Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 18 de 18
1.
Mol Imaging Biol ; 22(5): 1342-1352, 2020 10.
Article En | MEDLINE | ID: mdl-32602084

PURPOSE: Physiological motion and partial volume effect (PVE) significantly degrade the quality of cardiac positron emission tomography (PET) images in the fast-beating hearts of rodents. Several Super-resolution (SR) techniques using a priori anatomical information have been proposed to correct motion and PVE in PET images. Ultrasound is ideally suited to capture real-time high-resolution cine images of rodent hearts. Here, we evaluated an ultrasound-based SR method using simultaneously acquired and co-registered PET-CT-Ultrafast Ultrasound Imaging (UUI) of the beating heart in closed-chest rodents. PROCEDURES: The method was tested with numerical and animal data (n = 2) acquired with the non-invasive hybrid imaging system PETRUS that acquires simultaneously PET, CT, and UUI. RESULTS: We showed that ultrasound-based SR drastically enhances the quality of PET images of the beating rodent heart. For the simulations, the deviations between expected and mean reconstructed values were 2 % after applying SR. For the experimental data, when using Ultrasound-based SR correction, contrast was improved by a factor of two, signal-to-noise ratio by 11 %, and spatial resolution by 56 % (~ 0.88 mm) with respect to static PET. As a consequence, the metabolic defect following an acute cardiac ischemia was delineated with much higher anatomical precision. CONCLUSIONS: Our results provided a proof-of-concept that image quality of cardiac PET in fast-beating rodent hearts can be significantly improved by ultrasound-based SR, a portable low-cost technique. Improved PET imaging of the rodent heart may allow new explorations of physiological and pathological situations related with cardiac metabolism.


Heart/diagnostic imaging , Positron-Emission Tomography , Ultrasonography , Algorithms , Animals , Coronary Vessels/diagnostic imaging , Female , Ligation , Numerical Analysis, Computer-Assisted , Phantoms, Imaging , Rats, Wistar
2.
Theranostics ; 10(8): 3518-3532, 2020.
Article En | MEDLINE | ID: mdl-32206105

Rationale: Deregulation of metabolism and induction of vascularization are major hallmarks of cancer. Using a new multimodal preclinical imaging instrument, we explored a sequence of events leading to sunitinib-induced resistance in a murine model of paraganglioma (PGL) invalidated for the expression of succinate dehydrogenase subunit B (Sdhb-/-). Methods: Two groups of Sdhb-/- tumors bearing mice were treated with sunitinib (6 weeks) or vehicle (3 weeks). Concurrent Positron Emission Tomography (PET) with 2' -deoxy-2'-[18F]fluoro-D-glucose (FDG), Computed Tomography (CT) and Ultrafast Ultrasound Imaging (UUI) imaging sessions were performed once a week and ex vivo samples were analyzed by western blots and histology. Results: PET-CT-UUI enabled to detect a rapid growth of Sdhb-/- tumors with increased glycolysis and vascular development. Sunitinib treatment prevented tumor growth, vessel development and reduced FDG uptake at week 1 and 2 (W1-2). Thereafter, imaging revealed tumor escape from sunitinib treatment: FDG uptake in tumors increased at W3, followed by tumor growth and vessel development at W4-5. Perfused vessels were preferentially distributed in the hypermetabolic regions of the tumors and the perfused volume increased during escape from sunitinib treatment. Finally, initial changes in total lesion glycolysis and maximum vessel length at W1 were predictive of resistance to sunitinib. Conclusion: These results demonstrate an adaptive resistance of Sdhb-/- tumors to six weeks of sunitinib treatment. Early metabolic changes and delayed vessel architecture changes were detectable and predictable in vivo early during anti-angiogenic treatment. Simultaneous metabolic, anatomical and functional imaging can monitor precisely the effects of anti-angiogenic treatment of tumors.


Antineoplastic Agents/therapeutic use , Neovascularization, Pathologic/diagnostic imaging , Paraganglioma/diagnostic imaging , Sunitinib/therapeutic use , Animals , Disease Models, Animal , Drug Resistance, Neoplasm , Female , Glucose-6-Phosphate/analogs & derivatives , Glycolysis , Mice , Mice, Nude , Neovascularization, Pathologic/metabolism , Neovascularization, Pathologic/prevention & control , Paraganglioma/drug therapy , Paraganglioma/metabolism , Paraganglioma/pathology , Positron-Emission Tomography , Tomography, X-Ray Computed , Tumor Escape/drug effects , Ultrasonography
3.
J Biomed Opt ; 24(10): 1-12, 2019 10.
Article En | MEDLINE | ID: mdl-31646840

Multiphoton microscopy (MPM) has the capacity to record second-harmonic generation (SHG) and endogenous two-photon excitation fluorescence (2PEF) signals emitted from biological tissues. The development of fiber-based miniaturized endomicroscopes delivering pulses in the femtosecond range will allow the transfer of MPM to clinical endoscopy. We present real-time SHG and 2PEF ex vivo images using an endomicroscope, which totally complies with clinical endoscopy regulations. This system is based on the proximal scanning of a commercial multicore image guide (IG). For understanding the inhomogeneities of the recorded images, we quantitatively characterize the IG at the single-core level during nonlinear excitation. The obtained results suggest that these inhomogeneities originate from the variable core geometries that, therefore, exhibit variable nonlinear and dispersive properties. Finally, we propose a method based on modulation of dispersion precompensation to address the image inhomogeneity issue and, as a proof of concept, we demonstrate its capability to improve the nonlinear image quality.


Endoscopy/instrumentation , Microscopy, Fluorescence, Multiphoton/instrumentation , Signal Processing, Computer-Assisted/instrumentation , Equipment Design , Humans , Image Processing, Computer-Assisted , Lung/diagnostic imaging , Optical Fibers , Photons
4.
Phys Med Biol ; 63(19): 19NT01, 2018 09 21.
Article En | MEDLINE | ID: mdl-30091723

We recently introduced a hybrid imaging instrument, PETRUS, based on a combination of positron emission tomography (PET) for molecular imaging, x-ray computed tomography (CT) for anatomical imaging, co-registration and attenuation correction, and ultrafast ultrasound imaging (UUI) for motion-correction, hemodynamic and biomechanical imaging. In order to ensure a precise co-registration of simultaneous PET-UUI acquisitions, ultrasound probes attached to an ultrafast ultrasound scanner are operated in the field of view (FOV) of a small animal PET/CT scanner using a remote-controlled micro-positioner. Here we explore the effect of the presence of ultrasound probes on PET image quality. We compare the performance of PET and image quality with and without the presence of probes in the PET field of view, both in vitro following the NEMA-NU-4-2008 standard protocol, and in vivo in small animals. Overall, deviations in the quality of images acquired with and without the ultrasound probes were under 10% and under 7% for the NEMA protocol and in vivo tests, respectively. Our results demonstrate the capability of the PETRUS device to acquire multimodal images in vivo without significant degradation of image quality.


Multimodal Imaging/methods , Positron Emission Tomography Computed Tomography/methods , Ultrasonography/methods , Animals , Humans , Image Processing, Computer-Assisted/methods , Multimodal Imaging/instrumentation , Multimodal Imaging/standards , Patient Positioning , Phantoms, Imaging , Positron Emission Tomography Computed Tomography/instrumentation , Positron Emission Tomography Computed Tomography/standards , Ultrasonography/instrumentation , Ultrasonography/standards
5.
Phys Med Biol ; 63(3): 03NT03, 2018 02 06.
Article En | MEDLINE | ID: mdl-29311418

As programmable ultrasound scanners become more common in research laboratories, it is increasingly important to develop robust software-based image formation algorithms that can be obtained in a straightforward fashion for different types of probes and sequences with a small risk of error during implementation. In this work, we argue that as the computational power keeps increasing, it is becoming practical to directly implement an approximation to the matrix operator linking reflector point targets to the corresponding radiofrequency signals via thoroughly validated and widely available simulations software. Once such a spatiotemporal forward-problem matrix is constructed, standard and thus highly optimized inversion procedures can be leveraged to achieve very high quality images in real time. Specifically, we show that spatiotemporal matrix image formation produces images of similar or enhanced quality when compared against standard delay-and-sum approaches in phantoms and in vivo, and show that this approach can be used to form images even when using non-conventional probe designs for which adapted image formation algorithms are not readily available.


Algorithms , Carotid Arteries/diagnostic imaging , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Software , Ultrasonography/methods , Humans
6.
Nat Biomed Eng ; 2(2): 85-94, 2018 02.
Article En | MEDLINE | ID: mdl-31015628

Positron emission tomography-computed tomography (PET-CT) is the most sensitive molecular imaging modality, but it does not easily allow for rapid temporal acquisition. Ultrafast ultrasound imaging (UUI)-a recently introduced technology based on ultrasonic holography-leverages frame rates of up to several thousand images per second to quantitatively map, at high resolution, haemodynamic, biomechanical, electrophysiological and structural parameters. Here, we describe a pre-clinical scanner that registers PET-CT and UUI volumes acquired simultaneously and offers multiple combinations for imaging. We demonstrate that PET-CT-UUI allows for simultaneous images of the vasculature and metabolism during tumour growth in mice and rats, as well as for synchronized multi-modal cardiac cine-loops. Combined anatomical, functional and molecular imaging with PET-CT-UUI represents a high-performance and clinically translatable technology for biomedical research.


Neoplasms/pathology , Positron Emission Tomography Computed Tomography , Ultrasonography , Animals , Cell Line, Tumor , Cricetinae , Female , Glucose/metabolism , Heart/anatomy & histology , Heart/diagnostic imaging , Mice , Myocardium/metabolism , Neoplasms/diagnostic imaging , Phenotype , Rats , Rats, Wistar
7.
Integr Cancer Ther ; 15(4): 512-524, 2016 12.
Article En | MEDLINE | ID: mdl-27130721

Background Ursolic acid (UA) is a triterpene found in different plant species, possessing antitumor activity, which may be a result of its antiangiogenic effect. However, UA has low water solubility, which limits its use because the bioavailability is impaired. To overcome this inconvenience, we developed long-circulating and pH-sensitive liposomes containing ursolic acid (SpHL-UA). We investigated the antiangiogenic effect of free UA and SpHL-UA in murine brain cancer and human breast tumor models by means of determination of the relative tumor volume, dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), and histopathological analysis. Methods The animals were treated with dimethyl sulfoxide in 0.9% (w/v) NaCl, free UA, long-circulating and pH-sensitive liposomes without drug (SpHL), or SpHL-UA. The animals were submitted to each treatment by intraperitoneal injection for 5 days. The dose of free UA or SpHL-UA was equal to 23 mg/kg. Results Tumor growth inhibition was not observed in human breast tumor-bearing animals. For murine gliosarcoma-bearing animals, a slight tumor growth inhibition was observed in the groups treated with free UA or SpHL-UA (9% and 15%, respectively). No significant change in any of the parameters evaluated by DCE-MRI for both experimental models could be observed. Nevertheless, the evaluation of the mean values of magnetic resonance parameters of human breast tumor-bearing animals showed evidence of a possible antiangiogenic effect induced by SpHL-UA. Histopathological analysis did not present significant change for any treatment. Conclusion SpHL-UA did not show antiangiogenic activity in a gliosarcoma model and seemed to induce an antiangiogenic effect in the human breast tumor model.


Antineoplastic Agents/pharmacology , Breast Neoplasms/drug therapy , Gliosarcoma/drug therapy , Liposomes/administration & dosage , Mammary Neoplasms, Animal/drug therapy , Triterpenes/pharmacology , Animals , Cell Line, Tumor , Disease Models, Animal , Female , Humans , Hydrogen-Ion Concentration , MCF-7 Cells , Mice , Mice, Nude , Rats , Ursolic Acid
8.
PLoS One ; 9(1): e87002, 2014.
Article En | MEDLINE | ID: mdl-24489826

BACKGROUND: Cell-SELEX is now widely used for the selection of aptamers against cell surface biomarkers. However, despite negative selection steps using mock cells, this method sometimes results in aptamers against undesirable targets that are expressed both on mock and targeted cells. Studying these junk aptamers might be useful for further applications than those originally envisaged. METHODOLOGY/PRINCIPAL FINDINGS: Cell-SELEX was performed to identify aptamers against CHO-K1 cells expressing human Endothelin type B receptor (ETBR). CHO-K1 cells were used for negative selection of aptamers. Several aptamers were identified but no one could discriminate between both cell lines. We decided to study one of these aptamers, named ACE4, and we identified that it binds to the Annexin A2, a protein overexpressed in many cancers. Radioactive binding assays and flow cytometry demonstrated that the aptamer was able to bind several cancer cell lines from different origins, particularly the MCF-7 cells. Fluorescence microscopy revealed it could be completely internalized in cells in 2 hours. Finally, the tumor targeting of the aptamer was evaluated in vivo in nude mice xenograft with MCF-7 cells using fluorescence diffuse optical tomography (fDOT) imaging. Three hours after intravenous injection, the aptamer demonstrated a significantly higher uptake in the tumor compared to a scramble sequence. CONCLUSIONS/SIGNIFICANCE: Although aptamers could be selected during cell-SELEX against other targets than those initially intended, they represent a potential source of ligands for basic research, diagnoses and therapy. Here, studying such aptamers, we identify one with high affinity for Annexin A2 that could be a promising tool for biomedical application.


Adenocarcinoma/diagnosis , Annexin A2/metabolism , Aptamers, Nucleotide , Breast Neoplasms/diagnosis , Neoplasm Proteins/metabolism , Adenocarcinoma/genetics , Animals , Annexin A2/genetics , Aptamers, Nucleotide/genetics , Aptamers, Nucleotide/isolation & purification , Breast Neoplasms/genetics , CHO Cells , Cricetulus , Endocytosis , Female , Flow Cytometry , Gene Expression , Humans , Incidental Findings , Ligands , MCF-7 Cells , Mice , Mice, Nude , Neoplasm Proteins/genetics , Neoplasm Transplantation , Protein Binding , Receptor, Endothelin B/genetics , Receptor, Endothelin B/metabolism , SELEX Aptamer Technique
9.
Mol Imaging Biol ; 15(3): 316-25, 2013 Jun.
Article En | MEDLINE | ID: mdl-22927057

PURPOSE: Given the progress of fluorescence diffuse optical tomography (fDOT) technology, here, we study the additional benefits provided by multimodal PET/fDOT imaging by comparing the biodistribution of 2-deoxy-2-[(18)F]fluoro-D-glucose ([(18)F]FDG) in tumors with three fluorescent probes: a glucose analog, a protease activatable optical probe, and a ligand of αvß3 integrin. PROCEDURES: Sequential fDOT/PET/computed tomography (CT) imaging of mice was performed with a custom multimodal mouse support that allows the subject to be transferred between the fDOT and the PET/CT scanners. Experiments were performed in xenografted tumor models derived from the human breast cancer line MDA-MB 231 and compared to ex vivo analysis. RESULTS: The three-dimensional signals showed that the fluorescent glucose analog is not colocalized with [(18)F]FDG, raising questions about its use as a surrogate probe of the PET tracer. Fusion of [(18)F]FDG with the other fluorescent probes showed evidence of high variability both for the protease activity and the αvß3 integrin expression during tumor growth. CONCLUSION: The added value of hybrid PET/fDOT over the two modalities was demonstrated for cross-validation of probes and for better characterization of tumor models.


Fluorescent Dyes , Fluorodeoxyglucose F18 , Neoplasms/diagnostic imaging , Positron-Emission Tomography/methods , Tomography, Optical/methods , Animals , Cathepsins/metabolism , Cell Line, Tumor , Diffusion , Humans , Mice , Molecular Probes , Neoplasms/metabolism , Neoplasms/pathology , Oligopeptides , Reproducibility of Results , Tissue Distribution
10.
EJNMMI Res ; 2(1): 19, 2012 May 07.
Article En | MEDLINE | ID: mdl-22564761

BACKGROUND: Bimodal molecular imaging with fluorescence diffuse optical tomography (fDOT) and positron emission tomography (PET) has the capacity to provide multiple molecular information of mouse tumors. The objective of the present study is to co-register fDOT and PET molecular images of tumors in mice automatically. METHODS: The coordinates of bimodal fiducial markers (FM) in regions of detection were automatically detected in planar optical images (x, y positions) in laser pattern optical surface images (z position) and in 3-D PET images. A transformation matrix was calculated from the coordinates of the FM in fDOT and in PET and applied in order to co-register images of mice bearing neuroendocrine tumors. RESULTS: The method yielded accurate non-supervised co-registration of fDOT and PET images. The mean fiducial registration error was smaller than the respective voxel sizes for both modalities, allowing comparison of the distribution of contrast agents from both modalities in mice. Combined imaging depicting tumor metabolism with PET-[18 F]2-deoxy-2-fluoro-d-glucose and blood pool with fDOT demonstrated partial overlap of the two signals. CONCLUSIONS: This automatic method for co-registration of fDOT with PET and other modalities is efficient, simple and rapid, opening up multiplexing capacities for experimental in vivo molecular imaging.

11.
Mol Imaging ; 11(1): 22-6, 2012 Feb.
Article En | MEDLINE | ID: mdl-22418024

There is controversy over whether matrix metalloproteinases (MMPs) are activated during the early therapeutic window following ischemic stroke. Ex vivo, an increase was reported as early as 4 hours, whereas in vivo, no increase was found until 24 hours postischemia. We used fluorescence diffuse optical tomography to image MMP activity following experimental cerebral ischemia; increased MMP activity was observed in the ischemic area as early as 3 to 6 hours after ischemic onset and correlated with the volume of ischemic cerebral tissue. Therefore, MMP activation is an immediate early response to cerebral ischemia concurrent with the therapeutic window.


Brain Ischemia/enzymology , Matrix Metalloproteinases/metabolism , Animals , Brain/enzymology , Brain/pathology , Brain Ischemia/pathology , Male , Mice , Mice, Inbred C57BL , Tomography, X-Ray Computed
12.
Small ; 7(19): 2786-92, 2011 Oct 04.
Article En | MEDLINE | ID: mdl-21837631

In vivo tumor targeting and drug delivery properties of small polymerized polydiacetylene (PDA) micelles (∼10 nm) is investigated in a murine MDA-MB-231 xenograft model of breast cancer. Three micelles with different surface coatings are synthesized and tested for their ability to passively target tumor through the enhanced permeability and retention effect. After injection (24 h), fluorescence diffuse optical tomographic imaging indicates a tumor uptake of nearly 3% of the injected dose for the micelles with a 2 kDa poly(ethylene glycol) (PEG)-coating (PDA-PEG2000). The uptake of PDA micelles in tumors is confirmed by co-localization with [(18) F]-fluorodeoxyglucose (FDG) positron emission tomography. Although FDG has a higher diffusion rate in tumors, 40 ± 19% of the retained micelles is co-registered with the tumor volume visualized by FDG. Finally, PDA-PEG2000 micelles are loaded with the hydrophobic anticancer drug paclitaxel and used in vivo to inhibit tumor growth. These findings demonstrate the potential of PDA-PEG2000 micelles for both in vivo tumor imaging and drug delivery applications.


Diagnostic Imaging , Drug Delivery Systems/methods , Micelles , Neoplasms/metabolism , Polymers/chemistry , Polyynes/chemistry , Animals , Body Weight/drug effects , Cell Death/drug effects , Cell Line, Tumor , Humans , Injections, Intravenous , Mice , Neoplasms/diagnostic imaging , Neoplasms/pathology , Paclitaxel/pharmacology , Polyacetylene Polymer , Polymers/administration & dosage , Polymers/pharmacokinetics , Polyynes/administration & dosage , Polyynes/pharmacokinetics , Positron-Emission Tomography , Spectroscopy, Near-Infrared , Tissue Distribution/drug effects , Tumor Burden/drug effects , Xenograft Model Antitumor Assays
13.
Opt Lett ; 35(18): 3024-6, 2010 Sep 15.
Article En | MEDLINE | ID: mdl-20847766

The performance of small animal photonic imaging has been considerably improved since the development of fluorescence diffuse optical tomography (fDOT), which can reconstruct fluorescent probe distribution inside tissue. However, the quantification capabilities of this new technology are still a topic of debate, especially in comparison to classical nuclear imaging techniques. Here, we present a method to in vivo calibrate the quantity and localization of a probe provided by free-space fDOT (where no plate is compressing the mouse) with positron emission tomography (PET) and x-ray computed tomography, respectively. This methodology allowed us to demonstrate a strong linear correlation (R(2)=0.95) between fDOT and PET for probe concentrations ranging from 3 nM to 1 µM in a deep-seated organ.


Positron-Emission Tomography , Tomography, Optical/methods , Animals , Image Processing, Computer-Assisted , Kidney/diagnostic imaging , Mice
14.
Opt Express ; 17(18): 16266-80, 2009 Aug 31.
Article En | MEDLINE | ID: mdl-19724626

Noncontact optical imaging has attracted increasing attention in recent years due to its significant advantages on detection sensitivity, spatial resolution, image quality and system simplicity compared with contact measurement. However, photon transport simulation in free-space is still an extremely challenging topic for the complexity of the optical system. For this purpose, this paper proposes an analytical model for photon propagation in free-space based on hybrid radiosity-radiance theorem (HRRT). It combines Lambert's cosine law and the radiance theorem to handle the influence of the complicated lens and to simplify the photon transport process in the optical system. The performance of the proposed model is evaluated and validated with numerical simulations and physical experiments. Qualitative comparison results of flux distribution at the detector are presented. In particular, error analysis demonstrates the feasibility and potential of the proposed model for simulating photon propagation in free-space.

15.
J Cell Mol Med ; 13(9B): 4002-13, 2009 Sep.
Article En | MEDLINE | ID: mdl-19426156

The present study aims at investigating the mechanism by which membrane-type 4 matrix metalloproteinase (MT4-MMP), a membrane-anchored MMP expressed by human breast tumour cells promotes the metastatic dissemination into lung. We applied experimental (intravenous) and spontaneous (subcutaneous) models of lung metastasis using human breast adenocarcinoma MDA-MB-231 cells overexpressing or not MT4-MMP. We found that MT4-MMP does not affect lymph node colonization nor extravasation of cells from the bloodstream, but increases the intravasation step leading to metastasis. Ultrastructural and fluorescent microscopic observations coupled with automatic computer-assisted quantifications revealed that MT4-MMP expression induces blood vessel enlargement and promotes the detachment of mural cells from the vascular tree, thus causing an increased tumour vascular leak. On this basis, we propose that MT4-MMP promotes lung metastasis by disturbing the tumour vessel integrity and thereby facilitating tumour cell intravasation.


Breast Neoplasms/enzymology , Lung Neoplasms/enzymology , Matrix Metalloproteinase 17/metabolism , Animals , Breast Neoplasms/blood supply , Breast Neoplasms/pathology , Cell Line, Tumor , Humans , Lung Neoplasms/secondary , Lymphatic Metastasis , Mammary Neoplasms, Animal/blood supply , Mammary Neoplasms, Animal/enzymology , Mammary Neoplasms, Animal/pathology , Mice , Mice, Nude , Microscopy, Electron, Transmission/methods , Microscopy, Fluorescence/methods , Neoplasm Transplantation , Neovascularization, Pathologic , Pericytes/metabolism
16.
Mol Imaging ; 7(4): 157-67, 2008.
Article En | MEDLINE | ID: mdl-19123986

Stroke induces a strong inflammatory reaction in the brain and depresses the immune system. We sought to assess longitudinal changes in T-cell numbers in the lymphoid organs of living mice after brain ischemia. Middle cerebral artery occlusion was carried out in transgenic mice expressing green fluorescent protein (GFP+) in the T-cell population under the control of the hCD2 locus control region. Imaging was performed by three-dimensional fluorescence molecular tomography (FMT) before and at several time points after ischemia or sham operation and in controls. At day 7, GFP+ cell content in lymphoid organs was measured postmortem by flow cytometry. GFP+ cell numbers and in vivo FMT signal intensity were reduced at day 7 after ischemia and, to a lesser extent, after sham operation. Linear regression analysis demonstrated that postmortem GFP+ cell numbers and corresponding in vivo FMT data were significantly correlated in the thymus (r2 = .65, p < .0001) and lymph nodes (r2 = .67, p < .0001). These relationships allowed inferring the number of GFP+ T cells from in vivo FMT data. The results show the time course reduction of T-cell content in the lymphoid organs of living mice, providing in vivo evidence of lymphoid organ atrophy after stroke and, to a lesser extent, after head surgery with craniectomy and dura mater opening in sham-operated mice.


Brain Ischemia/pathology , Imaging, Three-Dimensional/methods , Lymph Nodes/pathology , T-Lymphocytes , Thymus Gland/pathology , Tomography/methods , Analysis of Variance , Animals , Brain Ischemia/immunology , Disease Models, Animal , Female , Fluorescence , Green Fluorescent Proteins/metabolism , Linear Models , Lymph Nodes/immunology , Lymph Nodes/metabolism , Lymphocyte Count , Male , Mice , Mice, Transgenic , T-Lymphocytes/metabolism , Thymus Gland/immunology , Thymus Gland/metabolism
17.
Appl Opt ; 46(17): 3617-27, 2007 Jun 10.
Article En | MEDLINE | ID: mdl-17514324

During the past decade, optical imaging combined with tomographic approaches has proved its potential in offering quantitative three-dimensional spatial maps of chromophore or fluorophore concentration in vivo. Due to its direct application in biology and biomedicine, diffuse optical tomography (DOT) and its fluorescence counterpart, fluorescence molecular tomography (FMT), have benefited from an increase in devoted research and new experimental and theoretical developments, giving rise to a new imaging modality. The most recent advances in FMT and DOT are based on the capability of collecting large data sets by using CCDs as detectors, and on the ability to include multiple projections through recently developed noncontact approaches. For these to be implemented, we have developed an imaging setup that enables three-dimensional imaging of arbitrary shapes in fluorescence or absorption mode that is appropriate for small animal imaging. This is achieved by implementing a noncontact approach both for sources and detectors and coregistering surface geometry measurements using the same CCD camera. A thresholded shadowgrammetry approach is applied to the geometry measurements to retrieve the surface mesh. We present the evaluation of the system and method in recovering three-dimensional surfaces from phantom data and live mice. The approach is used to map the measured in vivo fluorescence data onto the tissue surface by making use of the free-space propagation equations, as well as to reconstruct fluorescence concentrations inside highly scattering tissuelike phantom samples. Finally, the potential use of this setup for in vivo small animal imaging and its impact on biomedical research is discussed.


Diagnostic Imaging/methods , Image Processing, Computer-Assisted/methods , Optics and Photonics , Tomography, Optical/instrumentation , Algorithms , Animals , Calibration , Equipment Design , Green Fluorescent Proteins/chemistry , Imaging, Three-Dimensional , Mice , Microscopy, Fluorescence/instrumentation , Microscopy, Fluorescence/methods , Models, Statistical , Phantoms, Imaging , Surface Properties , Tomography, Optical/methods
18.
Mol Imaging ; 6(2): 96-107, 2007.
Article En | MEDLINE | ID: mdl-17445504

Given that optical tomography is capable of quantitatively imaging the distribution of several important chromophores and fluorophores in vivo, there has been a great deal of interest in developing optical imaging systems with increased numbers of measurements under optimal experimental conditions. In this article, we present a novel system that enables three-dimensional imaging of fluorescent probes in whole animals using a noncontact setup, in parallel with a three-dimensional surface reconstruction algorithm. This approach is directed toward the in vivo imaging of fluorophore or fluorescent protein concentration in small animals. The system consists of a rotating sample holder and a lens-coupled charge-coupled device camera in combination with a fiber-coupled laser scanning device. By measuring multiple projections, large data sets can be obtained, thus improving the accuracy of the inversion models used for quantitative three-dimensional reconstruction of fluorochrome distribution, as well as facilitating a higher spatial resolution. In this study, the system was applied to determining the distribution of green fluorescent protein (GFP)-expressing T lymphocytes in a transgenic mouse model, thus demonstrating the potential of the system for studying immune system function. The technique was used to image and reconstruct fluorescence originating from 32 x 10(6) T cells in the thymus and 3 x 10(5) T cells in the spleen.


Fluorescent Dyes/analysis , Green Fluorescent Proteins/analysis , Imaging, Three-Dimensional/methods , T-Lymphocytes/chemistry , Tomography/methods , Whole Body Imaging/methods , Animals , Flow Cytometry , Fluorescent Dyes/metabolism , Green Fluorescent Proteins/metabolism , Imaging, Three-Dimensional/instrumentation , Mice , Mice, Transgenic , T-Lymphocytes/immunology , Tomography/instrumentation , Whole Body Imaging/instrumentation
...