Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Dent Mater ; 2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-38945742

RESUMEN

OBJECTIVES: To assess the effects of different aging protocols on chemical, physical, and mechanical properties of an experimental ATZ composite compared to a zirconia. METHODS: Disc-shaped specimens were obtained through uniaxial pressing of commercial powders (Tosoh), ATZ comprised of 80%ZrO2/20%Al2O3 (TZ-3YS20AB) and 3Y-TZP (3Y-SBE). The specimens of each material were divided into different groups according to the aging protocol: immediate, autoclave aging and hydrothermal reactor aging. The aging protocols were performed at 134 ºC for 20 h at 2.2 bar. Crystalline evaluations were performed using X-Ray Diffraction. The nanoindentation tests measured the elastic modulus (Em) and hardness (H). Biaxial flexural strength was performed, and Weibull statistics were used to determine the characteristic strength and Weibull modulus. The probability of survival was also determined. The Em and H data were analyzed by one-way ANOVA and Tukey test. RESULTS: Diffractograms revealed the presence of monoclinic phase in both materials after aging. The hydrothermal reactor decreased the Em for ATZ compared to its immediate condition; and the H for both ATZ and 3Y-TZP regarding their immediate and autoclave aging conditions, respectively. The aging protocols significantly increased the characteristic strength for ATZ, while decreased for 3Y-TZP. No difference regarding Weibull modulus was observed, except for 3Y-TZP aged in reactor. For missions of up to 500 MPa, both materials presented a high probability of survival (>99 %) irrespective of aging condition. SIGNIFICANCE: The synthesized ATZ composite exhibited greater physical and microstructural stability compared to 3Y-TZP, supporting potential application of the experimental material for long-span reconstructive applications.

2.
J Esthet Restor Dent ; 36(2): 373-380, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37605963

RESUMEN

OBJECTIVE: To investigate the effect of ceramic thickness and dental substrate (enamel vs. dentin/enamel) on the survival rate and failure load of non-retentive occlusal veneers. MATERIALS AND METHODS: Human maxillary molars (n = 60) were divided into five test-groups (n = 12). The groups (named DE-1.5, DE-1.0, DE-0.5, E-1.0, E-0.5) differed in their dental substrate (E = enamel, DE = dentin/enamel) and restoration thickness (standard: 1.5 mm, thin: 1.0 mm, ultrathin: 0.5 mm). All teeth were prepared for non-retentive monolithic lithium-disilicate occlusal veneers (IPS e.max Press, Ivoclar). Restorations were adhesively cemented (Syntac Classic/Variolink II, Ivoclar) and exposed to thermomechanical fatigue (1.2 million cycles, 1.6 Hz, 49 N/ 5-55°C). Single load to failure was performed using a universal testing-machine. A linear-regression model was applied, pairwise comparisons used the Student-Newman-Keuls method (p < 0.05). RESULTS: Three dentin-based occlusal veneers (one DE-1.0, two DE-0.5) revealed cracks after fatigue exposure, which corresponds to an overall-survival rate of 95%. Load to failure resulted in the following ranking: 2142 N(DE-0.5) > 2105 N(E-1.0) > 2075 N(E-0.5) > 1440 N(DE-1.5) > 1430 N(DE-1.0). Thin (E-1.0) and ultrathin enamel-based occlusal veneers (E-0.5) revealed high failure loads and surpassed the standard thickness dentin-based veneers (DE-1.5) significantly (p = 0.044, p = 0.022). CONCLUSION: All tested monolithic lithium disilicate occlusal veneers obtained failure loads above physiological chewing forces. Thin and ultrathin enamel-based occlusal veneers outperformed the standard thick dentin-based occlusal veneers. CLINICAL SIGNIFICANCE: Minimally invasive enamel-based occlusal veneer restorations with non-retentive preparation design may serve as a conservative treatment option.


Asunto(s)
Cerámica , Porcelana Dental , Humanos , Tasa de Supervivencia , Diente Molar , Ensayo de Materiales , Análisis del Estrés Dental , Coronas con Frente Estético , Fracaso de la Restauración Dental
3.
J Esthet Restor Dent ; 36(1): 47-55, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37772362

RESUMEN

OBJECTIVE: To evaluate the effect of different hydrofluoric acid concentrations and etching times on the surface, chemical composition and microstructure of lithium disilicate. MATERIAL AND METHODS: Ninety specimens of pressed lithium disilicate (LDS) were obtained (IPS e.max Press, Rosetta SP and LiSi Press). The specimens of each material were divided in two groups according to the hydrofluoric acid concentration: 5% and 10% (n = 15/group), and subdivided according to the etching time: 20, 40 and 60 s (n = 5/group). Crystalline evaluations and chemical composition were performed through x-ray diffraction (XRD) and energy-dispersive x-ray spectroscopy (EDS), respectively. Microstructural analyses were performed by scanning electron microscope (SEM), surface roughness (Ra), and material thickness removal evaluation. Thickness removal and Ra data were analyzed by ANOVA and Tukey test (p < 0.05). RESULTS: XRD demonstrated characteristic peaks of lithium disilicate crystals, lithium phosphate and of a vitreous phase for all materials. EDS identified different compositions and SEM confirmed different surface responses to acid etching protocols. Material and etching time influenced Ra and material thickness removal (p < 0.05). CONCLUSION: Hydrofluoric acid concentration and etching time affect the surface characteristics of LDS differently. LiSi Press presented higher resistance to hydrofluoric acid etching compared to e.max Press and Rosetta SP. CLINICAL SIGNIFICANCE: Applying the appropriate etching protocol is pivotal to avoid excessive material removal and to prevent jeopardize the mechanical and optical properties of the material.


Asunto(s)
Recubrimiento Dental Adhesivo , Ácido Fluorhídrico , Ácido Fluorhídrico/química , Ensayo de Materiales , Porcelana Dental/química , Cerámica/química , Propiedades de Superficie , Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química
4.
J Prosthet Dent ; 130(5): 739.e1-739.e8, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37684141

RESUMEN

STATEMENT OF PROBLEM: The bonding of implant-supported prostheses is determined by abutment material, convergence angle, height, surface treatment, and luting agents. However, studies evaluating the bonding of luting agents to titanium base abutments with different heights under fatigue conditions are scarce. PURPOSE: The purpose of this in vitro study was to evaluate the retention of zirconia crowns bonded with different luting agents to titanium base abutments of different heights before and after fatigue testing. MATERIAL AND METHODS: Zirconia crowns were designed, milled, and distributed into 4 experimental groups according to the luting agents (G-Multi Primer/G-Cem LinkForce [MP/GC] and Scotchbond Universal/RelyX Ultimate [SU/RU]) and titanium base abutment heights (2.5 mm and 4 mm) (n=10). Pull-out testing was performed in a universal testing machine at a crosshead speed of 1 mm/min until crown displacement. Fatigue testing was performed by an electric precision fatigue simulator (1×106 cycles; 100 N; and 15 Hz), followed by pull-out testing of fatigued specimens. Collected data were statistically evaluated by using a linear mixed model after post hoc comparisons by the least significant difference test (α=.05). RESULTS: Luting agents, abutment heights, and fatigue influenced the bonding retention of zirconia crowns to titanium base abutments. SU/RU agents promoted higher pull-out compared with MP/GC for both abutment heights before and after fatigue. Higher abutment height increased pull-out regarding lower abutment height for SU/RU materials before and after fatigue testing. Although fatigue had no significant effect on the pull-out of MP/GC, lower bond retention was observed for SU/RU after fatigue, regardless of abutment height. CONCLUSIONS: Luting agent composition and the interaction with abutment height and fatigue influenced the retention of zirconia crowns to titanium base abutments.


Asunto(s)
Cementos Dentales , Implantes Dentales , Cementos Dentales/química , Titanio/química , Coronas , Circonio/química , Ensayo de Materiales , Pilares Dentales , Análisis del Estrés Dental
5.
Dent J (Basel) ; 11(9)2023 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-37754327

RESUMEN

To assess the reliability and failure modes of Ti-base abutments supported by narrow and wide-diameter implant systems. Narrow (Ø3.5 × 10 mm) and wide (Ø5 × 10 mm) implant systems of two different manufacturers with internal conical connections (16°) and their respective Ti-base abutments (3.5 and 4.5 mm) were evaluated. Ti-base abutments were torqued to the implants, standardized metallic maxillary incisor crowns were cemented, and step stress accelerated life testing of eighteen assemblies per group was performed in three loading profiles: mild, moderate, and aggressive until fracture or suspension. Reliability for missions of 100,000 cycles at 100 and 150 N was calculated, and fractographic analysis was performed. For missions at 100 N for 100,000 cycles, both narrow and wide implant systems exhibited a high probability of survival (≥99%, CI: 94-100%) without significant differences. At 150 N, wide-diameter implants presented higher reliability (≥99%, CI: 99-100%) compared to narrow implants (86%, CI: 61-95%), with no significant differences among manufacturers. Failure mode predominantly involved Ti-base abutment fractures at the abutment platform. Ti-base abutments supported by narrow and wide implant systems presented high reliability for physiologic masticatory forces, whereas for high load-bearing applications, wide-diameter implants presented increased reliability. Failures were confined to abutment fractures.

6.
Materials (Basel) ; 15(23)2022 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-36499960

RESUMEN

No evidence-based prosthetic treatment concept for 3-unit fixed-dental-prostheses (FDPs) on ceramic implants is currently available. Therefore, the aim of this in vitro study was to investigate the failure load and fatigue behavior of monolithic and bi-layer zirconia FDPs supported by one-piece ceramic implants. Eighty 3-unit FDPs supported by 160 zirconia-implants (ceramic.implant; vitaclinical) were divided into 4 groups (n = 20 each): Group Z-HT: 3Y-TZP monolithic-zirconia (Vita-YZ-HT); Group Z-ST: 4Y-TZP monolithic-zirconia (Vita-YZ-ST); Group FL: 3Y-TZP zirconia (Vita-YZ-HT) with facial-veneer (Vita-VM9); Group RL (Rapid-layer): PICN "table-top" (Vita-Enamic), 3Y-TZP-framework (Vita-YZ-HT). Half of the test samples (n = 10/group) were fatigued in a mouth-motion chewing-simulator (F = 98 N, 1.2 million-cycles) with simultaneous thermocycling (5−55 °C). All specimens (fatigued and non-fatigued) were afterwards exposed to single-load-to-failure-testing (Z010, Zwick). Statistical analysis was performed using ANOVA, Tukey's post-hoc tests and two-sample t-tests (p < 0.05, Bonferroni-corrected where appropriate). All specimens withstood fatigue application. While the effect of fatigue was not significant in any group (p = 0.714), the choice of material had a significant effect (p < 0.001). Material FL recorded the highest failure loads, followed by Z-ST, Z-HT and RL, both with and without fatigue application. Taken together, all tested FDP material combinations survived chewing forces that exceeded physiological levels. Bi-Layer FL and monolithic Z-ST showed the highest resilience and might serve as reliable prosthetic reconstruction concepts for 3-unit FDPs on ceramic implants.

7.
J Mech Behav Biomed Mater ; 135: 105451, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36162164

RESUMEN

To evaluate the effect of fatigue and aging on the crystalline content and reliability of a zirconia-toughened-alumina (ZTA) composite compared to its individual counterpart materials (3Y-TZP and Al2O3). Thirty-six disc-shaped specimens per group were obtained to comply with ISO 6872:2015. Crystalline content, microstructure and reliability of experimental groups were evaluated in four stages: 1) immediate; 2) aged; 3) fatigued; 4) aged + fatigue. Aging was performed in autoclave and Step-Stress-Accelerated-Life-Testing (SSALT) was performed using three stress profiles. Weibull statistics were used to determine Weibull parameters and life-expectancy. A significant increase in monoclinic phase in 3Y-TZP was observed after aging (19.31%), fatigue (17.88%) and aging + fatigue (55.81%), while ZTA evidenced minimal variation among all conditions (<5.69%). 3Y-TZP presented higher reliability than ZTA at 300 and 500 MPa, and ZTA outperformed Al2O3 at the same stress missions. None of the ceramics yielded acceptable reliability at 800 MPa. A higher characteristic strength was observed for 3Y-TZP, followed by ZTA and Al2O3. While after aging ZTA and Al2O3 remained stable, 3Y-TZP exhibited a significant increase in the characteristic stress. Aging did not affect the reliability of ZTA and Al2O3. 3Y-TZP demonstrated an increase in monoclinic content and characteristic strength after aging.


Asunto(s)
Óxido de Aluminio , Itrio , Anciano , Óxido de Aluminio/química , Cerámica/química , Materiales Dentales , Humanos , Ensayo de Materiales , Reproducibilidad de los Resultados , Propiedades de Superficie , Itrio/química , Circonio/química
8.
J Esthet Restor Dent ; 34(1): 145-153, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34989466

RESUMEN

OBJECTIVE: To evaluate the effect of ceramic thicknesses, bonding surface (enamel vs. dentin), and preparation design (box vs. no box) on the fatigue survival and failure load of minimally invasive full-veneer restorations. MATERIALS AND METHODS: Human-premolars (n = 60) were divided into five test groups (n = 12). All teeth received full-veneer preparation with the following occlusal/labial thicknesses: standard: 1.5/0.8 mm; thin: 1.0/0.6 mm; ultrathin 0.5/0.4 mm. Preparations for each ceramic thickness were refined in enamel (E-1.0 and E-0.5) or dentin (D-1.5, D-1.0, and D-0.5). Control groups DB-1.5, EB-1.0, and EB-0.5 received box preparations. Monolithic lithium disilicate restorations (IPS-e.max-Press, Ivoclar Vivadent) were adhesively cemented (Syntac-Classic/Variolink-II, Ivoclar Vivadent) and subjected to cyclic mechanical loading (F = 49 N, 1.2 million cycles) with simultaneous thermocycling (5-55°C). All specimens were exposed to single load-to-failure. Pair-wise differences were calculated by using a linear regression model and Student-Newman-Keuls method (p < 0.05). RESULTS: All full-veneers of group D-1.5, E-1.0, E-0.5, DB-1.5, EB-1.0, and EB-0.5 survived fatigue. Two full-veneers (D-1.0 and D-0.5) revealed cracks during fatigue, resulting in an overall fatigue survival rate of 98.1%. Mean load-to-failure values (N) were as followed: 1005 (D-1.5); 866 (D-1.0); 816 (D-0.5); 1495 (E-1.0); 1279 (E-0.5); 1129 (DB-1.5); 1087 (EB-1.0); and 833 (EB-0.5). Irrespective of ceramic thicknesses, enamel-based full-veneers resulted in higher failure loads than dentin-based restorations. Box preparation reduced the failure loads of thin and ultrathin enamel-based restorations. CONCLUSION: All tested monolithic lithium disilicate full-veneer restorations exceeded physiological masticatory forces. Minimally invasive full-veneer restorations with enamel as a bonding surface and a non-retentive preparation design showed superior performance. CLINICAL SIGNIFICANCE: Enamel-based non-retentive full-veneers made of monolithic lithium disilicate may serve as a reliable and esthetical minimally invasive treatment option for premolars.


Asunto(s)
Porcelana Dental , Coronas con Frente Estético , Cerámica , Esmalte Dental , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Humanos , Ensayo de Materiales
9.
Materials (Basel) ; 14(24)2021 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-34947134

RESUMEN

To evaluate the failure-load and survival-rate of screw-retained monolithic and bi-layered crowns bonded to titanium-bases before and after mouth-motion fatigue, 72 titanium-implants (SICvantage-max, SIC-invent-AG) were restored with three groups (n = 24) of screw-retained CAD/CAM implant-supported-single-crowns (ISSC) bonded to titanium-bases: porcelain-fused-to-metal (PFM-control), porcelain-fused-to-zirconia (PFZ-test) and monolithic LDS (LDS-test). Half of the specimens (n = 12/group) were subjected to fatigue in a chewing-simulator (1.2 million cycles, 198 N, 1.67 Hz, thermocycling 5-55 °C). All samples were exposed to single-load-to-failure without (PFM0, PFZ0, LDS0) or with fatigue (PFM1, PFZ1, LDS1). Comparisons were statistically analyzed with t-tests and regression-models and corrected for multiple-testing using the Student-Neuman-Keuls method. All PFM and LDS crowns survived fatigue exposure, whereas 16.7% of PFZ showed chipping failures. The mean failure-loads (±SD) were: PFM0: 2633 ± 389 N, PFM1: 2349 ± 578 N, PFZ0: 2152 ± 572 N, PFZ1: 1686 ± 691 N, LDS0: 2981 ± 798 N, LDS1: 2722 ± 497 N. Fatigue did not influence load to failure of any group. PFZ ISSC showed significantly lower failure-loads than monolithic-LDS regardless of artificial aging (p < 0.05). PFM ISSC showed significantly higher failure loads after fatigue than PFZ (p = 0.032). All ISSC failed in a range above physiological chewing forces. Premature chipping fractures might occur in PFZ ISSC. Monolithic-LDS ISSC showed high reliability as an all-ceramic material for screw-retained posterior hybrid-abutment-crowns.

10.
Materials (Basel) ; 14(8)2021 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-33921126

RESUMEN

This laboratory study aimed to evaluate the thermo-mechanical fatigue behavior and failure modes of monolithic and rapid-layer posterior single-crowns (SCs) supported by zirconia implants. METHODS: 120 all-ceramic crowns supported by one-piece zirconia implants (ceramic.implant; vitaclinical) were divided into five groups (n = 24 each): Group Z-HT: 3Y-TZP monolithic-zirconia (Vita-YZ-HT); Group Z-ST: 4Y-TZP monolithic-zirconia (Vita-YZ-ST); Z-XT: 5Y-TZP monolithic-zirconia (Vita-YZ-XT); Group E: monolithic-polymer-infiltrated ceramic network (PICN,Vita-Enamic); Group RL (rapid layer): PICN-"table-top" (Vita-Enamic), 3Y-TZP-framework (Vita-YZ-HT). Half of the specimens of each group (n = 12) were exposed to fatigue with cyclic mechanical loading (F = 198N, 1.2-million cycles) and simultaneous thermocycling (5-55 °C). Single-load-to-failure testing (Z010, Zwick) was performed for all specimens without/with fatigue application. Data analysis was performed using ANOVA, Tukey's post-hoc test, two-sample t-test and Bonferroni correction (p < 0.05). RESULTS: All specimens survived fatigue exposure. Significant differences in failure loads were detected among groups (p ≤ 0.004). Materials Z-HT and Z-ST showed the highest failure loads followed by Z-XT, RL and E. The influence of fatigue was only significant for material RL. CONCLUSIONS: All types of tested materials exceeded clinically acceptable failure load values higher than 900N and can be recommended for clinical use. Z-HT and Z-ST appear to be highly reliable towards fatigue. Rapid-layer design of PICN and YZ-HT might be an interesting treatment concept for posterior implant SCs.

11.
Int J Prosthodont ; 33(3): 272-276, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32320179

RESUMEN

PURPOSE: To analyze the clinical behavior of screw-retained monolithic lithium disilicate (LDS) implant-supported single crowns (ISSCs) over a 1-year follow-up. MATERIALS AND METHODS: A total of 28 patients were restored with 45 screw-retained monolithic LDS (press-fabricated) ISSCs bonded to titanium bases in posterior sites. Modified United States Public Health Service criteria and Kaplan-Meier survival and success rates were evaluated. RESULTS: A total of 27 patients with 44 ISSCs were evaluated 12 months (mean ± standard deviation: 13.02 ± 2.28) after prosthesis delivery. No implant or crown failures occurred. The Kaplan-Meier survival and success rates were each 100% after 1 year. Minorly increased surface roughness was noted in the occlusal contact point areas of 9 ISSCs (20.5% Bravo rating). Marginal adaptation, color match, and anatomical form stayed favorable over time. CONCLUSION: Press-fabricated LDS monolithic screw-retained implant crowns appear to be a promising treatment option for posterior implants under short-term observation.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Tornillos Óseos , Porcelana Dental , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Fracaso de la Restauración Dental , Humanos , Datos Preliminares , Estudios Prospectivos
12.
Int J Prosthodont ; 33(2): 160-168, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32069340

RESUMEN

PURPOSE: To evaluate the clinical outcomes of monolithic CAD/CAM-fabricated polymer-infiltrated ceramic network (PICN) single crowns (SC) after 3 years. MATERIALS AND METHODS: A total of 34 patients who received 76 single crowns were included in this cohort study. Full-coverage crown preparation with reduced thickness (1.0 to 1.5 mm) was applied. All monolithic PICN SCs (VITA Enamic) were manufactured using a CAD/CAM system and adhesively seated. Clinical follow-up evaluations were performed at 6, 12, 24, and 36 months after insertion using modified United States Public Health Service (USPHS) criteria. Kaplan-Meier survival and success methods were applied to calculate absolute and relative failures. To determine effects of time and restoration, a mixed logit model was adjusted for the modified USPHS criteria (P < .05). RESULTS: PICN SCs revealed an estimated Kaplan-Meier survival rate of 93.9% after 3 years. Four clinically unacceptable fractures occurred, which resulted in replacement of the affected SCs. Neither secondary caries nor debonding were recorded. The 3-year Kaplan-Meier success rate was 92.7%. Significant increases in marginal discoloration (P = .0002) and surface roughness (P < .0001) were noted over time. Color match, anatomical form, and marginal adaptation remained favorable over the given observation period. CONCLUSION: PICN CAD/CAM crowns with reduced thickness showed acceptable survival and success rates over a service time of 36 months. However, extended clinical follow-up periods are needed to evaluate the long-term performance.


Asunto(s)
Porcelana Dental , Diseño de Prótesis Dental , Cerámica , Estudios de Cohortes , Diseño Asistido por Computadora , Coronas , Fracaso de la Restauración Dental , Humanos , Polímeros , Estudios Prospectivos
13.
Int J Oral Maxillofac Implants ; 34(5): 1091­1097, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30934031

RESUMEN

PURPOSE: To evaluate the bending moments and failure modes of zirconia meso-abutments bonded to titanium bases restored with different monolithic all-ceramic crowns after aging, and to compare them to titanium abutments restored with all-ceramic crowns. MATERIALS AND METHODS: Forty-eight internal conical connection implants (Conelog, Camlog 4.3 mm diameter) were restored with four different computer-aided design/computed-aided manufacturing (CAD/CAM) abutment-crown combinations (n = 12). Thirty-six customized zirconia meso-abutments were bonded to titanium bases (Conelog Titanium Base CAD/CAM crown, Camlog) and divided into three groups according to the different crown materials: (T1) monolithic lithium-disilicate (e-max CAD, Ivoclar), (T2) monolithic PICN (polymer-infiltrated ceramic network [Enamic, Vita]), and (T3) monolithic zirconia (Lava Plus, 3M ESPE). Twelve titanium customized abutments restored with monolithic lithium-disilicate (e-max CAD, Ivoclar) crowns served as the control group (C). The crowns were equal maxillary central incisors and were adhesively bonded with a resin-based cement (Panavia 21, Kuraray). All samples were embedded in acrylic holders. After aging (1,200,000 cycles, 49 N, 1.67 Hz, 5°C to 50°C, 120 seconds), static load was applied until failure. Bending moments were calculated for comparison of the groups. Data were statistically treated with one-way analysis of variance (ANOVA) followed by Tukey post hoc test (P < .05). Failure modes were analyzed descriptively. RESULTS: The means of the bending moments were 356.4 ± 20.8 Ncm (T1), 357.7 ± 26.3 Ncm (T2), 385.5 ± 21.2 Ncm (T3), and 358.8 ± 25.3 Ncm (C). Group T3 revealed significantly higher mean bending moments than the other groups (P < .05). No differences were found between zirconia meso-abutments supported by titanium bases and customized titanium abutments when lithium-disilicate crowns were used (P > .05). No failures were identified during and after aging. After static load, failures occurred due to fracture of the abutment in the internal connection in all the groups. CONCLUSION: Zirconia meso-abutments bonded to titanium bases showed similar mechanical stability compared with customized titanium abutments. Regarding the crown material, all three tested ceramics (lithium-disilicate, PICN, and zirconia) revealed very good stability when used in the monolithic state.


Asunto(s)
Diseño de Implante Dental-Pilar , Cerámica , Diseño Asistido por Computadora , Coronas , Pilares Dentales , Análisis del Estrés Dental , Ensayo de Materiales , Titanio , Circonio
14.
Clin Oral Implants Res ; 29 Suppl 16: 351-358, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30328181

RESUMEN

OBJECTIVES: The aim of Working Group 4 was to address topics related to biologic risks and complications associated with implant dentistry. Focused questions on (a) diagnosis of peri-implantitis, (b) complications associated with implants in augmented sites, (c) outcomes following treatment of peri-implantitis, and (d) implant therapy in geriatric patients and/or patients with systemic diseases were addressed. MATERIALS AND METHODS: Four systematic reviews formed the basis for discussion in Group 4. Participants developed statements and recommendations determined by group consensus based on the findings of the systematic reviews. These were then presented and accepted following further discussion and modifications as required by the plenary. RESULTS: Bleeding on probing (BOP) alone is insufficient for the diagnosis of peri-implantitis. The positive predictive value of BOP alone for the diagnosis of peri-implantitis varies and is dependent on the prevalence of peri-implantitis within the population. For patients with implants in augmented sites, the prevalence of peri-implantitis and implant loss is low over the medium to long term. Peri-implantitis treatment protocols which include individualized supportive care result in high survival of implants after 5 years with about three-quarters of implants still present. Advanced age alone is not a contraindication for implant therapy. Implant placement in patients with cancer receiving high-dose antiresorptive therapy is contraindicated due to the associated high risk for complications. CONCLUSIONS: Diagnosis of peri-implantitis requires the presence of BOP as well as progressive bone loss. Prevalence of peri-implantitis for implants in augmented sites is low. Peri-implantitis treatment should be followed by individualized supportive care. Implant therapy for geriatric patients is not contraindicated; however, comorbidities and autonomy should be considered.


Asunto(s)
Implantes Dentales/efectos adversos , Fracaso de la Restauración Dental , Odontología , Periimplantitis/etiología , Cuidados Posteriores , Aumento de la Cresta Alveolar , Conservadores de la Densidad Ósea/efectos adversos , Consenso , Bases de Datos Factuales , Implantación Dental Endoósea , Susceptibilidad a Enfermedades , Humanos , Neoplasias/complicaciones , Periimplantitis/diagnóstico , Periimplantitis/epidemiología , Índice Periodontal , Prevalencia , Recurrencia , Factores de Riesgo
15.
Ceram Int ; 43(14): 10999-11005, 2017 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-29097830

RESUMEN

The fabrication of zirconia dental restorations is a time-consuming process due to traditional slow sintering schemes; zirconia (Y-TZP) produced by these conventional routes are predominantly opaque. Novel speed sintering protocols have been developed to meet the demand for time and cost effective chairside CAD/CAM-produced restorations, as well as to control ceramic microstructures for better translucency. Although the speed sintering protocols have already been used to densify dental Y-TZP, the wear properties of these restorations remain elusive. Fast heating and cooling rates, as well as shorter sintering dwell times are known to affect the microstructure and properties of zirconia. Thus, we hypothesize that speed sintered zirconia dental restorations possess distinct wear and physical characteristics relative to their conventionally sintered counterparts. Glazed monolithic molar crowns of translucent Y-TZP (inCoris TZI, Sirona) were fabricated using three distinct sintering profiles: Super-speed (SS, 1580 °C, dwell time 10 min), Speed (S, 1510 °C, dwell time 25 min), and Long-term (LT, 1510 °C, dwell time 120 min). Microstructural, optical and wear properties were investigated. Crowns that were super-speed sintered possessed higher translucency. Areas of mild and severe wear were observed on the zirconia surface in all groups. Micropits in the wear crater were less frequent for the LT group. Groups S and SS exhibited more surface pits, which caused a scratched steatite surface that is associated with a greater volume loss. Tetragonal to monoclinic phase transformation, resulting from the sliding wear process, was present in all three groups. Although all test groups had withstood thermo-mechanical challenges, the presence of hairline cracks emanating from the occlusal wear facets and extending deep into the restoration indicates their susceptibility to fatigue sliding contact fracture.

16.
Eur J Oral Implantol ; 10 Suppl 1: 89-99, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28944371

RESUMEN

AIM: The purpose of this systematic review was to assess the clinical performance of implant-supported monolithic all-ceramic single- and multi-unit restorations. MATERIALS AND METHODS: The electronic databases of MEDLINE via PubMed, the Cochrane Library (CENTRAL) and EMBASE were searched for clinical studies on monolithic all-ceramic single and multi-unit implant-supported fixed dental prostheses. Human studies with a mean follow-up of at least 2 years and published in English or German language peer-reviewed journals up until August 2016 were included. Two independent examiners conducted the literature search and review process. RESULTS: The search resulted in 2510 titles and of these, 57 studies were selected for full-text evaluation. Three studies were included on the basis of the pre-determined criteria. Two articles reported on monolithic lithium disilicate implant-supported single crowns (SC) and revealed a survival rate of 97,8 and 100% after 3 years. One study investigated implant- supported monolithic zirconia SCs and fixed partial dentures (FPD) and showed a survival rate of 100% after 5 years. No studies could be identified on the clinical performance of monolithic resin matrix ceramic restorations. Clinical studies are lacking on the long-term outcome of implant-supported monolithic all-ceramic single- and multi-unit restorations. CONCLUSIONS: Preliminary clinical data indicate high short-term survival for implant-supported monolithic lithium disilicate and zirconia single- and multi-unit restorations. Randomised clinical studies and observations with a longer duration are necessary to validate the broad application of this therapy. Conflict-of-interest statement: The authors declare no conflict of interest.


Asunto(s)
Cerámica , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Humanos
17.
Compend Contin Educ Dent ; 37(5): 340-5, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27419357

RESUMEN

Dental erosion is a global oral health problem that can lead to significant functional and esthetic impairments of the affected patients. Treatment of severe cases with augmented loss of the vertical dimension of occlusion (VDO) represents a challenge for both the dental team and the patient. CAD/CAM technology was used in the presented case to analyze the interocclusal space. Based on a virtual wax-up of the final restorations, CAD/CAM-fabricated preparation splints served as a guide and ensured a most minimally invasive preparation design. Milled polymer provisionals enabled the patient to visualize the final treatment outcome and served as a fracture-resistant temporary restoration to test the increased VDO. Monolithic lithium-disilicate ceramic, defect-oriented restorations with reduced ceramic thickness enabled a functional and reliable reconstruction of the severely compromised dentition. This case report documents a practical, digital approach and discusses the advantages related to treatment time, ease of treatment, and predictability.


Asunto(s)
Bebidas Gaseosas/efectos adversos , Diseño Asistido por Computadora , Rehabilitación Bucal/métodos , Erosión de los Dientes/inducido químicamente , Adulto , Humanos , Masculino
18.
Eur Eat Disord Rev ; 24(4): 341-6, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27045791

RESUMEN

BACKGROUND: There is hardly any empirical evidence on emotion processing by controlled studies in obesity. MATERIAL AND METHODS: Participants rated their emotions in response to visual emotional stimuli from the International Affective Picture System. Study 1 compared obese women with normal-weight controls and women with eating disorders. Study 2 compared obese men with normal-weight controls. RESULTS: Obese women had reduced emotional intensity scores for all basic emotions and the mixed emotion sadness-fear. Obese men had reduced scores for all emotions except happiness and disgust; anger showed a trend towards significance. The results were mainly based on ratings from non-depressed obese individuals. DISCUSSION: Obese men and women scored significantly lower on most basic and mixed emotions. Non-depressed obese subjects seem particularly affected. These new findings must be validated by further study, and longitudinal evaluation after weight loss, e.g. by bariatric surgery, will be of interest. Copyright © 2016 John Wiley & Sons, Ltd and Eating Disorders Association.


Asunto(s)
Síntomas Afectivos/psicología , Emociones/fisiología , Trastornos de Alimentación y de la Ingestión de Alimentos/psicología , Obesidad/psicología , Adulto , Afecto , Síntomas Afectivos/complicaciones , Ira , Cirugía Bariátrica , Estudios de Casos y Controles , Miedo , Femenino , Felicidad , Humanos , Masculino , Percepción , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...