow arthrotomies using a standardized cadaveric arthrotomy model. Method: Nineteen intact fresh frozen cadaver elbows were CT scanned using 2 mm cuts with sagittal and coronal reformats in the plane of the joint and used as controls. An elbow arthrotomy at the posterocentral arthroscopic portal site was performed in all specimens using a 4.5 millimeter trocar. After arthrotomy, all elbows underwent a second CT scan followed by a standard saline load test (SLT). Images were randomized and reviewed by 2 blinded, independent reviewers. Bimodal scoring was performed for each specimen with regard to the presence of an arthrotomy indicated by presence of air in the joint. Regarding the SLT, saline exiting the arthrotomy wound was considered a positive test. Results: CT scans were found to have 100% sensitivity and 86% specificity for diagnosing elbow arthrotomies. Interrater reliability calculated with Cohen kappa statistic was near perfect at r = 0.89. The SLT had a sensitivity of 79% when 20 mL was injected. A total of 25 mL of saline was required to be injected for a sensitivity greater than 95%. Conclusion: This study demonstrates that CT scan is a reliable and less technically demanding method of diagnosis arthrotomies with high interrater reliability and high sensitivity and with results comparable with SLT. This technique may be useful in centers where trained providers are not readily available to perform SLT. Clinical study is required to validate our results. Level of Evidence: Level II.

3.
Injury ; 53(10): 3102-3108, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36030094

RESUMEN

INTRODUCTION: Little data exists regarding the effects of vaporized nicotine on healing. Our goal was to compare vaporized nicotine, combusted nicotine and control with respect to bone healing in a rat femur fracture model. MATERIALS AND METHODS: Forty-five male Sprague Dawley rats were divided into three equal cohorts. Rats were exposed to two cigarettes daily, an equivalent dose of vaporized nicotine, or control, six days a week. Exposures occurred for 4 weeks prior to iatrogenic femur fracture and intramedullary repair. Four additional weeks of exposure occurred prior to sacrifice. Radiographic, biomechanical and histologic analysis was conducted. RESULTS: No significant difference between the three groups was identified for total mineralized bone volume (p = 0.14), total volume of mature bone (p = 0.12) or immature bone (p = 0.15). Importantly, less total mineralized bone volume and immature bone volume was seen in the vaporized nicotine group compared to combusted tobacco, but results were not significant. Biomechanical testing revealed no significant difference in group torsional stiffness (p = 0.92) or maximum torque (p = 0.31) between the three groups. On histologic analysis, chi-square testing showed no significant difference in any category. CONCLUSIONS: This exploratory study compared combusted nicotine, vaporized nicotine and a control on rat femur fractures. While no statistically significant differences were identified, there were trends showing less total mineralized bone volume and immature bone volume in the vaporized nicotine group compared to the other groups. Additional study is warranted based on our findings.


Asunto(s)
Fumar Cigarrillos , Fracturas del Fémur , Animales , Fenómenos Biomecánicos , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/tratamiento farmacológico , Fracturas del Fémur/cirugía , Fémur/cirugía , Curación de Fractura , Masculino , Nicotina/farmacología , Ratas , Ratas Sprague-Dawley , Nicotiana
4.
Arch Orthop Trauma Surg ; 142(12): 3599-3603, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33993360

RESUMEN

INTRODUCTION: It was the goal of this study to determine if the Orthopaedic Trauma Association Open Fracture Classification (OTA-OFC) correlates with complication rates and to determine if it can be used as a predictive tool in the treatment of open tibial shaft fractures. MATERIALS AND METHODS: Retrospective review from two high-volume level 1 trauma centers of open tibial shaft fractures over a 5 year period. Variables of interest included OTA-OFC, type of wound closure, 90-day wound complication, unplanned re-operation, non-union, and amputation. RESULTS: 501 consecutive open tibial shaft fractures. 57.3% (n = 287) were closed primarily; local soft tissue advancement/rotational flap was used in 9.6% (n = 48); free soft tissue transfer used in 22.8% (n = 114); 8.6% (n = 43) required amputation. Of those followed for 90 days (n = 419), 45 (9.0%) had a wound complication, of which 40 (8%) required an unplanned reoperation. 40 (8.0%) patients went on to a documented non-union. All OTA-OFC classification groups significantly correlated with type of definitive closure (r = 0.18-0.81, p < 0.05) with OTA-OFC skin showing the strongest correlation (r = 0.81). OTA-OFC bone loss weakly correlated with wound complication (r = 0.12, p = 0.02) and no OTA-OFC classification correlated with the need for an unplanned secondary procedure. OTA-OFC skin, muscle and arterial all weakly correlated with non-union (r = 0.18-0.25, p < 0.05). OTA-OFC muscle was predictive of non-union (OR = OR = 2.2, 95% CI = 1.2-4.1) and amputation (OR 9.3, 95% CI = 3.7-23.7). OTA-OFC arterial was also predictive of amputation (OR 4.8, 95% CI = 2.5-9.3). CONCLUSIONS: The OTA-OFC correlates variably with the type of definitive closure, the development of a 90-day wound complication, and the occurrence of a non-union. Importantly, OTA-OFC muscle classification is predictive of non-union while both OTA-OFC muscle and arterial were predictive of amputation.


Asunto(s)
Fracturas Abiertas , Ortopedia , Fracturas de la Tibia , Humanos , Fracturas Abiertas/cirugía , Fracturas Abiertas/complicaciones , Estudios Retrospectivos , Tibia , Pronóstico , Fracturas de la Tibia/cirugía , Fracturas de la Tibia/complicaciones , Resultado del Tratamiento , Curación de Fractura
5.
J Orthop Trauma ; 36(3): e111-e115, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-34387566

RESUMEN

OBJECTIVES: To evaluate the perceived utility and associated charges of the anteroposterior (AP) radiograph during rotational ankle fracture postoperative follow-up. DESIGN: Survey study with charge analysis using published data at 50 orthopaedic hospitals in the United States. SETTING: Not Applicable. PARTICIPANTS: Orthopaedic Trauma Association Members with an active email address who were invited and interested in answering a survey. RESULTS: Ninety-four percent of respondents stated that they did routinely obtain an AP radiograph during rotational ankle fracture follow-up. However, 57% thought that the AP view should be eliminated from standard follow-up and only 51% found this view useful after initial treatment. CHARGE ANALYSIS: The mean difference between a 2-view and 3-view ankle radiograph series was $102.00. Using this value and the assumption that each patient with a rotational ankle fracture gets 3 follow-up radiographs, there is the potential for a charge reduction of $306 per patient. Assuming over 134,000 rotational ankle fractures, a charge reduction of 41 million US dollars (USD) per year is possible if the AP image is routinely removed. Actual savings are likely to be less based on agreed on payer rates. Although less easy to quantify, there is also a potential reduction of radiation exposure, radiologists' interpretation time, and data storage. CONCLUSIONS: Routine AP radiographs should potentially be eliminated from routine postoperative ankle x-ray protocols based on this survey of experienced orthopaedic surgeons. If this specific radiograph is ordered on a case-by-case basis, then significant savings may occur.


Asunto(s)
Fracturas de Tobillo , Ortopedia , Tobillo , Fracturas de Tobillo/diagnóstico por imagen , Fracturas de Tobillo/cirugía , Articulación del Tobillo , Humanos , Encuestas y Cuestionarios
6.
Injury ; 52(11): 3340-3343, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34509285

RESUMEN

OBJECTIVES: There is increasing interest regarding the risks and benefits of intrawound antibiotics applied directly to surgical wounds for the prevention of infection following orthopaedic trauma surgery. The purpose of this study was to investigate the economic justifiability of vancomycin and tobramycin powders for infection prophylaxis in orthopaedic trauma surgery. METHODS: The cost of vancomycin and tobramycin powders, infection rates and costs of treating surgical site infections were obtained from our institution's records and existing literature. A break-even analysis was then performed using vancomycin powder only, tobramycin powder only and combined vancomycin and tobramycin powders to determine the respective absolute risk reduction (ARR) in infection rate needed to make the prophylactic application of each therapy type break-even. RESULTS: At our institutional pricing of $20.64 and $75.80 for 1g vancomycin and 1.2g tobramycin, respectively, use of each individually would be economically justified if it reduced an average infection rate of 4.3% by an ARR of 0.02% and 0.07%, respectively. Used in combination for $90.66, the ARR was 0.09%. Varying cost of treating infection from $5,000-$200,000 while maintaining cost of antibiotic powder at $90.66 demonstrated a range in ARR from 1.93% to 0.05%, respectively. At the same cost of $90.66 but varying infection rate from 1% to 25% did not affect ARR, which was constant at 0.09%. CONCLUSIONS: Considering the cost of vancomycin and tobramycin powder at our institution, the application of these powders, whether independently or in combination, appear to be economically justifiable for infection prevention in orthopaedic trauma surgery.


Asunto(s)
Ortopedia , Vancomicina , Antibacterianos/uso terapéutico , Profilaxis Antibiótica , Humanos , Polvos , Infección de la Herida Quirúrgica/tratamiento farmacológico , Infección de la Herida Quirúrgica/prevención & control , Tobramicina
7.
Am J Sports Med ; 49(9): 2522-2527, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34097540

RESUMEN

BACKGROUND: The use of cannabis is common among athletes and the US population at large. Cannabinoids are currently being evaluated as alternatives to opioid medications for chronic pain management. However, the effects of recreational and/or medical use of delta-9-tetrahydrocannabinol (THC) and cannabidiol (CBD) on musculoskeletal injury and healing remain largely unknown. HYPOTHESIS/PURPOSE: The purpose of this study was to evaluate the biomechanical effects of CBD and THC on tendon-to-tendon healing in a rat Achilles tendon repair model. The hypothesis was that rats administered CBD would demonstrate decreased tensile load to failure of surgically repaired Achilles tendons compared with the THC and control groups. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 33 Sprague Dawley rats underwent Achilles tendon surgical transection and repair and were randomized to receive subcutaneous injection of THC, CBD, or vehicle once daily starting on the day of surgery and for 5 total days. After sacrifice, biomechanical tensile load-displacement testing was performed to determine Achilles tendon load to failure and stiffness. Data were analyzed by 1-way analysis of variance. RESULTS: The THC group demonstrated the highest median load to failure, 18.7 N (95% CI, 15.3-19.2 N); the CBD group had the second highest at 16.9 N (95% CI, 15.1-19.8 N), and the control group had the lowest at 14.4 N (95% CI, 12.1-18.3 N). Stiffness was highest in the THC group at 4.1 N/mm (95% CI, 2.7-5.1 N/mm) compared with 3.6 N/mm (95% CI, 2.9-4.1 N/mm) for the CBD group and 3.6 N/mm (95% CI, 2.8-4.3 N/mm) for the control group. No statistically significant differences for strength and stiffness were observed between the groups. CONCLUSION: In this pilot study using an animal tendon-to-tendon repair model, neither THC nor CBD resulted in altered biomechanical characteristics compared to control. CLINICAL RELEVANCE: Cannabinoids do not appear to adversely affect Achilles tendon healing.


Asunto(s)
Tendón Calcáneo , Cannabidiol , Cannabis , Animales , Ratas , Tendón Calcáneo/cirugía , Cannabidiol/farmacología , Dronabinol/farmacología , Proyectos Piloto , Ratas Sprague-Dawley
8.
J Orthop Trauma ; 35(6): e184-e188, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33079834

RESUMEN

OBJECTIVES: To correlate domains of the Orthopaedic Trauma Association Open Fracture Classification (OTA-OFC) in open upper extremity injuries with type of definitive soft-tissue closure, complication rates, and unanticipated return to the operating room for complication. DESIGN: Retrospective review of prospectively collected data. SETTING: Level I trauma center. PATIENTS: Two hundred thirty-four consecutive open upper extremity fractures. INTERVENTION: Operative management of open upper extremity fractures. MAIN OUTCOME MEASUREMENTS: Type of definitive closure, 90-day wound complication, and wound complication necessitating return to the operating room. RESULTS: Two hundred eighty injuries were identified, and 234 had sufficient data for analysis. Eighty-four percent (196/234) of open wounds were closed primarily, 7% (16/234) required a skin graft, and 4% (9/234) required rotational or free flap. Thirteen percent (22/166) of those followed for 90 days had a wound complication, and 50% of those with complication required a return to the OR. All OTA-OFC classifications statistically significantly correlated with type of closure (P < 0.001), with skin having a high correlation (r = 0.79), muscle (r = 0.49) and contamination (r = 0.47) moderate correlations, and arterial (r = 0.32) and bone loss (r = 0.33) low correlations. OTA-OFC muscle classification was predictive of 90-day wound complication (OR 0.31, 95% confidence interval 0.07-0.21). OTA-OFC domains correlated variably with return to the OR. CONCLUSION: OTA-OFC clinically correlates with definitive wound management and 90-day wound complication in open upper extremity fractures. OTA-OFC skin classification has a high correlation with the type of definitive wound closure. OTA-OFC muscle was the only domain that correlated with 90-day wound complication and was predictive of 90-day wound complication. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Traumatismos del Brazo , Fracturas Abiertas , Ortopedia , Fracturas Abiertas/cirugía , Humanos , Estudios Retrospectivos , Extremidad Superior/cirugía
9.
Bone Jt Open ; 1(8): 481-487, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33215142

RESUMEN

AIMS: To compare results of institutional preferences with regard to treatment of soft tissues in the setting of open tibial shaft fractures. METHODS: We present a retrospective review of open tibial shaft fractures at two high-volume level 1 trauma centres with differing practices with regard to the acute management of soft tissues. Site 1 attempts acute primary closure, while site 2 prefers delayed closure/coverage. Comparisons include percentage of primary closure, number of surgical procedures until definitive closure, percentage requiring soft tissue coverage, and percentage of 90-day wound complication. RESULTS: Overall, there were 219 patients at site 1 and 282 patients at site 2. Differences in rates of acute wound closure were seen (168 (78%) at site 1 vs 101 (36%) at site 2). A mean of 1.5 procedures for definitive closure was seen at site 1 compared to 3.4 at site 2. No differences were seen in complication, nonunion, or amputation rates. Similar results were seen in a sub-analysis of type III injuries. CONCLUSION: Comparing outcomes of open tibial shaft fractures at two institutions with different rates initial wound management, no differences were seen in 90-day wound complications, nonunion rates, or need for amputation. Attempted acute closure resulted in a lower number of planned secondary procedures when compared with planned delayed closure. Providers should consider either acute closure or delayed coverage based on the injury characteristics, surgeon preference and institutional resources without concern that the decision at the time of index surgery will lead to an increased risk of complication.Cite this article: Bone Joint Open 2020;1-8:481-487.

10.
HSS J ; 16(1): 81-85, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32015744

RESUMEN

BACKGROUND: Blade plates are frequently used for internal fixation following proximal femoral varus rotational osteotomy to treat hip dysplasia in children with cerebral palsy. Recently, cannulated blade plates with the option for a proximal locking screw have demonstrated ease of insertion and low complication rates. Although there are two commonly used blade plates with a proximal screw option, no comparison of their biomechanical profiles has been undertaken. QUESTIONS/PURPOSES: Our study sought to compare the structural properties under axial loading, as well as the biomechanical contribution of a proximal screw, of two different 90° cannulated blade plates designed for pediatric proximal femurs. Plate A has a hole distal to the blade designed to attach a plate inserter, through which a 3.5-mm non-locking cortical screw could be placed. Plate B has a threaded hole distal to the blade designed to accept a 3.5-mm locking screw. METHODS: Plate A and plate B were inserted into 33 left pediatric synthetic proximal femurs. Axial loading to failure of plate A with and without a proximal screw was compared to that of plate B with and without a proximal screw. An additional 10 samples using plate B, with and without a proximal locking screw, were tested in tension to quantify the effect of the proximal screw on pullout strength. RESULTS: Plate B failed at a higher axial load than plate A. The addition of a proximal screw did not affect the axial load to failure for either plate. Pullout testing revealed that blade plates fixed with the proximal screw failed in tension at a significantly higher load (856.3 ± 120.9 N) than those without proximal fixation (68.1 ± 9.3 N, p < 0.001). CONCLUSIONS: Plate B failed at a higher axial load in biomechanical testing, likely related to differences in its design. The addition of a proximal screw did not increase the axial loading properties of the blade plate construct but did increase the pullout strength by a factor of 12. These results may be used to influence implant selection and post-operative rehabilitation following proximal femoral osteotomies in children.

11.
J Am Acad Orthop Surg ; 28(4): e139-e144, 2020 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-31567898

RESUMEN

MRI provides diagnostic three-dimensional imaging and remains extremely important in the diagnosis and management of spinal trauma as well as other acute traumatic injuries, including those of the extremities. The American Society for Testing and Materials has created standards against which all implantable medical devices are tested to ensure safety in an MR environment. Most implantable passive orthopaedic devices can undergo MRI without consequence to the patient. However, the American Society for Testing and Materials has recently updated its terminology resulting in confusion among providers and institutions. Primary safety concerns are radiofrequency-induced heating and magnetically induced torque or displacement. These safety concerns have emerged as a recent source of debate, particularly regarding the imaging of patients with external fixation and cervical immobilization devices in place. Surveys have shown a lack of consensus among radiologists regarding this issue. Having an institutional protocol in place for the imaging of these patients streamlines the diagnosis and early stabilization of certain polytraumatized patients. The purpose of this review is to summarize the pertinent literature as well as the current industry recommendations regarding the safety of commonly used external fixation, cervical immobilization, and traction devices in the MR environment.


Asunto(s)
Seguridad de Equipos/normas , Imagen por Resonancia Magnética/normas , Prótesis e Implantes , Humanos , Metales
12.
Arch Orthop Trauma Surg ; 140(1): 25-31, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31134373

RESUMEN

BACKGROUND: The purpose of this study was to evaluate the effect of ankle plantarflexion and the axial location of measurement on quantitative syndesmosis assessment. METHODS: Twelve fresh-frozen cadaveric specimens were secured in three positions of ankle plantarflexion (0°, 15°, and 30°) using an ankle-spanning external fixator and underwent CT scans at each position. Syndesmotic measurements were obtained on axial images using three previously described methods (six measurements) at the level of the tibial plafond and 1 cm proximal to the plafond. Method 1 evaluated the distance between the most anterior and posterior aspects of the fibula and tibia. Method 2 measured medial-lateral diastasis of the anterior and posterior aspects of the fibula, and fibular anterior-posterior translation. Method 3 evaluated axial rotation of the fibula. All measurements were performed by two independent observers. Inter-rater reliability of each measurement was evaluated using intra-class coefficients. Repeated measures analysis of variance (RM-ANOVA) was performed to evaluate within-specimen differences in measurements obtained at varying ankle positions. RESULTS: The anterior incisura component of method 1 demonstrated poor-to-moderate inter-rater reliability across all ankle positions and at both measurement locations. Inter-rater reliability was highest for method 2, especially when measured 1 cm proximal to the plafond. Method 3 demonstrated moderate reliability 1 cm proximal to the plafond. After correcting for multiple comparisons, RM-ANOVA and pairwise analysis revealed that none of the measurements changed significantly with varying ankle position. CONCLUSION: The inter-rater reliability of the most common method of syndesmotic evaluation (method 1) was found to be lower than in previous studies. The most reliable syndesmotic evaluation can be made by measuring diastasis and anteroposterior translation 1 cm proximal to the plafond (method 2). Ankle position from 0° to 30° of plantarflexion did not change the measurements obtained. LEVEL OF EVIDENCE: IV.


Asunto(s)
Tobillo/diagnóstico por imagen , Postura/fisiología , Tomografía Computarizada por Rayos X , Peroné/diagnóstico por imagen , Humanos , Reproducibilidad de los Resultados , Tibia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas
13.
J Am Acad Orthop Surg ; 28(8): 309-315, 2020 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-31851021

RESUMEN

Open fractures are often associated with high-energy trauma and have an increased risk of infection because of surrounding soft-tissue damage and the introduction of environmental contaminants that may communicate with the fracture site. The Gustilo-Anderson classification of open fractures has been used to guide prophylactic antibiotic therapy because different types of open fracture have been shown to have varying rates of surgical site infections with different combinations of pathogens. Prophylactic treatment with various classes of antibiotics, including penicillins and cephalosporins, aminoglycosides, and fluoroquinolones, has evolved over the past half century. More recently, broader spectrum agents including monobactams and glycopeptides have been used for additional coverage. Duration of antibiotic therapy remains variable between institutions, and antibiotic choice is not standardized. Coverage for nosocomial and multidrug-resistant organisms is an ongoing area of clinical research.


Asunto(s)
Antibacterianos/clasificación , Profilaxis Antibiótica , Fracturas Abiertas/complicaciones , Infección de Heridas/etiología , Infección de Heridas/prevención & control , Antibacterianos/administración & dosificación , Infección Hospitalaria/etiología , Infección Hospitalaria/microbiología , Infección Hospitalaria/prevención & control , Farmacorresistencia Bacteriana , Resistencia a Múltiples Medicamentos , Humanos , Infección de Heridas/microbiología
14.
JBJS Case Connect ; 9(4): e0505, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31815807

RESUMEN

CASE: We describe a case of septic hip arthritis and enterocutaneous fistula formation caused by the seeding of a hip joint during hip arthroscopy performed in the setting of a psoas abscess. Treatment consisted of multiple debridements and femoral head resection with subsequent total hip arthroplasty. CONCLUSIONS: This case highlights the importance of a thorough history, physical examination, and assessment of available imaging before proceeding to surgery, even when the procedure is one considered to have minimal risks, such as arthroscopy.


Asunto(s)
Artritis Infecciosa/etiología , Artroscopía/efectos adversos , Enfermedad de Crohn/complicaciones , Fístula Intestinal/complicaciones , Complicaciones Posoperatorias/etiología , Absceso del Psoas/complicaciones , Adulto , Artritis Infecciosa/diagnóstico por imagen , Errores Diagnósticos , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía , Humanos , Fístula Intestinal/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Complicaciones Posoperatorias/diagnóstico por imagen , Absceso del Psoas/diagnóstico por imagen , Radiografía
15.
HSS J ; 15(2): 115-121, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31327941

RESUMEN

BACKGROUND: Operative indications for supination-external rotation (SER) ankle fractures depend on the integrity of the medial structures. Despite the importance of assessing deep deltoid ligament injuries, the accuracy of common diagnostic tests has not been established. QUESTIONS/PURPOSES: The objective of this study was to compare the ability of injury (non-stress) and stress radiographs and magnetic resonance imaging (MRI) to diagnose deep deltoid ligament ruptures in operative SER ankle fractures. METHODS: Patients were included who underwent surgical fixation of SER ankle fractures and had appropriate injury and manual stress test radiographs, pre-operative ankle MRI, and intra-operative assessment of deep deltoid integrity by direct visualization. The medial clear space (MCS) was considered positive for all values over 5 mm on the injury or stress mortise radiographs. MRI analysis of the deep deltoid ligament injury was performed by blinded fellowship-trained musculoskeletal radiologists. Intra-operative direct visualization and assessment of the deltoid was performed using a direct medial ankle approach at the time of operative fracture fixation. RESULTS: Using intra-operative visualization as the gold standard, MCS measurements and MRI had differing abilities to diagnose a deep deltoid rupture. In cases where the MCS was less than 5 mm on injury radiographs and stress tests were performed, MCS measurements were much less accurate than MRI in predicting deltoid ruptures (46% versus 79%, respectively) with a high false positive rate (80%). In contrast, an MCS measurement of greater than 5 mm on injury radiographs was a strong predictor of deep deltoid rupture (accuracy of 95%). CONCLUSION: Compared with direct visualization of the deltoid ligament intra-operatively, these data support proceeding with surgery when the MCS on injury radiographs is greater than 5 mm without any additional stress tests or advanced imaging. When the MCS is less than 5 mm, we recommend MRI analysis because of its increased accuracy and decreased false positive rate. Improving our ability to diagnose deltoid ruptures will contribute to more effective management of patients with SER ankle fractures.

16.
J Foot Ankle Surg ; 58(4): 669-673, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30962109

RESUMEN

Recent literature has reported an uncategorized hyperplantarflexion variant ankle fracture characterized by a posteromedial fragment separate from the posterior or medial malleolar fragments. The current study sought to determine whether the outcomes for surgically treated hyperplantarflexion variant fractures are similar to the more common supination external rotation (SER) IV fractures. A prospective registry of operatively treated ankle fractures was queried to create 2 age- and gender-matched cohorts: hyperplantarflexion variant and SER IV fractures. Each cohort had 23 patients (18 females), and matched pairs were within 2 years of age at the date of surgery. Patient demographics, comorbidities, and Foot and Ankle Outcomes Scores at minimum 12 months after the index surgery were compared. The cohorts were similar with respect to body mass index, the length of the clinical follow-up, medical comorbidities, dislocation rate, and postoperative articular incongruity (p > .05). Patient-reported outcomes demonstrated no statistically or clinically significant differences within any domain and were as follows: symptoms (70.8 versus 77.8, p = .11), pain (80.7 versus 85.0, p = .33), activities of daily living (83.7 versus 89.2, p = .23), sports (67.4 versus 73.4, p = .33), and quality of life (57.3 versus 63.9, p = .24) for the hyperplantarflexion and SER IV groups, respectively. No significant differences were found in the rang`e of motion for dorsiflexion (17.7° versus 18.1°, p = .52) or for plantarflexion (48.6° versus 47.1°, p = .71). Patients treated surgically for hyperplantarflexion variant ankle fractures have similar 1-year clinical outcomes when compared with the more common SER IV fracture patterns, provided that the injury is correctly identified preoperatively and treated appropriately.


Asunto(s)
Fracturas de Tobillo/cirugía , Fractura-Luxación/cirugía , Fijación Interna de Fracturas , Adolescente , Adulto , Anciano , Fracturas de Tobillo/clasificación , Fracturas de Tobillo/diagnóstico por imagen , Estudios de Cohortes , Femenino , Fractura-Luxación/diagnóstico por imagen , Fijación Interna de Fracturas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Medición de Resultados Informados por el Paciente , Complicaciones Posoperatorias , Radiografía , Rotación , Supinación , Resultado del Tratamiento , Adulto Joven
17.
J Am Acad Orthop Surg ; 26(24): 864-871, 2018 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-30256339

RESUMEN

Atypical femur fractures associated with long-term bisphosphonate use can be challenging injuries to manage. Not only do they have a prolonged healing time and increased rate of nonunion as compared to typical femur fractures, intraoperative complications are not infrequent and can be catastrophic. Given the pathologic nature of these fractures, a multidisciplinary approach to the patient's care is necessary. Treatment begins with medical optimization and careful surgical planning. Radiographic characteristics of the fracture and femoral osteology dictate reduction strategy, adjunctive surgical techniques, and implant choice. Intraoperative complications including malreduction, iatrogenic fracture, and fracture propagation can be avoided with thoughtful planning. The purpose of this article is to discuss the technical aspects of surgical management of atypical femur fractures. We also discuss management of intraoperative complications and treatment failure. Finally, we provide an update on recommendations for postoperative medical treatment and management of the contralateral femur.


Asunto(s)
Conservadores de la Densidad Ósea/efectos adversos , Difosfonatos/efectos adversos , Fracturas del Fémur/cirugía , Procedimientos Ortopédicos/métodos , Conservadores de la Densidad Ósea/administración & dosificación , Clavos Ortopédicos , Placas Óseas , Trasplante Óseo , Difosfonatos/administración & dosificación , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/epidemiología , Fémur/anatomía & histología , Fémur/patología , Curación de Fractura , Humanos , Complicaciones Intraoperatorias/prevención & control , Cuidados Posoperatorios
18.
Arch Orthop Trauma Surg ; 138(12): 1653-1657, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30094560

RESUMEN

INTRODUCTION: Osteoporosis and decreased bone density are known to increase fracture incidence and severity. Although much is known regarding the effects of bone density on fracture risk and the treatment options for prevention of fragility fractures, whether bone quality alters clinical outcomes after fracture fixation is unknown. The purpose of this study was to determine whether bone quality correlates with clinical outcomes after fracture fixation. MATERIALS AND METHODS: A prospective database of all operatively treated ankle fractures by a single surgeon from 2003 to 2013 was used to identify patients. All patients included in the study had preoperative computed tomography (CT) imaging of the injured ankle and postoperative CT imaging of the contralateral ankle. Hounsfield unit (HU) measurement values were determined by placing an elliptical region of interest confined to the cancellous metaphyseal region of the distal tibia and fibula. The primary and secondary clinical outcomes included Foot and Ankle Outcome Scores (FAOS) and ankle range of motion (ROM). Included patients had at least 12 months of clinical outcome data. RESULTS: Sixty-four patients met the inclusion criteria. Comparison of HU values from the injured and contralateral side demonstrated almost perfect agreement (ICC(2,1) = 0.938), suggesting that HU values can be accurately measured in the setting of a fracture. Increased HU values of the injured distal tibia and fibula significantly correlated with improved outcomes in four of five FAOS domains, including pain, activities of daily living, sports, and quality of life (beta = 0.285-0.344; P ≤ 0.05 for all). Range of motion outcomes did not significantly correlate with HU values. CONCLUSIONS: Our results suggest that decreased bone quality, as measured using preoperative CT, significantly correlates with inferior short-term clinical outcomes. These results have significant implications for integrating bone quality into treatment algorithms for fracture patients.


Asunto(s)
Fracturas de Tobillo/cirugía , Articulación del Tobillo/fisiopatología , Densidad Ósea/fisiología , Fijación Interna de Fracturas/métodos , Osteoporosis/complicaciones , Absorciometría de Fotón/métodos , Actividades Cotidianas , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Articulación del Tobillo/diagnóstico por imagen , Articulación del Tobillo/cirugía , Femenino , Peroné/diagnóstico por imagen , Fijación Interna de Fracturas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Calidad de Vida , Rango del Movimiento Articular/fisiología , Estudios Retrospectivos , Tibia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento , Adulto Joven
19.
Artículo en Inglés | MEDLINE | ID: mdl-29611845

RESUMEN

As the operative management of displaced distal radius fractures evolves, intraoperative techniques and fixation strategies evolve as well. Achieving and maintaining an acceptable reduction is paramount but can be difficult with particular fracture patterns. In this article, we describe the use of a radial column plate as a reduction tool in the management of unstable distal radius fractures, along with clinical and radiographic clinical outcomes. This technique can be useful in situations where multiplanar instability exists, or simply when intraoperative assistance is limited. Surgeons can expect acceptable radiographic and clinical outcomes when using this technique, although effects on scar formation and wrist range of motion are currently not known.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/métodos , Fracturas del Radio/cirugía , Radio (Anatomía)/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fijación Interna de Fracturas/instrumentación , Humanos , Fracturas Intraarticulares/cirugía , Masculino , Persona de Mediana Edad , Articulación de la Muñeca/cirugía
20.
J Orthop Trauma ; 32(3): 141-147, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29065035

RESUMEN

OBJECTIVE: To determine if ligamentous and meniscal injuries as determined by initial magnetic resonance imaging altered clinical outcomes after the fixation of tibial plateau fractures. DESIGN: Comparative cohort study. SETTING: Academic level I trauma center. PATIENTS/PARTICIPANTS: Eighty-two patients from a prospective database of operatively treated tibial plateau fractures met the inclusion criteria, which consisted of injury radiographs, preoperative knee magnetic resonance imaging (MRI), and a minimum of 12 months of clinical outcomes. INTERVENTION: In addition to radiographs and computed tomography scans for fracture assessment, an MRI was performed to detect tears in the medial and lateral menisci and complete ruptures of the cruciate ligaments (anterior cruciate ligament and posterior cruciate ligament) and collateral ligaments [lateral collateral ligament and medial collateral ligament (MCL)]. Surgical fixation of tibial plateau fractures was performed by a single surgeon based on injury patterns. MAIN OUTCOME MEASUREMENTS: Clinical outcomes included the Knee Outcome Survey Activities of Daily Living Scale, the Lower Extremity Functional Scale, the Short-Form 36, and knee range of motion. Secondary soft tissue surgeries and conversion to arthroplasty were also noted. RESULTS: On injury MRI, 60 patients (73%) had injuries to at least one soft tissue structure. At final follow-up, 2 patients (2%) had a secondary soft tissue surgery and 1 patient (1%) underwent total knee arthroplasty. Patient-reported outcomes and range of motion assessments were not significantly different in patients with and without medial meniscal tears, lateral meniscal tears, and complete MCL ruptures. CONCLUSIONS: In this cohort of patients with operative tibial plateau fractures, sutured lateral meniscal tears, untreated medial meniscus tears, and complete MCL ruptures did not significantly affect clinical outcomes. In addition, these data suggest that obtaining a preoperative MRI in patients with tibial plateau fractures to diagnose soft tissue injuries may not alter the surgical treatment or alter patient prognosis for midterm outcomes. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Traumatismos de la Rodilla/diagnóstico por imagen , Ligamentos Articulares/diagnóstico por imagen , Ligamentos Articulares/lesiones , Traumatismos de los Tejidos Blandos/cirugía , Fracturas de la Tibia/cirugía , Lesiones de Menisco Tibial/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Traumatismos de la Rodilla/complicaciones , Traumatismos de la Rodilla/cirugía , Ligamentos Articulares/cirugía , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Traumatismos de los Tejidos Blandos/complicaciones , Traumatismos de los Tejidos Blandos/diagnóstico por imagen , Fracturas de la Tibia/complicaciones , Fracturas de la Tibia/diagnóstico por imagen , Lesiones de Menisco Tibial/cirugía , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA