Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Sci Rep ; 11(1): 9348, 2021 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-33931680

RESUMEN

Degradation at the modular head-neck interface in total hip arthroplasty (THA) is predominately expressed in the form of corrosion and fretting, potentially causing peri-prosthetic failure by adverse reactions to metal debris. This retrieval study aimed to quantify variations in stem taper surface topographies and to assess the influence on the formation of corrosion and/or fretting in titanium alloy stem tapers combined with metal and ceramic heads. Four hip stem designs (Alloclassic, CLS, Bicontact and SL-Plus) were characterized using high-resolution 3D microscopy, and corrosion and fretting were rated using the Goldberg scoring scheme. Quantification of the taper surface topographies revealed a high variability in surface characteristics between threaded stem tapers: Alloclassic and CLS tapers feature deeply threaded trapezoid-shaped profiles with thread heights over 65 µm. The sawtooth-shaped Bicontact and triangular SL-Plus taper are characterized by low thread heights below 14 µm. Significantly lower corrosion and fretting scores were observed in lightly threaded compared to deeply threaded tapers in ceramic head combinations. No significant differences in corrosion or fretting scores with thread height were found in pairings with metal heads. Understanding the relationship between stem taper surface topography and the formation of corrosion and fretting could help to improve the performance of modern THAs and lead to longer-lasting clinical results.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Cerámica/química , Aleaciones de Cromo/química , Articulación de la Cadera/cirugía , Prótesis de Cadera/efectos adversos , Estrés Mecánico , Anciano , Corrosión , Femenino , Articulación de la Cadera/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Propiedades de Superficie
2.
Hip Int ; 30(1_suppl): 72-77, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32907419

RESUMEN

INTRODUCTION: Identification of the pathogen in case of a periprosthetic joint infection (PJI) remains 1 of the greatest challenges in septic surgery. Rapid germ identification enables timely, specific, antimicrobial therapy. The first multiplex PCR (polymerase chain reaction) generation (Unyvero-i60) enables germ detection within 5 hours with a sensitivity of 78.8% and a specificity of 100%. The aim of this study is to investigate the performance of the new generation of cartridges (Unyvero-ITI) of multiplex PCR in the case of a PJI. METHODS: In a prospective study, intraoperatively aspirated synovial fluid from 97 patients with aseptic or septic hip or knee revision surgery (49 aseptic, 48 septic) was examined with the multiplex PCR system (Unyvero-ITI) and the results were compared with the MSIS criteria. In addition, the time until the microbiological result was obtained in the event of a germ detection was documented. RESULTS: The multiplex PCR showed a germ detection with a sensitivity of 85.1% and a specificity of 98.0%. In 7 cases a false negative result was found and in one patient a false positive result was found. The general accuracy of this test procedure was 91.8%. The detection of germs was carried out within 5 hours with the multiplex PCR compared to 4.9 days in conventional microbiological diagnostics. CONCLUSIONS: The new generation of multiplex-PCR was able to improve germ detection. The possibility of prompt detection of germs offers the option of faster, targeted antimicrobial therapy. This diagnostic tool offers significant advantages, particularly in the context of an acute periprosthetic infection.


Asunto(s)
Artritis Infecciosa/diagnóstico , ADN Bacteriano/análisis , Reacción en Cadena de la Polimerasa Multiplex/métodos , Infecciones Relacionadas con Prótesis/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Reoperación , Líquido Sinovial
3.
Hip Int ; 30(1_suppl): 19-25, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32907422

RESUMEN

BACKGROUND: Controversies exist regarding the association of elevated serum glycated haemoglobin (HbA1c) levels and postoperative surgical site infection (SSI) or prosthetic joint infection (PJI) in the setting of total hip and knee arthroplasty (THA and TKA). The purpose of the current study was to determine the prevalence of unknown and uncontrolled diabetes mellitus (DM) in a consecutive series and to investigate the association between postoperative wound complications or SSI/PJI and elevated HbA1c in patients undergoing TJA. METHODS: In this prospective single-centre study, HbA1c was determined for patients undergoing elective primary, aseptic or septic revision THA and TKA, between September 2017 and March 2018. Prevalence of DM, unknown and uncontrolled diabetes were reported. Occurrence of 90-day wound healing disorders (WHD) as well as SSI or PJI were observed. Considering the HbA1c threshold ⩾6.5%, a comparative analysis between patients with and without WHD and SSI or PJI for the whole study cohort, as well as for each arthroplasty group, was performed. Receiver operating characteristic (ROC) curves were developed to quantify the predictive power of HbA1c with regard to WHD and infection complications. A total of 1488 patients were included for final analysis. There were 1127 primary THA and TKA (75.7%), 272 aseptic revisions (18.3%) and 89 septic revisions (6.0%). The known diabetic patients constituted 9.9% of the whole study cohort. RESULTS: The majority had uncontrolled DM (67%). Prevalence of unknown DM was 11.1%. The results reveal the prevalence for the German population and might be different in other regions. A total of 57 patients (3.7%) experienced postoperative wound or infectious complications. PJI occurred in only 5 patients (0.03%). There was no significant difference between patients with HbA1c <6.5% and patients with HbA1c ⩾6.5% (p = 0.092). CONCLUSIONS: We demonstrated that prevalence of unknown and uncontrolled DM in patients undergoing TJA is increasing, however; routine preoperative determination of the HbA1c value to prevent possible postoperative wound or infectious complications remains debatable. Larger studies investigating the optimal HbA1c level, as well as other predictors are required.


Asunto(s)
Artritis Infecciosa/sangre , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Hemoglobina Glucada/metabolismo , Infecciones Relacionadas con Prótesis/sangre , Biomarcadores/sangre , Femenino , Humanos , Masculino , Estudios Prospectivos , Reoperación , Factores de Riesgo
4.
J Arthroplasty ; 34(6): 1221-1226, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30857953

RESUMEN

BACKGROUND: Although 2-stage revision is still considered the gold standard for surgical management of periprosthetic joint infection (PJI), 1-stage revision has been reported to be as effective. Long-term reports for 1-stage revision in hip PJIs are lacking. METHODS: We reviewed our 10-11 years of results of 85 patients who underwent 1-stage exchange of the hip with an antibiotic-loaded bone cemented prosthesis due to PJI to determine the following: (1) What is the infection-free survival? (2) What is the overall survival? and (3) What are the long-term clinical outcomes? All 1-stage revision total hip arthroplasties (THAs) for infection between January 2006 and December 2007, with a minimum 10-year follow-up (range 10-11), were included in this retrospective cohort. Patients from another country or patients who were unable to participate were excluded. Eighty-five patients with a hip PJI were available at the last follow-up. Thirty-seven patients died during the 10-year study. Harris Hip Scores were recorded before the surgery and at last follow-up. Failures are reported as infection-related or aseptic. RESULTS: The 10-year infection-free survival was 94% and the surgery-free survival was 75.9%. The Harris Hip Scores improved from 43 (range 3-91) to 75 (range 10-91) (P < .001). The main indication for re-revision after 1-stage exchange was instability (10/20 patients). CONCLUSION: One-stage exchange of the hip for PJI is a reliable treatment option with high rate of infection control and long-lasting favorable outcomes.


Asunto(s)
Artritis Infecciosa/cirugía , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Infecciones Relacionadas con Prótesis/cirugía , Reoperación/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Antibacterianos/uso terapéutico , Artritis Infecciosa/tratamiento farmacológico , Artritis Infecciosa/etiología , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Articulación de la Cadera/cirugía , Humanos , Masculino , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/etiología , Reoperación/métodos , Estudios Retrospectivos
5.
Int Orthop ; 42(4): 755-760, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29435622

RESUMEN

PURPOSE: The aim of the study was to quantify the bacterial contamination rate of electrocautery tips during primary total joint replacement (TJR), as well as during aseptic and septic revision TJR. METHODS: A total of 150 electrocautery tips were collected between April and July 2017. TJR surgeries were divided into three groups: (1) primary, (2) aseptic and (3) septic revisions. In each group, a total of 50 electrocautery tips were collected. A monopolar electrocautery with a reusable stainless-steel blade tip was used in all cases. The rate of bacterial contamination was determined for all groups. Correlation of exposure time and type of surgery was analyzed. RESULTS: The overall bacterial contamination rate was 14.7% (95% CI 9.4 to 21.4%). The highest contamination rate occurred in the septic revision group (30.0%; 95% CI 17.9 to 44.6%), followed by the primary cases group (10.0%; 95% CI 3.3 to 21.8%) and the aseptic revision group (4.0%; 95% CI 0.5 to 13.7%). Exposure time did not affect the bacterial contamination rate. In 12 out of 15 (80%) contaminations identified in the septic group, we found the same causative microorganism of the prosthetic joint infection on the electrocautery tip. CONCLUSIONS: The bacterial contamination of the electrocautery tips is relatively high, especially during septic hip revision arthroplasty. Electrocautery tips should be changed after debridement of infected tissue.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Electrocoagulación/efectos adversos , Contaminación de Equipos/estadística & datos numéricos , Reoperación/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Rodilla/instrumentación , Electrocoagulación/instrumentación , Femenino , Articulación de la Cadera/microbiología , Articulación de la Cadera/cirugía , Humanos , Articulación de la Rodilla/microbiología , Articulación de la Rodilla/cirugía , Masculino , Técnicas Microbiológicas , Persona de Mediana Edad , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/microbiología
6.
J Bone Jt Infect ; 2(4): 175-183, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29119076

RESUMEN

Purpose Identification of bacteria and susceptibility are fundamental in periprosthetic joint infection (PJI). Especially in the case of systemic inflammatory response syndrome (SIRS) rapid detection of pathogens is essential for proper therapy. Bacterial cultures are time consuming. The polymerase chain reaction (PCR) is a non-culture molecular method and is able to rapidly identify pathogens and their resistance genes. Multiplex PCR (mPCR) can amplify several different DNA sequences simultaneously. The aim of this study was to show the value of mPCR for early diagnosis of PJI. Methods 60 patients undergoing total hip or knee revisions were recruited in this prospective single-centre-study. Three groups were created: 26 patients with aseptic loosening (negative control), 26 patients with chronic PJI, and 8 patients with acute PJI/SIRS. We compared the results of joint aspirates obtained intraoperatively investigated by mPCR with the microbiology results of tissue specimens. Results The overall sensitivity of mPCR was 78.8% (95% CI, 61.1 - 91.0%), the specificity was 100% (95% CI, 87.2 - 100%), the negative predictive value was 79.4% (95% CI, 62.1 - 91.3%), the positive predictive value was 100% (95% CI, 86.8 - 100%), and the overall accuracy was 88.3% (95% CI, 77.4 - 95.2%). The overall accuracy in acute infections/SIRS (87.5%) was greater than in late chronic PJI (76.9%). In PJI the mPCR was able to provide the results within 5 hours whereas the mean time for cultures was 6.4 days. Conclusions Multiplex PCR is a reliable diagnostic tool in PJI management, especially in acute cases complicated with SIRS. Early diagnosis within several hours is possible, targeted antibiotic treatment can be started promptly.

7.
Hip Int ; 27(2): 128-133, 2017 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-27886357

RESUMEN

BACKGROUND: Determining the aetiology of persistent pain following total hip arthroplasty (THA) can be challenging. Impingement of the iliopsoas muscle due to a malpositioned acetabular component after THA might be a potential cause of postoperative groin pain. METHODS: We retrospectively analysed the data of 12 consecutive patients from our orthopaedic department who underwent cup revision for painful iliopsoas impingement after primary THA. RESULTS: Thorough physical examination as well as radiological assessment of the included patients revealed that malpositioning of the acetabular component provoked iliopsoas impingement.The Harris Hip Score and the orientation of the acetabular component before and after surgical revision at an average follow-up of 56 months were analysed. CONCLUSIONS: We were able to demonstrate that surgical cup revision and reorientation resulted in distinctly improved scores and is a feasible option to effectively treat persistent iliopsoas impingement due to a malpositioned acetabular component following THA.


Asunto(s)
Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Pinzamiento Femoroacetabular/cirugía , Prótesis de Cadera , Reoperación/métodos , Acetábulo/fisiopatología , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Dolor Crónico/etiología , Dolor Crónico/cirugía , Estudios de Cohortes , Femenino , Pinzamiento Femoroacetabular/diagnóstico por imagen , Pinzamiento Femoroacetabular/etiología , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Falla de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Resultado del Tratamiento
8.
Orthop Rev (Pavia) ; 7(1): 5623, 2015 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-25874061

RESUMEN

Fungal periprosthetic joint infection (PJI) is a rare but devastating complication following total knee arthroplasty (TKA). A standardized procedure regarding an accurate treatment of this serious complication of knee arthroplasty is lacking. In this systematic review, we collected data from 36 studies with a total of 45 reported cases of a TKA complicated by a fungal PJI. Subsequently, an analysis focusing on diagnostic, medicaments and surgical procedures in the pre-, intra- and postoperative period was performed. Candida spp. accounts for about 80% (36 out of 45 cases) of fungal PJIs and is therefore the most frequently reported pathogen. A systemic antifungal therapy was administered in all but one patient whereas a local antifungal therapy, e.g. the use of an impregnated spacer, is of inferior relevance. Resection arthroplasty with delayed re-implantation (two-stage revision) was the surgical treatment of choice. However, in 50% of all reported cases the surgical therapy was heterogeneous. The outcome under a combined therapy was moderate with recurrent fungal PJI in 11 patients and subsequent bacterial PJI as a main complication in 5 patients. In summary, this systematic review integrates data from up to date 45 reported cases of a fungal PJI of a TKA. On the basis of the current literature strategies for the treatment of this devastating complication after TKA are discussed.

9.
Orthop Rev (Pavia) ; 7(1): 5748, 2015 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-25874063

RESUMEN

Periprosthetic joint infection (PJI) is a severe complication of total joint arthroplasty with an incidence of approximately 1%. Due to the high risk of persisting infection, successful treatment of fungal PJI is challenging. The purpose of this study was to gain insight into the current management of fungal PJI of the hip and, by systematically reviewing the cases published so far, to further improve the medical treatment of this serious complication of total hip arthroplasty. Thus, we conducted a systematic review of the available literature concerning fungal PJI in total hip arthroplasty, including 45 cases of fungal PJI. At the moment a two-stage revision procedure is favorable and there is an ongoing discussion on the therapeutic effect of antifungal drug loaded cement spacers on fungal periprosthetic infections of the hip. Due to the fact that there is rare experience with it, there is urgent need to establish guidelines for the treatment of fungal infections of total hip arthroplasty.

10.
J Orthop Trauma ; 28(7): 403-9, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24949955

RESUMEN

OBJECTIVES: To compare 2 different femoral neck augmentation techniques at improving the mechanical strength of the femoral neck. METHODS: Twenty pairs of human cadaveric femora were randomly divided into 2 groups. In 1 group, the femora were augmented with a steel spiral; the other group with the cemented technique. The untreated contralateral side served as an intraindividual control. Fracture strength was evaluated using an established biomechanical testing scenario mimicking a fall on the greater trochanter (Hayes fall). RESULTS: The peak load to failure was significantly higher in the steel spiral group (P = 0.0024) and in the cemented group (P = 0.001) compared with the intraindividual controls. The peak load to failure showed a median of 3167 N (1825-5230 N) in the spiral group and 2485 N (1066-4395 N) in the spiral control group. The peak load to failure in the cemented group was 3698 N (SD ± 1249 N) compared with 2763 N (SD ± 1335 N) in the cement control group. Furthermore, fracture displacement was clearly reduced in the steel spiral group. CONCLUSIONS: Femoral augmentations using steel spirals or cement-based femoroplasty are technically feasible procedures. Our results demonstrate that a prophylactic reinforced proximal femur has higher strength when compared with the untreated contralateral limb. Prophylactic augmentation has potential to become an auxiliary treatment option to protect the osteoporotic proximal femur against fracture.


Asunto(s)
Fracturas del Cuello Femoral/prevención & control , Fracturas del Cuello Femoral/cirugía , Fémur/cirugía , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles , Cadáver , Cementación , Femenino , Humanos , Masculino , Metales , Prótesis e Implantes
11.
Hip Int ; 24(1): 103-7, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24474409

RESUMEN

We report the case of a 30-year-old patient initially treated for a proximal femoral Ewing's sarcoma when 12 years old. Index treatment comprised tumour resection and total hip arthroplasty. Two years later revision for aseptic loosening was performed. Subsequently, six further surgical revisons were performed for varying causes. At the age of 23 years the proximal femur was resected and a proximal femoral endoprosthesis implanted.Eighteen years after initial diagnosis the patient presented with recurrent aseptc loosening. Both the proximal femur and acetabulum were reconstructed. For acetabular reconstruction a structural allograft and a tantalum cup were utilised. Reconstruction of the femur utilsed extensive wire mesh and circlage wiring with impaction bone allograft into which a femoral stem was implanted.At one-year follow-up the patient was pain free, had no evidence of infection with satisfactory radiographs and no evidence of implant loosening. This is the first case reporting an extended proximal femoral reconstruction with a wire mesh in combination with impaction bone grafting in an aseptic loosened proximal femoral replacement following Ewing's Sarcoma.


Asunto(s)
Neoplasias Óseas/cirugía , Trasplante Óseo/métodos , Necrosis de la Cabeza Femoral/cirugía , Fémur/cirugía , Procedimientos de Cirugía Plástica/métodos , Sarcoma de Ewing/cirugía , Adulto , Artroplastia de Reemplazo de Cadera , Neoplasias Óseas/diagnóstico por imagen , Fémur/diagnóstico por imagen , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Estudios de Seguimiento , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Radiografía , Reoperación , Sarcoma de Ewing/diagnóstico por imagen , Trasplante Homólogo , Resultado del Tratamiento
13.
J Orthop Res ; 32(1): 31-8, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24019186

RESUMEN

The validity of dual energy X-ray absorptiometry (DXA) and peripheral quantitative computed tomography (pQCT) measurements as predictors of pertrochanteric and femoral neck fracture loads was compared in an experimental simulation of a fall on the greater trochanter. 65 proximal femora were harvested from patients at autopsy. All specimens were scanned with use of DXA for areal bone mineral density and pQCT for volumetric densities at selected sites of the proximal femur. A three-point bending test simulating a side-impact was performed to determine fracture load and resulted in 16 femoral neck and 49 pertrochanteric fractures. Regression analysis revealed that DXA BMD trochanter was the best variable at predicting fracture load of pertrochanteric fractures with an adjusted R(2) of 0.824 (p < 0.0001). There was no correlation between densitometric parameters and the fracture load of femoral neck fractures. A significant correlation further was found between body weight, height, femoral head diameter, and neck length on the one side and fracture load on the other side, irrespective of the fracture type. Clinically, the DXA BMD trochanter should be favored and integrated routinely as well as biometric and geometric parameters, particularly in elderly people with known osteoporosis at risk for falls.


Asunto(s)
Absorciometría de Fotón/métodos , Fracturas del Cuello Femoral/diagnóstico por imagen , Fracturas del Cuello Femoral/fisiopatología , Osteoporosis/diagnóstico por imagen , Osteoporosis/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Absorciometría de Fotón/normas , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos/fisiología , Densidad Ósea/fisiología , Cadáver , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/normas , Soporte de Peso/fisiología
15.
Arch Orthop Trauma Surg ; 133(11): 1575-8, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23912420

RESUMEN

In the setting of end-stage osteoarthritis of the knee, total knee arthroplasty is the gold-standard treatment. Recently, a minimally invasive, joint preserving treatment option in the treatment of medial osteoarthritis of the knee has been developed. It is called the KineSpring(®) (Moximed(®) International GmbH, Zurich, Switzerland). The goal of this novel device is to reduce medial compartment loading without significantly affecting the loading of the lateral compartment. In this context, the current authors present a case of device failure using these new implants, which at 7 months post-op necessitated revision surgery with complete removal of the device.


Asunto(s)
Osteoartritis de la Rodilla/cirugía , Prótesis e Implantes , Falla de Prótesis , Anciano , Femenino , Humanos , Procedimientos Ortopédicos/métodos , Diseño de Prótesis
16.
Hip Int ; 23(4): 359-65, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23813166

RESUMEN

INTRODUCTION: Acetabular revision with associated bone loss in uncontained defects can be difficult. We report preliminary results utilising a novel technique, combining tantalum-augments with allograft bone and cemented cups. PATIENTS AND METHODS: Forty-six patients undergoing cup revision with a tantalum augment and allografting were clinically (HHS) and radiographically reviewed at an average of 46 months postoperatively. There were 28 type-2B and 18 type-3A Paprosky defects. Postoperative images were assessed for osteointegration, bone-remodelling and recreation of the native hip centre. RESULTS: The average patient age at time of acetabular revision was 65 years, with 18 male and 28 female patients. The HHS improved on average from 44 to 82 points. Correction of the high hip centre was possible in all patients with average medialisation of 10 mm and lowering of the hip centre by 14 mm. Four patients (four hips) sustained a hip dislocation postoperatively and one required revision. Two acetabular revisions were necessary after implantation, because of early cup loosening and failure of the construct. In one of these, the tantalum augment was found to be well fixed. Of the remaining hips, at latest radiographic follow-up, 44 tantalum implants were radiographically stable and osteointegrated. Non-progressive radiolucent lines were present around the acetabular component in two other hips. CONCLUSION: The combination of tantalum-augmentation with impaction allografting is a promising technique to manage severe uncontained acetabular defects.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Trasplante Óseo , Prótesis de Cadera , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Reoperación/estadística & datos numéricos , Tantalio
17.
Int Orthop ; 37(9): 1789-94, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23846957

RESUMEN

INTRODUCTION: Total ankle arthroplasty is increasingly used as an alternative to arthrodesis to treat advanced ankle arthritis. However, the outcomes and postoperative complications are poorly described. PATIENTS AND METHODS: Between March 2005 and May 2010 114 S.T.A.R. prostheses were implanted by one surgeon at our institution. We retrospectively analysed the demographics, clinical outcomes and radiographic characteristics of 100 ankle prostheses (97 patients). RESULTS: The average follow up was 36 months. The average preoperative AOFAS score of 36.87 (22-58) significantly increased to 75.99 postoperative. A total of 87 % of the patients reported a better life quality. Twenty-seven ankles incurred complications after primary surgery, and 21 prostheses required revision surgery, including four patients who required arthrodesis. CONCLUSION: Our study shows a high satisfaction rate after total ankle replacement and clear pain relief. Patients with a body mass Index higher than 30 showed a higher rate of complications. Compared with ankle fusion, the rates of complications are comparable.


Asunto(s)
Articulación del Tobillo/cirugía , Artritis/cirugía , Artroplastia de Reemplazo de Tobillo/efectos adversos , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Prótesis Articulares/efectos adversos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Falla de Prótesis , Estudios Retrospectivos , Factores de Riesgo
18.
Open Orthop J ; 7: 158-62, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23730379

RESUMEN

BACKGROUND: Total hip arthroplasty (THA) in patients with a history of Slipped Capital Femoral Epiphysis (SCFE), is typically indicated to address the consequent deformity of the proximal femur and/or acetabulum. It can be a challenging procedure for the orthopaedic surgeon. Previous studies have focused on prevention of osteoarthritis post-SCFE. However, there is a paucity of data on the outcomes of total hip arthroplasty in patients with osteoarthritis secondary to SCFE. This study was performed to assess the mid-term results of total hip arthroplasty in this patient cohort. MATERIALS AND METHODS: All patients with secondary osteoarthritis due to slipped capital femoral epiphysis, treated with total hip arthroplasty between 1987 and 2005, were included in this retrospective study (n=30). Thirty patients (17 male, 13 female) met the inclusion criteria with one patient lost to follow-up and one unrelated death one year before follow up examination, thereby leaving 28 patients (32 hips) eligible for the study with a mean follow-up time period of 11.2 years. The Harris Hip Score (HHS) and MOS 36 short form health survey (SF36) were determined preoperatively and at most recent follow-up for all patients. Complications were also noted for all cases. RESULTS: The mean Harris Hip Score increased significantly from 47 (32-59; SD=8.3) to 92.3 (65-100; SD=8.2) (p<0.0001). The SF-36 health survey showed an improvement of quality-of-life in all sub-scales. Overall, revision surgery was required in six cases (19 %). Aseptic loosening, leading to implant removal, was noted in five cases. A single-stage revision to address infection was performed in one case. The cumulative survival rate at latest follow-up was 81 %. No other complications were encountered during the study. CONCLUSIONS: Despite a higher failure rate, compared to total hip arthroplasty in the treatment of primary osteoarthritis, total hip arthroplasty can be considered a feasible option for patients with secondary osteoarthritis of the hip due to slipped capital femoral epiphysis. The current study demonstrates good outcomes in patients treated with a cementless column-preserving prosthesis, which is of particular relevance for this young patient cohort. However, further clinical prospective randomized studies are warranted to provide more definitive evidence.

19.
Open Orthop J ; 7: 169-71, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23730381

RESUMEN

BACKGROUND AND PURPOSE: Total hip arthroplasty (THA) is a safe and reliable surgical procedure. However, THA also has intra- and postoperative complications. A dreaded and frustrating intraoperative complication during total hip arthroplasty is dislocation of the femoral trial head from the neck into the pelvis. METHODS: Here, we report on the case of a 71-year old female patient with osteoarthritis of the left hip. Total hip arthroplasty was performed in a lateral position through a standard posterior approach. During intraoperative trial reduction, the femoral trial head dissociated from the taper and dislocated into the psoas compartment. Several unsuccessful attempts, including an additional ventral approach, were made to immediately retrieve the femoral trial head. RESULTS AND INTERPRETATION: Postoperative a Computerized Tomography (CT) was performed to locate the trial head, a secondary explorative laparotomy was undertaken to retrieve it. The retrieval of the femoral trial head should be performed in a planned second surgical procedure to avoid possible complications during the manipulation necessary for retrieval.

20.
Acta Orthop ; 84(4): 387-91, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23799350

RESUMEN

BACKGROUND AND PURPOSE: Substantial bone loss in revision total knee arthroplasty (TKA) is a challenging problem. We studied whether impaction bone grafting provides long-term restoration of bone stock in the treatment of major bone defects in revision surgery of rotational and hinged knee arthroplasties (LINK Endo-Model). PATIENTS AND METHODS: Between 1996 and 2006, 29 knees in 29 patients underwent revision procedures of rotational and hinged knee arthroplasties using impaction bone grafting (IBG) to reconstruct major bone defects. At the latest follow-up, the clinical examination included the Knee Society score (KSS), standardized radiographs, and a questionnaire for the WOMAC score. RESULTS: After a mean follow-up of 10 (6-13) years, 14 knees with 19 IBG reconstructions (5 total, 9 partial revisions) had failed. 12 knees were treated with re-revision surgery mean 5 (1-12) years after the first revision, due to mechanical failure and aseptic loosening of the components. In all these failed cases, the surgeon observed a lack of incorporation with bone graft resorption in the femur or tibia during the re-revision procedure. In all 15 knees that were not re-revised, with 21 reconstructions (6 total, 9 partial revisions), an improvement in the combined KSS score (knee score + function score) of 60 points (p < 0.001) was found at the latest follow-up. In 12 of these knees, a clear incorporation with no visible radiolucent lines around the component and no sign of substantial graft resorption was noted, while unclear radiographic graft incorporation was seen in 3 knees. INTERPRETATION: Our results clearly indicate that IBG alone is not a methodologically sound technique in the revision of rotational and hinged knee arthroplasties.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Trasplante Óseo/métodos , Articulación de la Rodilla/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Persona de Mediana Edad , Radiografía , Reoperación , Análisis de Supervivencia , Insuficiencia del Tratamiento , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...