1.
Lab Chip ; 15(9): 2090-101, 2015 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-25815443

RESUMEN

A new generation of the Ephesia cell capture technology optimized for CTC capture and genetic analysis is presented, characterized in depth and compared with the CellSearch system as a reference. This technology uses magnetic particles bearing tumour-cell specific EpCAM antibodies, self-assembled in a regular array in a microfluidic flow cell. 48,000 high aspect-ratio columns are generated using a magnetic field in a high throughput (>3 ml h(-1)) device and act as sieves to specifically capture the cells of interest through antibody-antigen interactions. Using this device optimized for CTC capture and analysis, we demonstrated the capture of epithelial cells with capture efficiency above 90% for concentrations as low as a few cells per ml. We showed the high specificity of capture with only 0.26% of non-epithelial cells captured for concentrations above 10 million cells per ml. We investigated the capture behavior of cells in the device, and correlated the cell attachment rate with the EpCAM expression on the cell membranes for six different cell lines. We developed and characterized a two-step blood processing method to allow for rapid processing of 10 ml blood tubes in less than 4 hours, and showed a capture rate of 70% for as low as 25 cells spiked in 10 ml blood tubes, with less than 100 contaminating hematopoietic cells. Using this device and procedure, we validated our system on patient samples using an automated cell immunostaining procedure and a semi-automated cell counting method. Our device captured CTCs in 75% of metastatic prostate cancer patients and 80% of metastatic breast cancer patients, and showed similar or better results than the CellSearch device in 10 out of 13 samples. Finally, we demonstrated the possibility of detecting cancer-related PIK3CA gene mutation in 20 cells captured in the chip with a good correlation between the cell count and the quantitation value Cq of the post-capture qPCR.


Asunto(s)
Análisis Mutacional de ADN/métodos , Separación Inmunomagnética/métodos , Técnicas Analíticas Microfluídicas/métodos , Mutación , Células Neoplásicas Circulantes/metabolismo , Células Neoplásicas Circulantes/patología , Antígenos de Neoplasias/metabolismo , Línea Celular Tumoral , Humanos , Separación Inmunomagnética/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Células Neoplásicas Circulantes/inmunología , Reproducibilidad de los Resultados
2.
Lab Chip ; 15(3): 811-22, 2015 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-25474258

RESUMEN

Microfluidic systems bear promise to provide new powerful tools for the molecular characterization of cancer cells, in particular for the routine detection of multiple cancer biomarkers using a minute amount of the sample. However, taking miniaturized cell-based assays into the clinics requires the implementation and validation of complex biological protocols on chip, as well as the development of disposable microdevices produced at a low cost. Based on a recently developed microfluidic chip made of Cyclic Olefin Copolymer for cell immobilization with minimal dead volume and controlled shear stress, we developed a protocol performed entirely in the liquid phase, allowing the immobilization and fixation of cells and their quantitative characterization by fluorescence in situ hybridization. We demonstrated first in cell lines and then in two clinical case studies the potential of this method to perform quantitative copy number measurement and clinical scoring of the amplification of the ERBB2 gene, a decisive biomarker for the prescription of HER2+ related targeted therapies. This validation was performed in a blind protocol in two clinical case studies, in reference to the gold standard and clinically used method based on glass slides. We obtained a comparable reproducibility and a minor difference in apparent amplification, which can be corrected by internal calibration. The method thus reaches the standard of robustness needed for clinical use. The protocol can be fully automated, and its consumption of samples and DNA probes is reduced as compared to glass slide protocols by a factor of at least 10. The total duration of the assay is divided by two.


Asunto(s)
Neoplasias de la Mama/genética , Hibridación Fluorescente in Situ , Técnicas Analíticas Microfluídicas , Diseño de Equipo , Femenino , Humanos , Hibridación Fluorescente in Situ/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Receptor ErbB-2/genética , Células Tumorales Cultivadas