Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
2.
Cell Rep Methods ; 2(5): 100220, 2022 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-35637912

RESUMEN

We present a bimodal endocytic tracer, fluorescent BSA-gold (fBSA-Au), as a fiducial marker for 2D and 3D correlative light and electron microscopy (CLEM) applications. fBSA-Au consists of colloidal gold (Au) particles stabilized with fluorescent BSA. The conjugate is efficiently endocytosed and distributed throughout the 3D endolysosomal network of cells and has an excellent visibility in both fluorescence microscopy (FM) and electron microscopy (EM). We demonstrate that fBSA-Au facilitates rapid registration in several 2D and 3D CLEM applications using Tokuyasu cryosections, resin-embedded material, and cryoelectron microscopy (cryo-EM). Endocytosed fBSA-Au benefits from a homogeneous 3D distribution throughout the endosomal system within the cell, does not obscure any cellular ultrastructure, and enables accurate (50-150 nm) correlation of fluorescence to EM data. The broad applicability and visibility in both modalities makes fBSA-Au an excellent endocytic fiducial marker for 2D and 3D (cryo)CLEM applications.


Asunto(s)
Crioultramicrotomía , Microscopía por Crioelectrón/métodos , Microscopía Electrónica , Microscopía Fluorescente/métodos , Crioultramicrotomía/métodos
3.
Front Cell Dev Biol ; 10: 829545, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35478966

RESUMEN

Intracellular processes depend on a strict spatial and temporal organization of proteins and organelles. Therefore, directly linking molecular to nanoscale ultrastructural information is crucial in understanding cellular physiology. Volume or three-dimensional (3D) correlative light and electron microscopy (volume-CLEM) holds unique potential to explore cellular physiology at high-resolution ultrastructural detail across cell volumes. However, the application of volume-CLEM is hampered by limitations in throughput and 3D correlation efficiency. In order to address these limitations, we describe a novel pipeline for volume-CLEM that provides high-precision (<100 nm) registration between 3D fluorescence microscopy (FM) and 3D electron microscopy (EM) datasets with significantly increased throughput. Using multi-modal fiducial nanoparticles that remain fluorescent in epoxy resins and a 3D confocal fluorescence microscope integrated into a Focused Ion Beam Scanning Electron Microscope (FIB.SEM), our approach uses FM to target extremely small volumes of even single organelles for imaging in volume EM and obviates the need for post-correlation of big 3D datasets. We extend our targeted volume-CLEM approach to include live-cell imaging, adding information on the motility of intracellular membranes selected for volume-CLEM. We demonstrate the power of our approach by targeted imaging of rare and transient contact sites between the endoplasmic reticulum (ER) and lysosomes within hours rather than days. Our data suggest that extensive ER-lysosome and mitochondria-lysosome interactions restrict lysosome motility, highlighting the unique capabilities of our integrated CLEM pipeline for linking molecular dynamic data to high-resolution ultrastructural detail in 3D.

5.
Evol Appl ; 14(9): 2221-2230, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34603494

RESUMEN

Understanding population connectivity within a species as well as potential interactions with its close relatives is crucial to define management units and to derive efficient management actions. However, although genetics can reveal mismatches between biological and management units and other relevant but hidden information such as species misidentification or hybridization, the uptake of genetic methods by the fisheries management process is far from having been consolidated. Here, we have assessed the power of genetics to better understand the population connectivity of white (Lophius piscatorius) and its interaction with its sister species, the black anglerfish (Lophius budegassa). Our analyses, based on thousands of genome-wide single nucleotide polymorphisms, show three findings that are crucial for white anglerfish management. We found (i) that white anglerfish is likely composed of a single panmictic population throughout the Northeast Atlantic, challenging the three-stock based management, (ii) that a fraction of specimens classified as white anglerfish using morphological characteristics are genetically identified as black anglerfish (L. budegassa), and iii) that the two Lophius species naturally hybridize leading to a population of hybrids of up to 20% in certain areas. Our results set the basics for a genetics-informed white anglerfish assessment framework that accounts for stock connectivity, revises and establishes new diagnostic characters for Lophius species identification, and evaluates the effect of hybrids in the current and future assessments of the white anglerfish. Furthermore, our study contributes to provide additional evidence of the potentially negative consequences of ignoring genetic data for assessing fisheries resources.

7.
Commun Biol ; 4(1): 909, 2021 07 23.
Artículo en Inglés | MEDLINE | ID: mdl-34302049

RESUMEN

Multiple samples are required to monitor and optimize the quality and reliability of quantitative measurements of stimulated emission depletion (STED) and confocal microscopes. Here, we present a single sample to calibrate these microscopes, align their laser beams and measure their point spread function (PSF) in 3D. The sample is composed of a refractive index matched colloidal crystal of silica beads with fluorescent and gold cores. The microscopes can be calibrated in three dimensions using the periodicity of the crystal; the alignment of the laser beams can be checked using the reflection of the gold cores; and the PSF can be measured at multiple positions and depths using the fluorescent cores. It is demonstrated how this sample can be used to visualize and improve the quality of STED and confocal microscopy images. The sample is adjustable to meet the requirements of different NA objectives and microscopy techniques and additionally can be used to evaluate refractive index mismatches as a function of depth quantitatively.


Asunto(s)
Microscopía/normas , Control de Calidad , Calibración , Microscopía Confocal/normas , Reproducibilidad de los Resultados
8.
Methods Cell Biol ; 162: 171-203, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33707012

RESUMEN

The application of both fluorescence and electron microscopy results in a powerful combination of imaging modalities called "correlative light and electron microscopy" (CLEM). Whereas conventional transmission electron microscopy (TEM) tomography is only able to image sections up to a thickness of ~300nm, scanning transmission electron microscopy (STEM) tomography at 200kV allows the analysis of sections up to a thickness of 900nm in three dimensions. In the current study we have successfully integrated STEM tomography into CLEM as demonstrated for human retinal pigment epithelial 1 (RPE1) cells expressing various fluorescent fusion proteins which were high-pressure frozen and then embedded in Lowicryl HM20. Fluorescently labeled gold nanoparticles were applied onto resin sections and imaged by fluorescence and electron microscopy. STEM tomograms were recorded at regions of interest, and overlays were generated using the eC-CLEM software package. Through the nuclear staining of living cells, the use of fluorescently labeled gold fiducials for the generation of overlays, and the integration of STEM tomography we have markedly extended the application of the Kukulski protocol (Kukulski et al., 2011, 2012). Various fluorescently tagged proteins localizing to different cellular organelles could be assigned to their ultrastructural compartments. By combining STEM tomography with on-section CLEM, fluorescently tagged proteins can be localized in three-dimensional ultrastructural environments with a volume of at least 2.7×2.7×0.5µm.


Asunto(s)
Tomografía con Microscopio Electrónico , Nanopartículas del Metal , Oro , Humanos , Microscopía Electrónica , Microscopía Fluorescente
9.
Chem Mater ; 33(1): 102-116, 2021 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-33456135

RESUMEN

Colloidal copper(I) sulfide (Cu2-x S) nanocrystals (NCs) have attracted much attention for a wide range of applications because of their unique optoelectronic properties, driving scientists to explore the potential of using Cu2-x S NCs as seeds in the synthesis of heteronanocrystals to achieve new multifunctional materials. Herein, we developed a multistep synthesis strategy toward Cu2-x S/ZnS heteronanorods. The Janus-type Cu2-x S/ZnS heteronanorods are obtained by the injection of hexagonal high-chalcocite Cu2-x S seed NCs in a hot zinc oleate solution in the presence of suitable surfactants, 20 s after the injection of sulfur precursors. The Cu2-x S seed NCs undergo rapid aggregation and coalescence in the first few seconds after the injection, forming larger NCs that act as the effective seeds for heteronucleation and growth of ZnS. The ZnS heteronucleation occurs on a single (100) facet of the Cu2-x S seed NCs and is followed by fast anisotropic growth along a direction that is perpendicular to the c-axis, thus leading to Cu2-x S/ZnS Janus-type heteronanorods with a sharp heterointerface. Interestingly, the high-chalcocite crystal structure of the injected Cu2-x S seed NCs is preserved in the Cu2-x S segments of the heteronanorods because of the high-thermodynamic stability of this Cu2-x S phase. The Cu2-x S/ZnS heteronanorods are subsequently converted into single-component Cu2-x S and CuInS2 nanorods by postsynthetic topotactic cation exchange. This work expands the possibilities for the rational synthesis of colloidal multicomponent heteronanorods by allowing the design principles of postsynthetic heteroepitaxial seeded growth and nanoscale cation exchange to be combined, yielding access to a plethora of multicomponent heteronanorods with diameters in the quantum confinement regime.

10.
Ultramicroscopy ; 215: 113007, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32470633

RESUMEN

In correlative light and electron microscopy (CLEM), the capabilities of fluorescence microscopy (FM) and electron microscopy (EM) are united. FM combines a large field of view with high sensitivity for detecting fluorescence, which makes it an excellent tool for identifying regions of interest. EM has a much smaller field of view but offers superb resolution that allows studying cellular ultrastructure. In CLEM, the potentials of both techniques are combined but a limiting factor is the large difference in resolution between the two imaging modalities. Adding super resolution FM to CLEM reduces the resolution gap between FM and EM; it offers the possibility of identifying multiple targets within the diffraction limit and can increase correlation accuracy. CLEM is usually carried out in two separate setups, which requires transfer of the sample. This may result in distortion and damage of the specimen, which can complicate finding back regions of interest. By integrating the two imaging modalities, such problems can be avoided. Here, an integrated super resolution correlative microscopy approach is presented based on a wide-field super resolution FM integrated in a Transmission Electron Microscope (TEM). Switching imaging modalities is accomplished by rotation of the TEM sample holder. First imaging experiments are presented on sections of Lowicryl embedded Human Umbilical Vein Endothelial Cells labeled for Caveolin both with Protein A-Gold, and Alexa Fluor®647. TEM and FM images were overlaid using fiducial markers visible in both imaging modalities with an overlay accuracy of 28 ± 11 nm. This is close to the optical resolution of ~50 nm.


Asunto(s)
Células Endoteliales de la Vena Umbilical Humana/ultraestructura , Microscopía Electrónica de Transmisión/métodos , Microscopía Fluorescente/métodos , Imagen Individual de Molécula/métodos , Proteínas Bacterianas , Carbocianinas/química , Diseño de Equipo , Fluorescencia , Oro Coloide , Humanos , Proteínas Luminiscentes/análisis , Microscopía Electrónica de Transmisión/instrumentación , Microscopía Fluorescente/instrumentación , Imagen Individual de Molécula/instrumentación
11.
Nanoscale ; 11(12): 5304-5316, 2019 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-30843546

RESUMEN

Insight in the structure of nanoparticle assemblies up to a single particle level is key to understand the collective properties of these assemblies, which critically depend on the individual particle positions and orientations. However, the characterization of large, micron sized assemblies containing small, 10-500 nanometer, sized colloids is highly challenging and cannot easily be done with the conventional light, electron or X-ray microscopy techniques. Here, we demonstrate that focused ion beam-scanning electron microscopy (FIB-SEM) tomography in combination with image processing enables quantitative real-space studies of ordered and disordered particle assemblies too large for conventional transmission electron tomography, containing particles too small for confocal microscopy. First, we demonstrate the high resolution structural analysis of spherical nanoparticle assemblies, containing small anisotropic gold nanoparticles. Herein, FIB-SEM tomography allows the characterization of assembly dimensions which are inaccessible to conventional transmission electron microscopy. Next, we show that FIB-SEM tomography is capable of characterizing much larger ordered and disordered assemblies containing silica colloids with a diameter close to the resolution limit of confocal microscopes. We determined both the position and the orientation of each individual (nano)particle in the assemblies by using recently developed particle tracking routines. Such high precision structural information is essential in the understanding and design of the collective properties of new nanoparticle based materials and processes.

12.
Sci Rep ; 9(1): 3211, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30824844

RESUMEN

Fluorescence microscopy (FM) and electron microscopy (EM) are complementary techniques. FM affords examination of large fields of view and identifying regions of interest but has a low resolution. EM exhibits excellent resolution over a limited field of view. The combination of these two techniques, correlative microscopy, received considerable interest in the past years and has proven its potential in biology and material science. Accurate correlation of FM and EM images is, however, challenging due to the differences in contrast mechanism, size of field of view and resolution. We report an accurate, fast and robust method to correlate FM and EM images using low densities of fiducial markers. Here, 120 nm diameter fiducial markers consisting of fluorescently labelled silica coated gold nanoparticles are used. The method relies on recording FM, low magnification EM and high magnification EM images. Two linear transformation matrices are constructed, FM to low magnification EM and low magnification EM to high magnification EM. Combination of these matrices results in a high accuracy transformation of FM to high magnification EM coordinates. The method was tested using two different transmission electron microscopes and different Tokuyasu and Lowicryl sections. The overall accuracy of the correlation method is high, 5-30 nm.

13.
Proc Natl Acad Sci U S A ; 115(43): E10275-E10282, 2018 10 23.
Artículo en Inglés | MEDLINE | ID: mdl-30297399

RESUMEN

Bottom trawlers land around 19 million tons of fish and invertebrates annually, almost one-quarter of wild marine landings. The extent of bottom trawling footprint (seabed area trawled at least once in a specified region and time period) is often contested but poorly described. We quantify footprints using high-resolution satellite vessel monitoring system (VMS) and logbook data on 24 continental shelves and slopes to 1,000-m depth over at least 2 years. Trawling footprint varied markedly among regions: from <10% of seabed area in Australian and New Zealand waters, the Aleutian Islands, East Bering Sea, South Chile, and Gulf of Alaska to >50% in some European seas. Overall, 14% of the 7.8 million-km2 study area was trawled, and 86% was not trawled. Trawling activity was aggregated; the most intensively trawled areas accounting for 90% of activity comprised 77% of footprint on average. Regional swept area ratio (SAR; ratio of total swept area trawled annually to total area of region, a metric of trawling intensity) and footprint area were related, providing an approach to estimate regional trawling footprints when high-resolution spatial data are unavailable. If SAR was ≤0.1, as in 8 of 24 regions, there was >95% probability that >90% of seabed was not trawled. If SAR was 7.9, equal to the highest SAR recorded, there was >95% probability that >70% of seabed was trawled. Footprints were smaller and SAR was ≤0.25 in regions where fishing rates consistently met international sustainability benchmarks for fish stocks, implying collateral environmental benefits from sustainable fishing.


Asunto(s)
Explotaciones Pesqueras/estadística & datos numéricos , Alaska , Animales , Australia , Biodiversidad , Chile , Ecosistema , Invertebrados/fisiología , Nueva Zelanda , Océanos y Mares , Alimentos Marinos/estadística & datos numéricos
14.
Sci Rep ; 8(1): 13625, 2018 09 11.
Artículo en Inglés | MEDLINE | ID: mdl-30206379

RESUMEN

In this work, gold nanoparticles coated with a fluorescently labelled (rhodamine B) silica shell are presented as fiducial markers for correlative light and electron microscopy (CLEM). The synthesis of the particles is optimized to obtain homogeneous, spherical core-shell particles of arbitrary size. Next, particles labelled with different fluorophore densities are characterized to determine under which conditions bright and (photo)stable particles can be obtained. 2 and 3D CLEM examples are presented where optimized particles are used for correlation. In the 2D example, fiducials are added to a cryosection of cells whereas in the 3D example cells are imaged after endocytosis of the fiducials. Both examples demonstrate that the particles are clearly visible in both modalities and can be used for correlation. Additionally, the recognizable core-shell structure of the fiducials proves to be very powerful in electron microscopy: it makes it possible to irrefutably identify the particles and makes it easy to accurately determine the center of the fiducials.

15.
ACS Nano ; 12(8): 8350-8361, 2018 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-30085648

RESUMEN

The knowledge of the quantum dot (QD) concentration in a colloidal suspension and the quantitative understanding of the size-dependence of the band gap of QDs are of crucial importance from both applied and fundamental viewpoints. In this work, we investigate the size-dependence of the optical properties of nearly spherical wurtzite (wz) CuInS2 (CIS) QDs in the 2.7 to 6.1 nm diameter range (polydispersity ≤10%). The QDs are synthesized by partial Cu+ for In3+ cation exchange in template Cu2- xS nanocrystals, which yields CIS QDs with very small composition variations (In/Cu = 0.91 ± 0.11), regardless of their sizes. These well-defined QDs are used to investigate the size-dependence of the band gap of wz CIS QDs. A sizing curve is also constructed for chalcopyrite CIS QDs by collecting and reanalyzing literature data. We observe that both sizing curves follow primarily a 1/ d dependence. Moreover, the molar absorption coefficients and the absorption cross-section per CIS formula unit, both at 3.1 eV and at the band gap, are analyzed. The results demonstrate that the molar absorption coefficients of CIS QDs follow a power law at the first exciton transition energy (ε E1 = 5208 d2.45) and scale with the QD volume at 3.1 eV. This latter observation implies that the absorption cross-section per unit cell at 3.1 eV is size-independent and therefore can be estimated from bulk optical constants. These results also demonstrate that the molar absorption coefficients at 3.1 eV are more reliable for analytical purposes, since they are less sensitive to size and shape dispersion.

16.
J Phys Chem C Nanomater Interfaces ; 122(7): 3985-3993, 2018 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-29910843

RESUMEN

The localized inner 4f shell transitions of lanthanide ions are largely independent of the local surroundings. The luminescence properties of Ln3+ ions doped into nanocrystals (NCs) are therefore similar to those in bulk crystals. Quantum size effects, responsible for the unique size-dependent luminescence of semiconductor NCs, are generally assumed not to influence the optical properties of Ln3+-doped insulator NCs. However, phonon confinement effects have been reported to hamper relaxation between closely spaced Stark levels in Ln3+-doped NCs. At cryogenic temperatures emission and excitation from higher Stark levels was observed for Ln3+ ions in NCs only and were explained by a cutoff in the acoustic phonon spectrum. Relaxation would be inhibited as no resonant low energy (long wavelength) acoustic phonon modes can exist in nanometer sized crystals, and this prevents relaxation by direct phonon emission between closely spaced Stark levels. This phenomenon is known as a phonon bottleneck. Here, we investigate the role of phonon confinement in Ln-doped NCs. High resolution emission spectra at temperatures down to 2.2 K are reported for various Ln3+ ions (Er3+, Yb3+, Eu3+) doped into monodisperse 10 nm NaYF4 NCs and compared with spectra for bulk (microcrystalline) material. Contrary to previous reports, we find no evidence for phonon bottleneck effects in the emission spectra. Emission from closely spaced higher Stark levels is observed only at high excitation powers and is explained by laser heating. The present results indicate that previously reported effects in NCs may not be caused by phonon confinement.

17.
J Am Chem Soc ; 140(17): 5755-5763, 2018 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-29569443

RESUMEN

Synthesis protocols for anisotropic CuInX2 (X = S, Se, Te)-based heteronanocrystals (HNCs) are scarce due to the difficulty in balancing the reactivities of multiple precursors and the high solid-state diffusion rates of the cations involved in the CuInX2 lattice. In this work, we report a multistep seeded growth synthesis protocol that yields colloidal wurtzite CuInS2/ZnS dot core/rod shell HNCs with photoluminescence in the NIR (∼800 nm). The wurtzite CuInS2 NCs used as seeds are obtained by topotactic partial Cu+ for In3+ cation exchange in template Cu2- xS NCs. The seed NCs are injected in a hot solution of zinc oleate and hexadecylamine in octadecene, 20 s after the injection of sulfur in octadecene. This results in heteroepitaxial growth of wurtzite ZnS primarily on the Sulfur-terminated polar facet of the CuInS2 seed NCs, the other facets being overcoated only by a thin (∼1 monolayer) shell. The fast (∼21 nm/min) asymmetric axial growth of the nanorod proceeds by addition of [ZnS] monomer units, so that the polarity of the terminal (002) facet is preserved throughout the growth. The delayed injection of the CuInS2 seed NCs is crucial to allow the concentration of [ZnS] monomers to build up, thereby maximizing the anisotropic heteroepitaxial growth rates while minimizing the rates of competing processes (etching, cation exchange, alloying). Nevertheless, a mild etching still occurred, likely prior to the onset of heteroepitaxial overgrowth, shrinking the core size from 5.5 to ∼4 nm. The insights provided by this work open up new possibilities in designing multifunctional Cu-chalcogenide based colloidal heteronanocrystals.

18.
Traffic ; 19(5): 354-369, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29451726

RESUMEN

Live-cell correlative light-electron microscopy (live-cell-CLEM) integrates live movies with the corresponding electron microscopy (EM) image, but a major challenge is to relate the dynamic characteristics of single organelles to their 3-dimensional (3D) ultrastructure. Here, we introduce focused ion beam scanning electron microscopy (FIB-SEM) in a modular live-cell-CLEM pipeline for a single organelle CLEM. We transfected cells with lysosomal-associated membrane protein 1-green fluorescent protein (LAMP-1-GFP), analyzed the dynamics of individual GFP-positive spots, and correlated these to their corresponding fine-architecture and immediate cellular environment. By FIB-SEM we quantitatively assessed morphological characteristics, like number of intraluminal vesicles and contact sites with endoplasmic reticulum and mitochondria. Hence, we present a novel way to integrate multiple parameters of subcellular dynamics and architecture onto a single organelle, which is relevant to address biological questions related to membrane trafficking, organelle biogenesis and positioning. Furthermore, by using CLEM to select regions of interest, our method allows for targeted FIB-SEM, which significantly reduces time required for image acquisition and data processing.


Asunto(s)
Lisosomas/ultraestructura , Biogénesis de Organelos , Tomografía con Microscopio Electrónico/métodos , Células HeLa , Humanos , Proteínas de Membrana de los Lisosomas/metabolismo , Lisosomas/metabolismo , Imagen Óptica/métodos
19.
Angew Chem Int Ed Engl ; 57(1): 257-261, 2018 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-29119721

RESUMEN

Establishing structure-activity relationships in complex, hierarchically structured nanomaterials, such as fluid catalytic cracking (FCC) catalysts, requires characterization with complementary, correlated analysis techniques. An integrated setup has been developed to perform transmission electron microscopy (TEM) and single-molecule fluorescence (SMF) microscopy on such nanostructured samples. Correlated structure-reactivity information was obtained for 100 nm thin, microtomed sections of a single FCC catalyst particle using this novel SMF-TEM high-resolution combination. High reactivity in a thiophene oligomerization probe reaction correlated well with TEM-derived zeolite locations, while matrix components, such as clay and amorphous binder material, were found not to display activity. Differences in fluorescence intensity were also observed within and between distinct zeolite aggregate domains, indicating that not all zeolite domains are equally active.

20.
J Phys D Appl Phys ; 51(44): 443001, 2018 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-30799880

RESUMEN

Developments in microscopy have been instrumental to progress in the life sciences, and many new techniques have been introduced and led to new discoveries throughout the last century. A wide and diverse range of methodologies is now available, including electron microscopy, atomic force microscopy, magnetic resonance imaging, small-angle x-ray scattering and multiple super-resolution fluorescence techniques, and each of these methods provides valuable read-outs to meet the demands set by the samples under study. Yet, the investigation of cell development requires a multi-parametric approach to address both the structure and spatio-temporal organization of organelles, and also the transduction of chemical signals and forces involved in cell-cell interactions. Although the microscopy technologies for observing each of these characteristics are well developed, none of them can offer read-out of all characteristics simultaneously, which limits the information content of a measurement. For example, while electron microscopy is able to disclose the structural layout of cells and the macromolecular arrangement of proteins, it cannot directly follow dynamics in living cells. The latter can be achieved with fluorescence microscopy which, however, requires labelling and lacks spatial resolution. A remedy is to combine and correlate different readouts from the same specimen, which opens new avenues to understand structure-function relations in biomedical research. At the same time, such correlative approaches pose new challenges concerning sample preparation, instrument stability, region of interest retrieval, and data analysis. Because the field of correlative microscopy is relatively young, the capabilities of the various approaches have yet to be fully explored, and uncertainties remain when considering the best choice of strategy and workflow for the correlative experiment. With this in mind, the Journal of Physics D: Applied Physics presents a special roadmap on the correlative microscopy techniques, giving a comprehensive overview from various leading scientists in this field, via a collection of multiple short viewpoints.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...