Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Patient Saf Surg ; 18(1): 17, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38778372

RESUMEN

BACKGROUND: Open reduction and plate fixation is a standard procedure for treating traumatic symphyseal disruptions, but has a high incidence of implant failure. Several studies have attempted to identify predictors for implant failure and discussed its impact on functional outcome presenting conflicting results. Therefore, this study aimed to identify predictors of implant failure and to investigate the impact of implant failure on pain and functional outcome. METHODS: In a single-center, retrospective, observational non-controlled cohort study in a level-1 trauma center from January 1, 2006, to December 31, 2017, 42 patients with a plate fixation of a traumatic symphyseal disruption aged ≥ 18 years with a minimum follow-up of 12 months were included. The following parameters were examined in terms of effect on occurrence of implant failure: age, body mass index (BMI), injury severity score (ISS), polytrauma, time to definitive treatment, postoperative weight-bearing, the occurrence of a surgical site infection, fracture severity, type of posterior injury, anterior and posterior fixation. A total of 25/42 patients consented to attend the follow- up examination, where pain was assessed using the Numerical Rating Scale and functional outcome using the Majeed Pelvic Score. RESULTS: Sixteen patients had an anterior implant failure (16/42; 37%). None of the parameters studied were predictive for implant failure. The median follow-up time was six years and 8/25 patients had implant failure. There was no difference in the Numerical Rating Scale, but the work-adjusted Majeed Pelvic Score showed a better outcome for patients with implant failure. CONCLUSION: implant failure after symphyseal disruptions is not predictable, but appears to be clinically irrelevant. Therefore, an additional sacroiliac screw to prevent implant failure should be critically discussed and plate removal should be avoided in asymptomatic patients.

2.
Patient Saf Surg ; 18(1): 15, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38689330

RESUMEN

BACKGROUND: Mortality of patients with a femoral neck fracture is high, especially within the first year after surgery, but also remains elevated thereafter. The aim of this study was to identify factors potentially associated with long-term mortality in patients homogeneously treated with hemiarthroplasty for femoral neck fracture. METHODS: This retrospective cohort study was performed at a single level 1 national trauma center at the university hospital of Leipzig (Saxony, Germany). The study time-window was January 1, 2010 to December 31, 2020. Primary outcome measure was mortality depending on individual patient-related characteristics and perioperative risk factors. Inclusion criteria was a low-energy femoral neck fracture (Garden I-IV) in geriatric patients 60 years of age or older that were primarily treated with bipolar hemiarthroplasty. Date of death or actual residence of patients alive was obtained from the population register of the eastern German state of Saxony, Germany. The outcome was tested using the log-rank test and plotted using Kaplan-Meier curves. Unadjusted and adjusted for other risk factors such as sex and age, hazard ratios were calculated using Cox proportional hazards models and presented with 95% confidence intervals (CI). RESULTS: The 458 included patients had a median age of 83 (IQR 77-89) years, 346 (75%) were female and 113 (25%) male patients. Mortality rates after 30 days, 1, 5 and 10 years were 13%, 25%, 60% and 80%, respectively. Multivariate regression analysis revealed age (HR = 1.1; p < 0.001), male gender (HR = 1.6; p < 0.001), ASA-Score 3-4 vs. 1-2 (HR = 1.3; p < 0.001), dementia (HR = 1.9; p < 0.001) and a history of malignancy (HR = 1.6; p = 0.002) as independent predictors for a higher long-term mortality risk. Perioperative factors such as preoperative waiting time, early surgical complications, or experience of the surgeon were not associated with a higher overall mortality. CONCLUSIONS: In the present study based on data from the population registry from Saxony, Germany the 10-year mortality of older patients above 60 years of age managed with hemiarthroplasty for femoral neck fracture was 80%. Independent risk factors for increased long-term mortality were higher patient age, male gender, severe comorbidity, a history of cancer and in particular dementia. Perioperative factors did not affect long-term mortality.

3.
J Mech Behav Biomed Mater ; 153: 106488, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38437754

RESUMEN

INTRODUCTION: This systematic review aims to identify previously used techniques in biomechanics to assess pelvic instability following pelvic injury, focusing on external fixation constructs. METHODS: A systematic literature search was conducted to include biomechanical studies and to exclude clinical trials. RESULTS: Of an initial 4666 studies found, 38 met the inclusion criteria. 84% of the included studies were retrieved from PubMed, Scopus, and Web of Science. The studies analysed 106 postmortem specimens, 154 synthetic bones, and 103 computational models. Most specimens were male (97% synthetic, 70% postmortem specimens). Both the type of injury and the classification system employed varied across studies. About 82% of the injuries assessed were of type C. Two different fixators were tested for FFPII and type A injury, five for type B injury, and fifteen for type C injury. Large variability was observed for external fixation constructs concerning device type and configuration, pin size, and geometry. Biomechanical studies deployed various methods to assess injury displacement, deformation, stiffness, and motion. Thereby, loading protocols differed and inconsistent definitions of failure were determined. Measurement techniques applied in biomechanical test setups included strain gauges, force transducers, and motion tracking techniques. DISCUSSION AND CONCLUSION: An ideal fixation method should be safe, stable, non-obstructive, and have low complication rates. Although biomechanical testing should ensure that the load applied during testing is representative of a physiological load, a high degree of variability was found in the current literature in both the loading and measurement equipment. The lack of a standardised test design for fixation constructs in pelvic injuries across the studies challenges comparisons between them. When interpreting the results of biomechanical studies, it seems crucial to consider the limitations in cross-study comparability, with implications on their applicability to the clinical setting.


Asunto(s)
Fracturas Óseas , Huesos Pélvicos , Humanos , Fenómenos Biomecánicos , Fijadores Externos , Fijación de Fractura/métodos , Huesos Pélvicos/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA