Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 107
1.
ACS Appl Mater Interfaces ; 16(19): 24748-24759, 2024 May 15.
Article En | MEDLINE | ID: mdl-38690838

In the past decade, perovskite solar cell (PSC) photoelectric conversion efficiency has advanced significantly, and tin dioxide (SnO2) has been extensively used as the electron transport layer (ETL). Due to its high electron mobility, strong chemical stability, energy level matching with perovskite, and easy low-temperature fabrication, SnO2 is one of the most effective ETL materials. However, the SnO2 material as an ETL has its limitations. For example, SnO2 films prepared by low-temperature spin-coating contain a large number of oxygen vacancies, resulting in energy loss and high open-circuit voltage (VOC) loss. In addition, the crystal quality of perovskites is closely related to the substrate, and the disordered crystal orientation will lead to ion migration, resulting in a large number of uncoordinated Pb2+ defects. Therefore, interface optimization is essential to improve the efficiency and stability of the PSC. In this work, 2-(5-chloro-2-benzotriazolyl)-6-tert-butyl-p-cresol (CBTBC) was introduced for ETL modification. On the one hand, the hydroxyl group of CBTBC forms a Lewis mixture with the Sn atom, which reduces the oxygen vacancy defect and prevents nonradiative recombination. On the other hand, the SnO2/CBTBC interface can effectively improve the crystal orientation of perovskite by influencing the crystallization kinetics of perovskite, and the nitrogen element in CBTBC can effectively passivate the uncoordinated Pb2+ defects at the SnO2/perovskite interface. Finally, the prevailing PCE of PSC (1.68 eV) modified by CBTBC was 20.34% (VOC = 1.214 V, JSC = 20.49 mA/cm2, FF = 82.49%).

2.
Adv Sci (Weinh) ; : e2401345, 2024 Apr 22.
Article En | MEDLINE | ID: mdl-38647436

The development of semiconducting polymers with good processability in green solvents and competitive electrical performance is essential for realizing sustainable large-scale manufacturing and commercialization of organic electronics. A major obstacle is the processability-performance dichotomy that is dictated by the lack of ideal building blocks with balanced polarity, solubility, electronic structures, and molecular conformation. Herein, through the integration of donor, quinoid and acceptor units, an unprecedented building block, namely TQBT, is introduced for constructing a serial of conjugated polymers. The TQBT, distinct in non-symmetric structure and high dipole moment, imparts enhanced solubility in anisole-a green solvent-to the polymer TQBT-T. Furthermore, PTQBT-T possess a highly rigid and planar backbone owing to the nearly coplanar geometry and quinoidal nature of TQBT, resulting in strong aggregation in solution and localized aggregates in film. Remarkably, PTQBT-T films spuncast from anisole exhibit a hole mobility of 2.30 cm2 V-1 s-1, which is record high for green solvent-processable semiconducting polymers via spin-coating, together with commendable operational and storage stability. The hybrid building block emerges as a pioneering electroactive unit, shedding light on future design strategies in high-performance semiconducting polymers compatible with green processing and marking a significant stride towards ecofriendly organic electronics.

3.
Article En | MEDLINE | ID: mdl-38666348

While hydrometallurgy is the primary technology for recycling spent lithium-ion batteries due to various advantages, it still involves substantial consumption of chemical reagents and poses challenges in wastewater emission. Herein, we report the realization of cathode recycling under lean-leachate conditions by dynamically stabilizing hole-mediated diffusion kinetics, which is enabled by synchronizing the extraction step during the leaching stage, thus continuously removing the dissolved ions out of the leachate. Theoretical molecular dynamics simulations predict that preventing the accumulation of the dissolved ions is efficient for keeping the leaching process proceeding. Experimentally, even with a small dosage of leachate (0.5 mL), a 94.51% leaching efficiency can be achieved (90 °C, 40 min) for spent LNO materials. Considering that our strategy is not limited to a specific materials system, it could be extended to recycle other valuable materials (including LCO or NCM 811) with minimal leachate usage.

4.
Mater Horiz ; 11(9): 2106-2114, 2024 05 07.
Article En | MEDLINE | ID: mdl-38545857

Artificial afferent neurons in the sensory nervous system inspired by biology have enormous potential for efficiently perceiving and processing environmental information. However, the previously reported artificial afferent neurons suffer from two prominent challenges: considerable power consumption and limited scalability efficiency. Herein, addressing these challenges, a bioinspired artificial thermal afferent neuron based on a N-doped SiTe ovonic threshold switching (OTS) device is presented for the first time. The engineered OTS device shows remarkable uniformity and robust endurance, ensuring the reliability and efficacy of the artificial afferent neurons. A substantially decreased leakage current of the SiTe OTS device by nitrogen doping results in ultra-low power consumption less than 0.3 nJ per spike for artificial afferent neurons. The inherent temperature response exhibited by N-doped SiTe OTS materials allows us to construct a highly compact artificial thermal afferent neuron over a wide temperature range. An edge detection task is performed to further verify its thermal perceptual computing function. Our work provides an insight into OTS-based artificial afferent neurons for electronic skin and sensory neurorobotics.


Neurons, Afferent , Neurons, Afferent/physiology , Temperature , Humans
5.
Environ Res ; 251(Pt 1): 118566, 2024 Mar 04.
Article En | MEDLINE | ID: mdl-38447606

Both g-C3N4 and Bi2O2CO3 are good photocatalysts for the removal of antibiotic pollutants, but their morphological modulation and catalytic performance need to be further improved. In this study, the calcination-hydrothermal method is used to prepare a O-g-C3N4@Bi2O2CO3 (CN@BCO) composite photocatalyst from dicyandiamide and bismuth nitrate. The prepared catalyst is characterized through various methods, including X-ray diffraction (XRD) and transmission electron microscopy (TEM). Further, the effects of different parameters, such as catalyst concentration and initial pH of the reaction solution, on its photocatalytic activity are investigated. The results show that the CN@BCO sample achieves an optimal degradation rate of 98.1% for tetracycline hydrochloride (TCH) with a concentration of 20 mg/L and a removal rate of 69.4% for total organic carbon (TOC) at 40 min. The quenching experiments show that ·O2-, h+, and ·OH participate in the photocatalytic process, with ·O2- being the most dominant active species. The toxicity of the predicted TCH degradation intermediates is analyzed using Toxicity Estimation Software Tool (TEST). Overall, the CN@BCO composite exhibits excellent photocatalytic performance, making it a promising candidate for environmental purification and wastewater treatment.

6.
Insights Imaging ; 15(1): 77, 2024 Mar 18.
Article En | MEDLINE | ID: mdl-38499879

OBJECTIVE: To appraise the quality of guidelines on intravenous iodinated contrast media (ICM) use in patients with kidney disease, and to compare the recommendations among them. METHODS: We searched four literature databases, eight guideline libraries, and ten homepages of radiological societies to identify English and Chinese guidelines on intravenous ICM use in patients with kidney disease published between January 2018 and June 2023. The quality of the guidelines was assessed with the Scientific, Transparent, and Applicable Rankings (STAR) tool. RESULTS: Ten guidelines were included, with a median STAR score of 46.0 (range 28.5-61.5). The guidelines performed well in "Recommendations" domain (31/40, 78%), while poor in "Registry" (0/20, 0%) and "Protocol" domains (0/20, 0%). Nine guidelines recommended estimated glomerular filtration rate (eGFR) < 30 mL/min/1.73 m2 as the cutoff for referring patients to discuss the risk-benefit balance of ICM administration. Three guidelines further suggested that patients with an eGFR < 45 mL/min/1.73 m2 and high-risk factors also need referring. Variable recommendations were seen in the acceptable time interval between renal function test and ICM administration, and that between scan and repeated scan. Nine guidelines recommended to use iso-osmolar or low-osmolar ICM, while no consensus has been reached for the dosing of ICM. Nine guidelines supported hydration after ICM use, but their protocols varied. Drugs or blood purification therapy were not recommended as preventative means. CONCLUSION: Guidelines on intravenous ICM use in patients with kidney disease have heterogeneous quality. The scientific societies may consider joint statements on controversial recommendations for variable timing and protocols. CRITICAL RELEVANCE STATEMENT: The heterogeneous quality of guidelines, and their controversial recommendations, leave gaps in workflow timing, dosing, and post-administration hydration protocols of contrast-enhanced CT scans for patients with kidney diseases, calling for more evidence to establish a safer and more practicable workflow. KEY POINTS: • Guidelines concerning iodinated contrast media use in kidney disease patients vary. • Controversy remains in workflow timing, contrast dosing, and post-administration hydration protocols. • Investigations are encouraged to establish a safer iodinated contrast media use workflow.

7.
Mater Horiz ; 11(1): 283-296, 2024 Jan 02.
Article En | MEDLINE | ID: mdl-37943155

Enhancing the solution-processability of conjugated polymers (CPs) without diminishing their thin-film crystallinity is crucial for optimizing charge transport in organic field-effect transistors (OFETs). However, this presents a classic "Goldilocks zone" dilemma, as conventional solubility-tuning methods for CPs typically yield an inverse correlation between solubility and crystallinity. To address this fundamental issue, a straightforward skeletal randomization strategy is implemented to construct a quinoid-donor conjugated polymer, PA4T-Ra, that contains para-azaquinodimethane (p-AQM) and oligothiophenes as repeat units. A systematic study is conducted to contrast its properties against polymer homologues constructed following conventional solubility-tuning strategies. An unusually concurrent improvement of solubility and crystallinity is realized in the random polymer PA4T-Ra, which shows moderate polymer chain aggregation, the highest crystallinity and the least lattice disorder. Consequently, PA4T-Ra-based OFETs, fabricated under ambient air conditions, deliver an excellent hole mobility of 3.11 cm2 V-1 s-1, which is about 30 times higher than that of the other homologues and ranks among the highest for quinoidal CPs. These findings debunk the prevalent assumption that a random polymer backbone sequence results in decreased crystallinity. The considerable advantages of the skeletal randomization strategy illuminate new possibilities for the control of polymer aggregation and future design of high-performance CPs, potentially accelerating the development and commercialization of organic electronics.

8.
Adv Mater ; 36(4): e2304900, 2024 Jan.
Article En | MEDLINE | ID: mdl-37549425

An initial Coulombic efficiency (ICE) higher than 90% is crucial for industrial lithium-ion batteries, but numerous electrode materials are not standards compliant. Lithium trapping, due to i) incomplete solid-state reaction of Li+ generation and ii) sluggish Li+ diffusion, undermines ICE in high-capacity electrodes (e.g., conversion-type electrodes). Current approaches mitigating lithium trapping emphasize ii) nanoscaling (<50 nm) to minimize Li+ diffusion distance, followed by severe solid electrolyte interphase formation and inferior volumetric energy density. Herein, this work accentuates i) instead, to demonstrate that the lithium trapping can be mitigated by boosting the solid-state reaction reactivity. As a proof-of-concept, ternary LiFeO2 anodes, whose discharged products contain highly reactive vacancy-rich Fe nanoparticles, can alleviate lithium trapping and enable a remarkable average ICE of ≈92.77%, much higher than binary Fe2 O3 anodes (≈75.19%). Synchrotron-based techniques and theoretical simulations reveal that the solid-state reconversion reaction for Li+ generation between Fe and Li2 O can be effectively promoted by the Fe-vacancy-rich local chemical environment. The superior ICE is further demonstrated by assembled pouch cells. This work proposes a novel paradigm of regulating intrinsic solid-state chemistry to ameliorate electrochemical performance and facilitate industrial applications of various advanced electrode materials.

9.
Inorg Chem ; 63(1): 689-705, 2024 Jan 08.
Article En | MEDLINE | ID: mdl-38146716

Biomolecules play a vital role in the regulation of biomineralization. However, the characteristics of practical nucleation domains are still sketchy. Herein, the effects of the representative biomolecular sequence and conformations on calcium phosphate (Ca-P) nucleation and mineralization are investigated. The results of computer simulations and experiments prove that the line in the arrangement of dual acidic/essential amino acids with a single interval (Bc (Basic) -N (Neutral) -Bc-N-Ac (Acidic)- NN-Ac-N) is most conducive to the nucleation. 2α-helix conformation can best induce Ca-P ion cluster formation and nucleation. "Ac- × × × -Bc" sequences with α-helix are found to be the features of efficient nucleation domains, in which process, molecular recognition plays a non-negligible role. It further indicates that the sequence determines the potential of nucleation/mineralization of biomolecules, and conformation determines the ability of that during functional execution. The findings will guide the synthesis of biomimetic mineralized materials with improved performance for bone repair.


Biomineralization , Calcium Phosphates , Calcium Phosphates/chemistry , Molecular Conformation
10.
BMC Med Res Methodol ; 23(1): 292, 2023 12 13.
Article En | MEDLINE | ID: mdl-38093215

BACKGROUND: Complete reporting is essential for clinical research. However, the endorsement of reporting guidelines in radiological journals is still unclear. Further, as a field extensively utilizing artificial intelligence (AI), the adoption of both general and AI reporting guidelines would be necessary for enhancing quality and transparency of radiological research. This study aims to investigate the endorsement of general reporting guidelines and those for AI applications in medical imaging in radiological journals, and explore associated journal characteristic variables. METHODS: This meta-research study screened journals from the Radiology, Nuclear Medicine & Medical Imaging category, Science Citation Index Expanded of the 2022 Journal Citation Reports, and excluded journals not publishing original research, in non-English languages, and instructions for authors unavailable. The endorsement of fifteen general reporting guidelines and ten AI reporting guidelines was rated using a five-level tool: "active strong", "active weak", "passive moderate", "passive weak", and "none". The association between endorsement and journal characteristic variables was evaluated by logistic regression analysis. RESULTS: We included 117 journals. The top-five endorsed reporting guidelines were CONSORT (Consolidated Standards of Reporting Trials, 58.1%, 68/117), PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses, 54.7%, 64/117), STROBE (STrengthening the Reporting of Observational Studies in Epidemiology, 51.3%, 60/117), STARD (Standards for Reporting of Diagnostic Accuracy, 50.4%, 59/117), and ARRIVE (Animal Research Reporting of In Vivo Experiments, 35.9%, 42/117). The most implemented AI reporting guideline was CLAIM (Checklist for Artificial Intelligence in Medical Imaging, 1.7%, 2/117), while other nine AI reporting guidelines were not mentioned. The Journal Impact Factor quartile and publisher were associated with endorsement of reporting guidelines in radiological journals. CONCLUSIONS: The general reporting guideline endorsement was suboptimal in radiological journals. The implementation of reporting guidelines for AI applications in medical imaging was extremely low. Their adoption should be strengthened to facilitate quality and transparency of radiological study reporting.


Artificial Intelligence , Periodicals as Topic , Humans , Checklist , Publishing , Reference Standards
11.
J Magn Reson Imaging ; 2023 Dec 19.
Article En | MEDLINE | ID: mdl-38112305

BACKGROUND: Quantitative diffusion metrics provide additional microstructural information of diseases. The robustness of quantitative diffusion metrics should be established before clinical application. PURPOSE: To evaluate the variability and reproducibility of quantitative diffusion MRI metrics. STUDY TYPE: Prospective. POPULATION: 14 volunteers (7 men; median age, range, 28, 26-59 years). FIELD STRENGTH/SEQUENCE: 3.0-T/Diffusion spectrum imaging. ASSESSMENT: Brain MRI studies were performed four times per subject: involving different combinations of coil types and voxel sizes. Regions of interest of 13 brain anatomical sites were drawn by one observer twice and another observer once to allow interobserver and intraobserver reproducibility assessment. Twenty-five quantitative metrics were calculated using four diffusion models. STATISTICAL TESTS: The variability was evaluated with coefficients of variation (CV), and quartile coefficient of dispersion (QCD). The reproducibility was assessed with intraclass correlation coefficient (ICC), and concordance correlation coefficient (CCC). Wilcoxon signed rank test was used to compare the influence of factors on robustness of quantitative diffusion metrics. A two-tailed P < 0.05 was considered statistically significant. RESULTS: The variability of quantitative diffusion metrics showed CV of 2.4%-68.2%, and QCD of 0.6%-48.2%, respectively. The reproducibility of scans using 20-channel coils with voxels of 2 × 2 × 2 mm3 and 3 × 3 × 3 mm3 , respectively (ICC 0.03-0.84, CCC 0.03-0.84) was significantly worse than that of repeated scans using a 20-channel coil with a voxel size of 2 × 2 × 2 mm3 (ICC of 0.74-0.97, CCC 0.74-0.97) and that of scans using 20- and 64-channel coils, respectively, with a voxel size of 2 × 2 × 2 mm3 (ICC 0.59-0.95, CCC 0.59-0.95). The intraobserver reproducibility (ICC 0.49-0.94, CCC 0.49-0.94) was significantly better than the interobserver reproducibility (ICC 0.28-0.91, CCC 0.28-0.91). DATA CONCLUSION: Our study indicated that the voxel size has a greater influence on the reproducibility of quantitative diffusion metrics than scan-rescans and coils. The reproducibility within one observer was higher than that between two observers. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.

12.
Environ Pollut ; 334: 122162, 2023 Oct 01.
Article En | MEDLINE | ID: mdl-37429487

The pollution of polycyclic aromatic hydrocarbons (PAHs) and halogenated PAHs (Cl/Br-PAHs) caused by electronic waste dismantling activities have attracted considerable attention. The present study investigated the emissions and formation of PAHs and Cl/Br-PAHs based on the combustion of printed circuit boards simulating electronic waste dismantling process. The emission factor of ΣPAHs was 648 ± 56 ng/g, which was much lower than that of ΣCl/Br-PAHs (8.80 × 104 ± 9.14 × 103 ng/g). From 25 to 600 °C, the emission rate of ΣPAHs reached a sub-peak of 7.39 ± 1.85 ng/(g•min) at 350 °C, then increased gradually with the fastest rate of 19.9 ± 21.8 ng/(g•min) at 600 °C, whereas that of ΣCl/Br-PAHs was the fastest at 350 °C with a rate of 597 ± 106 ng/(g•min), then decreased gradually. The present study suggested that the formation pathways of PAHs and Cl/Br-PAHs are by de novo synthesis. Low molecular weight PAHs were readily partitioned into gas and particle phases, whereas high molecular weight fused PAHs were only detected in oil phase. However, the proportion of Cl/Br-PAHs in particle and oil phases were different from that of gas phase, whereas similar to that of the total emission. In addition, PAH and Cl/Br-PAH emission factors were used to estimate the emission intensity of pyrometallurgy project in Guiyu Circular Economy Industrial Park, and it was shown that approximately 1.30 kg PAHs and 176 kg Cl/Br-PAHs would be emitted annually. This study revealed that Cl/Br-PAHs would be formed by de novo synthesis, and for the first time provided the emission factors of Cl/Br-PAHs during the heat treatment process of printed circuit board, as well as estimated the contribution of pyrometallurgy, a new electronic waste recovery technology, to environmental Cl/Br-PAH pollution, which provides potential scientific information for governmental decision-making on the control of Cl/Br-PAHs.


Electronic Waste , Polycyclic Aromatic Hydrocarbons , Environmental Monitoring , Polycyclic Aromatic Hydrocarbons/analysis , Electronic Waste/analysis , China , Industry
13.
ACS Appl Mater Interfaces ; 15(31): 37232-37246, 2023 Aug 09.
Article En | MEDLINE | ID: mdl-37486779

Poly(etheretherketone) (PEEK) is regarded as an attractive orthopedic material because of its good biocompatibility and mechanical properties similar to natural bone. The efficient activation methods for the surfaces of PEEK matrix materials have become a hot research topic. In this study, a method using a femtosecond laser (FSL) followed by hydroxylation was developed to achieve efficient bioactivity. It produces microstructures, amorphous carbon, and grafted -OH groups on the PEEK surface to enhance hydrophilicity and surface energy. Both experimental and simulation results show that our modification leads to a superior ability to induce apatite deposition on the PEEK surface. The results also demonstrate that efficient grafting of C-OH through FSL-hydroxylation can effectively enhance cell proliferation and osteogenic differentiation compared to other modifications, thus improving osteogenic activity. Overall, FSL hydroxylation treatment is proved to be a simple, efficient, and environmentally friendly modification method for PEEK activation. It could expand the applications of PEEK in orthopedics, as well as promote the surface modification and structural design of other polymeric biomaterials to enhance bioactivity.


Osteogenesis , Polyethylene Glycols , Polyethylene Glycols/chemistry , Ketones/pharmacology , Ketones/chemistry , Hydroxylation , Benzophenones , Lasers , Surface Properties
14.
J Orthop Surg Res ; 18(1): 414, 2023 Jun 07.
Article En | MEDLINE | ID: mdl-37287036

PURPOSE: To systematically assess the quality of radiomics research in giant cell tumor of bone (GCTB) and to test the feasibility of analysis at the level of radiomics feature. METHODS: We searched PubMed, Embase, Web of Science, China National Knowledge Infrastructure, and Wanfang Data to identify articles of GCTB radiomics until 31 July 2022. The studies were assessed by radiomics quality score (RQS), transparent reporting of a multivariable prediction model for individual prognosis or diagnosis (TRIPOD) statement, checklist for artificial intelligence in medical imaging (CLAIM), and modified quality assessment of diagnostic accuracy studies (QUADAS-2) tool. The radiomic features selected for model development were documented. RESULTS: Nine articles were included. The average of the ideal percentage of RQS, the TRIPOD adherence rate and the CLAIM adherence rate were 26%, 56%, and 57%, respectively. The risk of bias and applicability concerns were mainly related to the index test. The shortness in external validation and open science were repeatedly emphasized. In GCTB radiomics models, the gray level co-occurrence matrix features (40%), first order features (28%), and gray-level run-length matrix features (18%) were most selected features out of all reported features. However, none of the individual feature has appeared repeatably in multiple studies. It is not possible to meta-analyze radiomics features at present. CONCLUSION: The quality of GCTB radiomics studies is suboptimal. The reporting of individual radiomics feature data is encouraged. The analysis at the level of radiomics feature has potential to generate more practicable evidence for translating radiomics into clinical application.


Bone Neoplasms , Giant Cell Tumor of Bone , Humans , Artificial Intelligence , Giant Cell Tumor of Bone/diagnostic imaging , Diagnostic Imaging , Biomarkers , Bone Neoplasms/diagnostic imaging
15.
Zhongguo Zhong Yao Za Zhi ; 48(9): 2480-2489, 2023 May.
Article Zh | MEDLINE | ID: mdl-37282877

Qualitative and quantitative analysis of 2-(2-phenylethyl) chromones in sodium chloride(NaCl)-treated suspension cells of Aquilaria sinensis was conducted by UPLC-Q-Exactive-MS and UPLC-QQQ-MS/MS. Both analyses were performed on a Waters T3 column(2.1 mm×50 mm, 1.8 µm) with 0.1% formic acid aqueous solution(A)-acetonitrile(B) as mobile phases at gradient elution. MS data were collected by electrospray ionization in positive ion mode. Forty-seven phenylethylchromones was identified from NaCl-treated suspension cell samples of A. sinensis using UPLC-Q-Exactive-MS, including 22 flindersia-type 2-(2-phenylethyl) chromones and their glycosides, 10 5,6,7,8-tetrahydro-2-(2-phenylethyl) chromones and 15 mono-epoxy or diepoxy-5,6,7,8-tetrahydro-2-(2-phenylethyl) chromones. Additionally, 25 phenylethylchromones were quantitated by UPLC-QQQ-MS/MS. Overall, the rapid and efficient qualitative and quantitative analysis of phenylethylchromones in NaCl-treated suspension cells of A. sinensis by two LC-MS techniques, provides an important reference for the yield of phenylethylchromones in Aquilariae Lignum Resinatum using in vitro culture and other biotechnologies.


Chromones , Thymelaeaceae , Sodium Chloride , Chromatography, Liquid , Flavonoids , Tandem Mass Spectrometry
16.
Insights Imaging ; 14(1): 111, 2023 Jun 19.
Article En | MEDLINE | ID: mdl-37336830

OBJECTIVE: To conduct an overview of meta-analyses of radiomics studies assessing their study quality and evidence level. METHODS: A systematical search was updated via peer-reviewed electronic databases, preprint servers, and systematic review protocol registers until 15 November 2022. Systematic reviews with meta-analysis of primary radiomics studies were included. Their reporting transparency, methodological quality, and risk of bias were assessed by PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) 2020 checklist, AMSTAR-2 (A MeaSurement Tool to Assess systematic Reviews, version 2) tool, and ROBIS (Risk Of Bias In Systematic reviews) tool, respectively. The evidence level supporting the radiomics for clinical use was rated. RESULTS: We identified 44 systematic reviews with meta-analyses on radiomics research. The mean ± standard deviation of PRISMA adherence rate was 65 ± 9%. The AMSTAR-2 tool rated 5 and 39 systematic reviews as low and critically low confidence, respectively. The ROBIS assessment resulted low, unclear and high risk in 5, 11, and 28 systematic reviews, respectively. We reperformed 53 meta-analyses in 38 included systematic reviews. There were 3, 7, and 43 meta-analyses rated as convincing, highly suggestive, and weak levels of evidence, respectively. The convincing level of evidence was rated in (1) T2-FLAIR radiomics for IDH-mutant vs IDH-wide type differentiation in low-grade glioma, (2) CT radiomics for COVID-19 vs other viral pneumonia differentiation, and (3) MRI radiomics for high-grade glioma vs brain metastasis differentiation. CONCLUSIONS: The systematic reviews on radiomics were with suboptimal quality. A limited number of radiomics approaches were supported by convincing level of evidence. CLINICAL RELEVANCE STATEMENT: The evidence supporting the clinical application of radiomics are insufficient, calling for researches translating radiomics from an academic tool to a practicable adjunct towards clinical deployment.

17.
Biomimetics (Basel) ; 8(2)2023 Jun 15.
Article En | MEDLINE | ID: mdl-37366857

Currently, platelet-rich plasma (PRP) is an attractive additive for bone repair materials. PRP could enhance the osteoconductive and osteoinductive of bone cement, as well as modulate the degradation rate of calcium sulfate hemihydrate (CSH). The focus of this study was to investigate the effect of different PRP ratios (P1: 20 vol%, P2: 40 vol%, and P3: 60 vol%) on the chemical properties and biological activity of bone cement. The injectability and compressive strength of the experimental group were significantly higher than those of the control. On the other hand, the addition of PRP decreased the crystal size of CSH and prolonged the degradation time. More importantly, the cell proliferation of L929 and MC3T3-E1 cells was promoted. Furthermore, qRT-PCR, alizarin red staining, and western blot analyses showed that the expressions of osteocalcin (OCN) and Runt-related transcription factor 2 (Runx2) genes and ß-catenin protein were up-regulated, and mineralization of extracellular matrix was enhanced. Overall, this study provided insight into how to improve the biological activity of bone cement through PRP incorporation.

18.
J Digit Imaging ; 36(4): 1390-1407, 2023 08.
Article En | MEDLINE | ID: mdl-37071291

This study is aimed to evaluate effects of deep learning image reconstruction (DLIR) on image quality in single-energy CT (SECT) and dual-energy CT (DECT), in reference to adaptive statistical iterative reconstruction-V (ASIR-V). The Gammex 464 phantom was scanned in SECT and DECT modes at three dose levels (5, 10, and 20 mGy). Raw data were reconstructed using six algorithms: filtered back-projection (FBP), ASIR-V at 40% (AV-40) and 100% (AV-100) strength, and DLIR at low (DLIR-L), medium (DLIR-M), and high strength (DLIR-H), to generate SECT 120kVp images and DECT 120kVp-like images. Objective image quality metrics were computed, including noise power spectrum (NPS), task transfer function (TTF), and detectability index (d'). Subjective image quality evaluation, including image noise, texture, sharpness, overall quality, and low- and high-contrast detectability, was performed by six readers. DLIR-H reduced overall noise magnitudes from FBP by 55.2% in a more balanced way of low and high frequency ranges comparing to AV-40, and improved the TTF values at 50% for acrylic inserts by average percentages of 18.32%. Comparing to SECT 20 mGy AV-40 images, the DECT 10 mGy DLIR-H images showed 20.90% and 7.75% improvement in d' for the small-object high-contrast and large-object low-contrast tasks, respectively. Subjective evaluation showed higher image quality and better detectability. At 50% of the radiation dose level, DECT with DLIR-H yields a gain in objective detectability index compared to full-dose AV-40 SECT images used in daily practice.


Deep Learning , Humans , Algorithms , Image Processing, Computer-Assisted , Phantoms, Imaging , Radiation Dosage , Tomography, X-Ray Computed , Radiographic Image Interpretation, Computer-Assisted
19.
Environ Pollut ; 329: 121709, 2023 Jul 15.
Article En | MEDLINE | ID: mdl-37116567

The emission and gas-particle partitioning characteristics in various functional areas of production lines are still unknown. However, flame-retardant manufacturing activities are the primary emission source of flame retardants. Thus, fine particles and gases were investigated in three functional areas of a decabromodiphenyl ethane production line, i.e., polybrominated diphenyl ethers (PBDEs), novel brominated flame retardants (NBFRs), dechlorane plus (DPs), and organophosphorus flame retardants (OPFRs) in a flame-retardant manufacturing factory. High levels of PBDEs (8.02 × 103-4.16 × 104 pg/m3), NBFRs (6.05 × 103-1.92 × 105 pg/m3), and DPs (89.5-5.20 × 103 pg/m3) were found in various functional areas, suggesting manufacturing activities were a primary emission source. In contrast, OPFRs were derived from long-range transport or other non-industrial sources. Varied concentrations of PBDEs, NBFRs, and DPs were observed in different production lines, higher in the reaction zone area than others. As the predominant compounds, decabromodiphenyl ether, decabromodiphenyl ethane, syn-DP, and tris(chloropropyl) phosphate accounted for 54.7%, 89.3%, 93.4%, and 34.7% of PBDEs, NBFRs, DPs, and OPFRs, respectively. Three models were used to predict the gas-particle partitioning of the halogenated flame retardants emitted from manufacturing activities. The Li-Jia Empirical Model predicted the gas-particle partitioning behavior well. This research shows that the adsorption-desorption process of the halogenated flame retardants between the gaseous and particulate phases did not reach equilibrium.


Environmental Monitoring , Flame Retardants , Flame Retardants/analysis , Halogenated Diphenyl Ethers/analysis , Organophosphorus Compounds
20.
Eur Radiol ; 33(8): 5331-5343, 2023 Aug.
Article En | MEDLINE | ID: mdl-36976337

OBJECTIVES: To evaluate image quality, diagnostic acceptability, and lesion conspicuity in abdominal dual-energy CT (DECT) using deep learning image reconstruction (DLIR) compared to those using adaptive statistical iterative reconstruction-V (Asir-V) at 50% blending (AV-50), and to identify potential factors impacting lesion conspicuity. METHODS: The portal-venous phase scans in abdominal DECT of 47 participants with 84 lesions were prospectively included. The raw data were reconstructed to virtual monoenergetic image (VMI) at 50 keV using filtered back-projection (FBP), AV-50, and DLIR at low (DLIR-L), medium (DLIR-M), and high strength (DLIR-H). A noise power spectrum (NPS) was generated. CT number and standard deviation values of eight anatomical sites were measured. Signal-to-noise (SNR), and contrast-to-noise ratio (CNR) values were calculated. Five radiologists assessed image quality in terms of image contrast, image noise, image sharpness, artificial sensation, and diagnostic acceptability, and evaluated the lesion conspicuity. RESULTS: DLIR further reduced image noise (p < 0.001) compared to AV-50 while better preserved the average NPS frequency (p < 0.001). DLIR maintained CT number values (p > 0.99) and improved SNR and CNR values compared to AV-50 (p < 0.001). DLIR-H and DLIR-M showed higher ratings in all image quality analyses than AV-50 (p < 0.001). DLIR-H provided significantly better lesion conspicuity than AV-50 and DLIR-M regardless of lesion size, relative CT attenuation to surrounding tissue, or clinical purpose (p < 0.05). CONCLUSIONS: DLIR-H could be safely recommended for routine low-keV VMI reconstruction in daily contrast-enhanced abdominal DECT to improve image quality, diagnostic acceptability, and lesion conspicuity. KEY POINTS: • DLIR is superior to AV-50 in noise reduction, with less shifts of the average spatial frequency of NPS towards low frequency, and larger improvements of NPS noise, noise peak, SNR, and CNR values. • DLIR-M and DLIR-H generate better image quality in terms of image contrast, noise, sharpness, artificial sensation, and diagnostic acceptability than AV-50, while DLIR-H provides better lesion conspicuity than AV-50 and DLIR-M. • DLIR-H could be safely recommended as a new standard for routine low-keV VMI reconstruction in contrast-enhanced abdominal DECT to provide better lesion conspicuity and better image quality than the standard AV-50.


Deep Learning , Humans , Prospective Studies , Tomography, X-Ray Computed/methods , Image Processing, Computer-Assisted/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Algorithms , Radiation Dosage
...