Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Med J (Ft Sam Houst Tex) ; (PB 8-21-07/08/09): 36-43, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34449859

RESUMEN

BACKGROUND: Extended Focused Assessment with Ultrasonography in Trauma (eFAST) reliably identifies noncompressible torso hemorrhage (NCTH), a major cause of battlefield death. Increased portability of ultrasound enables eFAST far forward on the battlefield, and published data demonstrate combat medics can learn and reliably perform ultrasound exams. One medical company developed an ultrasound device with an intuitive graphical user interface (GUI) and novel, finger-worn transducer with built-in linear and phased arrays, referred to as the novel device. We evaluated combat medic eFAST performance between the novel and conventional device. METHODS: This was a prospective, randomized, crossover trial completed at a single US military installation. Subjects were US Army combat medics with no previous ultrasound experience. Subjects performed an eFAST on a live human and a simulation model with both devices after a brief training intervention. Our primary outcome was time in seconds for eFAST completion, limited to 600 seconds. Secondary outcomes included diagnostic accuracy, technical adequacy using a validated task-specific checklist, and end-user appraisal of device ease-of-use with 5-point Likert items. This study was approved by the local institutional review board. RESULTS: Forty subjects volunteered, most were male (67.5%), less than 36 years old (95.0%), and grade E-4 or below (75.0%). Subjects performed a total of 160 eFAST scans (80 novel, 80 conventional). We found no significant difference in time for eFAST completion between the novel and conventional devices (391 seconds [95% CI 364, 417] versus 352 seconds [95% CI 325, 379]; p = 0.71). We also found no significant differences between the novel and conventional devices with respect to diagnostic accuracy (91.5% versus 89.2%; p = 0.28) and technical adequacy (75.0% versus 72.5%; p = 0.28). However, we did find that subjects favored the image quality of the novel device (4.3 versus 3.6; p is less than 0.01), while favoring the conventional transducer (3.8 versus 4.3; p = 0.04). CONCLUSION: Combat medic eFAST performance utilizing both devices did not differ with respect to time to completion, diagnostic accuracy, and technical adequacy. Medics with limited ultrasound experience performed diagnostically accurate eFAST after a brief training intervention. Future research should assess learning gaps and skill retention in order to guide development of US military ultrasound training programs for combat medics.


Asunto(s)
Personal Militar , Adulto , Estudios Cruzados , Humanos , Masculino , Estudios Prospectivos , Transductores , Ultrasonografía
2.
Mil Med ; 185(9-10): e1810-e1816, 2020 09 18.
Artículo en Inglés | MEDLINE | ID: mdl-32699906

RESUMEN

INTRODUCTION: Hemorrhage is the leading cause of preventable death on the battlefield, and hemostasis is particularly challenging to achieve at junctional sites such as the axillary or inguinal regions. Mission-oriented protective posture (MOPP) gear, as worn most recently in Syria to guard against chemical weapons, can make the performance of technical skills more challenging still. The objective of this study was to evaluate how wearing MOPP gear affects the application time of the SAM Medical Junctional Tourniquet (SJT) by U.S. Army combat medics. MATERIALS AND METHODS: We conducted a prospective, randomized control trial evaluating time for SJT application between participants wearing MOPP versus those not wearing MOPP. Secondary outcomes included SJT application success rate and participant appraisal of SJT application difficulty assessed with five-point Likert items, between groups. Participants placed SJTs on robotic simulation mannequins with a penetrating inguinal injury. RESULTS: In April 2019, we enrolled 49 combat medics. Most participants were male (77.5%), had a median age of 25 (interquartile range 23-28), and in the grade of E4 or less (63.3%). Mean SJT application times in seconds were higher among those wearing MOPP versus those who were not (223.1 versus 167.2; 95% confidence interval for difference in means 5.293, 106.374; P = 0.03). Participants wearing MOPP had a less successful application rate overall, but this difference was not statistically significant (64.3% versus 81.0%, P = 0.34). Compared to participants not wearing MOPP, those wearing MOPP agreed that SJT application was difficult (4 versus 3, P = 0.03), what they were wearing affected SJT application (4 versus 2, P = 0.01), and it was difficult to use their hands during SJT application (4 versus 1, P < 0.001). CONCLUSIONS: Wearing military MOPP gear significantly prolongs the amount of time required for combat medics to apply an SJT on a simulated casualty with a penetrating inguinal injury. This study highlights the importance of incorporating MOPP gear into medical training scenarios to improve skills competency while wearing these protective garments.


Asunto(s)
Torniquetes , Ingle , Humanos , Masculino , Postura , Estudios Prospectivos , Siria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...