Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
BMC Health Serv Res ; 24(1): 401, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38553724

RESUMEN

BACKGROUND: Point-of-care testing (POCT) devices are diagnostic tools that can provide quick and accurate results within minutes, making them suitable for diagnosing non-communicable diseases (NCDs). However, these devices are not widely implemented in healthcare systems and for this reason is relevant to understand the implementation process. AIM: To describe the process and define a strategy to implement a multiparameter POCT device for diagnosing and managing NCDs in one region of Peru. METHODS: A descriptive and non-experimental study, using the participatory methodologies of co-creation process. It was conducted in one region of Peru (Tumbes) to design an intervention for implementing a multiparameter POCT device. Two co-creation sessions were conducted involving five groups: community members, primary healthcare workers, these groups in both rural and urban settings, and regional decision-makers. These sessions included activities to understand patient journeys in receiving care for NCDs, identify facilitators and barriers to POCT devices usage, and define an implementation strategy for POCT devices in both rural and urban settings of Tumbes. The research team analysed the data and summarized key topics for discussion after each session. RESULTS: A total of 78 participants were enrolled across the five groups. Among community members: 22.2% had only diabetes, 24.1% had only hypertension, and 18.5% had both diagnoses. In the patient journey, community members mentioned that it took at least three days to receive a diagnosis and treatment for an NCD. Most of the participants agreed that the POCT devices would be beneficial for their communities, but they also identified some concerns. The strategy for POCT devices implementation included healthcare workers training, POCT devices must be placed in the laboratory area and must be able to perform tests for glucose, glycated haemoglobin, cholesterol, and creatinine. Advertising about POCT devices should be displayed at the healthcare centres and the municipality using billboards and flyers. CONCLUSIONS: The co-creation process was useful to develop strategies for the implementation of multiparameter POCT devices for NCDs, involving the participation of different groups of stakeholders guided by moderators in both, rural and urban, settings in Peru.


Asunto(s)
Diabetes Mellitus , Enfermedades no Transmisibles , Humanos , Enfermedades no Transmisibles/epidemiología , Enfermedades no Transmisibles/terapia , Perú , Pruebas en el Punto de Atención , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/terapia , Atención Primaria de Salud , Sistemas de Atención de Punto
2.
BMC Health Serv Res ; 23(1): 412, 2023 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-37118750

RESUMEN

BACKGROUND: Point-of-care testing (POCT) devices may facilitate the delivery of rapid and timely results, providing a clinically important advantage in patient management. The challenges and constraints in the implementation process, considering different levels of actors have not been much explored. This scoping review aimed to assess literature pertaining to implementation facilitators and barriers of POCT devices for the diagnosis or monitoring of cardiometabolic diseases. METHODS: A scoping review of the literature was conducted. The inclusion criteria were studies on the inception, planning, or implementation of interventions with POCT devices for the diagnosis or monitoring of cardiometabolic diseases defined as dyslipidemia, cardiovascular diseases, type 2 diabetes, and chronic kidney disease. We searched MEDLINE, Embase, and Global Health databases using the OVID searching engine until May 2022. The Consolidated Framework of Implementation Research (CFIR) was used to classify implementation barriers and facilitators in five constructs. Also, patient, healthcare professional (HCP), and organization level was used. RESULTS: Twenty studies met the eligibility criteria for data extraction. All studies except two were conducted in high-income countries. Some findings are: 1) Intervention: the most widely recognized facilitator was the quick turnaround time with which results are obtained. 2) Outer setting: at the organizational level, the lack of clear regulatory and accreditation mechanisms has hindered the adoption and sustainability of the use of POCT. 3) Inner setting: for HCP, performing POCT during the consultation was both a facilitator and a barrier in terms of time, personnel, and service delivery. 4) Individuals: the implementation of POCT may generate stress and discomfort in some HCP in terms of training and new responsibilities. 5) Process: for patients, it is highly appreciated that obtaining the sample was simple and more comfortable if venipuncture was not used. CONCLUSION: This scoping review has described the facilitators and barriers of implementing a POCT device for cardiometabolic conditions using the CFIR. The information can be used to design better strategies to implement these devices and benefit more populations that have low access to cardiometabolic tests.


Asunto(s)
Diabetes Mellitus Tipo 2 , Sistemas de Atención de Punto , Humanos , Personal de Salud , Pruebas en el Punto de Atención
3.
Curr Med Chem ; 30(33): 3775-3797, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36424777

RESUMEN

BACKGROUND: Although radiotherapy is one of the main cancer treatment modalities, exposing healthy organs/tissues to ionizing radiation during treatment can lead to different adverse effects. In this regard, it has been shown that the use of radioprotective agents may alleviate the ionizing radiation-induced toxicities. OBJECTIVE: The present study aims to review the radioprotective potentials of silymarin/silibinin in the prevention/reduction of ionizing radiation-induced adverse effects on healthy cells/tissues. METHODS: Based on PRISMA guidelines, a comprehensive and systematic search was performed for identifying relevant literature on the "potential protective role of silymarin/silibinin in the treatment of radiotherapy-induced toxicities" in the different electronic databases of Web of Science, PubMed, and Scopus up to April 2022. Four hundred and fifty-five articles were obtained and screened in accordance with the inclusion and exclusion criteria of the current study. Finally, 19 papers were included in this systematic review. RESULTS: The findings revealed that the ionizing radiation-treated groups had reduced survival rates and body weight in comparison with the control groups. It was also found that radiation can induce mild to severe adverse effects on the skin, digestive, hematologic, lymphatic, respiratory, reproductive, and urinary systems. Nevertheless, the administration of silymarin/silibinin could mitigate the ionizing radiation-induced adverse effects in most cases. This herbal agent exerts its radioprotective effects through anti-oxidant, anti-apoptosis, anti-inflammatory activities, and other mechanisms. CONCLUSION: The results of the current systematic review showed that co-treatment of silymarin/silibinin with radiotherapy alleviates the radiotherapy-induced adverse effects in healthy cells/tissues.


Asunto(s)
Protección Radiológica , Silimarina , Humanos , Silimarina/farmacología , Silimarina/uso terapéutico , Silibina , Antioxidantes/farmacología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA