Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Knee Surg Sports Traumatol Arthrosc ; 31(12): 5453-5462, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37804346

RESUMEN

PURPOSE: This study reports the five-year functional outcomes from a prospective cohort study comparing robotic-arm assisted total knee arthroplasty (RO TKA) versus conventional manual total knee arthroplasty (CO TKA). METHODS: This prospective single-surgeon study included 120 patients with symptomatic end-stage knee arthritis undergoing primary TKA. This included 60 consecutive patients undergoing CO TKA followed by 60 consecutive patients undergoing RO TKA using a semi-automated robotic device. Study patients were reviewed at one, two, and five years after surgery and the following outcomes recorded: The University of California at Los Angeles activity-level (UCLA), Knee Society Score (KSS), Oxford Knee Score (OKS) Forgotten Joint Score (FJS), and any complications. RESULTS: There were no statistical differences between RO TKA and CO TKA in the median UCLA score (p = N.S), median KSS (p = N.S), and median OKS (p = N.S) at five-year follow-up. RO-TKA was associated with statistically significant improvements in the FJS at one (p = 0.001), two (p = 0.003), and five (p = 0.025) years of follow-up compared with CO TKA. There was no statistical difference in the incidence of knee stiffness requiring manipulation under anesthesia between the two treatment groups (p = N.S). CONCLUSION: Patients in both treatment groups had excellent functional outcomes with comparable patient reported outcomes at five-year follow-up. RO TKA was associated with statistically significant improvements in the FJS compared with CO TKA, but these differences did not reach the minimal clinically important difference at any follow-up interval. There was no overall difference in complications between the two treatment groups at five-year follow-up. LEVEL OF EVIDENCE: II (Prospective cohort study).


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Articulación de la Rodilla/cirugía , Estudios Prospectivos , Estudios de Seguimiento , Resultado del Tratamiento
2.
J Bone Joint Surg Am ; 104(21): 1905-1914, 2022 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-36074816

RESUMEN

BACKGROUND: Although the exact etiology of patient dissatisfaction in total knee arthroplasty (TKA) is unclear, the inflammatory response precipitated by surgery may be implicated. Robotic TKA has been shown to result in reduced bone and soft-tissue trauma. The objectives of this study were to compare the inflammatory response in conventional jig-based TKA versus robotic-arm-assisted TKA and to examine the relationship with early functional outcomes. METHODS: This prospective randomized controlled trial included 15 patients with symptomatic knee osteoarthritis undergoing conventional TKA and 15 undergoing robotic-arm-assisted TKA. Blood samples were collected for up to 28 days postoperatively, and predefined markers of systemic inflammation were measured in serum. The local inflammatory response was assessed by analyzing samples from the intra-articular drain fluid at 6 and 24 hours. Relationships with early functional outcomes were evaluated using the Spearman rank correlation coefficient. RESULTS: Patients in the robotic TKA group demonstrated lower levels of interleukin (IL)-6 in the drain fluid at 6 hours (798.54 pg/mL versus 5,699.2 pg/mL, p = 0.026) and 24 hours and IL-8 at 6 hours. Robotic TKA was associated with lower pain scores on postoperative days 1, 2, and 7. Patient-reported outcome measures were comparable between the 2 groups at 2 years. Significant correlations were observed between all serum markers except IL-1b and self-reported pain on postoperative day 7; between drain IL-8 levels and pain on postoperative days 1 (r = 0.458), 2, and 7; and between drain IL-6, IL-8, and tumor necrosis factor-alpha levels at 6 hours and knee flexion or extension. CONCLUSIONS: Robotic-arm-assisted TKA was associated with a reduction in the early postoperative local inflammatory response. We also found a moderate relationship between the inflammatory responses and self-reported pain, knee flexion, and knee extension. Further validation of these findings on a larger scale and using longer-term outcomes will be key to developing the optimal TKA procedure. LEVEL OF EVIDENCE: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Brazo/cirugía , Artroplastia de Reemplazo de Rodilla/métodos , Interleucina-8 , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Dolor , Estudios Prospectivos , Procedimientos Quirúrgicos Robotizados/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA