Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Eur Radiol ; 34(3): 1680-1691, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37658894

RESUMEN

OBJECTIVE: The potential of magnetization transfer imaging (MTI) and diffusion tensor imaging (DTI) for the detection and evolution of new multiple sclerosis (MS) lesions was analyzed. METHODS: Nineteen patients with MS obtained conventional MRI, MTI, and DTI examinations bimonthly for 12 months and again after 24 months at 1.5 T MRI. MTI was acquired with balanced steady-state free precession (bSSFP) in 10 min (1.3 mm3 isotropic resolution) yielding both magnetization transfer ratio (MTR) and quantitative magnetization transfer (qMT) parameters (pool size ratio (F), exchange rate (kf), and relaxation times (T1/T2)). DTI provided fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD). RESULTS: At the time of their appearance on MRI, the 21 newly detected MS lesions showed significantly reduced MTR/F/kf and prolonged T1/T2 parameters, as well as significantly reduced FA and increased AD/MD/RD. Significant differences were already observed for MTR 4 months and for qMT parameters 2 months prior to lesions' detection on MRI. DTI did not show any significant pre-lesional differences. Slightly reversed trends were observed for most lesions up to 8 months after their detection for qMT and less pronounced for MTR and three diffusion parameters, while appearing unchanged on MRI. CONCLUSIONS: MTI provides more information than DTI in MS lesions and detects tissue changes 2 to 4 months prior to their appearance on MRI. After lesions' detection, qMT parameter changes promise to be more sensitive than MTR for the lesions' evolutional assessment. Overall, bSSFP-based MTI adumbrates to be more sensitive than MRI and DTI for the early detection and follow-up assessment of MS lesions. CLINICAL RELEVANCE STATEMENT: When additionally acquired in routine MRI, fast bSSFP-based MTI can complement the MRI/DTI longitudinal lesion assessment by detecting MS lesions 2-4 months earlier than with MRI, which could implicate earlier clinical decisions and better follow-up/treatment assessment in MS patients. KEY POINTS: • Magnetization transfer imaging provides more information than DTI in multiple sclerosis lesions and can detect tissue changes 2 to 4 months prior to their appearance on MRI. • After lesions' detection, quantitative magnetization transfer changes are more pronounced than magnetization transfer ratio changes and therefore promise to be more sensitive for the lesions' evolutional assessment. • Balanced steady-state free precession-based magnetization transfer imaging is more sensitive than MRI and DTI for the early detection and follow-up assessment of multiple sclerosis lesions.


Asunto(s)
Imagen de Difusión Tensora , Esclerosis Múltiple , Humanos , Imagen de Difusión Tensora/métodos , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Imagen por Resonancia Magnética/métodos , Anisotropía
2.
JAMA Netw Open ; 2(10): e1914171, 2019 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-31664444

RESUMEN

Importance: Nitric oxide precursors, such as the amino acid l-arginine and the biguanide antidiabetic drug metformin, have been associated with metabolism and muscle function in patients with Duchenne muscular dystrophy (DMD). The treatment of DMD remains an unmet medical need. Objective: To evaluate the benefits and harms of a combination of l-citrulline and metformin treatment among patients with DMD. Design, Setting, and Participants: A single-center randomized double-blind placebo-controlled parallel-group clinical trial was conducted between December 12, 2013, and March 30, 2016, at the University Children's Hospital Basel in Switzerland. A total of 47 ambulant male patients aged 6.5 to 10 years with genetically confirmed DMD were recruited locally and from the patient registries of Switzerland, Germany, Austria, and France. Data were analyzed from April 6, 2016, to September 5, 2019. Interventions: Patients in the treatment group received 2500 mg of l-citrulline and 250 mg of metformin (combination therapy) 3 times a day for 26 weeks compared with patients in the control group, who received placebo. Main Outcomes and Measures: The primary end point was the change in transfer and standing posture, as assessed by the first dimension of the Motor Function Measure, version 32, from baseline to week 26. Secondary end points included assessments of timed function, quantitative muscle force, biomarkers for muscle necrosis, and adverse events. The 2 prespecified subgroups comprised patients who were able to walk 350 m or more in 6 minutes (stable subgroup) and patients who were not able to walk 350 m in 6 minutes (unstable subgroup) at baseline. Results: Among 49 ambulant male children with DMD who were screened for eligibility, 47 patients with a mean (SD) age of 8.2 (1.1) years were randomized to a treatment group receiving combination therapy (n = 23) or a control group receiving placebo (n = 24), and 45 patients completed the study. No significant differences between groups were found in the results of timed function and muscle force tests for overall, proximal and axial, and distal motor function. Among patients receiving combination therapy, the Motor Function Measure first dimension subscore decrease was 5.5% greater than that of patients receiving placebo (95% CI, -1.0% to 12.1%; P = .09). The administration of combination therapy had significantly favorable effects on the first dimension subscore decrease among the 29 patients in the stable subgroup (6.7%; 95% CI, 0.9%-12.6%; P = .03) but not among the 15 patients in the unstable subgroup (3.9%; 95% CI, -13.2% to 20.9%; P = .63). Overall, the treatment was well tolerated with only mild adverse effects. Conclusions and Relevance: Treatment with combination therapy was not associated with an overall reduction in motor function decline among ambulant patients with DMD; however, a reduction in motor function decline was observed among the stable subgroup of patients treated with combination therapy. The statistically nonsignificant difference of distal motor function in favor of combination therapy and the reduced degeneration of muscle tissue appear to support the treatment concept, but the study may have lacked sufficient statistical power. Further research exploring this treatment option with a greater number of patients is warranted. Trial Registration: ClinicalTrials.gov identifier: NCT01995032.


Asunto(s)
Citrulina/uso terapéutico , Hipoglucemiantes/uso terapéutico , Metformina/uso terapéutico , Distrofia Muscular de Duchenne/tratamiento farmacológico , Distrofia Muscular de Duchenne/fisiopatología , Niño , Método Doble Ciego , Quimioterapia Combinada , Europa (Continente) , Humanos , Masculino
3.
Neuromuscul Disord ; 28(1): 16-23, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29174526

RESUMEN

The development of new therapeutic agents for the treatment of Duchenne muscular dystrophy has put a focus on defining outcome measures most sensitive to capture treatment effects. This cross-sectional analysis investigates the relation between validated clinical assessments such as the 6-minute walk test, motor function measure and quantitative muscle MRI of thigh muscles in ambulant Duchenne muscular dystrophy patients, aged 6.5 to 10.8 years (mean 8.2, SD 1.1). Quantitative muscle MRI included the mean fat fraction using a 2-point Dixon technique, and transverse relaxation time (T2) measurements. All clinical assessments were highly significantly inter-correlated with p < 0.001. The strongest correlation with the motor function measure and its D1-subscore was shown by the 6-minute walk test. Clinical assessments showed no correlation with age. Importantly, quantitative muscle MRI values significantly correlated with all clinical assessments with the extensors showing the strongest correlation. In contrast to the clinical assessments, quantitative muscle MRI values were highly significantly correlated with age. In conclusion, the motor function measure and timed function tests measure disease severity in a highly comparable fashion and all tests correlated with quantitative muscle MRI values quantifying fatty muscle degeneration.


Asunto(s)
Imagen por Resonancia Magnética , Músculo Esquelético/diagnóstico por imagen , Distrofia Muscular de Duchenne/diagnóstico , Tejido Adiposo , Niño , Estudios Transversales , Prueba de Esfuerzo , Humanos , Masculino , Actividad Motora , Distrofia Muscular de Duchenne/fisiopatología , Distrofia Muscular de Duchenne/terapia , Muslo
4.
Neuromuscul Disord ; 26(7): 414-22, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27209345

RESUMEN

Becker muscular dystrophy (BMD) has an incidence of 1 in 16 000 male births. This cross-sectional study investigated the relation between validated functional scores and quantitative MRI (qMRI) of thigh muscles in 20 ambulatory BMD patients, aged 18.3-60 years (mean 31.2; SD 11.1). Clinical assessments included the motor function measure (MFM) and its subscales, as well as timed function tests such as the 6-minute walk test (6MWT) and the timed 10-m run/walk test. Quantitative MRI of the thigh muscles included the mean fat fraction (MFF) using a 2-point Dixon (2-PD) technique, and transverse relaxation time (T2) measurements. The mean MFM value was 80.4%, SD 9.44 and the D1 subscore 54.5%, SD 19.9. The median 6MWT was 195m, IQR 160-330.2. The median 10-m run/walk test was 7.4 seconds, IQR 6.1-9.3. The mean fat fraction of the thigh muscles was 55.6%, SD 17.4%, mean T2 relaxation times of all muscles: 69.9 ms, SD 14.4. The flexors had the highest MFF and T2 relaxation times, followed by the extensors and the adductors. MFF and global T2 relaxation times were highly negatively correlated with the MFM total, D1-subscore and 6MWT, and positively correlated with the 10 m run/walk test time (p < 0.01). Age was not correlated with MFF, global T2 relaxation time or clinical assessments. Both MFF and T2 measures in the thigh muscle were well correlated with clinical function in BMD and may serve as a surrogate outcome measure in clinical trials.


Asunto(s)
Músculo Esquelético/diagnóstico por imagen , Distrofia Muscular de Duchenne/diagnóstico por imagen , Distrofia Muscular de Duchenne/fisiopatología , Muslo/diagnóstico por imagen , Caminata/fisiología , Tejido Adiposo/diagnóstico por imagen , Adolescente , Adulto , Factores de Edad , Estudios Transversales , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Músculo Esquelético/fisiopatología , Distrofia Muscular de Duchenne/genética , Índice de Severidad de la Enfermedad , Muslo/fisiopatología , Prueba de Paso , Adulto Joven
5.
PLoS One ; 11(1): e0147634, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26799743

RESUMEN

UNLABELLED: Altered neuronal nitric oxide synthase function in Duchenne muscular dystrophy leads to impaired mitochondrial function which is thought to be one cause of muscle damage in this disease. The study tested if increased intramuscular nitric oxide concentration can improve mitochondrial energy metabolism in Duchenne muscular dystrophy using a novel therapeutic approach through the combination of L-arginine with metformin. Five ambulatory, genetically confirmed Duchenne muscular dystrophy patients aged between 7­10 years were treated with L-arginine (3 x 2.5 g/d) and metformin (2 x 250 mg/d) for 16 weeks. Treatment effects were assessed using mitochondrial protein expression analysis in muscular biopsies, indirect calorimetry, Dual-Energy X-Ray Absorptiometry, quantitative thigh muscle MRI, and clinical scores of muscle performance. There were no serious side effects and no patient dropped out. Muscle biopsy results showed pre-treatment a significantly reduced mitochondrial protein expression and increased oxidative stress in Duchenne muscular dystrophy patients compared to controls. Post-treatment a significant elevation of proteins of the mitochondrial electron transport chain was observed as well as a reduction in oxidative stress. Treatment also decreased resting energy expenditure rates and energy substrate use shifted from carbohydrates to fatty acids. These changes were associated with improved clinical scores. In conclusion pharmacological stimulation of the nitric oxide pathway leads to improved mitochondria function and clinically a slowing of disease progression in Duchenne muscular dystrophy. This study shall lead to further development of this novel therapeutic approach into a real alternative for Duchenne muscular dystrophy patients. TRIAL REGISTRATION: ClinicalTrials.gov NCT02516085.


Asunto(s)
Arginina/uso terapéutico , Metformina/uso terapéutico , Músculo Esquelético/efectos de los fármacos , Distrofia Muscular de Duchenne/tratamiento farmacológico , Arginina/administración & dosificación , Biopsia , Niño , Quimioterapia Combinada , Humanos , Imagen por Resonancia Magnética , Metformina/administración & dosificación , Músculo Esquelético/patología , Músculo Esquelético/fisiopatología , Óxido Nítrico Sintasa de Tipo I/efectos de los fármacos , Proyectos Piloto
6.
Neuromuscul Disord ; 25(9): 679-85, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26096788

RESUMEN

In muscular dystrophies quantitative muscle MRI (qMRI) detects disease progression more sensitively than clinical scores. This prospective one year observational study compared qMRI with clinical scores in Duchenne muscular dystrophy (DMD) to investigate if qMRI can serve as a surrogate outcome measure in clinical trials. In 20 DMD patients the motor function measure (MFM) total and subscores (D1-D3) were done for physical examination, and the fat fraction (MFF) of thigh muscle qMRI was obtained using the two-point Dixon method. Effect sizes (ES) were calculated for all measures. Sample size estimation (SS) was done modelling assumed treatment effects. Ambulant patients <7 years at inclusion improved in the MFM total and D1 score (ES 1.1 and 1.0). Ambulant patients >7 years (highest ES in the MFM D1 subscore (1.2)), and non-ambulant patients (highest ES in the total MFM score (0.7)) worsened. In comparison the ES of QMRI was much larger, e.g. SS estimations for qMRI data were up to 17 fold smaller compared to the MFM total score and up to 7 fold to the D1 subscore, respectively. QMRI shows pathophysiological changes in DMD and might serve as a surrogate outcome measure in clinical trials.


Asunto(s)
Progresión de la Enfermedad , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/patología , Distrofia Muscular de Duchenne/patología , Adolescente , Niño , Preescolar , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos
7.
Muscle Nerve ; 51(6): 918-21, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25736228

RESUMEN

INTRODUCTION: Quantitative MRI techniques detect disease progression in myopathies more sensitively than muscle function measures or conventional MRI. To date, only conventional MRI data using visual rating scales are available for measurement of disease progression in Becker muscular dystrophy (BMD). METHODS: In 3 patients with BMD (mean age 36.8 years), the mean fat fraction (MFF) of the thigh muscles was assessed by MRI at baseline and at 1-year follow-up using a 2-point Dixon approach (2PD). The motor function measurement scale (MFM) was used for clinical assessment. RESULTS: The mean MFF of all muscles at baseline was 61.6% (SD 7.6). It increased by 3.7% to 65.3% (SD 4.7) at follow-up. The severity of muscle involvement varied between various muscle groups. CONCLUSIONS: As in other myopathies, 2PD can quantify fatty muscle degeneration in BMD and can detect disease progression in a small sample size and at relatively short imaging intervals.


Asunto(s)
Músculo Esquelético/patología , Distrofia Muscular de Duchenne/patología , Adulto , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Persona de Mediana Edad , Índice de Severidad de la Enfermedad
8.
J Neuroimaging ; 25(6): 1007-14, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25702714

RESUMEN

BACKGROUND AND PURPOSE: This study assesses whether magnetization transfer (MT) imaging provides additive information to conventional MRI in brain tumors. METHODS: MT data of 26 patients with neoplastic and metastatic brain tumors were analyzed at 1.5 T. For the 3 largest tumor groups investigated in this study--glioblastoma multiforme (GBM), meningiomas, and metastases-statistical comparisons were performed. Analyzed MT parameters included the magnetization transfer ratio (MTR) and 4 quantitative MT parameters (qMT): Relaxation times (T1, T2), exchange rate (kf), and macromolecular content (F). Total imaging time of high-resolution whole brain MTR and qMT imaging with balanced steady-state free precession required 9 minutes. Five ROIs were chosen: Contrast-enhancing (T1W-CE), noncontrast-enhancing (T1W-non-CE), proximal hyperintensity (T2W-pSI), distal hyperintensity (T2W-dSI), and a reference (ref). RESULTS: Pathologies showed significant (P < .05) MT changes (MTR and qMT) compared to the reference. The T1W-CE, T1W-non-CE, and T2W-pSI ROIs of GBMs, meningiomas, and metastases showed significant differences in MTR and qMT estimates. Similar MTR with significant different qMT values were observed in several ROIs among different lesions. MT maps (MTR and qMT) indicated changes in tissue appearing unaffected on MRI in most glial tumors. CONCLUSIONS: MTR and qMT imaging enables a better differentiation between brain tumors and provides additive information to MRI.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Glioblastoma/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Meningioma/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Encéfalo/patología , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/secundario , Femenino , Glioblastoma/patología , Glioblastoma/secundario , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Meningioma/patología , Meningioma/secundario , Persona de Mediana Edad
9.
J Neurol ; 260(4): 969-74, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23138982

RESUMEN

The purpose of this ethics approved trial was to correlate quantitative MRI with functional abilities in both ambulant and non-ambulant Duchenne muscular dystrophy (DMD). Twenty patients with genetically confirmed DMD were recruited. Physical assessment was performed using the motor function measurement (MFM) scale. Axial 3T MRI scans of the thighs were acquired using T1-weighted in- and opposed-phase images (TR = 20 ms, TE1 = 2.45 ms, TE2 = 3.68 ms, flip angle = 15°) to calculate the relative fat fraction according to the two-point Dixon method in the knee extensors, flexors, and adductor muscles. The average MFM was 65.3 % and correlated negatively to age (r (2) = 0.60). Overall mean fat fraction correlated positively to age (r (2) = 0.51-0.64). An average of 5 % increase in mean fat fraction per year was calculated. Mean fat fraction of the quadriceps showed a high negative correlation (r (2) = 0.93) to the D1 (standing position and transfers) component of the MFM. A cutoff for mean fat fraction of 50 % predicted loss of ambulation with a sensitivity of 100 % and a specificity of 91 %. Therefore, quantitative muscle MRI seems to be a promising endpoint for short clinical trials evaluating the effect of newer treatments on the time of loss of ambulation in DMD.


Asunto(s)
Trastornos Neurológicos de la Marcha/etiología , Distrofia Muscular de Duchenne/complicaciones , Distrofia Muscular de Duchenne/patología , Caminata/fisiología , Adolescente , Niño , Preescolar , Evaluación de la Discapacidad , Femenino , Lateralidad Funcional , Humanos , Imagen por Resonancia Magnética , Masculino , Músculo Esquelético/patología , Adulto Joven
10.
Neuromuscul Disord ; 22 Suppl 2: S107-10, 2012 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-22980761

RESUMEN

We examined the influence of a single exercise session on quantitative muscle fat fraction MRI measurements. Ten healthy volunteers were scanned on a 3T body scanner before and after a session of bilateral squats until muscular fatigue. Axial in- and opposed phase images were acquired at a fixed distance from the knee joint and fat fractions were calculated using a 2-point Dixon technique as well as muscle cross sectional area at the same position. After the squat session, calculated fat fraction in the quadriceps bilaterally appeared to be significantly decreased, while all but one non-exercised muscles showed no change. In conclusion exercise might modify the measured apparent fat fraction. Trials using quantitative MRI should consider the timing of scanning sessions and physical examinations to avoid bias caused by the influence of exercise on measurements.


Asunto(s)
Ejercicio Físico , Grasas , Imagen por Resonancia Magnética , Músculo Esquelético/anatomía & histología , Adulto , Femenino , Humanos , Imagenología Tridimensional , Masculino , Adulto Joven
11.
J Neurol ; 259(8): 1648-54, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22297459

RESUMEN

Oculopharyngeal muscular dystrophy (OPMD) is a rare autosomal dominant muscular dystrophy with late onset and slow progression. The aim of this study was to compare different methods of quantitative MRI in the follow-up of OPMD to semiquantitative evaluation of MRI images and to functional parameters. We examined 8 patients with genetically confirmed OPMD and 5 healthy volunteers twice at an interval of 13 months. Motor function measurements (MFM) were assessed. Imaging at 1.5 T (Siemens Magnetom Avanto) comprised two axial slice groups at the largest diameter of thigh and calf and included T1w TSE, 2-point Dixon for muscular fat fraction (MFF) and a multi-contrast TSE sequence to calculate quantitative T2 values. T1 images were analyzed using Fischer's semiquantitative 5-point (0­4) scale. MFM and visual scores showed no significant difference over the study period. Overall T2 values increased in patients over the study period from 49.4 to 51.6 ms, MFF increased from 19.2 to 20.7%. Neither T2 values nor MFF increased in controls. Changes in T2 correlated with the time interval between examinations (r 2 = 0.42). In this small pilot trial, it was shown that quantitative muscle MRI can detect subclinical changes in patients with OPMD. Quantitative MRI might, therefore, be a useful tool for monitoring disease progression in future therapeutic trials.


Asunto(s)
Imagen de Difusión Tensora/métodos , Progresión de la Enfermedad , Distrofia Muscular Oculofaríngea/diagnóstico , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Distrofia Muscular Oculofaríngea/patología , Proyectos Piloto , Adulto Joven
12.
J Neurol ; 258(7): 1333-40, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21340522

RESUMEN

Oculopharyngeal muscular dystrophy (OPMD) is a progressive skeletal muscle dystrophy characterized by ptosis, dysphagia, and upper and lower extremity weakness. We examined eight genetically confirmed OPMD patients to detect a MRI pattern and correlate muscle involvement, with validated clinical evaluation methods. Physical assessment was performed using the Motor Function Measurement (MFM) scale. We imaged the lower extremities on a 1.5 T scanner. Fatty replacement was graded on a 4-point visual scale. We found prominent affection of the adductor and hamstring muscles in the thigh, and soleus and gastrocnemius muscles in the lower leg. The MFM assessment showed relative mild clinical impairment, mostly affecting standing and transfers, while distal motor capacity was hardly affected. We observed a high (negative) correlation between the validated clinical scores and our visual imaging scores suggesting that quantitative and more objective muscle MRI might serve as outcome measure for clinical trials in muscular dystrophies.


Asunto(s)
Debilidad Muscular/etiología , Músculo Esquelético/patología , Distrofia Muscular Oculofaríngea/complicaciones , Distrofia Muscular Oculofaríngea/patología , Adulto , Anciano , Evaluación de la Discapacidad , Femenino , Humanos , Modelos Lineales , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Distrofia Muscular Oculofaríngea/genética , Proteínas de Unión a Poli(A)/genética , Índice de Severidad de la Enfermedad
13.
Magn Reson Med ; 65(1): 195-201, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20981754

RESUMEN

Signal from balanced steady-state free precession is affected by magnetization transfer. To investigate the possible effects on derived T(2) values using variable nutation steady-state free precession, magnetization transfer-effects were modulated by varying the radiofrequency pulse duration only or in combination with variable pulse repetition time. Simulations reveal a clear magnetization transfer dependency of T(2) when decreasing radiofrequency pulse duration, reaching maximal deviation of 34.6% underestimation with rectangular pulses of 300 µs duration. The observed T(2) deviation evaluated in the frontal white matter and caudate nucleus shows a larger underestimation than expected by numerical simulations. However, this observed difference between simulation and measurement is also observed in an aqueous probe and can therefore not be attributed to magnetization transfer: it is an unexpected sensitivity of derived T(2) to radiofrequency pulse modulation. As expected, the limit of sufficiently long radiofrequency pulse duration to suppress magnetization transfer-related signal modulations allows for proper T(2) estimation with variable nutation steady-state free precession.


Asunto(s)
Algoritmos , Artefactos , Encéfalo/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
J Magn Reson Imaging ; 33(1): 203-10, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21182140

RESUMEN

PURPOSE: To analyze and compare three quantitative MRI methods to determine the degree of muscle involvement in oculopharyngeal muscular dystrophy (OPMD). MATERIALS AND METHODS: Muscle fat content (MFC) was determined based on water-fat quantification using a 2-point Dixon (2PD) method and on a histogram analysis of the free induction decay (FID) signal of a gradient-spoiled steady-state free precession (SSFP) sequence. In addition, transverse relaxation times (T2) of muscle tissue were calculated using a monoexponential decay model. RESULTS: We observed an increased mean MFC in OPMD patients as compared to healthy controls with the adductor magnus and soleus muscles being the most involved muscles in the thigh and calf, respectively. Furthermore, strong correlations (0.78 < R² < 0.94) between different quantitative MR methods were observed. Fewer outliers, however, were obtained by the 2PD method and T2 measurements, suggesting these methods being superior to the SSFP-FID method. CONCLUSION: Quantitative MR techniques, such as fast multiecho Dixon methods and T2 imaging, can reliably differentiate between healthy and dystrophic muscles in OPMD, even if muscles are only marginally affected. Quantitative methods thus represent a promising tool that may be able to monitor more objectively the individual disease progression and treatment response in future clinical trials in muscular dystrophies.


Asunto(s)
Tejido Adiposo/patología , Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/patología , Distrofia Muscular Oculofaríngea/patología , Adulto , Anciano , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
Neuroradiology ; 53(3): 159-67, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20480154

RESUMEN

INTRODUCTION: Magnetization transfer (MT) is sensitive to the macromolecular environment of water protons and thereby provides information not obtainable from conventional magnetic resonance imaging (MRI). Compared to standard methods, MT-sensitized balanced steady-state free precession (bSSFP) offers high-resolution images with significantly reduced acquisition times. In this study, high-resolution magnetization transfer ratio (MTR) images from normal appearing brain structures were acquired with bSSFP. METHODS: Twelve subjects were studied on a 1.5 T scanner. MTR values were calculated from MT images acquired in 3D with 1.3 mm isotropic resolution. The complete MT data set was acquired within less than 3.5 min. Forty-one brain structures of the white matter (WM) and gray matter (GM) were identified for each subject. RESULTS: MTR values were higher for WM than GM. In general, MTR values of the WM and GM structures were in good accordance with the literature. However, MTR values showed more homogenous values within WM and GM structures than previous studies. CONCLUSIONS: MT-sensitized bSSFP provides isotropic high-resolution MTR images and hereby allows assessment of reliable MTR data in also very small brain structures in clinically feasible acquisition times and is thus a promising sequence for being widely used in the clinical routine. The present normative data can serve as a reference for the future characterization of brain pathologies.


Asunto(s)
Algoritmos , Encéfalo/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
16.
Magn Reson Med ; 64(1): 149-56, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20572130

RESUMEN

The previously reported concept for quantitative magnetization transfer (MT) imaging using balanced steady-state free precession (SSFP) is applied to nonbalanced SSFP sequences. This offers the possibility to derive quantitative MT parameters of targets with high-susceptibility variations such as the musculoskeletal system, where balanced SSFP suffers from off-resonance-related signal loss. In the first part of this work, an extended SSFP free induction decay (SSFP-FID) signal equation is derived based on a binary spin-bath model. Based on this new description, quantitative MT parameters such as the fractional pool size, magnetization exchange rate, and relaxation times can be assessed. In the second part of this work, MT model parameters are derived from an ex vivo muscle sample, in vivo human femoral muscle, and in vivo human patellar cartilage. Motion sensitivity issues are discussed and results from two-pool SSFP-FID are compared to results from two-pool balanced SSFP and common quantitative MT models. In summary, this work demonstrates that SSFP-FID allows for quantitative MT imaging of targets with high-susceptibility variations within short acquisition times.


Asunto(s)
Algoritmos , Imagen por Resonancia Magnética/métodos , Modelos Biológicos , Cartílago/diagnóstico por imagen , Humanos , Músculo Esquelético/diagnóstico por imagen , Radiografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA