Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Am J Nephrol ; 54(7-8): 281-290, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37356428

RESUMEN

INTRODUCTION: Novel urinary biomarkers, including tissue inhibitor metalloprotease-2 and insulin-like growth factor binding protein 7 ([TIMP-2]*[IGFBP7]), have been developed to identify patients at risk for acute kidney injury (AKI). We investigated the "real-world" clinical utility of [TIMP-2]*[IGFBP7] in preventing AKI. METHODS: We performed a before and after single-center quality improvement study of intensive care unit (ICU) patients at risk for severe (KDIGO stage 2 or 3) AKI. In the prospective cohort, ICU providers were allowed to order [TIMP-2]*[IGFBP7] for patients at their discretion, then offered AKI practice recommendations based on the results. Outcomes were compared to a historical cohort in which biomarker values were not reported to clinical teams. RESULTS: There was no difference in 7-day progression to severe AKI between the prospective (n = 116) and historical cohorts (n = 63) when [TIMP-2]*[IGFBP7] ≥0.3 (24 [28%] versus 8 [21%], p = 0.38) despite more stage 1 AKI at time of biomarker measurement in the prospective cohort (58 [67%] versus 9 [23%], p < 0.001). In the prospective cohort, patients with higher [TIMP-2]*[IGFBP7] values were more likely to receive a nephrology consult. Early consultation (within 24 h of biomarker measurement, n = 20) had a nonsignificant trend toward net negative volume balance (-1,787 mL [6,716 mL] versus + 4,974 mL [15,540 mL]) and more diuretic use (19 [95%] versus 8 [80%]) and was associated with less severe AKI (9 [45%] versus 10 [100%], p = 0.004) and inpatient dialysis (2 [10%] versus 7 [70%], p = 0.002) compared to delayed consultation (n = 10). CONCLUSIONS: Despite the prospective cohort having more preexisting stage 1 AKI, there were equal rates of progression to severe AKI in the prospective and historical cohorts. In the setting of [TIMP-2]*[IGFBP7] reporting, there were more nephrology consults in response to elevated biomarker levels. Early nephrology consultation resulted in improved volume balance and favorable outcomes compared to delayed consultation.


Asunto(s)
Lesión Renal Aguda , Inhibidor Tisular de Metaloproteinasa-2 , Humanos , Estudios Prospectivos , Mejoramiento de la Calidad , Biomarcadores , Lesión Renal Aguda/diagnóstico , Proteínas de Unión a Factor de Crecimiento Similar a la Insulina
2.
J Appl Lab Med ; 8(2): 285-295, 2023 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-36592084

RESUMEN

BACKGROUND: Using middleware solutions, it is possible to implement concentration-dependent analyte-specific hemolysis rejection limits. This makes day-to-day reporting of clinical specimens more efficient and potentially lowers sample rejection rates compared to a "one-size-fits-all" approach (i.e., solely based on a single cutoff provided in the package insert). METHODS: Hemolysis interference studies were performed at multiple analyte concentrations for three frequently ordered tests. For each assay, concentration-dependent hemolysis rejection limits were designed based on the total allowable error (TAE) for the analyte as well as the clinical significance of such incurred inaccuracy at the respective concentrations. In general, the following rationale was used: if the interference exceeds 10% (or package insert cutoffs), a comment is placed on the result. If the interference exceeds the TAE, the result will not be reported. Reduction in specimen rejection rates were estimated by comparing the incurred specimen rejection rates when package inserts' vs concentration-dependent hemolysis interference limits were applied to a data set in our institute during a three-month period. RESULTS: Concentration-dependent analyte-specific hemolysis rejection thresholds were designed for three commonly ordered assays that are especially susceptible to hemolysis interference. It is estimated that these novel thresholds for aspartate aminotransferase (AST), lactate dehydrogenase (LDH), and direct bilirubin (DBIL) reduced specimen rejection rates from 9.3% to 1.3%, 31.4% to 4.8%, and 19.9% to 7.1%, respectively. CONCLUSIONS: Concentration-dependent analyte-specific hemolysis rejection thresholds for three commonly ordered assays can reduce rejection rates without significantly compromising the quality of test results.


Asunto(s)
Hemólisis , L-Lactato Deshidrogenasa , Humanos , Aspartato Aminotransferasas , Bilirrubina
4.
J Appl Lab Med ; 4(2): 247-253, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31639671

RESUMEN

BACKGROUND: The interest for vitamin D has exponentially increased testing demand for 25-hydroxy vitamin D [25(OH)D]. Consequently, many laboratories are switching from LC-MS/MS methods to automated, high-throughput immunoassays. One of the major potential issues with these assays has been the lack of cross-reactivity with 25(OH)D2. METHODS: We have evaluated the Roche Elecsys vitamin D total II assay for accuracy by comparing 79 patient samples with LC-MS/MS. The cross-reactivity for 25(OH)D2 was evaluated by analyzing samples with high 25(OH)D2 separately and estimating 25(OH)D2 recovery, as well as by spiking of 25(OH)D2. The assay was further evaluated for precision, linearity, sample type, and common interferences. RESULTS: There was mostly good agreement between the Elecsys and LC-MS/MS assays (Deming regression: y = 0.95x + 0.70), with an overall bias of 2.3% (-0.84 ng/mL). However, there were 6 out of 79 (7.6%) discordant samples. The Deming regression for samples with high 25(OH)D2 compared to LC-MS/MS showed similar slope and intercept (y = 0.97x - 1.1). The average recovery of 25(OH)D2 for these samples was 90%. The initial precision studies were in general agreement with the package insert, but long-term clinical use showed higher-than-claimed imprecision (11.7%-14.4% at 12 ng/mL and 6.9%-7.6% at 27 ng/mL; claimed: 7.2% and 5.0%, respectively). We observed 1 falsely high result in plasma, an issue previously addressed by Roche in a medical device correction. CONCLUSIONS: The analytical performance of the Roche Vitamin D assay was acceptable, and the assay had a good cross-reactivity for 25(OH)D2.


Asunto(s)
Ensayos Analíticos de Alto Rendimiento/instrumentación , Inmunoensayo/instrumentación , Juego de Reactivos para Diagnóstico , Vitamina D/análogos & derivados , Unión Competitiva , Cromatografía Líquida de Alta Presión/métodos , Reacciones Falso Positivas , Ensayos Analíticos de Alto Rendimiento/métodos , Humanos , Inmunoensayo/métodos , Unión Proteica , Espectrometría de Masas en Tándem/métodos , Vitamina D/sangre , Vitamina D/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA