Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Crit Care Med ; 48(11): 1604-1611, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32804785

RESUMEN

OBJECTIVES: To determine whether a modifiable risk factor, endotracheal tube size, is associated with the diagnosis of postextubation aspiration in survivors of acute respiratory failure. DESIGN: Prospective cohort study. SETTING: ICUs at four academic tertiary care medical centers. PATIENTS: Two hundred ten patients who were at least 18 years old, admitted to an ICU, and mechanically ventilated with an endotracheal tube for longer than 48 hours were enrolled. INTERVENTIONS: Within 72 hours of extubation, all patients received a flexible endoscopic evaluation of swallowing examination that entailed administration of ice, thin liquid, thick liquid, puree, and cracker boluses. Patient demographics, treatment variables, and hospital outcomes were abstracted from the patient's medical records. Endotracheal tube size was independently selected by the patient's treating physicians. MEASUREMENTS AND MAIN RESULTS: For each flexible endoscopic evaluation of swallowing examination, laryngeal pathology was evaluated, and for each bolus, a Penetration Aspiration Scale score was assigned. Aspiration (Penetration Aspiration Scale score ≥ 6) was further categorized into nonsilent aspiration (Penetration Aspiration Scale score = 6 or 7) and silent aspiration (Penetration Aspiration Scale score = 8). One third of patients (n = 68) aspirated (Penetration Aspiration Scale score ≥ 6) on at least one bolus, 13.6% (n = 29) exhibited silent aspiration, and 23.8% (n = 50) exhibited nonsilent aspiration. In a multivariable analysis, endotracheal tube size (≤ 7.5 vs ≥ 8.0) was significantly associated with patients exhibiting any aspiration (Penetration Aspiration Scale score ≥ 6) (p = 0.016; odds ratio = 2.17; 95% CI 1.14-4.13) and with risk of developing laryngeal granulation tissue (p = 0.02). CONCLUSIONS: Larger endotracheal tube size was associated with increased risk of aspiration and laryngeal granulation tissue. Using smaller endotracheal tubes may reduce the risk of postextubation aspiration.


Asunto(s)
Deglución , Intubación Intratraqueal/instrumentación , Aspiración Respiratoria/etiología , Insuficiencia Respiratoria/terapia , Anciano , Deglución/fisiología , Femenino , Humanos , Unidades de Cuidados Intensivos , Intubación Intratraqueal/efectos adversos , Intubación Intratraqueal/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Respiración Artificial/efectos adversos , Respiración Artificial/instrumentación , Respiración Artificial/métodos , Factores de Riesgo , Sobrevivientes/estadística & datos numéricos
2.
Chest ; 158(5): 1923-1933, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32721404

RESUMEN

BACKGROUND: The bedside swallowing evaluation (BSE) is an assessment of swallowing function and airway safety during swallowing. After extubation, the BSE often is used to identify the risk of aspiration in acute respiratory failure (ARF) survivors. RESEARCH QUESTION: We conducted a multicenter prospective study of ARF survivors to determine the accuracy of the BSE and to develop a decision tree algorithm to identify aspiration risk. STUDY DESIGN AND METHODS: Patients extubated after ≥ 48 hours of mechanical ventilation were eligible. Study procedures included the BSE followed by a gold standard evaluation, the flexible endoscopic evaluation of swallowing (FEES). RESULTS: Overall, 213 patients were included in the final analysis. Median time from extubation to BSE was 25 hours (interquartile range, 21-45 hours). The FEES was completed 1 hour after the BSE (interquartile range, 0.5-2 hours). A total of 33% (70/213; 95% CI, 26.6%-39.2%) of patients aspirated on at least one FEES bolus consistency test. Thin liquids were the most commonly aspirated consistency: 27% (54/197; 95% CI, 21%-34%). The BSE detected any aspiration with an accuracy of 52% (95% CI, 45%-58%), a sensitivity of 83% (95% CI, 74%-92%), and negative predictive value (NPV) of 81% (95% CI, 72%-91%). Using recursive partitioning analyses, a five-variable BSE-based decision tree algorithm was developed that improved the detection of aspiration with an accuracy of 81% (95% CI, 75%-87%), sensitivity of 95% (95% CI, 90%-98%), and NPV of 97% (95% CI, 95%-99%). INTERPRETATION: The BSE demonstrates variable accuracy to identify patients at high risk for aspiration. Our decision tree algorithm may enhance the BSE and may be used to identify patients at high risk for aspiration, yet requires further validation. TRIAL REGISTRY: ClinicalTrials.gov; No.: NCT02363686; URL: www.clinicaltrials.gov.


Asunto(s)
Extubación Traqueal , Deglución , Pruebas en el Punto de Atención , Aspiración Respiratoria/diagnóstico , Insuficiencia Respiratoria , Evaluación de Síntomas/métodos , Extubación Traqueal/efectos adversos , Extubación Traqueal/métodos , Algoritmos , Árboles de Decisión , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Respiración Artificial/métodos , Aspiración Respiratoria/etiología , Aspiración Respiratoria/fisiopatología , Aspiración Respiratoria/prevención & control , Insuficiencia Respiratoria/diagnóstico , Insuficiencia Respiratoria/fisiopatología , Insuficiencia Respiratoria/terapia , Medición de Riesgo , Sobrevivientes/estadística & datos numéricos , Estados Unidos/epidemiología