Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
2.
Radiology ; 302(1): 164-174, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34698569

RESUMEN

Background Diagnostic reference levels (DRLs) and achievable doses (ADs) were developed for the 10 most commonly performed pediatric CT examinations in the United States using the American College of Radiology Dose Index Registry. Purpose To develop robust, current, national DRLs and ADs for the 10 most commonly performed pediatric CT examinations as a function of patient age and size. Materials and Methods Data on 10 pediatric (ie, patients aged 18 years and younger) CT examinations performed between 2016 and 2020 at 1625 facilities were analyzed. For head and neck examinations, dose indexes were analyzed based on patient age; for body examinations, dose indexes were analyzed for patient age and effective diameter. Data from 1 543 535 examinations provided medians for AD and 75th percentiles for DRLs for volume CT dose index (CTDIvol), dose-length product (DLP), and size-specific dose estimate (SSDE). Results Of all facilities analyzed, 66% of the facilities (1068 of 1625) were community hospitals, 16% (264 of 1625) were freestanding centers, 9.5% (154 of 1625) were academic facilities, and 3.5% (57 of 1625) were dedicated children's hospitals. Fifty-two percent of the patients (798 577 of 1 543 535) were boys, and 48% (744 958 of 1 543 535) were girls. The median age of patients was 14 years (boys, 13 years; girls, 15 years). The head was the most frequent anatomy examined with CT (876 655 of 1 543 535 examinations [57%]). For head without contrast material CT examinations, the age-based CTDIvol AD ranged from 19 to 46 mGy, and DRL ranged from 23 to 55 mGy, with both AD and DRL increasing with age. For body examinations, DRLs and ADs for size-based CTDIvol, SSDE, and DLP increased consistently with the patient's effective diameter. Conclusion Diagnostic reference levels and achievable doses as a function of patient age and effective diameter were developed for the 10 most commonly performed CT pediatric examinations using American College of Radiology Dose Index Registry data. These benchmarks can guide CT facilities in adjusting pediatric CT protocols and resultant doses for their patients. © RSNA, 2021 An earlier incorrect version appeared online. This article was corrected on October 29, 2021.


Asunto(s)
Niveles de Referencia para Diagnóstico , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Adolescente , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Guías de Práctica Clínica como Asunto , Sistema de Registros , Estados Unidos
4.
Radiology ; 300(3): 518-528, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34156300

RESUMEN

Background Factors affecting radiologists' performance in screening mammography interpretation remain poorly understood. Purpose To identify radiologists characteristics that affect screening mammography interpretation performance. Materials and Methods This retrospective study included 1223 radiologists in the National Mammography Database (NMD) from 2008 to 2019 who could be linked to Centers for Medicare & Medicaid Services (CMS) datasets. NMD screening performance metrics were extracted. Acceptable ranges were defined as follows: recall rate (RR) between 5% and 12%; cancer detection rate (CDR) of at least 2.5 per 1000 screening examinations; positive predictive value of recall (PPV1) between 3% and 8%; positive predictive value of biopsies recommended (PPV2) between 20% and 40%; positive predictive value of biopsies performed (PPV3) between the 25th and 75th percentile of study sample; invasive CDR of at least the 25th percentile of the study sample; and percentage of ductal carcinoma in situ (DCIS) of at least the 25th percentile of the study sample. Radiologist characteristics extracted from CMS datasets included demographics, subspecialization, and clinical practice patterns. Multivariable stepwise logistic regression models were performed to identify characteristics independently associated with acceptable performance for the seven metrics. The most influential characteristics were defined as those independently associated with the majority of the metrics (at least four). Results Relative to radiologists practicing in the Northeast, those in the Midwest were more likely to achieve acceptable RR, PPV1, PPV2, and CDR (odds ratio [OR], 1.4-2.5); those practicing in the West were more likely to achieve acceptable RR, PPV2, and PPV3 (OR, 1.7-2.1) but less likely to achieve acceptable invasive CDR (OR, 0.6). Relative to general radiologists, breast imagers were more likely to achieve acceptable PPV1, invasive CDR, percentage DCIS, and CDR (OR, 1.4-4.4). Those performing diagnostic mammography were more likely to achieve acceptable PPV1, PPV2, PPV3, invasive CDR, and CDR (OR, 1.9-2.9). Those performing breast US were less likely to achieve acceptable PPV1, PPV2, percentage DCIS, and CDR (OR, 0.5-0.7). Conclusion The geographic location of the radiology practice, subspecialization in breast imaging, and performance of diagnostic mammography are associated with better screening mammography performance; performance of breast US is associated with lower performance. ©RSNA, 2021 Online supplemental material is available for this article.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Competencia Clínica , Mamografía , Tamizaje Masivo , Radiólogos/normas , Bases de Datos Factuales , Detección Precoz del Cáncer , Femenino , Humanos , Ubicación de la Práctica Profesional , Especialización , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...