Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Vet Sci ; 9: 1027878, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36524223

RESUMEN

Alternatives to carbon dioxide (CO2) stunning for the commercial slaughter of pigs are urgently needed because there is robust evidence that exposing pigs to hypercapnic environments is associated with pain, fear, and distress. Hypobaric hypoxia (via gradual decompression, also known as Low Atmospheric Pressure Stunning or LAPS) has been validated in poultry as a humane option, but its potential to improve the welfare of pigs at slaughter is unknown. We investigated the potential of hypobaric hypoxia to reliably elicit a non-recovery state in anesthetized weaner-grower pigs within a commercially viable timeframe. We determined the effect of candidate decompression rates (40, 60, 80, 100 ms-1, at two cycle durations 480 s and 720 s) on a range of physiological and reflexive behavioral indicators of hypoxia and death. We found that the decompression rates tested caused a 100% death rate. As expected, the decompression rate had overarching effects on behavioral and physiological markers of hypoxia and death, with faster decompression rates resulting in shorter latencies to cardiac arrest and cessation of breathing. We observed a higher proportion of pigs displaying repeated and prolonged whole-body movements (likely indicative of convulsive activity) at higher frequencies when we applied the slowest decompression rate (40 ms-1) compared to all other rates. Since these responses may impact the carcass and meat quality, the slower rate of decompression (40 ms-1) should be excluded as a candidate decompression rate. Furthermore, given the marginal effects of decompression rate on physiological indicators of death and reflexive behavioral parameters, we also recommend that the fastest rate tested (100 ms-1) is excluded in further study on conscious pigs (to prevent conscious animals from being exposed to unnecessary faster decompression rates which may compromise animal welfare). This work represents a necessary proof of principle step and confirms the potential of gradual decompression for stunning purposes in pigs. Importantly, however, the data presented provide no information on the welfare outcomes associated with decompression in conscious pigs. Subsequent work should focus on the comprehensive welfare assessment of intermediate decompression rates to determine the potential of hypobaric hypoxia to provide a humane stunning method for pigs.

2.
Front Vet Sci ; 9: 1027883, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36439339

RESUMEN

Pigs are commonly stunned pre-slaughter by exposure to carbon dioxide (CO2), but this approach is associated with significant welfare concerns. Hypobaric hypoxia, achieved with gradual decompression (also known as Low Atmospheric Pressure Stunning or LAPS) may be an alternative, allowing the retention of welfare friendly handling approaches and group stunning. Although validated in poultry, the feasibility and welfare consequences of gradual decompression for pigs are unknown. Here, we characterize pathological changes in 60 pigs resulting from exposure to a range of candidate decompression curves (ranging from 40 to 100 ms-1 ascent equivalent, with two cycle durations 480 and 720 s). To protect welfare, we worked on unconscious, terminally anesthetized pigs which were subject to detailed post-mortem examinations by a specialized porcine veterinary pathologist. All pigs were killed as a result of exposure to decompression, irrespective of cycle rate or length. Pigs showed no external injuries during ante-mortem inspections. Exposing pigs to decompression and the unavoidable subsequent recompression resulted in generalized congestion of the carcass, organs and body cavities including the ears, oral cavity, conjunctivae and sclera, mucosa of other external orifices (anus and vulva), nasal planum, nasal cavities including nasal conchae, frontal sinuses, cranium, meninges, brain, larynx, trachea, lungs, heart, parietal pleura of the thoracic cavity, peritoneum of the abdominal cavity, stomach, small intestine, caecum, colon, liver, spleen and kidneys and representative joint cavities in the limbs (stifles and elbows). Various severities of hemorrhage were observed in the conjunctivae and sclera, mucosa of other external orifices (anus and vulva), nasal cavities including nasal conchae, frontal sinuses, cranium, meninges, brain, larynx, tracheal lumen, lungs, parietal pleura of the thoracic cavity, liver, spleen and kidneys and representative joint cavities in the limbs (stifles and elbows). In general, faster decompression rates produced higher scores, but in the conjunctivae, sclera and kidneys, faster decompression rates were associated with marginally lower congestion scores. There was considerable individual variation in pathological scores across all body regions. The congestion and hemorrhage observed could translate into welfare harms in conscious pigs undergoing this type of stunning, depending when in the cycle the damage is occurring, but no welfare related conclusions can be drawn from the responses of unconscious pigs. Since recompression is always required, its effects cannot be separated from decompression, however cessation of cardiac activity several minutes before recompression should have eliminated any haemodynamic effects relating to cardiac function and blood pressure. This study represents the first systematic attempt to identify candidate rate profiles to underpin future explorations of decompression as a stunning method for pigs. These pathological findings also inform discussions about the likely carcass quality implications of this novel stunning method.

3.
J Clin Invest ; 132(20)2022 10 17.
Artículo en Inglés | MEDLINE | ID: mdl-36040802

RESUMEN

CLN1 disease, also called infantile neuronal ceroid lipofuscinosis (NCL) or infantile Batten disease, is a fatal neurodegenerative lysosomal storage disorder resulting from mutations in the CLN1 gene encoding the soluble lysosomal enzyme palmitoyl-protein thioesterase 1 (PPT1). Therapies for CLN1 disease have proven challenging because of the aggressive disease course and the need to treat widespread areas of the brain and spinal cord. Indeed, gene therapy has proven less effective for CLN1 disease than for other similar lysosomal enzyme deficiencies. We therefore tested the efficacy of enzyme replacement therapy (ERT) by administering monthly infusions of recombinant human PPT1 (rhPPT1) to PPT1-deficient mice (Cln1-/-) and CLN1R151X sheep to assess how to potentially scale up for translation. In Cln1-/- mice, intracerebrovascular (i.c.v.) rhPPT1 delivery was the most effective route of administration, resulting in therapeutically relevant CNS levels of PPT1 activity. rhPPT1-treated mice had improved motor function, reduced disease-associated pathology, and diminished neuronal loss. In CLN1R151X sheep, i.c.v. infusions resulted in widespread rhPPT1 distribution and positive treatment effects measured by quantitative structural MRI and neuropathology. This study demonstrates the feasibility and therapeutic efficacy of i.c.v. rhPPT1 ERT. These findings represent a key step toward clinical testing of ERT in children with CLN1 disease and highlight the importance of a cross-species approach to developing a successful treatment strategy.


Asunto(s)
Lipofuscinosis Ceroideas Neuronales , Animales , Niño , Modelos Animales de Enfermedad , Terapia de Reemplazo Enzimático , Humanos , Ratones , Mutación , Lipofuscinosis Ceroideas Neuronales/tratamiento farmacológico , Lipofuscinosis Ceroideas Neuronales/genética , Ovinos
4.
Biosens Bioelectron ; 197: 113728, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-34763151

RESUMEN

The development of robust implantable sensors is important in the successful advancement of personalised medicine as they have the potential to provide in situ real-time data regarding the status of health and disease and the effectiveness of treatment. Tissue pH is a key physiological parameter and herein, we report the design, fabrication, functionalisation, encapsulation and protection of a miniaturised, self-contained, electrochemical pH sensor system and characterisation of sensor performance. Notably for the first time in this environment the pH sensor was based on a methylene blue redox reporter which showed remarkable robustness, accuracy and sensitivity. This was achieved by encapsulation of a self-assembled monolayer containing methylene blue entrapped within a Nafion layer. Another powerful feature was the incorporation, within the same implanted device, of a fabricated on-chip Ag/AgCl reference electrode - vital in any electrochemical sensor, but often ignored. When utilised in vivo, the sensor allowed accurate tracking of externally induced pH changes within a naturally occurring ovine lung cancer model, and correlated well with single point laboratory measurements made on extracted arterial blood, whilst enabling in vivo time-dependent measurements. The sensors functioned robustly whilst implanted, and maintained in vitro function once extracted and together, these results demonstrate proof-of-concept of the ability to sense real-time intratumoral tissue pH changes in vivo.


Asunto(s)
Técnicas Biosensibles , Azul de Metileno , Animales , Técnicas Electroquímicas , Concentración de Iones de Hidrógeno , Oxidación-Reducción , Ovinos
5.
Hepatology ; 74(1): 428-443, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33420756

RESUMEN

BACKGROUND AND AIMS: Liver graft quality is evaluated by visual inspection prior to transplantation, a process highly dependent on the surgeon's experience. We present an objective, noninvasive, quantitative way of assessing liver quality in real time using Raman spectroscopy, a laser-based tool for analyzing biomolecular composition. APPROACH AND RESULTS: A porcine model of donation after circulatory death (DCD) with normothermic regional perfusion (NRP) allowed assessment of liver quality premortem, during warm ischemia (WI) and post-NRP. Ten percent of circulating blood volume was removed in half of experiments to simulate blood recovery for DCD heart removal. Left median lobe biopsies were obtained before circulatory arrest, after 45 minutes of WI, and after 2 hours of NRP and analyzed using spontaneous Raman spectroscopy, stimulated Raman spectroscopy (SRS), and staining. Measurements were also taken in situ from the porcine liver using a handheld Raman spectrometer at these time points from left median and right lateral lobes. Raman microspectroscopy detected congestion during WI by measurement of the intrinsic Raman signal of hemoglobin in red blood cells (RBCs), eliminating the need for exogenous labels. Critically, this microvascular damage was not observed during WI when 10% of circulating blood was removed before cardiac arrest. Two hours of NRP effectively cleared RBCs from congested livers. Intact RBCs were visualized rapidly at high resolution using SRS. Optical properties of ischemic livers were significantly different from preischemic and post-NRP livers as measured using a handheld Raman spectrometer. CONCLUSIONS: Raman spectroscopy is an effective tool for detecting microvascular damage which could assist the decision to use marginal livers for transplantation. Reducing the volume of circulating blood before circulatory arrest in DCD may help reduce microvascular damage.


Asunto(s)
Selección de Donante/métodos , Paro Cardíaco/fisiopatología , Isquemia/diagnóstico , Hígado/irrigación sanguínea , Espectrometría Raman , Animales , Modelos Animales de Enfermedad , Estudios de Factibilidad , Humanos , Isquemia/fisiopatología , Trasplante de Hígado , Preservación de Órganos , Perfusión , Porcinos , Isquemia Tibia
6.
Lab Anim ; 55(2): 177-180, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33045909

RESUMEN

Pigs are used to model humans in gastrointestinal (GI) studies because of their comparable size, physiology and behaviour: both are monogastric omnivores. A porcine surgical model for testing novel, tethered ultrasound capsule endoscopes (USCE) requires a clean, motile small intestine. Recommendations for human GI tract preparation before the mechanically similar process of video capsule endoscopy describe using oral purgatives, while high-carbohydrate drinks are recommended before colorectal surgery. Reports of the GI preparation of pigs exist but lack technical details, that is, administration, efficacy and side effects. This report details feeding a high-energy liquid diet to 11 female pigs undergoing surgery and USCE which was readily accepted and easily administered, and which produced a clean, motile small intestine and caused no detectable physiological/behavioural abnormalities.


Asunto(s)
Crianza de Animales Domésticos/métodos , Endoscopios en Cápsulas/estadística & datos numéricos , Endoscopía Capsular/estadística & datos numéricos , Dieta , Sus scrofa/fisiología , Animales , Femenino , Intestino Delgado/fisiología , Modelos Animales , Sus scrofa/cirugía
7.
Clin Toxicol (Phila) ; 58(3): 190-200, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31389254

RESUMEN

Background: Dicobalt edetate and hydroxocobalamin are widely used to treat hydrogen cyanide poisoning. However, comparative and quantitative efficacy data are lacking. Although post-exposure treatment is typical, it may be possible to administer these antidotes before exposure to first attenders entering a known site of cyanide release, as supplementary protection to their personal protective equipment.Methods: We established an anaesthetised Gottingen minipig model of lethal bolus potassium cyanide (KCN) injection to simulate high dose hydrogen cyanide inhalation. Doses were similar to human lethal doses of KCN. Dicobalt edetate and hydroxocobalamin were administered shortly before KCN and their effect on metabolic and cardiovascular variables and survival time were measured.Results: Increases in arterial lactate were similar after 0.08 and 0.12 mmol/kg KCN. KCN 0.08 mmol/kg was survived by 4/4 animals with moderate cardiovascular effects, while the 0.12 mmol/kg dose was lethal in 4/4 animals, with a mean time to euthanasia of 28.3 (SEM: 13.9) min. Administration of dicobalt edetate (0.021 mmol/kg, 8.6 mg/kg) or hydroxocobalamin (0.054 mmol/kg, 75 mg/kg) at clinically licenced doses had modest effect on lactate concentrations but increased survival after administration of KCN 0.12 mmol/kg (survival: dicobalt edetate 4/4, hydroxocobalamin 2/4) but not 0.15 mmol/kg (0/4 and 0/4, respectively). In a subsequent larger study, doubling the dose of hydroxocobalamin (0.108 mmol/kg, 150 mg/kg) was associated with a modest but inconsistent increased survival after 0.15 mmol/kg KCN (survival: control 0/8, 75 mg/kg 1/10, 150 mg/kg 3/10) likely due to variable pharmacokinetics.Conclusions: In this porcine study of cyanide exposure, with pre-exposure antidote administration, licenced doses of dicobalt edetate and hydroxocobalamin were effective at just lethal doses but ineffective at less than twice the estimated LD50. The efficacy of a rapidly-administered double-dose of hydroxocobalamin was limited by variable pharmacokinetics. In clinical poisoning scenarios, with delayed administration, the antidotes are likely to be even less effective. New antidotes are required for treatment of cyanide exposures appreciably above the minimum lethal dose.


Asunto(s)
Antídotos/uso terapéutico , Quelantes/uso terapéutico , Cianuros/envenenamiento , Ácido Edético/uso terapéutico , Hidroxocobalamina/uso terapéutico , Animales , Cianuros/antagonistas & inhibidores , Modelos Animales de Enfermedad , Relación Dosis-Respuesta a Droga , Ácido Edético/administración & dosificación , Hidroxocobalamina/administración & dosificación , Masculino , Profilaxis Pre-Exposición/métodos , Porcinos , Porcinos Enanos
8.
Front Oncol ; 9: 534, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31316911

RESUMEN

In vitro cell line and in vivo murine models have historically dominated pre-clinical cancer research. These models can be expensive and time consuming and lead to only a small percentage of anti-cancer drugs gaining a license for human use. Large animal models that reflect human disease have high translational value; these can be used to overcome current pre-clinical research limitations through the integration of drug development techniques with surgical procedures and anesthetic protocols, along with emerging fields such as implantable medical devices. Ovine pulmonary adenocarcinoma (OPA) is a naturally-occurring lung cancer that is caused by the jaagsiekte sheep retrovirus. The disease has similar histological classification and oncogenic pathway activation to that of human lung adenocarcinomas making it a valuable model for studying human lung cancer. Developing OPA models to include techniques used in the treatment of human lung cancer would enhance its translational potential, making it an excellent research tool in assessing cancer therapeutics. In this study we developed a novel OPA model to validate the ability of miniaturized implantable O2 and pH sensors to monitor the tumor microenvironment. Naturally-occurring pre-clinical OPA cases were obtained through an on-farm ultrasound screening programme. Sensors were implanted into OPA tumors of anesthetized sheep using a CT-guided trans-thoracic percutaneous implantation procedure. This study reports the findings from 9 sheep that received sensor implantations. Time taken from initial CT scans to the placement of a single sensor into an OPA tumor was 45 ± 5 min, with all implantations resulting in the successful delivery of sensors into tumors. Immediate post-implantation mild pneumothoraces occurred in 4 sheep, which was successfully managed in all cases. This is, to the best of our knowledge, the first description of the use of naturally-occurring OPA cases as a pre-clinical surgical model. Through the integration of techniques used in the treatment of human lung cancer patients, including ultrasound, general anesthesia, CT and surgery into the OPA model, we have demonstrated its translational potential. Although our research was tailored specifically for the implantation of sensors into lung tumors, we believe the model could also be developed for other pre-clinical applications.

9.
Vet Anaesth Analg ; 46(5): 620-626, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31296379

RESUMEN

OBJECTIVE: This pilot study aimed to evaluate the feasibility of transcranial bioimpedance (TCBI) measurement and variability of TCBI values in healthy conscious horses and to study effects of body position and time on TCBI in anaesthetized horses. STUDY DESIGN: Prospective, observational study. ANIMALS: A total of four research horses and 16 client-owned horses presented for surgery. METHODS: After establishing optimal electrode position using computed tomography scans of cadaver heads, TCBI [described using impedance at zero frequency, R0, (Ω)] was measured in four conscious, resting horses to investigate the feasibility and changes in TCBI over time (80 minutes). Data were compared using a paired t test. TCBI was then measured throughout anaesthesia (duration 92 ± 28 minutes) in 16 horses in dorsal and lateral recumbency. Data were analysed using a general linear model; gamma regression was chosen as a model of characteristic impedance [Zc; (Ω)] against time. Data are presented as mean ± standard deviation. RESULTS: No change in R0 was seen in conscious horses (age = 15.3 ± 7.3 years, body mass = 512 ± 38 kg) over 80 minutes. The technique was well tolerated and caused no apparent adverse effects. In 16 horses (age = 7.4 ± 4.7 years; body mass = 479 ± 134 kg) anaesthetized for 92 ± 28 minutes, Zc fell during anaesthesia, decreasing more in horses in lateral recumbency than in horses in dorsal recumbency (p = 0.008). There was no relationship between Zc and body mass or age. CONCLUSIONS AND CLINICAL RELEVANCE: TCBI is readily measured in horses. TCBI did not change with time in conscious horses, but decreased with time in anaesthetized horses; this change was greater in horses in lateral recumbency, indicating that TCBI changes in anaesthetized horses may be related to the effects of recumbency, general anaesthesia, surgery or a combination of these factors.


Asunto(s)
Anestesia General/veterinaria , Encéfalo/fisiología , Impedancia Eléctrica , Caballos/fisiología , Animales , Femenino , Caballos/cirugía , Periodo Intraoperatorio , Masculino , Proyectos Piloto , Estudios Prospectivos
10.
Front Oncol ; 9: 335, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31106157

RESUMEN

Lung cancer represents a major worldwide health concern; although advances in patient management have improved outcomes for some patients, overall 5-year survival rates are only around 15%. In vitro studies and mouse models are commonly used to study lung cancer and their use has increased the molecular understanding of the disease. Unfortunately, mouse models are poor predictors of clinical outcome and seldom mimic advanced stages of the human disease. Animal models that more accurately reflect human disease are required for progress to be made in improving treatment outcomes and prognosis. Similarities in pulmonary anatomy and physiology potentially make sheep better models for studying human lung function and disease. Ovine pulmonary adenocarcinoma (OPA) is a naturally occurring lung cancer that is caused by the jaagsiekte sheep retrovirus. The disease is endemic in many countries throughout the world and has several features in common with human lung adenocarcinomas, including histological classification and activation of common cellular signaling pathways. Here we discuss the in vivo and in vitro OPA models that are currently available and describe the advantages of using pre-clinical naturally occurring OPA cases as a translational animal model for human lung adenocarcinoma. The challenges and options for obtaining these OPA cases for research purposes, along with their use in developing novel techniques for the evaluation of chemotherapeutic agents or for monitoring the tumor microenvironment in response to treatment, are also discussed.

12.
IEEE Trans Biomed Eng ; 66(3): 632-639, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-29993482

RESUMEN

Clinical endoscopy and colonoscopy are commonly used to investigate and diagnose disorders in the upper gastrointestinal tract and colon, respectively. However, examination of the anatomically remote small bowel with conventional endoscopy is challenging. This and advances in miniaturization led to the development of video capsule endoscopy (VCE) to allow small bowel examination in a noninvasive manner. Available since 2001, current capsule endoscopes are limited to viewing the mucosal surface only due to their reliance on optical imaging. To overcome this limitation with submucosal imaging, work is under way to implement microultrasound (µUS) imaging in the same form as VCE devices. This paper describes two prototype capsules, termed Sonocap and Thermocap, which were developed respectively to assess the quality of µUS imaging and the maximum power consumption that can be tolerated for such a system. The capsules were tested in vivo in the oesophagus and small bowel of porcine models. Results are presented in the form of µUS B-scans as well as safe temperature readings observed up to 100 mW in both biological regions. These results demonstrate that acoustic coupling and µUS imaging can be achieved in vivo in the lumen of the bowel and the maximum power consumption that is possible for miniature µUS systems.


Asunto(s)
Endoscopios en Cápsulas , Endoscopía Capsular/instrumentación , Termometría/instrumentación , Ultrasonografía/instrumentación , Animales , Endoscopía Capsular/métodos , Colon/diagnóstico por imagen , Colon/fisiología , Diseño de Equipo , Femenino , Humanos , Miniaturización/instrumentación , Seguridad del Paciente , Porcinos , Termometría/métodos , Ultrasonografía/métodos
13.
Clin Toxicol (Phila) ; 56(8): 773-781, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29334816

RESUMEN

BACKGROUND: Colchicine poisoning is commonly lethal. Colchicine-specific Fab fragments increase rat urinary colchicine clearance and have been associated with a good outcome in one patient. We aimed to develop a porcine model of colchicine toxicity to study the pharmacokinetics and efficacy of ovine Fab. METHODS: A Göttingen minipig critical care model was established and serial blood samples taken for colchicine and Fab pharmacokinetics, clinical chemistry, and haematology. Animals were euthanised when the mean arterial pressure fell below 45 mmHg without response to vasopressor, or at study completion. RESULTS: Initial studies indicated that oral dosing produced variable pharmacokinetics and time-to-euthanasia. By contrast, intravenous infusion of 0.25 mg/kg colchicine over 1 h produced reproducible pharmacokinetics (AUC0-20 343 [SD = 21] µg/L/h), acute multi-organ injury, and cardiotoxicity requiring euthanasia a mean of 22.5 (SD = 3.2) h after dosing. A full-neutralising equimolar Fab dose given 6 h after the infusion (50% first hour, 50% next 6 h [to reduce renal-loss of unbound Fab]) produced a 7.35-fold increase in plasma colchicine (AUC0-20 2,522 [SD = 14] µg/L/h), and removed all free plasma colchicine, but did not prevent toxicity (euthanasia at 29.1 [SD = 3.4] h). Earlier administration over 1 h of the full-neutralising dose, 1 or 3 h after the colchicine, produced a 12.9-fold (AUC0-20 4,433 [SD = 607] µg/L/h) and 6.0-fold (AUC0-20 2,047 [SD = 51] µg/L/h) increase in plasma colchicine, respectively, absence of free plasma colchicine until 20 h, and survival to study end without marked cardiotoxicity. CONCLUSIONS: Colchicine-specific Fab given early, in equimolar dose, bound colchicine, eliciting its movement into the blood, and preventing severe toxicity. Clinical studies are now needed to determine how soon this antidote must be given to work in human poisoning.


Asunto(s)
Antídotos/farmacología , Antídotos/uso terapéutico , Colchicina/sangre , Colchicina/envenenamiento , Fragmentos Fab de Inmunoglobulinas/farmacología , Fragmentos Fab de Inmunoglobulinas/uso terapéutico , Administración Intravenosa , Administración Oral , Animales , Fragmentos Fab de Inmunoglobulinas/sangre , Modelos Animales , Porcinos , Porcinos Enanos
14.
IEEE Trans Biomed Circuits Syst ; 12(1): 95-105, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29377799

RESUMEN

This paper describes the design, fabrication, packaging, and performance characterization of a conformal helix antenna created on the outside of a capsule endoscope designed to operate at a carrier frequency of 433 MHz within human tissue. Wireless data transfer was established between the integrated capsule system and an external receiver. The telemetry system was tested within a tissue phantom and in vivo porcine models. Two different types of transmission modes were tested. The first mode, replicating normal operating conditions, used data packets at a steady power level of 0 dBm, while the capsule was being withdrawn at a steady rate from the small intestine. The second mode, replicating the worst-case clinical scenario of capsule retention within the small bowel, sent data with stepwise increasing power levels of -10, 0, 6, and 10 dBm, with the capsule fixed in position. The temperature of the tissue surrounding the external antenna was monitored at all times using thermistors embedded within the capsule shell to observe potential safety issues. The recorded data showed, for both modes of operation, a low error transmission of 10-3 packet error rate and 10-5 bit error rate and no temperature increase of the tissue according to IEEE standards.


Asunto(s)
Endoscopía Capsular/instrumentación , Tecnología de Sensores Remotos , Tecnología Inalámbrica/instrumentación , Animales , Endoscopía Capsular/métodos , Tecnología de Sensores Remotos/instrumentación , Tecnología de Sensores Remotos/métodos , Porcinos
16.
Arch Dis Child ; 102(5): 403-409, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27831907

RESUMEN

OBJECTIVE: To determine the effect of visual feedback on rate of chest compressions, secondarily relating the forces used. DESIGN: Randomised crossover trial. SETTING: Tertiary teaching hospital. SUBJECTS: Fifty trained hospital staff. INTERVENTIONS: A thin sensor-mat placed over the manikin's chest measured rate and force. Rescuers applied compressions to the same paediatric manikin for two sessions. During one session they received visual feedback comparing their real-time rate with published guidelines. OUTCOME MEASURES: Primary: compression rate. Secondary: compression and residual forces. RESULTS: Rate of chest compressions (compressions per minute (compressions per minute; cpm)) varied widely (mean (SD) 111 (13), range 89-168), with a fourfold difference in variation during session 1 between those receiving and not receiving feedback (108 (5) vs 120 (20)). The interaction of session by feedback order was highly significant, indicating that this difference in mean rate between sessions was 14 cpm less (95% CI -22 to -5, p=0.002) in those given feedback first compared with those given it second. Compression force (N) varied widely (mean (SD) 306 (94); range 142-769). Those receiving feedback second (as opposed to first) used significantly lower force (adjusted mean difference -80 (95% CI -128 to -32), p=0.002). Mean residual force (18 N, SD 12, range 0-49) was unaffected by the intervention. CONCLUSIONS: While visual feedback restricted excessive compression rates to within the prescribed range, applied force remained widely variable. The forces required may differ with growth, but such variation treating one manikin is alarming. Feedback technologies additionally measuring force (effort) could help to standardise and define effective treatments throughout childhood.


Asunto(s)
Reanimación Cardiopulmonar/educación , Educación Continua/métodos , Retroalimentación , Adulto , Reanimación Cardiopulmonar/métodos , Reanimación Cardiopulmonar/normas , Niño , Competencia Clínica , Estudios Cruzados , Evaluación Educacional/métodos , Femenino , Humanos , Conocimiento Psicológico de los Resultados , Masculino , Maniquíes , Esfuerzo Físico , Presión
17.
Physiotherapy ; 101(4): 357-63, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25749494

RESUMEN

OBJECTIVES: To investigate differences, if any, in the delivery of respiratory treatments to mechanically ventilated children between non-respiratory on-call physiotherapists and specialist respiratory physiotherapists. SETTING: Paediatric, tertiary care hospital in the United Kingdom. PARTICIPANTS: 93 children (aged between 3 days and 16 years), and 22 physiotherapists (10 specialist respiratory physiotherapists) were recruited to the study. INTERVENTIONS: Recruited children received two physiotherapy treatments during a single day, one delivered by a non-respiratory physiotherapist, the other by a specialist respiratory physiotherapist in a randomised order. Selection, delivery and effects of techniques were recorded for each treatment. OUTCOME MEASURES: Primary outcomes were selection and application of treatment components. Secondary outcomes included respiratory effects (in terms of changes in flow, volume and pressure) of selected treatment components. RESULTS: Both non-respiratory on-call physiotherapists and specialist respiratory physiotherapists used combinations of saline instillation, manual lung inflations, chest wall vibrations and endotracheal suction during treatments. However specialist respiratory physiotherapists used combinations of chest wall vibrations with suction, and recruitment manoeuvres, significantly more frequently than non-respiratory on-call physiotherapists (92% vs 52%, and 87% vs 46% of treatments respectively, P<0.001). Chest wall vibrations delivered by non-respiratory on-call physiotherapists were 15% less effective at increasing peak expiratory flow. CONCLUSION: Clinically important differences between non-respiratory and specialist respiratory physiotherapists' treatment outcomes may be related to differences in the selection and application of techniques. This suggests an important training need for non-respiratory on-call physiotherapists, particularly in the effective delivery of physiotherapy techniques. TRIAL REGISTRATION: Clinicaltrials.gov NCT01999426.


Asunto(s)
Fisioterapeutas , Respiración Artificial/métodos , Respiración Artificial/normas , Adolescente , Niño , Preescolar , Estudios Cruzados , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Reino Unido
18.
Physiotherapy ; 101(4): 349-56, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25749495

RESUMEN

OBJECTIVES: The study investigated treatment outcomes when respiratory physiotherapy was delivered by non-respiratory on-call physiotherapists, compared with specialist respiratory physiotherapists. DESIGN: Prospective, randomised crossover trial. SETTING: Paediatric, tertiary care hospital in the United Kingdom. PARTICIPANTS: Mechanically ventilated children requiring two physiotherapy interventions during a single day were eligible. Twenty two physiotherapists (10 non-respiratory) and 93 patients were recruited. INTERVENTIONS: Patients received one treatment from a non-respiratory physiotherapist and another from a respiratory physiotherapist, in a randomised order. Treatments were individualised to the patients' needs, often including re-positioning followed by manual lung inflations, chest wall vibrations and endotracheal suction. MAIN OUTCOME MEASURES: The primary outcome was respiratory compliance. Secondary outcomes included adverse physiological events and clinically important respiratory changes (according to an a priori definition). RESULTS: Treatments delivered to 63 patients were analysed. There were significant improvements to respiratory compliance (mean increase [95% confidence intervals], 0.07 and 0.08ml·cmH2O(-1)·kg(-1) [0.01 to 0.14 and 0.04 to 0.13], p<0.01, for on-call and respiratory physiotherapists' treatments respectively). Case-by-case, there were fewer clinically important improvements following non-respiratory physiotherapists' treatments compared with the respiratory physiotherapists' (n=27 [43%] versus n=40 [63%], p=0.03). Eleven adverse events occurred, eight following non-respiratory physiotherapists' treatments. CONCLUSIONS: Significant disparities exist in treatment outcomes when patients are treated by non-respiratory on-call physiotherapists, compared with specialist respiratory physiotherapists. There is an urgent need for targeted training strategies, or alternative service delivery models, to be explored. This should aim to address the quality of respiratory physiotherapy services, both during and outside of normal working hours. CLINICAL TRIAL REGISTRATION NUMBER: Clinicaltrials.gov, NCT01999426.


Asunto(s)
Hospitales Pediátricos , Fisioterapeutas , Terapia Respiratoria/métodos , Terapia Respiratoria/normas , Adolescente , Niño , Preescolar , Estudios Cruzados , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Estudios Prospectivos , Respiración Artificial , Método Simple Ciego , Reino Unido
20.
Can Vet J ; 53(9): 978-82, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23450862

RESUMEN

A 7-year-old gelded Irish sports horse weighing 650 kg was anesthetized on 2 consecutive days for lavage of a septic right radio-carpal joint. On both occasions the endotracheal tube connector, which had been bound in medical tape to produce an airtight seal, functioned as a unidirectional valve during mechanical ventilation, retarding expiration, imposing positive end expiratory pressure (PEEP), and probably continuous positive airway pressure (CPAP). The equipment dysfunction was not identified on either occasion despite close inspection prompted by progressive increases in airway pressure and thoracic distension. Whilst the PEEP and CPAP exerted unexpectedly modest cardiovascular effects and the horse recovered uneventfully on both occasions, the improvisation may have proven fatal in a higher-risk subject.A 7-year-old gelded Irish sports horse weighing 650 kg was anesthetized on 2 consecutive days for lavage of a septic right radio-carpal joint. On both occasions the endotracheal tube connector, which had been bound in medical tape to produce an airtight seal, functioned as a unidirectional valve during mechanical ventilation, retarding expiration, imposing positive end expiratory pressure (PEEP), and probably continuous positive airway pressure (CPAP). The equipment dysfunction was not identified on either occasion despite close inspection prompted by progressive increases in airway pressure and thoracic distension. Whilst the PEEP and CPAP exerted unexpectedly modest cardiovascular effects and the horse recovered uneventfully on both occasions, the improvisation may have proven fatal in a higher-risk subject.


RésuméMauvais usage quasi-mortel de ruban adhésif médical autour d'un raccord de tube endotrachéal durant l'anesthésie par inhalation chez un cheval. Un hongre de sport Irlandais âgé de 7 ans pesant 650 kg a été anesthésié deux journées consécutives pour le lavage d'une articulation radio-carpienne droite septique. Lors des deux instances, le raccord du tube endotrachéal, qui avait été attaché à l'aide de ruban adhésif médical pour produire une fermeture hermétique, a servi de valve unidirectionnelle durant la ventilation mécanique, retardant l'expiration, imposant une pression positive en fin d'expiration et probablement une ventilation spontanée en pression positive continue. La défaillance de l'équipement n'a pas été identifiée dans l'une ou l'autre de ces instances, malgré une inspection minutieuse suscitée par des hausses progressives de la pression des voies aériennes et un gonflement thoracique. Même si la pression positive en fin d'expiration et la ventilation spontanée en pression positive continue ont eu des effets cardiovasculaires modestes inattendus et que le cheval s'est rétabli sans incident lors des deux instances, l'improvisation aurait pu s'avérée mortelle chez un sujet présentant des risques plus élevés.(Traduit par Isabelle Vallières).


Asunto(s)
Anestesia por Inhalación/veterinaria , Presión de las Vías Aéreas Positiva Contínua/veterinaria , Respiración Artificial/veterinaria , Anestesia por Inhalación/efectos adversos , Anestesia por Inhalación/instrumentación , Anestesia por Inhalación/métodos , Animales , Presión de las Vías Aéreas Positiva Contínua/instrumentación , Presión de las Vías Aéreas Positiva Contínua/métodos , Enfermedades de los Caballos/cirugía , Caballos , Masculino , Respiración con Presión Positiva , Respiración Artificial/instrumentación , Respiración Artificial/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...