Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
J Adv Nurs ; 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39046170

RESUMEN

AIM: To explore the implementation contexts and strategies that influence the uptake and selection of alternative peripherally inserted central catheter (PICC) materials and design. DESIGN: Qualitative evaluation of end user perspectives within a randomized control trial of different PICC materials and design. METHODS: Semi-structured interviews with key stakeholders were undertaken via an adapted, rapid-analytic approach using the Consolidated Framework for Implementation Research. Outcomes were mapped against the Expert Recommendations for Implementing Change (ERIC) tool for strategies to guide innovation in PICC practice. RESULTS: Participants (n = 23) represented a combination of users and inserters/purchasers, from adult and paediatric settings. Dominant themes included intervention characteristics (intervention source), inner setting (structural characteristics) and individuals involved (self-efficacy). Strategies emerging to support a change from ERIC mapping (n = 16) included promotion of intervention adaptability, inclusion of staff and consumer perspectives and sufficient funding. Implementation contexts such as inner setting and individuals involved equally impacted PICC success and implementation effectiveness and enabled a greater understanding of barriers and facilitators to intervention implementation in this trial. CONCLUSION: Trial evidence is important, but healthcare decision-making requires consideration of local contexts especially resourcing. Implementation contexts for Australian healthcare settings include a practical, strategic toolkit for the implementation of alternative PICC materials and designs. REPORTING METHOD: This study adhered to COREQ guidelines. PATIENT OR PUBLIC CONTRIBUTION: No patient or public contribution.

2.
BMJ Open ; 14(7): e085637, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38986559

RESUMEN

INTRODUCTION: Central venous access devices (CVADs) are commonly used for the treatment of paediatric cancer patients. Catheter locking is a routine intervention that prevents CVAD-associated adverse events, such as infection, occlusion and thrombosis. While laboratory and clinical data are promising, tetra-EDTA (T-EDTA) has yet to be rigorously evaluated or introduced in cancer care as a catheter lock. METHODS AND ANALYSIS: This is a protocol for a two-arm, superiority type 1 hybrid effectiveness-implementation randomised controlled trial conducted at seven hospitals across Australia and New Zealand. Randomisation will be in a 3:2 ratio between the saline (heparinised saline and normal saline) and T-EDTA groups, with randomly varied blocks of size 10 or 20 and stratification by (1) healthcare facility; (2) CVAD type and (3) duration of dwell since insertion. Within the saline group, there will be a random allocation between normal and heparin saline. Participants can be re-recruited and randomised on insertion of a new CVAD. Primary outcome for effectiveness will be a composite of CVAD-associated bloodstream infections (CABSI), CVAD-associated thrombosis or CVAD occlusion during CVAD dwell or at removal. Secondary outcomes will include CABSI, CVAD-associated-thrombosis, CVAD failure, incidental asymptomatic CVAD-associated-thrombosis, other adverse events, health-related quality of life, healthcare costs and mortality. To achieve 90% power (alpha=0.05) for the primary outcome, data from 720 recruitments are required. A mixed-methods approach will be employed to explore implementation contexts from the perspective of clinicians and healthcare purchasers. ETHICS AND DISSEMINATION: Ethics approval has been provided by Children's Health Queensland Hospital and Health Service Human Research Ethics Committee (HREC) (HREC/22/QCHQ/81744) and the University of Queensland HREC (2022/HE000196) with subsequent governance approval at all sites. Informed consent is required from the substitute decision-maker or legal guardian prior to participation. In addition, consent may also be obtained from mature minors, depending on the legislative requirements of the study site. The primary trial and substudies will be written by the investigators and published in peer-reviewed journals. The findings will also be disseminated through local health and clinical trial networks by investigators and presented at conferences. TRIAL REGISTRATION NUMBER: ACTRN12622000499785.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Catéteres Venosos Centrales , Neoplasias , Humanos , Niño , Infecciones Relacionadas con Catéteres/prevención & control , Catéteres Venosos Centrales/efectos adversos , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/métodos , Ácido Edético/uso terapéutico , Australia , Trombosis/prevención & control , Trombosis/etiología , Nueva Zelanda , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Calidad de Vida , Heparina/efectos adversos , Heparina/administración & dosificación , Heparina/uso terapéutico
3.
JAMA Pediatr ; 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39008311

RESUMEN

Importance: Catheter dislodgement is a common complication for children with tunneled or peripherally inserted noncuffed central venous catheters (CVCs). A subcutaneous anchor securement system (SASS) may reduce this risk compared with traditional adhesive securement. Objective: To compare dislodgement of noncuffed CVCs secured with SASS with dislodgement of noncuffed CVCs secured with sutureless securement devices (SSDs). Design, Setting, and Participants: The SECURED (Securing Central Venous Catheters to Prevent Dislodegment) trial was a pragmatic, multicenter, superiority randomized clinical trial with an internal pilot and was conducted from August 5, 2020, to August 30, 2022, at 2 Australian quaternary pediatric hospitals. Data analysis was performed in January 2023. Patients aged 0 to 18 years requiring a noncuffed CVC (≥3F catheter) were eligible for inclusion. Follow-up duration was 8 weeks or until device removal. Interventions: Patients were randomly assigned 1:1 to receive an SASS or SSD, stratified by hospital and catheter type. Only 1 catheter was studied per patient. Main Outcomes and Measures: The primary outcome was dislodgement (partial or total), defined as movement of the catheter tip by greater than 1 cm (change in external catheter length) at any point during catheter dwell. Dislodgement, reported as a risk ratio (RR), was estimated using a generalized linear model with binomial family and log link. Secondary outcomes were reported as incidence rate ratios and were analyzed using Poission regression. Outcomes reported as mean differences (MDs) were analyzed using linear regression. Results: Of 310 randomized patients, 175 patients (56.5%) were male and median (IQR) patient age was 48 (16-120) months. A total of 307 patients had a catheter device inserted, of which 153 (49.8%) were SASS and 154 (50.2%) were SSD, and were included in the intention-to-treat (ITT) analysis. Device dislodgement was lower with SASS (8 dislodgements in 153 patients [5.2%]) compared with SSD (35 dislodgements in 154 patients [22.7%]) (RR, 0.23; 95% CI, 0.11-0.48; P < .001). The per-protocol analysis was consistent with the ITT analysis. Partial dislodgement accounted for most dislodgement events, including 6 partial dislodgements in the SASS group (3.9%) and 30 partial dislodgements in the SSD group (19.5%) (RR, 0.18; 95% CI, 0.08-0.42). This contributed to fewer complications during dwell in the SASS group (37 reported complications [24.2%]) vs the SSD group (60 reported complications [39.0%]) (RR, 0.62; 95% CI, 0.44-0.87). Staff reported greater difficulty removing devices anchored with SASS vs SSD (mean [SD], 29.1 [31.3] vs 5.3 [17.0], respectively; MD, 23.8; 95% CI, 16.7-31.0). However, use of SASS resulted in reduced per-participant health care costs of A$36.60 (95% credible interval, 4.25-68.95; US $24.36; 95% credible interval, 2.83-45.89). Conclusions and Relevance: In the SECURED trial, noncuffed CVCs secured with SASS had fewer dislodgements compared with SSDs, with a lower cost per patient and an acceptable safety profile. Future efforts should be directed at SASS implementation at the health service level. Trial Registration: anzctr.org.au Identifier: ACTRN12620000783921.

4.
J Clin Nurs ; 33(5): 1762-1776, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38413831

RESUMEN

BACKGROUND: Healthcare consumers require diverse resources to assist their navigation of complex healthcare interactions, however, these resources need to be fit for purpose. AIM: In this study, we evaluated the utility, usability and feasibility of children, families and adults requiring long-term intravenous therapy using a recently developed mobile health application (App), intravenous (IV) Passport. DESIGN: Multi-site, parallel, multi-method, prospective cohort study. METHODS: A multi-site, multi-method study was carried out in 2020-2021, with 46 participants (20 adults, 26 children/family) reporting on their experiences surrounding the use of the IV Passport for up to 6 months. RESULTS: Overall, utility rates were acceptable, with 78.3% (N = 36) using the IV Passport over the follow-up period, with high rates of planned future use for those still active in the project (N = 21; 73%), especially in the child/family cohort (N = 13; 100%). Acceptability rates were high (9/10; IQR 6.5-10), with the IV Passport primarily used for documenting new devices and complications. Thematic analysis revealed three main themes (and multiple subthemes) in the qualitative data: Advocacy for healthcare needs, Complexity of healthcare and App design and functionality. CONCLUSION: Several recommendations were made to improve the end-user experience including 'how to' instructions; and scheduling functionality for routine care. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: The IV Passport can be safely and appropriately integrated into healthcare, to support consumers. IMPACT: Patient-/parent-reported feedback suggests the Intravenous Passport is a useful tool for record-keeping, and positive communication between patients/parents, and clinicians. REPORTING METHOD: Not applicable. PATIENT CONTRIBUTION: Consumers reported their experiences surrounding the use of the IV Passport for up to 6 months.


Asunto(s)
Telemedicina , Adulto , Niño , Humanos , Estudios Prospectivos , Telemedicina/métodos , Atención a la Salud , Padres , Comunicación
5.
Eur J Oncol Nurs ; 69: 102520, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38394934

RESUMEN

PURPOSE: Central venous access devices play a crucial role in healthcare settings. However, there is concern regarding the high incidence of blockages occurring before the completion of treatments and existing guidelines for occlusion management are not consistently followed. To explore the decision-making and problem-solving process of occlusion management and identify enablers and barriers to implementing evidence for occlusion management in pediatric cancer care. METHODS: A qualitative design with individual semi-structured interviews. Participants were selected by purposeful sampling from a tertiary-referral pediatric facility, and semi-structured interviews were conducted. RESULTS: A total of 13 clinicians and 5 parents were interviewed. The thematic analysis revealed four main decision-making/problem-solving themes: 1) clinical reasoning and judgement for central venous access devices occlusion, 2) capability in central venous access devices occlusion management, 3) colleague collaboration in the escalation process and 4) lack of adequate support to manage the occlusion. This study identified positive and negative influences on the problem-solving process, including clinicians' psychological capabilities, social and physical resources, and beliefs about consequences. CONCLUSION: This study found that clinicians in pediatric cancer care were able to manage central venous access device occlusions using clinical reasoning and judgment skills, which may conflict with evidence-based practices. The study confirmed the importance of a team approach and prior experience in managing central venous access devices in pediatric oncology settings and identified potential conflicts between clinician decisions based on the patient's current and anticipated conditions and implementation of evidence-based practice. Improving documentation and providing visual aids could benefit clinicians' problem-solving processes.


Asunto(s)
Catéteres Venosos Centrales , Neoplasias , Humanos , Niño , Catéteres Venosos Centrales/efectos adversos , Neoplasias/terapia , Oncología Médica , Investigación Cualitativa , Documentación
6.
J Pediatr Nurs ; 76: 68-75, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38364591

RESUMEN

PURPOSE: Children with chronic and complex health conditions frequently need intravenous devices. The current approach to intravenous device selection, insertion, and monitoring is inconsistent, and healthcare consumers are often negatively affected by siloed health information, and poor future planning. Despite child- and family-centred care being recognised as a pillar of paediatric nursing care, limited implementation for vascular access device planning and management is evident. DESIGN AND METHODS: To address this, we conducted a multi-phased approach to co-create, then evaluate, a mobile health (mHealth) application: IV Passport. Co-creation involved a prioritisation survey, followed by a Passport advisory panel consensus meeting. Following confirmation of the required content and features of the Passport, the mHealth application was designed and content validation achieved via survey. RESULTS: The prioritisation survey yielded recommendations for seven features (e.g., graphical presentations of current/past devices). Content for nine device types (e.g., totally implanted ports) was suggested, each with 10 related items (e.g., insertion site). Content items for device-associated complications, future vascular access plans, and educational resources were also suggested. Following design, the application was released through Apple and Android platforms; and adapted to a paper version. Content validation was established; 100% strongly agreed the application was easy to use; 80% agreed/strongly agreed that they would recommend the Passport to others. CONCLUSION: IV Passport embodies effective child- and family-centred care through consumer co-creation to empower patients and families manage vascular access devices. PRACTICE IMPLICATIONS: IV Passport remains active; and can be utilised across many healthcare settings and patient populations.


Asunto(s)
Telemedicina , Dispositivos de Acceso Vascular , Humanos , Niño , Aplicaciones Móviles , Masculino , Femenino , Enfermedad Crónica , Enfermería Pediátrica
7.
J Adv Nurs ; 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38263365

RESUMEN

AIM: This study aimed to estimate the proportion and rate of skin complications and mechanical dysfunction associated with indwelling invasive devices in paediatric healthcare. DESIGN: This systematic review is reported in accordance with Cochrane standards for randomized controlled trials and the Meta-analysis of Observation Studies in Epidemiology for cohort studies. DATA SOURCES: MEDLINE, CINAHL, Embase, Web of Science, Scopus, Cochrane CENTRAL, clinical trial registries, and unpublished study databases were searched. REVIEW METHODS: Cohort studies and trials published from January 2011 to June 2022, including (1) indwelling invasive devices, (2) paediatric participants admitted to a hospital, (3) reporting post-insertion device-associated skin complication and/or mechanical dysfunction, and (4) published in English, were included. Device-associated skin complication and mechanical dysfunction (infiltration, leakage, occlusion/blockage, dislodgement/malposition, breakage and others). Pooled proportion and incidence rate per 1000 device days are reported. RESULTS: This review synthesized 114 studies (30,782 devices; 1,635,649 device-days). Skin complications were reported in 40 studies, but none exclusively reported individual device-related pressure injuries. Mechanical dysfunctions were well-reported for central venous access devices, peripheral intravenous catheters, nasogastric/gastric tubes and peritoneal dialysis catheters but less for arterial catheters, extracorporeal membrane oxygenation and ventricular assist devices. CONCLUSIONS: This systematic review highlights the need for standardized definitions and reporting methods to better surveil and benchmark device-related complications, particularly for understudied device types. Device-related pressure injuries were not reported in any of the included studies, and all devices except for vascular access devices require standardized reporting of complications. IMPACT: Despite the widespread use of invasive devices, comprehensive data on their prevalence, utility, and associated paediatric complications is limited. This review identified prevalent skin complications, occlusions and dislodgments in children with devices, underscoring the need for standardized reporting to enhance surveillance and understanding of paediatric device-related complications. REPORTING METHOD: MOOSE (Meta-analyses Of Observational Studies in Epidemiology) Checklist. PATIENT OR PUBLIC CONTRIBUTION: No Patient or Public Contribution.

8.
Pediatr Res ; 96(1): 148-158, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38200324

RESUMEN

BACKGROUND AND AIMS: Invasive devices are widely used in healthcare settings; however, pediatric patients are especially vulnerable to invasive device-associated harm. This study aimed to explore invasive device utility, prevalence, harm, and clinical practice across three Australian pediatric tertiary hospitals. METHODS: In 2022-2023, a multi-center, observational, rolling-point-prevalence survey was conducted. Fifty-per-cent of inpatients were systemically sampled by random allocation. Patients with devices were then followed for up to 3-days for device-related complications/failures and management/removal characteristics. RESULTS: Of the 285 patients audited, 78.2% had an invasive device (n = 412 devices), with a median of 1 device-per-patient (interquartile range 1-2), with a maximum of 13 devices-per-patient. Over half of devices were vascular access devices (n = 223; 54.1%), followed by gastrointestinal devices (n = 112; 27.2%). The point-prevalence of all device complications on Day 0 was 10.7% (44/412 devices) and period-prevalence throughout the audit period was 27.7% (114/412 devices). The period-prevalence of device failure was 13.4% (55/412 devices). CONCLUSIONS: The study highlighted a high prevalence of invasive devices among hospitalized patients. One-in-ten devices failed during the audit period. These findings underscore the need for vigilant monitoring and improved strategies to minimize complications and enhance the safety of invasive devices in pediatric hospital settings. IMPACT: A high prevalence of invasive devices among hospitalized patients was reported. Of the 285 patients audited, almost 80% had an invasive device (total 412 devices), with a median of 1 device-per-patient and a maximum of 13 devices-per-patient. The most common devices used in pediatric healthcare are vascular access devices (n = 223; 54.1%), however, 16% (n = 36) of these devices failed, and one-third had complications. The point prevalence of all device complications at day 0 was 10.7% (44 out of 412 devices), with a period prevalence of 27.7% (114 out of 412 devices) throughout the audit period.


Asunto(s)
Centros de Atención Terciaria , Humanos , Niño , Masculino , Femenino , Preescolar , Prevalencia , Lactante , Australia/epidemiología , Adolescente , Falla de Equipo/estadística & datos numéricos , Dispositivos de Acceso Vascular/efectos adversos , Recién Nacido , Encuestas y Cuestionarios , Hospitales Pediátricos
9.
Pediatrics ; 153(2)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38287882

RESUMEN

CONTEXT: Central venous access device (CVAD) locks are routine interventions used to prevent and treat complications, such as infection, thrombosis, and catheter occlusion. OBJECTIVE: To compare and rank lock-solutions for prevention or treatment of complications in pediatrics. Design Systematic review and network meta-analysis. DATA SOURCES: Five databases and 2 clinical trial registries were searched. STUDY SELECTION: Published and unpublished randomized controlled trials that enrolled pediatric patients with a CVAD and compared the effectiveness of lock-solutions. DATA EXTRACTION: Data extraction was conducted by 2 reviewers. Odds ratio (OR) for prevention or treatment of CVAD-associated bloodstream infection (BSI), thrombosis, occlusion, CVAD-failure, and mortality were calculated, with point estimates ranking lock-solutions. RESULTS: Twenty-nine studies were included. Chelating agents and antibiotic locks given as prevention were associated with lower odds (OR: 0.11; 95% confidence interval [CI]: 0.02-0.67; moderate-quality; OR: 0.19; 95% CI: 0.05-0.79, high-quality, respectively) of CVAD-associated BSI compared with heparinized saline (reference). Preventative thrombolytic agents had lower odds (OR: 0.64, 95% CI: 0.44-0.93; low-quality) of CVAD occlusion, whereas ethanol had higher odds (OR: 2.84, 95% CI: 1.31-6.16; high-quality) compared with heparinized saline (reference). No lock solution had effects on thrombosis prevention or treatment, CVAD-failure, CVAD-associated BSI treatment failure, or mortality. LIMITATIONS: There was substantial uncertainty around the point estimates because of the limited number of studies for outcomes and study heterogeneity. More high-quality studies are needed to confirm the efficacy of lock solutions. CONCLUSIONS: Chelating agents and antibiotic locks may be effective for CVAD-associated BSI prevention in pediatrics. Thrombolytic agents can be an option for CVAD occlusion prevention, whereas ethanol may not be recommended.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Catéteres Venosos Centrales , Sepsis , Trombosis , Niño , Humanos , Antibacterianos , Infecciones Relacionadas con Catéteres/prevención & control , Cateterismo Venoso Central/efectos adversos , Catéteres Venosos Centrales/efectos adversos , Quelantes , Etanol , Fibrinolíticos , Metaanálisis en Red , Trombosis/etiología , Trombosis/prevención & control
10.
Hosp Pediatr ; 14(1): e25-e41, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38161187

RESUMEN

CONTEXT: The risk of invasive device-related thrombosis and bleeding contributes to morbidity and mortality, yet their prevalence by device-types is poorly understood. OBJECTIVES: This study aimed to estimate pooled proportions and rates of thrombotic and bleeding complications associated with invasive devices in pediatric health care. DATA SOURCES: Medline, CINAHL, Embase, Web of Science, Scopus, Cochrane CENTRAL, clinical trial registries, and unpublished study databases were searched. STUDY SELECTION: Cohort studies and trials published from January 2011 to June 2022, including (1) indwelling invasive devices, (2) pediatric participants admitted to a hospital, (3) reporting thrombotic and bleeding complications, and (4) published in English, were included. DATA EXTRACTION: Meta-analysis of observational studies in epidemiology guidelines for abstracting and assessing data quality and validity were used. MAIN OUTCOMES AND MEASURES: Device-specific pooled thromboses (symptomatic, asymptomatic, unspecified) and bleeding (major, minor). RESULTS: Of the 107 studies, 71 (66%) focused on central venous access devices. Symptomatic venous thromboembolism in central venous access devices was 4% (95% confidence interval [CI], 3-5; incidence rate 0.03 per 1000 device-days, 95% CI, 0.00-0.07), whereas asymptomatic was 10% (95% CI, 7-13; incidence rate 0.25 per 1000 device-days, 95% CI, 0.14-0.36). Both ventricular assist devices (28%; 95% CI, 19-39) and extracorporeal membrane oxygenation (67%; 95% CI, 52-81) were often associated with major bleeding complications. CONCLUSIONS: This comprehensive estimate of the incidence and prevalence of device-related thrombosis and bleeding complications in children can inform clinical decision-making, guide risk assessment, and surveillance.


Asunto(s)
Trombosis , Tromboembolia Venosa , Niño , Humanos , Anticoagulantes , Trombosis/epidemiología , Trombosis/etiología , Hemorragia/epidemiología , Hemorragia/etiología , Hemorragia/terapia , Atención a la Salud
11.
Hosp Pediatr ; 14(1): e42-e56, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38161188

RESUMEN

CONTEXT: Indwelling invasive devices inserted into the body for extended are associated with infections. OBJECTIVE: This study aimed to estimate infection proportion and rates associated with invasive devices in pediatric healthcare. DATA SOURCES: Medline, CINAHL, Embase, Web of Science, Scopus, Cochrane CENTRAL, clinical trial registries, and unpublished study databases were searched. STUDY SELECTION: Cohort studies and trials published from January 2011 to June 2022, including (1) indwelling invasive devices, (2) pediatric participants admitted to a hospital, (3) postinsertion infection complications, and (4) published in English, were included. DATA EXTRACTION: Meta-analysis of observational studies in epidemiology guidelines for abstracting and assessing data quality and validity were used. MAIN OUTCOMES AND MEASURES: Device local, organ, and bloodstream infection (BSIs) pooled proportion and incidence rate (IR) per-1000-device-days per device type were reported. RESULTS: A total of 116 studies (61 554 devices and 3 632 364 device-days) were included. The highest number of studies were central venous access devices associated BSI (CVAD-BSI), which had a pooled proportion of 8% (95% confidence interval [CI], 6-11; 50 studies) and IR of 0.96 per-1000-device-days (95% CI, 0.78-1.14). This was followed by ventilator-associated pneumonia in respiratory devices, which was 19% (95% CI, 14-24) and IR of 14.08 per-1000-device-days (95%CI, 10.57-17.58). CONCLUSIONS: Although CVAD-BSI and ventilator associated pneumonia are well-documented, there is a scarcity of reporting on tissue and local organ infections. Standard guidelines and compliance initiatives similar to those dedicated to CVADs should be implemented in other devices in the future.


Asunto(s)
Catéteres Venosos Centrales , Sepsis , Niño , Humanos , Incidencia
12.
JAMA Pediatr ; 177(11): 1132-1140, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37695594

RESUMEN

Importance: Peripheral intravenous catheters (PIVCs) frequently fail during treatment causing therapy interruption, pain, recatheterization, and additional health care costs. Midline catheters (MCs) may improve functional dwell time and reduce failure compared with traditional PIVCs. Objective: To compare device failure of MCs with PIVCs. Design, Setting, and Participants: This was a pragmatic, randomized clinical superiority trial with an embedded internal pilot study conducted from July 2020 to May 2022. The study took place in a quaternary pediatric hospital in Brisbane, Queensland, Australia. Inclusion criteria were patients aged 1 to 18 years requiring peripherally compatible intravenous therapy for 4 days or longer. Interventions: Patients were randomly assigned 1:1 to receive a PIVC or MC, stratified by age (≤5 years, >5 years). One catheter was studied per patient. Main Outcomes and Measures: The primary outcome was all-cause device failure, defined as premature cessation of device function. Secondary outcomes included number of insertion attempts, insertion failure, pain (on insertion), procedural time, patient/parent satisfaction (with insertion), device dwell time, device complications during dwell time, additional vascular access devices required to complete treatment, clinician satisfaction (at removal), and health care costs. Results: Of the 128 patients randomly assigned to study groups, 127 patients (median [IQR] age, 7 [2-13] years; 71 male [56%]) had a device inserted, with 65 (51.2%) in the PIVC group and 62 (48.8%) in the MC group. All patients were included in the intention-to-treat analysis. Device failure was lower in patients in the MC group (10 [16.1%]) compared with those in the PIVC group (30 [46.2%]; odds ratio [OR], 0.22; 95% CI, 0.10-0.52; P <.001). MCs were associated with fewer insertion attempts (mean difference [MD], -0.3; 95% CI, -0.5 to 0; P = .04), increased dwell time (MD, 66.9 hours; 95% CI, 36.2-97.5 hours; P <.001), and fewer patients required additional vascular access devices to complete treatment in the MC group (4 [6.5%]) and PIVC group (19 [29.2%]; OR, 0.17; 95% CI, 0.05-0.52; P = .002). Compared with PIVCs, use of MCs was associated with greater patient (9.0 vs 7.1 of 10; P = .002) and parent (9.1 vs 8.2 of 10; P = .02) satisfaction and lower health care costs (AUS -$151.67 [US -$101.13] per person; 95% credible interval, AUS -$171.45 to -$131.90 [US -$114.20 to -$87.95]). Conclusions and Relevance: Findings suggest that MC insertion for patients requiring peripherally compatible intravenous therapy for 4 days or longer should be prioritized to reduce the resource intensive, expensive, and burdensome sequelae of device failure. Trial Registration: Australia New Zealand Clinical Trials Registry, ACTRN12620000724976.


Asunto(s)
Cateterismo Periférico , Adolescente , Niño , Preescolar , Humanos , Masculino , Australia , Cateterismo Periférico/efectos adversos , Catéteres , Falla de Equipo , Dolor/etiología , Proyectos Piloto , Femenino
13.
J Immunother Cancer ; 11(6)2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37321663

RESUMEN

BACKGROUND: Locally advanced/recurrent head and neck squamous cell carcinoma (HNSCC) is associated with significant morbidity and mortality. To target upregulated ErbB dimer expression in this cancer, we developed an autologous CD28-based chimeric antigen receptor T-cell (CAR-T) approach named T4 immunotherapy. Patient-derived T-cells are engineered by retroviral transduction to coexpress a panErbB-specific CAR called T1E28ζ and an IL-4-responsive chimeric cytokine receptor, 4αß, which allows IL-4-mediated enrichment of transduced cells during manufacture. These cells elicit preclinical antitumor activity against HNSCC and other carcinomas. In this trial, we used intratumoral delivery to mitigate significant clinical risk of on-target off-tumor toxicity owing to low-level ErbB expression in healthy tissues. METHODS: We undertook a phase 1 dose-escalation 3+3 trial of intratumoral T4 immunotherapy in HNSCC (NCT01818323). CAR T-cell batches were manufactured from 40 to 130 mL of whole blood using a 2-week semiclosed process. A single CAR T-cell treatment, formulated as a fresh product in 1-4 mL of medium, was injected into one or more target lesions. Dose of CAR T-cells was escalated in 5 cohorts from 1×107-1×109 T4+ T-cells, administered without prior lymphodepletion. RESULTS: Despite baseline lymphopenia in most enrolled subjects, the target cell dose was successfully manufactured in all cases, yielding up to 7.5 billion T-cells (67.5±11.8% transduced), without any batch failures. Treatment-related adverse events were all grade 2 or less, with no dose-limiting toxicities (Common Terminology Criteria for Adverse Events V.4.0). Frequent treatment-related adverse events were tumor swelling, pain, pyrexias, chills, and fatigue. There was no evidence of leakage of T4+ T-cells into the circulation following intratumoral delivery, and injection of radiolabeled cells demonstrated intratumoral persistence. Despite rapid progression at trial entry, stabilization of disease (Response Evaluation Criteria in Solid Tumors V.1.1) was observed in 9 of 15 subjects (60%) at 6 weeks post-CAR T-cell administration. Subsequent treatment with pembrolizumab and T-VEC oncolytic virus achieved a rapid complete clinical response in one subject, which was durable for over 3 years. Median overall survival was greater than for historical controls. Disease stabilization was associated with the administration of an immunophenotypically fitter, less exhausted, T4 CAR T-cell product. CONCLUSIONS: These data demonstrate the safe intratumoral administration of T4 immunotherapy in advanced HNSCC.


Asunto(s)
Neoplasias de Cabeza y Cuello , Receptores Quiméricos de Antígenos , Humanos , Carcinoma de Células Escamosas de Cabeza y Cuello/terapia , Interleucina-4 , Recurrencia Local de Neoplasia , Inmunoterapia , Neoplasias de Cabeza y Cuello/tratamiento farmacológico
14.
EJNMMI Res ; 13(1): 44, 2023 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-37195370

RESUMEN

BACKGROUND: Myocardial programmed death-ligand 1 (PD-L1) expression is implicated in immune checkpoint inhibitor (ICI)-associated myocarditis. Measurement of myocardial PD-L1 expression may have potential use as a mechanistic and predictive biomarker. The aim of this study was to determine non-invasive assessment of myocardial PD-L1 expression using [99mTc]-labelled anti-PD-L1 single-domain antibody (NM-01) SPECT/CT. METHODS: Thoracic [99mTc]NM-01 SPECT/CT was performed in lung cancer patients (n = 10) at baseline and 9-weeks following anti-programmed cell death protein 1 (PD-1) therapy. Baseline and 9-week left ventricular and right ventricular to blood pool ratios (LVmax:BP) and (RVmax:BP) were measured. LVmax was compared to background skeletal muscle (musclemax). Intra-rater reliability was determined by intraclass correlation coefficient (ICC) and Bland-Altman analysis. RESULTS: Mean LVmax:BP values were 2.76 ± 0.67 at baseline vs 2.55 ± 0.77 at 9 weeks (p = 0.42). Mean RVmax:BP was 1.82 ± 0.32 at baseline vs 1.76 ± 0.45 at 9 weeks (p = 0.67). Myocardial PD-L1 expression was at least threefold greater than skeletal muscle at baseline for the LV (LVmax to musclemax 3.71 ± 0.77 vs 0.98 ± 0.20 (p < 0.001)) and at least twofold for the RV (LVmax to musclemax 2.49 ± 0.63 vs 0.98 ± 0.20 (p < 0.001)). There was excellent intra-rater reliability for LVmax:BP with ICC 0.99 (95% confidence interval 0.94-0.99, p < 0.001), mean bias -0.05 ± 0.14 (95% limits of agreement -0.32 to 0.21). There were no major adverse cardiovascular events or myocarditis during follow-up. CONCLUSION: This study is the first to report PD-L1 expression of the heart that can be quantified non-invasively without invasive myocardial biopsy, with high reliability and specificity. This technique can be applied to investigate myocardial PD-L1 expression in ICI-associated myocarditis and cardiomyopathies. Clinical trial registration PD-L1 Expression in Cancer (PECan) study (NCT04436406). https://clinicaltrials.gov/ct2/show/NCT04436406 June 18th, 2020.

15.
Pediatr Res ; 93(1): 160-167, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35411069

RESUMEN

BACKGROUND: Our study aims to explore the experience of having a central venous access device (CVAD) from the perspective of the child and family and how movements within and outside of hospital environments influence this experience. METHODS: A mixed-methods study was conducted across Children's Health Queensland (Australia), including inpatient and home-care settings. Children less than 18 years with CVADs were eligible and followed for 3 months or CVAD removal. A subgroup of primary caregivers participated in semi-structured interviews. Quantitative and qualitative measures of child and family CVAD experiences were explored. RESULTS: In total, 163 patients with 200 CVADs were recruited and followed for 6993 catheter days (3329 [48%] inpatients; 3147 [45%] outpatients; 517 [7%] home). Seventeen participants were interviewed. Experiences of having a CVAD were complex but predominantly positive primarily related to personalized CVAD care, healthcare quality, and general wellbeing. Their experience was shaped by their movements through hospital and home environments, including care variation and distress with procedures. Device selection and insertion location further influenced experience, including safety, impairments in activities of daily living, school, and recreation. CONCLUSIONS: CVAD experiences were influenced by nonmodifiable (e.g., diagnosis) and modifiable factors (e.g., education; care variation). Clinical approaches and policies that account for family and child considerations should be explored. IMPACT: Variation in decision making and management for pediatric CVADs is accepted by many clinicians, but the influence this variation has on the health experience of children and their families is less well explored. This is the first study to draw from a broad range of children requiring CVADs to determine their experience within and outside of healthcare facilities. Interdisciplinary clinicians and researchers need to work collaboratively with children and their families to provide resources and support services to ensure they have positive experiences with CVADs, no matter where they are managed, or who they are managed by.


Asunto(s)
Cateterismo Venoso Central , Catéteres Venosos Centrales , Servicios de Atención de Salud a Domicilio , Humanos , Niño , Actividades Cotidianas , Australia , Escolaridad
16.
Amyloid ; 29(4): 255-262, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35575118

RESUMEN

BACKGROUND: ß2-microglobulin amyloidosis was first described in the 1980s as a protein deposition disease associated with long-term haemodialysis. More recently, two inherited forms resulting from separate point mutations in the ß2-microglobulin gene have been identified. In this report, we detail a novel ß2M variant, P32L, caused by a unique dinucleotide mutation that is linked to systemic hereditary ß2-microglobulin amyloidosis. METHODS: Three family members from a Portuguese kinship featured cardiomyopathy, requiring organ transplantation in one case, along with soft tissue involvement; other involvements included gastrointestinal, neuropathic and sicca syndrome. In vitro studies with recombinant P32L, P32G, D76N and wild-type ß2-microglobulin were undertaken to compare the biophysical properties of the proteins. RESULTS: The P32L variant was caused by the unique heterozygous dinucleotide mutation c.154_155delinsTT. Amyloid disease featured lowered serum ß2-microglobulin levels with near equal amounts of circulating P32L and wild-type proteins; amyloid deposits were composed exclusively of P32L variant protein. In vitro studies of P32L demonstrated thermodynamic and chemical instability and enhanced susceptibility to proteolysis with rapid formation of pre-fibrillar oligomeric structures by N- and C-terminally truncated species under physiological conditions. CONCLUSIONS: This work provides both clinical and experimental evidence supporting the critical role of P32 residue replacement in ß2M amyloid fibrillogenesis.


Asunto(s)
Amiloidosis Familiar , Amiloidosis , Humanos , Amiloide/metabolismo , Amiloidosis/metabolismo , Amiloidosis Familiar/genética , Microglobulina beta-2/metabolismo , Prolina/genética
17.
Pediatr Res ; 92(5): 1381-1390, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35136199

RESUMEN

BACKGROUND: Healthcare delivery is reliant on a functional central venous access device (CVAD), but the knowledge surrounding the burden of pediatric CVAD-associated harm is limited. METHODS: A prospective cohort study at a tertiary-referral pediatric hospital in Australia. Children <18 years undergoing insertion of a CVAD were screened from the operating theatre and intensive care unit records, then assessed bi-weekly for up to 3 months. Outcomes were CVAD failure and complications, and associated healthcare costs (cost of complications). RESULTS: 163 patients with 200 CVADs were recruited and followed for 6993 catheter days, with peripherally inserted central catheters most common (n = 119; 60%). CVAD failure occurred in 20% of devices (n = 30; 95% CI: 15-26), at an incidence rate (IR) of 5.72 per 1000 catheter days (95% CI: 4.09-7.78). CVAD complications were evident in 43% of all CVADs (n = 86; 95% CI: 36-50), at a rate of 12.29 per 1000 catheter days (95% CI: 9.84-15.16). CVAD failure costs were A$826 per episode, and A$165,372 per 1000 CVADs. Comparisons between current and recommended practice revealed inconsistent use of ultrasound guidance for insertion, sub-optimal tip-positioning, and appropriate device selection. CONCLUSIONS: CVAD complications and failures represent substantial burdens to children and healthcare. Future efforts need to focus on the inconsistent use of best practices. IMPACT: Current surveillance of central venous access device (CVAD) performance is likely under-estimating actual burden on pediatric patients and the healthcare system. CVAD failure due to complication was evident in 20% of CVADs. Costs associated with CVAD complications average at $2327 (AUD, 2020) per episode. Further investment in key diverse practice areas, including new CVAD types, CVAD pathology-based occlusion and dislodgment strategies, the appropriate use of device types, and tip-positioning technologies, will likely lead to extensive benefit.


Asunto(s)
Cateterismo Venoso Central , Cateterismo Periférico , Catéteres Venosos Centrales , Niño , Humanos , Catéteres Venosos Centrales/efectos adversos , Estudios Prospectivos , Incidencia , Australia/epidemiología , Cateterismo Venoso Central/efectos adversos
18.
Cancer Nurs ; 45(6): 438-446, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35131974

RESUMEN

BACKGROUND: Central venous access devices (CVADs) are integral to cancer care provision. Despite the high prevalence of CVAD complications in children with cancer, preventative strategies are understudied. OBJECTIVE: The aim of this study was to assess study feasibility, occlusive events, thrombolytic use, adverse events, and direct costs of catheter lock solutions. METHODS: A single-center, parallel-group, pilot randomized controlled trial was undertaken at a tertiary-referral pediatric hospital in Australia. Children 18 years or younger with an oncological or malignant hematological condition and a CVAD were eligible. Participants were 1:1 randomized to (1) normal or (2) heparinized (10-100 U/mL; CVAD-type dependent) saline lock solutions. RESULTS: Of 217 children assessed for eligibility, 61 were recruited and randomized to normal (n = 30; 3850 CVAD days) or heparinized (n = 31; 4036 CVAD days) saline. Eligibility (52%) and recruitment (54%) feasibility targets were not met. Protocol adherence was high (95% assessments), with no attrition. Parent/clinician satisfaction of interventions was high (median, 10/10 clinicians/parents). Complete CVAD occlusion occurred in heparin only (n = 2, 6.7% CVADs; incidence rate [IR], 0.49/1000 CVAD days [0.06-1.78]). Central venous access device partial occlusion was detected in 23.3% of CVADs in heparin (n = 7; IR, 2.73/1000 CVAD days [1.36-4.87]) and 13.8% of CVADs in normal saline (n = 4; IR, 2.59/1000 CVAD days [1.24-4.77]). Thrombolytic agents were used in 16.7% heparin (5 CVADs) and 3.5% normal saline (1 CVAD). Adverse events did not differ between groups. CONCLUSION: Multisite randomized controlled trials examining CVAD locks are safe, but strategies and resources to increase recruitment and eligibility are required. IMPLICATIONS FOR PRACTICE: Both routine CVAD lock solutions seem safe but may not prevent all forms of CVAD-associated harm.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Catéteres Venosos Centrales , Neoplasias , Niño , Humanos , Infecciones Relacionadas con Catéteres/prevención & control , Cateterismo Venoso Central/efectos adversos , Catéteres Venosos Centrales/efectos adversos , Fibrinolíticos , Heparina/uso terapéutico , Neoplasias/tratamiento farmacológico , Proyectos Piloto , Solución Salina
19.
BMC Health Serv Res ; 22(1): 220, 2022 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-35177041

RESUMEN

OBJECTIVE: To develop and validate a difficult intravenous access risk assessment and escalation pathway, to increase first time intravenous insertion success in paediatrics. METHODS: Mixed methods underpinned by literature and co-production principles. Iterative development of the instrument was informed through semi-structured interviews and stakeholder workshops. The instrument includes a risk assessment, inserter skill self-assessment, and escalation pathways. Reproducibility, reliability, and acceptability were evaluated in a prospective cohort study at a quaternary paediatric hospital in Australia. RESULTS: Interview data (three parents, nine clinicians) uncovered two themes: i) Recognition of children with DIVA and subsequent escalation is ad hoc and problematic; and ii) Resources and training impact inserter confidence and ability. Three workshops were delivered at monthly intervals (February-April 2020) involving 21 stakeholders culminating in the co-production of the "DIVA Key". The DIVA Key was evaluated between May-December 2020 in 78 children; 156 clinicians. Seventy-eight paired assessments were undertaken with substantial agreement (concordance range = 81.5 to 83.0%) between the assessors. Interrater reliability of the DIVA risk assessment was moderate (kappa = 0.71, 95% CI 0.63-0.80). The DIVA Key predicted multiple insertion attempts for red (high risk) DIVA classification (relative risk ratio 5.7, 95% CI 1.2-27.1; reference low risk). Consumer and clinician satisfaction with DIVA Key was high (median (IQR) = 10 [8-10]; 8 [8-10 respectively). CONCLUSION: The DIVA Key is a straightforward, reliable instrument with inbuilt escalation pathway to support the identification of children with difficult intravenous access.


Asunto(s)
Cánula , Cateterismo Periférico , Administración Intravenosa , Niño , Humanos , Estudios Prospectivos , Reproducibilidad de los Resultados
20.
Health Expect ; 25(1): 177-190, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34580957

RESUMEN

BACKGROUND: Compromised bone health is often associated with depression and chronic pain. OBJECTIVE: To examine: (1) the experience of existing depression and chronic nonfracture pain in patients with a fragility fracture; and (2) the effects of the fracture on depression and pain. DESIGN: A phenomenological study guided by Giorgi's analytical procedures. SETTING AND PARTICIPANTS: Fracture patients who reported taking prescription medication for one or more comorbidities, excluding compromised bone health. MAIN VARIABLES STUDIED: Patients were interviewed within 6 weeks of their fracture, and 1 year later. Interview questions addressed the recent fracture and patients' experience with bone health and their other health conditions, such as depression and chronic pain, including the medications taken for these conditions. RESULTS: Twenty-six patients (5 men, 21 women) aged 45-84 years old with hip (n = 5) and nonhip (n = 21) fractures were recruited. Twenty-one participants reported depression and/or chronic nonfracture pain, of which seven reported having both depression and chronic pain. Two themes were consistent, based on our analysis: (1) depression and chronic pain overshadowed attention to bone health; and (2) the fracture exacerbated reported experiences of existing depression and chronic pain. CONCLUSION: Experiences with depression and pain take priority over bone health and may worsen as a result of the fracture. Health care providers treating fragility fractures might ask patients about depression and pain and take appropriate steps to address patients' more general emotional and physical state. PATIENT CONTRIBUTION: A patient representative was involved in the study conception, data interpretation and manuscript writing.


Asunto(s)
Dolor Crónico , Fracturas Osteoporóticas , Anciano , Anciano de 80 o más Años , Densidad Ósea , Dolor Crónico/etiología , Depresión/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fracturas Osteoporóticas/complicaciones , Fracturas Osteoporóticas/psicología , Fracturas Osteoporóticas/terapia , Investigación Cualitativa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA