Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Intensive Care Med ; 39(7): 628-635, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38190576

RESUMEN

Background: The likelihood of a patient being preload responsive-a state where the cardiac output or stroke volume (SV) increases significantly in response to preload-depends on both cardiac filling and function. This relationship is described by the canonical Frank-Starling curve. Research Question: We hypothesize that a novel method for phenotyping hypoperfused patients (ie, the "Doppler Starling curve") using synchronously measured jugular venous Doppler as a marker of central venous pressure (CVP) and corrected flow time of the carotid artery (ccFT) as a surrogate for SV will refine the pretest probability of preload responsiveness/unresponsiveness. Study Design and Methods: We retrospectively analyzed a prospectively collected convenience sample of hypoperfused adult emergency department (ED) patients. Doppler measurements were obtained before and during a preload challenge using a wireless, wearable Doppler ultrasound system. Based on internal jugular and carotid artery Doppler surrogates of CVP and SV, respectively, we placed hemodynamic assessments into quadrants (Qx) prior to preload augmentation: low CVP with normal SV (Q1), high CVP and normal SV (Q2), low CVP and low SV (Q3) and high CVP and low SV (Q4). The proportion of preload responsive and unresponsive assessments in each quadrant was calculated based on the maximal change in ccFT (ccFTΔ) during either a passive leg raise or rapid fluid challenge. Results: We analyzed 41 patients (68 hemodynamic assessments) between February and April 2021. The prevalence of each phenotype was: 15 (22%) in Q1, 8 (12%) in Q2, 39 (57%) in Q3, and 6 (9%) in Q4. Preload unresponsiveness rates were: Q1, 20%; Q2, 50%; Q3, 33%, and Q4, 67%. Interpretation: Even fluid naïve ED patients with sonographic estimates of low CVP have high rates of fluid unresponsiveness, making dynamic testing valuable to prevent ineffective IVF administration.


Asunto(s)
Arterias Carótidas , Fluidoterapia , Venas Yugulares , Ultrasonografía Doppler , Humanos , Proyectos Piloto , Masculino , Femenino , Fluidoterapia/métodos , Persona de Mediana Edad , Venas Yugulares/diagnóstico por imagen , Estudios Prospectivos , Arterias Carótidas/diagnóstico por imagen , Anciano , Resucitación/métodos , Presión Venosa Central/fisiología , Estudios Retrospectivos , Adulto , Volumen Sistólico/fisiología , Gasto Cardíaco/fisiología , Servicio de Urgencia en Hospital , Hemodinámica
2.
Ultrasound J ; 15(1): 32, 2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37505318

RESUMEN

Providing intravenous (IV) fluids to a patient with signs or symptoms of hypoperfusion is common. However, evaluating the IV fluid 'dose-response' curve of the heart is elusive. Two patients were studied in the emergency department with a wireless, wearable Doppler ultrasound system. Change in the common carotid arterial and internal jugular Doppler spectrograms were simultaneously obtained as surrogates of left ventricular stroke volume (SV) and central venous pressure (CVP), respectively. Both patients initially had low CVP jugular venous Doppler spectrograms. With preload augmentation, only one patient had arterial Doppler measures indicative of significant SV augmentation (i.e., 'fluid responsive'). The other patient manifested diminishing arterial response, suggesting depressed SV (i.e., 'fluid unresponsive') with evidence of ventricular asynchrony. In this short communication, we describe how a wireless, wearable Doppler ultrasound simultaneously tracks surrogates of cardiac preload and output within a 'Doppler Starling curve' framework; implications for IV fluid dosing are discussed.

3.
J Vis Exp ; (191)2023 01 20.
Artículo en Inglés | MEDLINE | ID: mdl-36744770

RESUMEN

A preload challenge (PC) is a clinical maneuver that, first, increases the cardiac filling (i.e., preload) and, second, calculates the change in cardiac output. Fundamentally, a PC is a bedside approach for testing the Frank-Starling-Sarnoff (i.e., "cardiac function") curve. Normally, this curve has a steep slope such that a small change in the cardiac preload generates a large change in the stroke volume (SV) or cardiac output. However, in various disease states, the slope of this relationship flattens such that increasing the volume into the heart leads to little rise in the SV. In this pathological scenario, additional cardiac preload (e.g., intravenous fluid) is unlikely to be physiologically effective and could lead to harm if organ congestion evolves. Therefore, inferring both the cardiac preload and output is clinically useful as it may guide intravenous (IV) fluid resuscitation. Accordingly, the goal of this protocol is to describe a method for contemporaneously tracking the surrogates of cardiac preload and output using a novel, wireless, wearable ultrasound during a well-validated preload challenge.


Asunto(s)
Corazón , Venas , Gasto Cardíaco/fisiología , Volumen Sistólico/fisiología , Corazón/diagnóstico por imagen , Corazón/fisiología , Ultrasonografía Doppler
4.
J Intensive Care ; 11(1): 7, 2023 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-36793079

RESUMEN

BACKGROUND: Little data exist on the time spent by emergency department (ED) personnel providing intravenous (IV) fluid to 'responsive' versus 'unresponsive' patients. METHODS: A prospective, convenience sample of adult ED patients was studied; patients were enrolled if preload expansion was indicated for any reason. Using a novel, wireless, wearable ultrasound, carotid artery Doppler was obtained before and throughout a preload challenge (PC) prior to each bag of ordered IV fluid. The treating clinician was blinded to the results of the ultrasound. IV fluid was deemed 'effective' or 'ineffective' based on the greatest change in carotid artery corrected flow time (ccFT∆) during the PC. The duration, in minutes, of each bag of IV fluid administered was recorded. RESULTS: 53 patients were recruited and 2 excluded for Doppler artifact. There were 86 total PCs included in the investigation comprising 81.7 L of administered IV fluid. 19,667 carotid Doppler cardiac cycles were analyzed. Using ccFT∆ ≥ + 7 ms to discriminate 'physiologically effective' from 'ineffective' IV fluid, we observed that 54 PCs (63%) were 'effective', comprising 51.7 L of IV fluid, whereas, 32 (37%) were 'ineffective' comprising 30 L of IV fluid. 29.75 total hours across all 51 patients were spent in the ED providing IV fluids categorized as 'ineffective.' CONCLUSIONS: We report the largest-known carotid artery Doppler analysis (i.e., roughly 20,000 cardiac cycles) in ED patients requiring IV fluid expansion. A clinically significant amount of time was spent providing physiologically ineffective IV fluid. This may represent an avenue to improve ED care efficiency.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...